• Title/Summary/Keyword: micro climate

Search Result 169, Processing Time 0.034 seconds

Study on the Thermal Characteristics of Concrete Using Insulation Performance Improve Material (단열성능향상 재료를 사용한 콘크리트의 열적 특성에 관한 연구)

  • Park, Young-Shin;Kim, Jung-Ho;Kang, Yeun-Woo;Youm, Kwang-Soo;Jeon, Hyun-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.227-228
    • /
    • 2013
  • Recently, it is certain that the increase of heating and cooling energy consumption by radical change in climate condition has caused serious problems related to environmental and energy concerns associated with increase of fossil fuel usage and carbon dioxide production as well as global warming. So, various actions to reduce greenhouse gas exhaustion and energy consumption have been prepared by world developed countries. The energy consumption by buildings approximately reaches 25% of total korea energy consumption. The greatest part in the buildings of the energy consumption is building facade. but a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research structural insulation concrete what improved insulation performance using insulation performance improve material.

  • PDF

A Study on a Regulation Draft of Inspection and Maintenance for Lightning Protection Facilities based on IEC 62305 (국제표준(IEC 62305) 도입에 따른 피뢰시스템 검사 및 유지관리에 대한 연구)

  • Lee, Kang-Hee;Lee, Sang-Hyup;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.838-844
    • /
    • 2015
  • Latest development of ICT makes building, including houses, factories and public facilities, more intelligent and automatized. It follows that a wide variety of electric and ICT installations are adopted along with micro electronic equipments. Corresponding to such changes, the frequency of lightning increases due to the abnormal climate. The major damage by lightning surge is disconnection and malfunction of facilities. It is necessary, therefore, to make a regulation of inspection and maintenance for lightning protection facilities. This paper deals with main issues of a regulation draft of inspection and maintenance for lightning protection facilities based on IEC 62305

Spatial distribution of heterotrophic bacteria and the role of microbial food web in the northern East China Sea in summer (하계 동중국해 북부해역에서 종속영양박테리아의 분포 특성 및 미생물 먹이망의 역할)

  • Bomina Kim;Seok-Hyun Youn
    • Korean Journal of Environmental Biology
    • /
    • v.41 no.1
    • /
    • pp.89-100
    • /
    • 2023
  • We investigated the spatial distribution of heterotrophic bacteria associated with different water masses in the northern East China Sea(ECS) in summer. The surface water masses were divided into the Changjiang Diluted Water (CDW) and high salinity water (HSW). In the CDW region, the concentrations of dissolved inorganic nitrogen (DIN) and chlorophyll-a (Chl-a), and micro Chl-a contribution were high; and bacterial abundance (BA) and ciliate abundance (CA) were also high. In the HSW region with relatively low DIN concentrations, Chl-a concentration and micro Chl-a contribution were low, but pico Chl-a contribution was increased compared to those in the CDW region. BA did not show any significant difference from the CDW region, but CA was decreased. BA showed a positive correlation with Chl-a concentration in the CDW region; however, it did not show a significant correlation with Chl-a concentration in the HSW region. The ratio of bacterial carbon biomass/phytoplankton carbon biomass was exponentially increased with a decrease in the Chl-a concentration. Compared to the past (1990-2000s), the surface phosphate concentrations and the size of dominant phytoplankton have recently decreased in the ECS. Considering this trend of nutrient decrease and miniaturization of the phytoplankton, our results indicate that changes in the strength of the oligotrophic water mass could alter the function of the microbial food web.

Study on the Thermal Characteristics of Concrete Using Micro Form Admixture (마이크로기포제를 사용한 콘크리트의 열적 특성에 관한 연구)

  • Park, Young Shin;Kim, Jung Ho;Jeon, Hyun Kyu;Seo, Chee Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Recently, it is certain that the increase of heating and cooling energy consumption by radical change in climate condition has caused serious problems related to environmental and energy concerns associated with increase of fossil fuel usage and carbon dioxide production as well as global warming. So, various actions to reduce greenhouse gas exhaustion and energy consumption have been prepared by world developed countries. Our government has also been trying to seek energy control methods for houses and buildings by proclaiming political polices on low-carbon green growth and construction and performance standards for environment-friendly housing. The energy consumption by buildings approximately reaches 25% of total korea energy consumption, and the increasing rate of energy consumption by buildings is stiffer than the rate by the other industries. The greatest part in the buildings of the energy consumption is building facade. While lots of research projects for reducing energy consumption of the facade have been conducted, but a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research presents here a study to improve the insulation property of structural concrete formed by micro form admixture (MFA) with experimentally reviewing the physical, mechanical and thermal characteristics of the concrete. As the results of this experiment, in the case of concrete mixed with MFA, slump loss has been improved. As the mixing ratio of MFA increases, the compressive strength is decreased and thermal conductivity is increased. Also it was found that water-cement ratio increases, the compressive strength is decreased and thermal conductivity is increased. but, there was not big influence by the change of fine aggregate ratio.

A Design Process for Reduction of Pressure Drop of Air-cooled Condenser for Waste Heat Recovery System (폐열 회수 시스템용 공랭식 응축기의 압력 손실 저감 설계)

  • Bae, Sukjung;Heo, Hyungseok;Park, Jeongsang;Lee, Hongyeol;Kim, Charnjung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.6
    • /
    • pp.81-91
    • /
    • 2013
  • A novel design process of a parallel multi-flow type air-cooled condenser of a dual-loop waste heat recovery system with Rankine steam cycles for improving the fuel efficiency of gasoline automobiles has been investigated focusing on reduction of the pressure drop inside the micro-tubes. The low temperature condenser plays a role to dissipate heat from the system by condensing the low temperature loop working fluid sufficiently. However, the refrigerant has low evaporation temperature enough to recover the waste from engine coolant of about $100^{\circ}C$ but has small saturation enthalpy so that excessive mass flow rate of the LT working fluid, e.g., over 150 g/s, causes enormously large pressure drop of the working fluid to maintain the heat dissipation performance of more than 20 kW. This paper has dealt with the scheme to design the low temperature condenser that has reduced pressure drop while ensuring the required thermal performance. The number of pass, the arrangement of the tubes of each pass, and the positions of the inlet and outlet ports on the header are most critical parameters affecting the flow uniformity through all the tubes of the condenser. For the purpose of the performance predictions and the parametric study for the LT condenser, we have developed a 1-dimensional user-friendly performance prediction program that calculates feasibly the phase change of the working fluid in the tubes. An example is presented through the proposed design process and compared with an experiment.

Quantitative analysis of the errors associated with orbit uncertainty for FORMOSAT-3

  • Wu Bor-Han;Fu Ching-Lung;Liou Yuei-An;Chen Way-Jin;Pan Hsu-Pin
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.87-90
    • /
    • 2005
  • The FORMOSAT-3/COSMIC mission is a micro satellite mission to deploy a constellation of six micro satellites at low Earth orbits. The final mission orbit is of an altitude of 750-800 lan. It is a collaborative Taiwan-USA science experiment. Each satellite consists of three science payloads in which the GPS occultation experiment (GOX) payload will collect the GPS signals for the studies of meteorology, climate, space weather, and geodesy. The GOX onboard FORMOSAT -3 is designed as a GPS receiver with 4 antennas. The fore and aft limb antennas are installed on the front and back sides, respectively, and as well as the two precise orbit determination (POD) antennas. The precise orbit information is needed for both the occultation inversion and geodetic research. However, the instrument associated errors, such as the antenna phase center offset and even the different cable delay due to the geometric configuration of fore- and aft-positions of the POD antennas produce error on the orbit. Thus, the focus of this study is to investigate the impact of POD antenna parameter on the determination of precise satellite orbit. Furthermore, the effect of the accuracy of the determined satellite orbit on the retrieved atmospheric and ionospheric parameters is also examined. The CHAMP data, the FORMOSAT-3 satellite and orbit parameters, the Bernese 5.0 software, and the occultation data processing system are used in this work. The results show that 8 cm error on the POD antenna phase center can result in ~8 cm bias on the determined orbit and subsequently cause 0.2 K deviation on the retrieved atmospheric temperature at altitudes above 10 lan.

  • PDF

Food-Web Structures in the Lower Trophic Levels of the Korean Seas (East Sea, West Sea, South Sea, and East China Sea) during the Summer Season: Using Carbon and Nitrogen Stable Isotopes (하계 한반도 해역(동해, 서해, 남해 및 동중국해)의 하위영양단계 먹이망 구조 : 탄소 및 질소 안정동위원소 활용)

  • Min, Jun-Oh;Lee, Chang-Hwa;Youn, Seok-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.493-505
    • /
    • 2020
  • Food web structures in the lower trophic levels of the seas around the Korean peninsula were investigated in August 2019 using stable isotopes. There were variable ratios of the carbon (-26.18 ~ -20.61 ‰) and nitrogen stable (5.36 ~ 15.20 ‰) isotopes in the particulate organic matter (POM). Most of the organisms ingested micro-POM as a major food source, but this varied spatially. The chaetognaths (3.40 ± 0.61) occupied the highest trophic level. The isotope mixing model showed that the proportions (13 ~ 51 %) of some organisms (i.e., copepods and euphausiids) reflected the relative contributions as major food sources for chaetognaths at each site.

A Study on the Economic Benefit of Urban Parking Lot Tree Shading -In the Case of University of California Davis Parking Lot- (도시 주차장내 수목그늘의 경제적 이익 연구 -미국 캘리포니아 데이비스 대학 주차장을 사례로-)

  • Jang Dong-Su;McPherson E. G.
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.6 s.113
    • /
    • pp.98-108
    • /
    • 2006
  • The climate of urban area is an unstable type with considerable seasonal variation in precipitation wind speed, and temperature and it grows worse. Besides, ozone is a serious air pollutant in most of large cities. So worldwide, some of large cities are investing in forestry options to offset their climate problems, but lack of information has hindered comparisons of urban un cost effectiveness to other options. This research intends to study the economic benefits of tree shading of 19 parking lots in UCD campus. The economic benefits of tree shading are air conditioning savings, air quality, stormwater run-off, and other benefits. Especially, this study focuses how much the economic benefit of parking lot shading has been increased from 1995 to 2003 year by aerophoto. Some data on dimensions of parking lots and the number, size, tree species, and location of trees around each parking lot was inventoried. Two aerophotos(1995,2003) were used in order to analyze the increasement of tree canopy in 19 parking lots for 8 years. However, increasing coverage of trees and managing them for healthy growth would not be sufficient for avoiding adverse impacts by future climate change. Additional measures should be followed such as an increase of energy use efficiency and development of substitute energy. For example, coverage of trees help to save cooling energy by blocking solar radiation reaching parking cars and building structures through shading, and creating cool micro-climates through evapotranspiration. They also reduce heating demand by decreasing air infiltration and heat conduction out of the interior of buildings. Proper arrangement of vegetation over the parking lots can reduce cooling and heating costs. So proper planting design around hard space paving including species selection and location can significantly save cooling and heating energy. And a reduction in car and building's heating and cooling costs results in the reduction in energy demand which causes to emissions of air pollutants. Total increased tree canopy from 1995 to 2003 is $8,470.45m^2$ and the economic benefits is US$ 5,282.10. The economic benefit of one tree has been US$ 7.21 for 8 years. And an annually increased benefit is US$ 0.9 per a tree. If this kind of study is applied to studying the economic benefits of tree canopy in parking lots of Korea, it could result in guidelines of tree planting of parking lots. Because the trees selected for planting in parking lots were not suitable for an environment, the guidelines should contain a recommended list of trees. The guidelines should propose the shading percentage of parking lot when we plan a parking lot and contain the maintenance of trees in order to maximize the economic benefits of tree canopy.

Vulnerability Assessment to Urban Thermal Environment for Spatial Planning - A Case Study of Seoul, Korea - (공간계획 활용을 위한 도시 열환경 취약성 평가 연구 - 서울시를 사례로 -)

  • Eum, Jeong-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.4
    • /
    • pp.109-120
    • /
    • 2016
  • This study aims to assess vulnerability in urban thermal environments of Seoul by using indicators frequently used in previous studies as well as effective indicators for spatial planning like urban and environmental planning. For this purpose, fifteen indicators that influence urban thermal environments such as heat waves, urban heat island effects, and urban micro-climates were identified based on literature reviews. Indicators for presenting urban structure and spatial properties were included; for example, building volume as 'exposure to climate', buildings completed before 1980 as 'sensitivity', and green space areas as 'adaptive capacity'. Among them, twelve indicators were applied to assess vulnerability in urban thermal environments of Seoul by using a GIS spatial analysis combined with fuzzy logic. The results show that the Gangnam area is identified as more vulnerable to a heat environment as compared to the Gangbuk area. In the Gangnam area, Seocho-gu, Gangnam-gu, Dongjak-gu, Yeongdeungpo-gu, Gangseo-gu were relatively high in vulnerability, while Dongdaemun-gu, Gangbuk-gu, Gwangjin-gu, Jungrang-gu were relatively high in the Gangbuk area. Gwanak-gu, Dobong-gu, Eunpyeong-gu, and Nowon-gu, which include forested areas, have low vulnerability in the sectors of 'exposure to climate' and 'sensitivity' due to the impact of Gwanaksan and Bukhansan. However, some areas with high vulnerability like Seocho-gu and Gangnam-gu may have lower vulnerability if the indicator 'status of air conditioning' from the sector of 'adaptive capacity' is used. This study could support the establishment of a practicable thermal environment policy and spatial planning to reduce heat-related risks in the field of urban and environmental planning.

Environmental Monitoring Using Comfort Sensing System

  • Na, Dae-Suk;Kang, Jeong-Ho;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.24-33
    • /
    • 2003
  • This research is about a comfort sensing system for human environmental monitoring using a one-bodied humidity and temperature sensor and an air flow sensor. The thermal comfort that a human being feels in indoor environment has been known to be influenced mostly by six parameters, i.e. air temperature, radiation, air flow, humidity, activity level and clothing thermal resistance. Considering an environmental monitoring, we have designed and fabricated a one-bodied humidity and temperature sensor and an air flow sensor that detect air relative humidity, temperature and air flow in human environment using surface micromachining technologies. Micro-controller calculates a PMV (predicted mean vote) and CSV (comfort sensing vote) with sensing signals and display a PMV on LCD (liquid crystal display) for human comfort on indoor climate. Our work has demonstrated that a comfort sensing system can provide an effective means of measuring and monitoring the indoor comfort sensing index of a human being. Experimental results with simulated environment clearly suggest that our comfort sensing system can be used in many applications such as air conditioning system, feedback controlling in automobile, home and hospital etc..