• Title/Summary/Keyword: micro blood vessel

Search Result 27, Processing Time 0.034 seconds

Analysis and Experiment of Ultrasonic Vibration Mechanism using PZT Actuator for Precision Laser Machining (압전구동기를 이용한 정밀 가공용 초음파 진동장치 해석 및 실험)

  • Kim, Woo-Jin;Jeon, Yong-Ho;Cho, Sung-Hak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.12
    • /
    • pp.1347-1352
    • /
    • 2011
  • Recently, as the aged population grows around the world, many medical instruments, devices, and their fabrication processes are developing. Among the devices, a drug delivery stent is a good example for precision machining. Conventional drug delivery stent has problem of the remaining polymer because the drug is coated on the surface with it. If the drug is impregnated into the micro hole array on the stent surface, the polymer can be perfectly eliminated. Micro sized holes are generally fabricated by laser machining however, the fabricated holes do not have an enough aspect ratio to contain the drug or a good surface finish to deliver the stend to blood vessel tissue. To overcome these problems, we propose a vibration-assisted machining mechanism with PZT (Piezoelectric Transducers) for abrication of micro sized holes better. The results indicated that the burr size can be significantly decreased with vibration assisted in nanosecond pulse laser drilling test.

Analysis of Blood pressure influence factor Correction for Photoplethysmography Fusion Algorithm Calibration (광전용적맥파 융합 알고리즘 보정을 위한 혈압 영향인자 상관관계 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.67-73
    • /
    • 2019
  • The blood pressure measurement is calculated as a value corresponding to the pressure of the blood vessel using the pressure from the outside for a long time. Due to the recent miniaturization of measurement equipment and the ICT combination of personal healthcare systems, a system that enables continuous and real-time measurement of blood pressure with a sensor is required. In this study, blood pressure was measured using pulse transit time using Photoplethysmography. In this study, blood pressure was estimated by using systolic blood pressure. And it is possible to make measurement only with PPG itself, which can contribute to making a micro blood pressure measuring device. As a result, systolic blood pressure and PPG's S1-P and P-S2 were used to analyze the possibility of blood pressure estimation.

In vivo quantification of mandibular bone remodeling and vascular changes in a Wistar rat model: A novel HR-MRI and micro-CT fusion technique

  • Song, Dandan;Shujaat, Sohaib;Zhao, Ruiting;Huang, Yan;Shaheen, Eman;Van Dessel, Jeroen;Orhan, Kaan;Velde, Greetje Vande;Coropciuc, Ruxandra;Pauwels, Ruben;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.199-208
    • /
    • 2020
  • Purpose: This study was performed to introduce an in vivo hybrid multimodality technique involving the coregistration of micro-computed tomography (micro-CT) and high-resolution magnetic resonance imaging (HR-MRI) to concomitantly visualize and quantify mineralization and vascularization at follow-up in a rat model. Materials and Methods: Three adult female rats were randomly assigned as test subjects, with 1 rat serving as a control subject. For 20 weeks, the test rats received a weekly intravenous injection of 30 ㎍/kg zoledronic acid, and the control rat was administered a similar dose of normal saline. Bilateral extraction of the lower first and second molars was performed after 10 weeks. All rats were scanned once every 4 weeks with both micro-CT and HR-MRI. Micro-CT and HR-MRI images were registered and fused in the same 3-dimensional region to quantify blood flow velocity and trabecular bone thickness at T0 (baseline), T4 (4 weeks), T8 (8 weeks), T12 (12 weeks), T16 (16 weeks), and T20 (20 weeks). Histological assessment was the gold standard with which the findings were compared. Results: The histomorphometric images at T20 aligned with the HR-MRI findings, with both test and control rats demonstrating reduced trabecular bone vasculature and blood vessel density. The micro-CT findings were also consistent with the histomorphometric changes, which revealed that the test rats had thicker trabecular bone and smaller marrow spaces than the control rat. Conclusion: The combination of micro-CT and HR-MRI may be considered a powerful non-invasive novel technique for the longitudinal quantification of localized mineralization and vascularization.

Angiogenesis in newly regenerated bone by secretomes of human mesenchymal stem cells

  • Katagiri, Wataru;Kawai, Takamasa;Osugi, Masashi;Sugimura-Wakayama, Yukiko;Sakaguchi, Kohei;Kojima, Taku;Kobayashi, Tadaharu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.8.1-8.8
    • /
    • 2017
  • Background: For an effective bone graft for reconstruction of the maxillofacial region, an adequate vascular network will be required to supply blood, osteoprogenitor cells, and growth factors. We previously reported that the secretomes of bone marrow-derived mesenchymal stem cells (MSC-CM) contain numerous growth factors such as insulin-like growth factor (IGF)-1, transforming growth factor $(TGF)-{\beta}1$, and vascular endothelial growth factor (VEGF), which can affect the cellular characteristics and behavior of regenerating bone cells. We hypothesized that angiogenesis is an important step for bone regeneration, and VEGF is one of the crucial factors in MSC-CM that would enhance its osteogenic potential. In the present study, we focused on VEGF in MSC-CM and evaluated the angiogenic and osteogenic potentials of MSC-CM for bone regeneration. Methods: Cytokines in MSC-CM were measured by enzyme-linked immunosorbent assay (ELISA). Human umbilical vein endothelial cells (HUVECs) were cultured with MSC-CM or MSC-CM with anti-VEGF antibody (MSC-CM + anti-VEGF) for neutralization, and tube formation was evaluated. For the evaluation of bone and blood vessel formation with micro-computed tomography (micro-CT) and for the histological and immunohistochemical analyses, a rat calvarial bone defect model was used. Results: The concentrations of IGF-1, VEGF, and $TGF-{\beta}1$ in MSC-CM were $1515.6{\pm}211.8pg/mL$, $465.8{\pm}108.8pg/mL$, and $339.8{\pm}14.4pg/mL$, respectively. Tube formation of HUVECs, bone formation, and blood vessel formation were increased in the MSC-CM group but decreased in the MSC-CM + anti-VEGF group. Histological findings suggested that new bone formation in the entire defect was observed in the MSC-CM group although it was decreased in the MSC-CM + anti-VEGF group. Immunohistochemistry indicated that angiogenesis and migration of endogenous stem cells were much more abundant in the MSC-CM group than in the MSC-CM + anti-VEGF group. Conclusions: VEGF is considered a crucial factor in MSC-CM, and MSC-CM is proposed to be an adequate therapeutic agent for bone regeneration with angiogenesis.

Methods of The Promoting Blood Circulation and Removing Blood Stasis by Wang Cheong-Im (왕청임(王淸任)의 활혈거어법(活血祛瘀法))

  • Kim Hya-Sung;Jung Seung-Woo;Lee Jong-Il;Kwon Dong-Yeul
    • Herbal Formula Science
    • /
    • v.12 no.2
    • /
    • pp.47-55
    • /
    • 2004
  • Wang Cheong-Im(1768-1831) in the Ching dynasty conducted the therapy of blood statis syndrome using the methods for promoting blood circulation and removing blood statis in accordance with the description in the book Uirimgaechak(醫林改錯). Thus, this study examined his methods for promoting blood circulation and removing blood statis, therapy of blood statis syndrome and mechanism of function. Since the blood statis symptoms varied on the parts where the blood statis were occurred, the therapy for promoting blood circulation and removing blood statis applied different treatments and drugs depending on the symptoms. The therapy also valued much of qi and blood. Qi is important to the human body so that the therapy replenished qi and simultaneously promoted the blood circulation as mainly focusing on the regulation of the qi flow. Moreover, the therapy adjusted the level of removing blood circulation and rate of replenishing qi. The degree of prescription and drug was differentiated in treating a variety of blood statis because of the difference in the seriousness and characteristics of blood circulation, amount and application of drug and combination of drugs. The therapy was careful about the regulation of qi for the replenishment of qi and the nurishment of blood for the promotion of blood circulation. If the blood circulation was blocked, the blood statis was formed. Accordingly, the phlegm and the blood statis were closely related. Then, the phlegm and blood statis were simultaneously treated. The therapy divided the properties of blood statis into the stagnant excess syndrome, the stagnant deficiency syndrome, the stagnant cold syndrome and the stagnant heat syndrome and treated the patients suitable for each symptom. The function of mechanism in the treatment using the methods for promoting blood circulation and removing blood statis was divided into the stagnation of blood and interruption in blood circulation. The therapy laid stress on promoting blood circulation and removing blood circulation. With such emphasis, the therapy facilitated the circulation in the bloood vessel, prevented the coagulation of blood, removed the blood statis and promoted the metabolism. Then, the physiological function and pathological change internal organs were improved. Furthermore, the therapy strengtened the heart and promoted the blood circulation by improving the systemic blood circulation. Moreover, the therapy facilitated the micro-circulation by adjusting the balance of body.

  • PDF

In vivo Imaging Flow Cytometer (세포 이미징 기능을 겸비한 생체 유세포 분석기)

  • Lee, Ho
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.1
    • /
    • pp.9-11
    • /
    • 2007
  • We introduce an in vivo imaging flow cytometer, which provides fluorescence images simultaneously with quantitative information on the cell population of interest in a live animal. As fluorescent cells pass through the slit of light focused across a blood vessel, the excited fluorescence is confocally detected. This cell signal triggers a strobe beam and a high sensitivity CCD camera that captures a snap-shot image of the cell as it moves down-stream from the slit. We demonstrate that the majority of signal peaks detected in the in vivo flow cytometer arise from individual cells. The instrument's capability to image circulating T cells and measure their speed in the blood vessel in real time in vivo is demonstrated. The cell signal irradiance variation, clustering percentage, and potential applications in biology and medicine are discussed.

Protein Fraction Extracted from the Earthworm Lumbricus rubellus Activates Proteinase Activated Receptor-2 and is Effective on Hemokinesis (적토룡 추출 단백분획의 프로테나제 유도 수용체-2의 활성화 및 형행개선 효과)

  • Lee, Chul-Kyu;Shin, Jang-Sik;Choi, Young-Keun;Lim, Chae-Kon;Cho, Il-Hwan;Kim, Chul
    • YAKHAK HOEJI
    • /
    • v.41 no.2
    • /
    • pp.247-254
    • /
    • 1997
  • The proteinase-activated receptor (PAR-2) belongs to the family of seven transmembrane region receptors, like the thrombin receptor, it is activated by specific proteolytic clea vage of its extracellular amino terminus and a synthetic peptide (SLIGRL). The earthworm protein fraction (EPF) extracted from Lumbricus rubellus elicted dose- and endothelium-dependent relaxations in phenylephrine-contracted rat thoracic aorta, whereas heat inactivated EPF (0.5 ${\mu}g$ /ml) had no effect. In the presence of the nitric oxide synthase inhibitor NG-methyl-L-arginine (1.8 micro M), EPF (0.5 ${\mu}g$ /ml)-induced relaxations were partially inhibited. Furthermore, EPF (0.5 ${\mu}g$ /ml) dramatically caused relaxation of thrombin-desenstized rat thoracic aorta. These results indicate that EPF activates PAR-2 in vascular endothelial cell. Intravenous injection of EPF (20 mg/kg, bolus) into anesthetized rats produced a marked depressor response. EPF (0 ~ 80 ${\mu}g$ /ml, gradient) was very effective on increasing of perfusion volume in rabbit ear vessel preparations. These results imply the usefulness of EPF as a vascular smooth muscle relaxant and indicate that the activation of PAR-2 may be a mechanism of EPF on hemokinetic improvement.

  • PDF

Laser Speckle Imaging Using Laser Speckle Endoscope (레이저 스펙클 내시경을 이용한 미세혈관 영상화 기법)

  • Jin, Ho-Young;Shin, Hyun-Chool
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.6
    • /
    • pp.91-96
    • /
    • 2010
  • A laser speckle is a random pattern that has a granular appearance produced by reflected light when a coherent laser illuminates an irregular course surface. Laser speckle system has many advantages. It can detect some animals functional parts. Moreover, it relatively consists of simple and in-expensive system. It is very important that detecting micro-vessels through image processed image. Current study is to improve image quality through variable image processing method. But this paper made laser speckle endoscope for miniaturization and commercialization laser speckle system. We had endoscope test through goldfish's tail. We will compare the processed speckle image and halogen image.

Magnet Location Estimation Technology in 3D Using MI Sensors (MI센서를 이용한 3차원상 자석 위치 추정 기술)

  • Ju Hyeok Jo;Hwa Young Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.232-237
    • /
    • 2023
  • This paper presents a system for estimating the position of a magnet using a magnetic sensor. An algorithm is presented to analyze the waveform and output voltage values of the magnetic field generated at each position when the magnet moves and to estimate the position of the magnet based on the analyzed data. Here, the magnet is sufficiently small to be inserted into a blood vessel and has a micro-magnetic field of hundreds of nanoteslas owing to the small size and shape of the guide wire. In this study, a highly sensitive magneto-impedance (MI) sensor was used to detect these micro-magnetic fields. Nine MI sensors were arranged in a 3×3 configuration to detect a magnetic field that changes according to the position of the magnet through the MI sensor, and the voltage value output was polynomially regressed to specify a position value for each voltage value. The accuracy was confirmed by comparing the actual position value with the estimated position value by expanding it from a 1D straight line to a 3D space. Additionally, we could estimate the position of the magnet within a 3% error.

New Surgical Technique for Harvesting Proximal Fibular Epiphysis in Free Vascularized Epiphyseal Transplantation (혈관부착 근위비골성장판 이식시 공여부 수술의 새로운 술식)

  • Chung, Duke-Whan
    • Archives of Reconstructive Microsurgery
    • /
    • v.5 no.1
    • /
    • pp.106-111
    • /
    • 1996
  • Purpose : Propose a surgical technique in donor harvesting method in free vascularized proximal fibular epiphysis. Methodology : Concerned about growth potentials of the transplanted epiphysis in our long term results of the epiphyseal transplanted 13 cases more than 4 years follow-up, anterior tibial artery which contains anterior tibial recurrent artery is most reliable vessel to proximal fibular epiphysis which is the best donor of the free vascularized epiphyseal transplantation. In vascular anatomical aspect proximal fibular epiphysis norished by latearl inferior genicular artery from popliteal, posterior tibial recurrent artery and anterior tibial recurrent artery from anterior tibial artery and peroneal artery through metaphysis. The lateral inferior genicular artery is very small and difficult to isolate, peroneal artery from metaphysis through epiphyseal plate can not give enough blood supply to epiphysis itself. The anterior tibial artery which include anterior tibial recurrent and posterior tibial recurrent artery is the best choice in this procedure. But anterior tibial recurrent artery merge from within one inch from bifucating point of the anterior and posterior tibial arteries from popliteal artery. So it is very difficult to get enough vascular pedicle length to anastomose in recipient vessel without vein graft even harvested from bifucating point from popliteal artery. Authors took recipient artery from distal direction of anterior tibial artery after ligation of the proximal popliteal side vessel, which can get unlimited pedicle length and safer dissection of the harvesting proximal fibular epiphysis. Results : This harvesting procedure can performed supine position, direct anterolateral approach to proximal tibiofibular joint. Dissect and isolate the biceps muscle insertion from fibular head, micro-dissection is needed to identify the anterior tibial recurrent arteries to proximal epiphysis, soft tissue release down to distal and deeper plane to find main anterior tibial artery which overlying on interosseous membrane. Special care is needed to protect peroneal nerve damage which across the surgical field. Conclusions : Proximal fibular epiphyseal transplantation with distally directed anterior tibial artery harvesting technique is effective and easier dissect and versatile application with much longer arterial pedicle.

  • PDF