• Title/Summary/Keyword: micro analysis

Search Result 3,990, Processing Time 0.034 seconds

Study on Torque Analysis of Micro-Electromagnetic Clutch by Using FEM (FEM을 이용한 Micro-Electromagnetic Clutch 토크해석)

  • Piao Changhao;Cho Chongdu;Kim Myunggu;Pan Qiang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.2
    • /
    • pp.60-65
    • /
    • 2005
  • This study tries to analyzes the static friction torque that generated in a micro-electromagnetic clutch by using FEM. For the purpose of design change and optimization of the micro-electromagnetic clutch, the static friction torque prediction is very important. We construct the axi symmetric FEM model for analyze the static friction torque and the real material properties are substituted to the FEM model. For a test, predicted static friction torque is compared with experimental one to discuss the rationality of torque analysis process. The analytical result agrees well to experimental data. explaining the validity of the mathematical process and FEM model.

Transient Heat Transfer Analysis on the Evaporator of a Micro-Cooler prior to Roiling (마이크로 쿨러 증발기의 비등 전 과도열전달 해석)

  • Park, Byeong-Gyu;Kim, Geun-O
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.211-218
    • /
    • 2002
  • It has been investigated for the temperature profile in a planar evaporator of micro-cooler subject to a uniform heat flux prior to tole initiation of boiling. The results of the analysis allow for the determination of applied power levels fur which nucleation is likely to occur only within the vapor grooves of the evaporator while maintaining subcooling in the liquid core, thereby increasing the likelihood of a successful startup. Also, limits are fecund for which additional increases in the applied heat flux do not increase the temperature difference between the vapor grooves and the wick-liquid core interface. This analysis is appropriate for the microscale evaporators of micro-cooler during a fully-flooded startup as well as starter pump designs and micro-CPLs(capillary pumped loops). The results are useful in the initial basic design of microscale heat transfer devices.

MCST bending formulation of a cylindrical micro-shell based on TSDT

  • Mohammad Arefi
    • Earthquakes and Structures
    • /
    • v.26 no.4
    • /
    • pp.299-309
    • /
    • 2024
  • The present paper develops application of third-order shear deformation theory (TSDT) and modified couple stress theory (MCST) to size-dependent bending analysis of a functionally graded cylindrical micro-shell. The radial and axial displacement components are described based on TSDT for more accurate analysis. The effect of small scales is accounted based on MCST. The principle of virtual work is used for derivation of bending governing equations. The solution is presented for a simply-supported boundary condition to account the influence of various important parameters such as micro length scale parameter, in-homogeneous index and some dimensionless geometric parameters such as length to radius and length to thickness ratios on the bending results. A comparative analysis is presented to examine the effect of order of employed shear deformation theory on the axial and radial displacements.

Limited Diagnostic Value of microRNAs for Detecting Colorectal Cancer: A Meta-analysis

  • Zhou, Xuan-Jun;Dong, Zhao-Gang;Yang, Yong-Mei;Du, Lu-Tao;Zhang, Xin;Wang, Chuan-Xin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4699-4704
    • /
    • 2013
  • Background: MicroRNAs have been demonstrated to play important roles in the development and progression of colorectal cancer. Several studies utilizing microRNAs as diagnostic biomarkers for colorectal cancer (CRC) have been reported. The aim of this meta-analysis was to comprehensively and quantitatively summarize the diagnostic value of microRNAs for detecting colorectal cancer. Methods: We searched PubMed, Embase and Cochrane Library for published studies that used microRNAs as biomarkers for the diagnosis of colorectal cancer. Summary estimates for sensitivity, specificity and other measures of accuracy of microRNAs in the diagnosis of colorectal cancer were calculated using the bivariate random effects model. A summary receiver operating characteristic (SROC) curve was also generated to summarize the overall effectiveness of the test. Result: Thirteen studies from twelve published articles met the inclusion criteria and were included. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odd ratio of microRNAs for the diagnosis of colorectal cancer were 0.81 (95%CI: 0.79-0.84), 0.78 (95%CI: 0.75-0.82), 4.14 (95%CI: 2.90-5.92), 0.24 (95%CI: 0.19-0.30), and 19.2 (95%CI: 11.7-31.5), respectively. The area under the SROC curve was 0.89. Conclusions: The current evidence suggests that the microRNAs test might not be used alone as a screening tool for CRC. Combining microRNAs testing with other conventional tests such as FOBT may improve the diagnostic accuracy for detecting CRC.

Vibration Analysis of 1″ Micro Storage (1″ 마이크로 스토리지의 진동특성 분석에 관한 연구)

  • W. S. Han;M. P. Hong;Y. K. Byun;J. S. Ko
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.339.2-339
    • /
    • 2002
  • In recent years, the demand of mobile device, such as digital camera, camcoder and PDA, increases remarkably. So, requirements of the mobile information data storage used in the mobile devices increase noticeably also. 1" micro storage is a kind of mobile storage, which has a CF type II form factor, and the similar structure of the general 3.5" HDD. In this paper, we performed the vibration analysis and experimental study of disk-spindle system in 1 " micro storage, such as measurement of the NRRO of the disk, and modal analysis. (omitted)

  • PDF

A Study on the Improving Diaphgram for Micro Speaker Performance using Taguchi Method (다구찌법을 이용한 마이크로 스피커용 다이아프램의 성능개선에 관한 연구)

  • Hong, D.K.;Woo, B.C.;Ahn, C.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.534-538
    • /
    • 2004
  • On this study, we improved diaphgram for micro speaker performance using Taguchi method in discrete design space. The design of diaphgram has an effect on performance of micro speaker such as, thickness of diaphgram, shape of diaphgram, etc. Therefore this study carried to decide shape of diaphgram and thickness of diaphgram for minimizing 2nd natural frequency of diaphgram using Taguchi method. we showed improved design factors that minimized 2nd natural frequency of diaphgram. Also, 2nd natural frequency of diaphgram for micro speaker is reduced up to 37 percent maintaining twist mode shape. From the results of ANOVA, 2nd natural frequency of diaphgram for micro speaker have an effect on position of the outer curved shape and thickness of diaphgram.

  • PDF

Shape Optimization of a Micro-Static Mixer (마이크로 믹서의 형상 최적화)

  • 한석영;김성훈
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.166-171
    • /
    • 2004
  • In this study, shape optimization of micro-static mixer with a cantilever beam was accomplished for mixing the mixing efficiency by using successive response surface approximations. Variables were chosen as the length of cantilever beam and the angle between horizontal and the cantilever beam. Sequential approximate optimization method was used to deal with both highly nonlinear and non-smooth characteristics of flow field in a micro-static mixer. Shape optimization problem of a micro-static mixer can be divided into a series of simple subproblems. Approximation to solve the subproblems was performed by response surface approximation, which does not require the sensitivity analysis. To verify the reliability of approximated objective function and the accuracy of it, ANOVA analysis and variables selection method were implemented, respectively. It was verified that successive response surface approximation worked very well and the mixing efficiency was improved very much comparing with the initial shape of a micro-static mixer.

  • PDF

The Development of Micro Milling Machine (초소형 밀링머신 개발)

  • Hwang J.;Chung E.S.;Cox Danel;Liang StevenY.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1171-1174
    • /
    • 2005
  • Manufacturing capability at the micro or nano scale production field is requested strongly in view of parts and product miniaturization. Miniaturized parts and products will introduce lots of benefits in terms of high precision functionality and low energy consumption. This paper presents the results of micro milling machine tool development for micro machining process. Finite element analysis has been performed to know the relationship between design dimensional variables and structural stiffness in terms of static, dynamic, thermal aspects. Performance evaluation through machining has been tested and discussed for achievable machining characteristics.

  • PDF

Micro-factory Evaluation through Digital Assembly Simulation (디지털 조립 시뮬레이션에 의한 초소형 공작기계 평가)

  • Choi, Sung-Il;Jung, Young-Sang;Subramaniyam, Murali;Jang, Seok-Ho;Song, Joon-Yub;Park, Sang-Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.78-83
    • /
    • 2007
  • In this paper, the digital model of the micro-factory has been established, inspected and evaluated by progress of assembly, manipulation and examination. The new paradigm of the system analysis is realized by digital simulation of the factory. The digital manufacturing system of the micro-factory was simulated through UML(Unified Modeling Language) with the object-oriented logical model analysis method and then the micro lens module assembly system was simulated with MST(Micro System Technology) Application Module.

A Study on Performance Improvement of Diaphgram for Micro Speaker using Table of Orthogonal Array (직교배열표를 이용한 마이크로 스피커용 다이아프램의 성능개선에 관한 연구)

  • 홍도관;우병철;안찬우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.162-165
    • /
    • 2004
  • On this study, we improved diaphgram for micro speaker performance using Taguchi method in discrete design space. The design of diaphgram has an effect on performance of micro speaker such as, thickness of diaphgram, shape of diaphgram, etc. Therefore this study carried to decide shape of diaphgram and thickness of diaphgram for minimizing 2nd natural frequency of diaphgram using Taguchi method. we showed improved design factors that minimized 2nd natural frequency of diaphgram. Also, 2nd natural frequency of diaphgram for micro speaker is reduced up to 37 percent maintaining twist mode shape. From the results of ANOVA, 2nd natural frequency of diaphgram for micro speaker have an effect on position of the outer curved shape and thickness of diaphgram.

  • PDF