• Title/Summary/Keyword: micro Pump

Search Result 186, Processing Time 0.033 seconds

Effect of hematocrit on hemorheological characteristics of blood flow in a microtube (헤마토크릿에 따른 혈액의 유변학적 특성 변화)

  • Ji, Ho-Seong;Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.111-112
    • /
    • 2006
  • In order to investigate flow characteristics of blood flow in a micro tube ($100{\mu}m$ in diameter) according to hematocrit, in-vitro experiments were carried out using a micro-PIV technique. The micro-PIV system consists of a microscope, a 2 head Nd:YAG laser, a 12 bit cooled CCD camera and a delay generator. Blood was supplied into the micro tube using a syringe pump. Hematocrit of blood was controlled to be 20%, 30% and 40%. The blood flow has a cell free layer near the tube wall and its thickness was changed with increasing the flow rate and hematocrit. The hemorheological characteristics such as shear rate and viscosity were evaluated using the velocity field data measured. As the flow rate increased, the blunt velocity profile in the tube center was sharpened. The viscosity of blood was rapidly increased with decreasing shear rate, especially in the region of low shear rate, changing RBC rheological properties. The variation of velocity profile and blood viscosity shows typical characteristics of Non-Newtonian fluids. On the basis of inflection points, the cell free layer and two-phase flow consisting of plasma and suspensions including RBCs were clearly discriminated.

  • PDF

Flotation Efficiency of the DAF Pump System for Mixing and Coagulation Conditions in Raw Drinking Water (상수원수의 혼화 및 응집 조건에 따른 DAF pump 장치의 부상분리효율)

  • Ahn, Kab-Hwan;Lee, Chang-Han
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.639-645
    • /
    • 2011
  • This study found that flotation efficiencies for removing algae and micro particles in raw water were optimized on mixing intensity and time of the mixing and flocculation conditions with a continuous DAF system. It is more efficient for mixing intensity at 23.1 $s^{-1}$ and time at 660 s(Gt value : 15246) to float flocculated floc with the raw water in M water treatment plant. Flotation efficiency was more than about 0.9 when operated pressure and A/S ratio were sustained at 5 $kg_f{\cdot}cm^{-2}$ and up to 0.056 $mL{\cdot}mg^{-1}$. The continuous DAF system made by the study could be continuously operated for 20 days and sustained not exceeding 4 NTU with raw water with low turbidity(13.4~9.8 NTU).

A study on thermal conductivities of rocks in Korea (한국의 암석 열전도도에 관한 연구)

  • Park, Jeong-Min;Kim, Hyoung-Chan;Lee, Young-Min;Song, Moo-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.449-451
    • /
    • 2007
  • We made 980 thermal conductivity measurements on igneous, metamorphic, sedimentary, and volcanic rock samples from Korea. The average thermal conductivity of igneous, metamorphic, sedimentary, and volcanic rocks are 3.41 W/m-K, 3.98 W/m-K, 4.10 W/m-K, and 3.21 W/m-K, respectively. Thermal conductivity values of a rock type generally have a wide range because thermal conductivity depends on various factors such as dominant mineral phase, micro-structure, anisotoropy and so on. Thermal properties (thermal conductivity, thermal diffusivity and specific heat) are important variables which are used to design a geothermal heat pump(GHP) system. Therefore, our thermal property data can contribute on a efficient design of a GHP system.

  • PDF

Vibration analysis of valveless Type Piezoelectric micro-pump by using ATILA (ATILA를 이용한 진행파 회전형 밸브리스 압전펌프의 진동 해석)

  • Lim, Jong-Nam;Oh, Jin-Heon;Park, Cheol-Hyun;Lim, Kee-Joe;Kim, Hyun-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.215-216
    • /
    • 2008
  • Using the extensional vibration mode of PZT ring, a piezopump is successfully made. The PZT ring is polarized with thickness direction. The traveling extensional wave along the circumference of the ring is obtained by dividing two standing waves which are temporally and spatially phase shifted by 90 degrees from each other. The proposed piezopump is consisted of coaxial cylindrical shells that are bonded piezoelectric ceramic ring.

  • PDF

A Fabrication and Experiment of Induction-type EHD Micropump with Temperature Gradient (온도차를 이용한 유도형 마이크로 EHD 펌프의 제작 및 실험)

  • Youn, Yong-Kyu;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.198-200
    • /
    • 1993
  • This paper represents the experimental results of electrohrdrodynamic(EHD) micropump driven by traveling- wave voltage. We fabricated 60 electrodes array with $100{\mu}m$ width and $100{\mu}m$ interval on the pyrex glass. On that glass we fabricated the micro channel which had the cross section of 3mm by 0.5mm. This pump was driven by 6 phase square traveling-wave voltage. We used the corn oil for experiments and increased the temperature of fluid by resistive heater. An optical microscope with CCD camera and monitor was used for observation. The fluid velocity was large for the large driving voltage and the high temperature. This EHD pump had the fluid velocity in specific frequency (near 1Hz) which had relation to the charge relaxation time in that oil.

  • PDF

Computer Testing System for Pumps

  • Xiao, Chongren
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.598-606
    • /
    • 1996
  • Computer testing system for pumps is an automatic measuring and testing system micro computer. There are two functions to this system. 1. Automatically controlling the testing processes. It includes controlling to testing devices, adjusting test points and starting or stopping the pump. 2. Automatically collecting and calculating the testing data. It includes the collection and calculation of the parameters to be measured, printing the testing reports and plotting the testing curves. When using it the measuring accuracy may be improved and the time for testing may be compressed by use the system . So it is used widely on the world. In this paper the basic construction and the work principle and the testing processes are described.

  • PDF

Changes of Blood pH in Micro-circulation System on the Stimulated Time of Pulsed Magnetic Fields (펄스자기장 자극 시간에 따른 미세순환시스템 내에서 혈액의 pH변화)

  • Lee, Boram;Choi, Yukyung;Lee, Hyunsook
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.214-218
    • /
    • 2022
  • The purpose of this study was to investigate the role of the PMF in the treatment of acidosis and inflammation by monitoring the pH change for the continuity of PMF effect on the blood in the micro-circulation system that mimics the capillaries in the human body. Micro-tubes and micro-channels similar in diameter to those of arteries and arterioles were fabricated using PDMS and connected to a micro-pump for blood circulation. The continuity of PMF effect was verified in a micro-circulation system in-vitro. The pH changes for the circulating blood and for persistence time of PMF stimulus effect were confirmed using the optimized PMF conditions based on the previous studies. Also pH changes were observed by continuously stimulating PMF for a set period of time. The result was observed that the pH of the blood acidified using tBHP continued to rise from immediately after stimulation of PMF to 70 minutes of stimulation, reaching a normal pH range, and then decreasing. Our study showed that PMF has a positive effect on the control of blood pH homeostasis, so it is suggested the possibility of being used as a noninvasive treatment for acidosis treatment and anti- inflammatory treatment.

Numerical Analysis on Thermal Transpiration Flows for a Micro Pump (열천이 현상을 이용한 마이크로 펌프내의 희박기체유동 해석)

  • Heo, Joong-Sik;Lee, Jong-Chul;Hwang, Young-Kyu;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.493-496
    • /
    • 2006
  • Rarefied gas flows through two-dimensional micro channels are studied numerically for the performance optimization of a nanomembrane-based Knudsen compressor. The effects of the wall temperature distributions on the thermal transpiration flow patterns are examined. The flow has a pumping effect, and the mass flow rates through the channel are calculated. The results show that a steady one-way flow is induced for a wide range of the Knudsen number. The DSMC(direct simulation Monte Carlo) method with VHS(variable hard sphere) model and NTC(no time counter) techniques has been applied in this work to obtain numerical solutions.

  • PDF

PIV Measurements of the Pressure Driven Flow Inside a T-Shaped Microchannel (T형 마이크로채널 내부 압력구동 유동의 PIV 계측)

  • Choi Jayho;Lee In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.423-426
    • /
    • 2002
  • A custom micro-PIV optics assembly has been used to measure the flow field inside a T-shaped microchannel. The micro-PIV system consists of microscope objectives of various magnifications, a dichroic cube, and an 8-bit CCD camera. Fluorescent particles of diameters 620nm have been used with a Nd:YAG laser and color filters. A programmable syringe pump with Teflon tubings were used to inject particle-seeded distilled water into the channel at flow rates of $420,\;40,\;60{\mu}L/hr$. The microchannels are fabricated with PDMS with a silicon mold, then $O_2-ion$ bonded onto a slide glass. Results show differences in flow characteristics and resolution according to fluid injection rates, and magnifications, respectively. The results show PIV results with vector-to-vector distances of $2{\mu}m$ with 32 pixel-square interrogation windows at $50{\%}$ overlap.

  • PDF

Fabrication of a Micro fluidic Lens having variable focal length (가변 초점거리 마이크로 유체렌즈 제작)

  • Lee J.S.;Park J.G.;Kim G.M.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.572-575
    • /
    • 2005
  • A microlens connected to microfluidic channel is fabricated. The microlens is sealed with an elastomeric membrane which deforms by pressure of fluid driven by a syringe pump resulting in the shape change of the microlens. The optical properties of the microlens could be controlled by changing the microlens shape. The microlens system were made of an elastomer, PDMS, using molding from a photoplastic master patterned by UV photolithography. The test results show the optical property of the lens could be made into convex and concave type by applying the fluidic pressure positive and negative.

  • PDF