• Title/Summary/Keyword: metrology

Search Result 722, Processing Time 0.028 seconds

Nondestructive Evaluation of Residual Life of 1Cr-1Mo-0.25V Steel from Reversible Magnetic Permeability

  • K.S. Ryu;S.H. Nahm;Kim, Y.I.;K.M. Yu;Kim, Y.B.;Cho, Y.;D. Son
    • Journal of Magnetics
    • /
    • v.6 no.1
    • /
    • pp.27-30
    • /
    • 2001
  • We present a new procedure to evaluate the residual life of 1Cr-1Mo-0.25V steel from reversible magnetic permeability. The method is based on the existence of first harmonics in the differential magnetization around the coercive force. The apparatus is based on the detection of the voltage induced in a coil using a lock-in amplifier tuned to the frequency of the exciting coil. Results obtained for the first harmonics and Vickers hardness on aged samples show that the peak interval of reversible permeability and Vickers hardness decrease as aging time increases. The correlation between Vickers hardness and the peak interval of the reversible permeability may be used to evaluate the residual life of 1Cr-lMo-0.25V steel, nondestructively.

  • PDF

Degradation Evaluation of Turbine Rotor Using Magnetic Method (자기적 방법에 의한 터빈 로터강의 열화도 평가)

  • Ryu, K.S.;Park, J.S.;Nahm, S.H.;Kim, Y.I.;Yu, K.M.;Ryu, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1593-1595
    • /
    • 2000
  • We present a new procedure to evaluate the degradation in a lCr-lMo-0.25V steel. The method is based on the existence of the peak of reversible permeability in the differential magnetization around the coercive field strength. The apparatus is based on the detection of the voltage induced in a surface type coil using a lock-in amplifier tuned to a frequency to the exciting one. Results obtained the reversible permeability and Vickers hardness on the annealed samples show the peak interval of reversible permeability and Vickers hardness decreased as ageing time increased. The correlation between Vickers hardness and the peak interval of reversible permeability could well be evaluated non destructively.

  • PDF

Formulation of a New En Score in the Proficiency Test

  • Chul-Young Yi;In Jung Kim;Jong In Park;Yun Ho Kim;Young Min Seong
    • Progress in Medical Physics
    • /
    • v.35 no.1
    • /
    • pp.16-19
    • /
    • 2024
  • A new En score of the proficiency test (PT) is formulated; it is applicable when a correlation exists between the reference and participant's values. Based on the uncertainty propagation rule given in ISO/IEC Guide 98-3 (GUM:1995), the En score covering the correlation case is newly developed for the PT. The new En score will be applied in a future PT organized by the Korea Research Institute of Standards and Science (KRISS) dosimetry team. The new En score will enhance measurement traceability and contribute to improving the quality management system of participants in the KRISS PT by avoiding performance underestimation.

Development of Surface Acoustic Wave Sensor for Viscosity Measurement of Low Viscose Liquid Using Love Wave (Love파를 이용한 저점성 유체 점도 측정용 표면 탄성파 센서 개발)

  • Lee, Sang-Dae;Kim, Ki-Bok;Lee, Dae-Su
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.282-287
    • /
    • 2008
  • Love wave is one of the shear horizontal waves and it can propagate between two layers in liquid without energy loss. The SAW (surface acoustic wave) sensor using Love wave is very useful for real time measurement of the viscosity of liquid with high sensitivity. In this study, the 77 MHz and 155 MHz Love wave SAW sensors were fabricated and use to measure the viscosity of low viscous liquid. To generate the surface acoustic wave, the inter-digital transducers were fabricated on the quartz crystal wafer. In order to obtain the optimal thickness of the coating film (novolac photoresist) generating the Love wave on the surface of SAW device, theoretical calculation was performed. The performances of fabricated Love wave SAW sensors were tested. As test liquid, pure water and glycerol solutions having different concentrations were used. Since the determination coefficients of the regression equations for measuring the viscosity of liquid are greater than 0.98, the developed Love wave SAW sensors in this study will be very useful for precise measurement of viscosity of liquid.

100 kN Deadweight Force Standard Machine and Evaluation

  • Park Yon-Kyu;Kim Min-Seok;Kim Jong-Ho;Kang Dae-Im;Song Hou-Keun
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.961-971
    • /
    • 2006
  • A deadweight force standard machine is a mechanical structure that generates force by subjecting deadweights to the local gravitational field. The Korea Research Institute of Standards and Science (KRISS) developed and installed a 100 kN deadweight force standard machine for national force standards. It can generate forces from 2 kN to 110 kN in increments of 1 kN. The uncertainty of the force machine was estimated and declared as $2\times10^{-5}$. This 100 kN deadweight force machine was compared with the 500 kN deadweight force standard machine at KRISS and the 20 kN and 50 kN deadweight force standard machines at the National Metrology Institute of Japan (NMIJ). The measurement results showed good agreement between the deadweight force machines, and the accuracy level of the 100 kN deadweight force machine was verified.

Design and Fabrication of a Step Height Certified Reference Material for Multi-probe Inspection Instruments (다중 프로브 검사 계측 장비를 위한 단차 표준 인증 물질의 설계 및 제작)

  • Maeng, Sae-Rom;Jin, Jong-Han;Buajarern, Jariya;Kim, Jae-Wan;Kim, Jong-Ahn;Kang, Chu-Shik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.323-329
    • /
    • 2011
  • Certified reference materials (CRMs) have been used to calibrate surface profilers for reliable measurements. In this paper, we present a newly designed step height CRM which has a step height pattern with two different widths and various special patterns for checking radial magnification, distortion of optical viewing systems, etc. Especially, it could be useful for multi-probe inspection instruments in the manufacturing lines. The fabrication was done by conventional optical lithography and dry etching process with optimized conditions. To verify the step height values, a white-light scanning interferometer was used with objective lenses having magnification of $10{\times}$ and $100{\times}$. CRMs with nominal step heights of $0.5\;{\mu}m$, $1\;{\mu}m$, $3\;{\mu}m$, $5\;{\mu}m$, $7\;{\mu}m$, and $10\;{\mu}m$ were fabricated and the uniformity of these CRMs was evaluated to be less than 3 nm ($1{\sigma}$).

Development of QCM dew point sensor and its sensing characteristics study (수정미소저울 노점센서 제작 및 반응특성 연구)

  • Kwon, Su-Yong;Kim, Jong-Chul;Choi, Byung-Il
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.269-276
    • /
    • 2006
  • This paper represents development of quartz crystal microbalance (QCM) and usage as a dew point sensor. The temperature of a quartz resonator was controlled precisely from $20^{\circ}C$ to $-30^{\circ}C$ with the ramping rate of $0.1^{\circ}C/s$ by using a custom-made crystal holder housing the quartz resonator associated with a thermoelectric cooler (Peltier cooler), which results in the working range from $15.2^{\circ}C$ to $-24.0^{\circ}C$ based on an accurate holder temperature compensation and temperature effect compensation process. The developed QCM dew point sensor and analysis techniques show very good sensing characteristics at measurement of moist air with the relative humidity from 10 %R.H. to 90 %R.H. generated by a divided-type humidity generator and the dew point temperatures were determined with an accuracy of less than ${\pm}0.18^{\circ}C$, which also showed good agreement with reference values in their error range.

Development of a Nutritional Supplement Certified Reference Material for Elemental Analysis

  • Lee, Jong Wha;Heo, Sung Woo;Kim, Hwijin;Lim, Youngran;Lee, Kyoung-Seok;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.9 no.4
    • /
    • pp.105-109
    • /
    • 2018
  • A certified reference material (CRM) for the analysis of inorganic nutrients in nutritional supplements has been developed. Accurate mass fractions of chromium (Cr), iron (Fe), copper (Cu), and zinc (Zn) were determined by isotope dilution inductively coupled plasma mass spectrometry (ID ICP/MS). The measurement results were used to assign certified values for the CRM, which were metrologically traceable to the definitions of the measurement units in the International System of Units (SI). Production of a candidate reference material (RM) and the certification processes are summarized. Each nutrient in the CRM showed good homogeneity, which was estimated using relative standard deviations of the measurement results of twelve bottles in a batch. This CRM is expected to be an important reference to improve reliability and comparability of nutrient analyses in nutritional supplements and related samples in analytical laboratories.

Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices (집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정)

  • Doh, Il;Joe, Daniel J.;Kim, Sung Mok;Baik, Kyung Min;Kim, Yong Tae;Park, Seung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

Improved Method and Message Structure Design for TWSTFT without Extra Network

  • Juhyun Lee;Ju-Ik Oh;Young Kyu Lee;Sung-hoon Yang;Jong Koo Lee;Joon Hyo Rhee
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.2
    • /
    • pp.201-209
    • /
    • 2023
  • Time comparison techniques are required for generating and keeping Coordinated Universal Time (UTC) and to distribute standard clocks. These techniques play an important role in various fields, including science, finance, military, and communication. Among these techniques, Two-Way Satellite Time and Frequency Transfer (TWSTFT) ensures a relatively high accuracy, with a time comparison accuracy at a nanosecond level. However, TWSTFT systems have some limitations, such as the dependency on extra network links. In this paper, we propose an improved method for TWSTFT system operation and design a message structure for the suggestion. Additionally, we estimate the data rate and redundancy for the new TWSTFT signal with the designed message structure.