• Title/Summary/Keyword: methylene-blue

Search Result 886, Processing Time 0.023 seconds

Effects of dye-guidance brushing etching technique on the performance of pits and fissures sealant (Dye-guidance와 brushing을 통한 산부식 방법이 치면열구전색술의 수복의 질에 미치는 영향)

  • Hung, Phan Ai;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.106-121
    • /
    • 2007
  • The purpose of this study was to examine the effects of suggested etching method on the performance of pits and fissures sealant. In the first part, seventy extracted sound human permanent third molars and premolars were used. The teeth were randomly divided and performed in three different groups as follows : conventional etching, enameloplasty, and testing group. Non-pumicing, dye-guidance vigorous brushing-start etching technique was applied on the occlusal of testing group. Then the pit and fissure sealant was applied on all of the specimens. After the thermocycling and immersing in 1% methylene blue, the resin embedded sections were made. The microleakage data on the section were then recorded under the stereoscope and statistic analysis was done. Additional experiments were also performed : direct fissure surface etched pattern experiment, replica study, and micro-shear bond strength testing observation. The second part included two groups. A paired study was designed to evaluate the influence the environment has on the performance of the sealant. After etching, half of each occlusal surface received one of the two following treatments in succession: sealing in laboratory and intraoral condition (group 1), sealing in intraoral condition with and without a single-bonding agent (group 2). The results of present study can be summarized as follows: - The microleakage of testing group was significant different with conventional method (P<.05) and was not different with the enameloplasty group (P>.05). - The quality and quantity of etched enamel were improved. - Microshear bond strength of testing group was higher than control group (p<.05). - The environmental condition was influenced on the performance of the sealant. The testing etching method modified the capacity of the etching agent to penetrate into the pits and fissures, and simultaneous enhance their efficiency in vitro condition.

  • PDF

Effect ot Radix Asteris on Airway Smooth Muscle (Airway Smooth Muscle에 미치는 자울의 효과)

  • Na Kyung-Sang;Kwon Eui-Kwang;Soo Yeung-Hyung;Suh Eun-Mi;Han Jong-Hyun
    • Korean Journal of Acupuncture
    • /
    • v.18 no.1
    • /
    • pp.157-164
    • /
    • 2001
  • Radix Asteris has been used in Korea for many centuries as a treatment for respiratory disease. The effect of Radix Asteris on tracheal smooth muscle is not known. The purpose of the present study is to determine the effect of Radix Asteris on histamine induced tracheal smooth muscle contraction in rats and guinea pigs. Guinea pig(500g, male) and Sprague Dawley rats (250g, male) were killed by $CO_2$ exposure and a segment (8-10mm) of the thoracic trachea from each rat and guinea pig was cut into equal segments and mounted 'in pairs' in a tissue bath. Contractile force was measured with force displacement transducers under 0.5g loading tension. The dose of histamine (His) which evoked 50% of maximal response ($ED_{50}$) was obtained from cumulative dose response curves for histamine $(10^{-7}{\sim}10^{-4}M)$. Contractions evoked by His ($ED_{50}$) were inhibited significantly by Radix Asteris. In guinea pig tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was 120.5% (p<0.01) after $100{\mu}l/ml$ Radix Asteris. In rat tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was 135.4% (p<0.01) after $100{\mu}l/ml$ Radix Asteris. Propranolol $(10^{-7}M)$ slightly but significantly attenuated the inhibitory effects of Radix Asteris. Following treatment with propranolol, the mean percent inhibition caused by $100{\mu}l/ml$ Radix Asteris fell to 44.6% in guinea pig induced by histamine contraction and by $100{\mu}l/ml$ Radix Asteris fell to 18.7% (p<0.05) in rat induced by histamine contraction. Indomethacin and methylene blue$(10^{-7}M)$ did not significantly alter the inhibitory effect of Radix Asteris. These results indicate that Radix Asteris can relax histamine induced contraction of guinea pig and rat tracheal smooth muscle, and that this inhibition involves sympathetic effects.

  • PDF

Penetration and Microleakage Assessment of Flowable Resin Applied on Carious Fissure Following Various Fissurotomy Techniques (교합면 우식열구에서 열구성형술 방법에 따른 유동성 레진의 침투도와 미세누출 평가)

  • Kwon, Seok;Lee, Sangho;Lee, Nanyoung;Jih, Meongkwan;Yoon, Youngmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of fissurotomy on the penetration and microleakage of flowable resins for carious fissures. A total of 250 extracted premolars with early fissure caries were selected and divided into five groups according to the fissurotomy; no fissurotomy (n = 50), fissurotomy with $Fissurotomy^{(R)}$ original bur (n = 50), fissurotomy with $Fissurotomy^{(R)}$ Miro NTF bur (n = 50), fissurotomy with SF104R tapered diamond bur (n = 50), fissurotomy with 1/2 round carbide bur (n = 50). Two types of flowable resins ($UniFil^{(R)}Flow$, $Filtek^{(R)}Flow$) were used as sealing materials. All samples were sectioned and observed using a stereoscopic microscope after thermocycling and immersing in methylene blue solution. The adaptation of flowable resin to the fissure wall was observed using scanning electron microscopy. The penetration of flowable resin into the carious fissure was significantly increased by fissurotomy, which also decreased microleakage. Fissure preparation using different burs showed a significantly different in penetration, but did not show any difference in microleakage. $Unifil^{(R)}Flow$ showed better penetration than $Filtek^{(R)}Flow$, but there was no significant difference in microleakage. Fissurotomy can be used to increase the penetration of flowable resin into carious fissures and decrease microleakage.

Spectrophotometric Determination of Aminoglycoside Antibiotics Based on their Oxidation by Potassium Permanganate (과망간산포타슘에 의한 산화에 바탕을 둔 아미노글리코사이드 항생제의 분광광도법적 정량)

  • El-Didamony, A. M.;Ghoneim, A. K.;Amin, A. S.;Telebany, A. M.
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.4
    • /
    • pp.298-306
    • /
    • 2006
  • A rapid, simple and sensitive validated spectrophotometric methods have been described for the assay of neomycin and streptomycin either in pure form or in pharmaceutical formulations. The proposed methods were based on the oxidation of the studied drugs by a known excess of potassium permanganate in acidic medium and estimating the unreacted permanganate with amaranth dye (method A), acid orange II (method B), indigocarmine (method C), and methylene blue (method D), in the same acid medium at a suitable lmax=521, 485, 610 and 664 nm, respectively. Beers law is obeyed in the concentration range of 5-10 and 2-7 mg mL-1 for neomycin and streptomycin, respectively. The apparent molar absorptivity and sandell sensitivity values are in the range 5.47-6.20104, 2.35-2.91105 L mol-1 cm-1 and 7.57-8.59, 5.01-6.2 ng cm-2 for neomycin and streptomycin, respectively. Different variables affecting the reaction were studied and optimized. The proposed methods were applied successfully to the determination of the examined drugs either in a pure or pharmaceutical dosage forms with good accuracy and precision. No interferences were observed from excipients and the results obtained were in good agreement with those obtained using the official methods.

Microhardness and microleakage of composite resin according to the change of curing light intensity (다양한 중합광도에 따른 복합레진의 미세 경도와 변연 누출도)

  • Soo-man Park;Dong-Hoon Shin
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.363-371
    • /
    • 2001
  • 심미성 수복재 중합시 사용되는 광원은 다양한 요인들에 의해 선택되어지고 있지만 이러한 요인들은 앞으로도 논란의 여지를 많이 남겨두고 있다. 또한 현재 사용되고 있는 중합법들이 제각기 독특한 장점들을 갖고 있기 때문에 최적의 중합법 결정이 필요한 시점이다. 이에 본 연구에서는 중합광의 강도(50, 100, 200, 300, 400, 600mW/$\textrm{cm}^2$)와 중합시간(10, 20, 40초)을 다양하게 변화시켰을 때 복합레진의 미세경도와 미세누출도가 어떠한 양태를 보이는지를 관찰하고자 하였다. 본 실험에서는 A3 색상의 혼합형 복합레진인 국산 DenFil과 미세입자형 복합레진인 Esthet X를 사용하였다. 중합 1일 후 복합레진의 Vickers 경도는 다이아몬드형 압흔 길이를 측정하여 평가하였으며 미세누출도는 1% methylene blue용액을 이용한 방법과 주사전자 현미경을 이용한 수복물과 치질간의 최대 이개도 평가법의 두 가지 방법으로 측정하였다. 본 연구의 결과는 다음과 같다; 1. 미세경도는 시편 상면이 하면에 비해 단단한 양태를 보였으며 상, 하면에 관계없이 혼합형 복합레진인 국산 DenFil이 미세입자형 복합레진인 Esthetx에 비해 높은 경도치를 보였다. 2. 모든 미세 경도 실험에서 너무 낮은 광도(50mW/$\textrm{cm}^2$, 100mW/$\textrm{cm}^2$)로 중합한 군에서는 대조군에 비해 유의하게 낮은 미세 경도를 보였다(p<0.05). 3. 상면의 경우, DenFil은 중합시간과 관계없이 200mW/$\textrm{cm}^2$ 이상의 광도에서 대조군(600mW/$\textrm{cm}^2$ 광도로 40초간 중합)과 유의차 없는 미세경도치를 보였으나, Esthet X는 200mW/$\textrm{cm}^2$ 이상의 광도로 40초 동안 중합한 군에서만 대조군과 유의차 없는 미세경도치를 보였다. 4. 하면의 경우 DenFil은 300mW/$\textrm{cm}^2$ 이상의 광도로, Esthet X는 200mW/$\textrm{cm}^2$ 이상의 광도로 각기 40초 동안 중합한 군에서만 대조군과 유의차 없는 미세경도치를 보였다. 5. 법랑질 변연부에서는 색소 침투가 전혀 없었으나 상아질 변연부에서는 정도의 차이는 있었지만 모든 시편에서 색소 침투를 보였다. 6. 통계적 유의차는 없었지만 저광도에서 우수한 미세누출도를 보였으며 색소 침투법과 최대 이개도 평가법간에는 상관성이 매우 낮았다 (p=0.801).

  • PDF

THE EFFECT OF INTRACANAL BASE ON PREVENTION OF APICAL LEAKAGE OF BLEACHING AGENTS (무수치 표백술에서 근관내 Base가 표백약제의 누출 방지에 미치는 영향)

  • Choi, Seung-Ho;Ro, Byeng-Duck;Park, Sung-Ho;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.453-464
    • /
    • 1999
  • The non-vital bleaching technique has been used widely as a very effective treatment method on discolored non-vital teeth. But periodontal tissue deterioration and cervical external root resorption have been reported because of the high toxicity of hydrogen peroxide in bleaching agents. So in previous studies, placement of base over the root canal obturation prior to bleaching has been suggested in order to prevent microleakage of bleaching agents, however, the effectiveness of base is still controversial. The purpose of this study was to evaluate the effects of base and root canal sealer on prevention of leakage of bleaching agents in non-vital bleaching. Fifty-two extracted sound teeth with single root were used. For root canal obturation, Tubuli seal$^{(R)}$(Kerr Co., USA) was used in 39 teeth and in others, AH-26$^{(R)}$(De Trey Dentsply, Inc., Switzerland) was used as a root canal sealer. 26 teeth among the teeth obturated with Tubuli seal$^{(R)}$ were divided into two groups, and Dentin cement$^{(R)}$(GC corp., Japan) and JRM$^{(R)}$(De Trey Dentsply, Inc. Germany) were used in each group as a intracanal base. In all teeth, non-vital bleaching using bleaching agent mixed with methylene blue dye was performed and all specimens were stored in $37^{\circ}C$ water bath for 72 hours. After sectioning longitudinally, the depth of dye leakage was measured with digital vernier calipers under the stereobinocular microscope using ${\times}40$ magnification. It can be concluded as follows: 1. The microleakage of bleaching agent was observed ill all groups regardless of type of the base and the sealer. 2. The microleakage in the groups using AH-26$^{(R)}$ as a sealer was significantly reduced (p<0.05). 3. In the groups with intracanal base, micro leakage was observed through almost the whole depth of the base and there was no significant difference between Dentin cement$^{(R)}$ and IRM$^{(R)}$ group(p>0.05). In conclusion, all the basing materials and the sealers in this study did not prevent the microleakage of bleaching agent. Therefore further studies and attempts to seal off the pulp chamber will be necessary.

  • PDF

Properties of Low-Temperature Sol-Gel TiO2 Thin Films with Catalyst Content (졸-겔법으로 제작된 저온 TiO2 박막의 촉매농도에 따른 광분해 특성 분석)

  • Hong, Hyun-Joo;Heo, Min-Chan;Hahn, Sung-Hong;Kim, Eui-Jung;Lee, Chung-Woo;Joo, Jong-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.296-302
    • /
    • 2006
  • ILow-temperature $TiO_2$ sol was synthesized with various catalyst contents by using a sol-gel method. $TiO_2$ thin films were produced by a dip-coating method and their optical, structural and photocatalytic properties were examined. Transmittance of $TiO_2$ thin films with 0.10 mol, 0.25 mol, 0.50 mol and 0.75 mol catalyst content showed high transmittance in the visible range. XRD results showed the anatase-to-rutile phase transition was accelerated with increasing catalyst content and the crystallinity size of the $TiO_2$ thin films increased with increasing catalyst content. SEM results indicated that the particle size of the $TiO_2$ thin films was the smallest with catalyst content of 0.25 mol. Photocatalytic results showed that methylene blue was completely decomposed in the presence of anatase film prepared with 0.10 mol, 0.25 mol and 0.50 mol catalyst content.

The Experiences of the Emergency Antidote Stock and Delivery Service by the Korean Poison Information Center (독극물정보센터 구축사업의 일환으로 시행한 전국단위 응급해독제 비축 및 배송경험)

  • Park, So Young;Oh, Bum Jin;Sohn, Chang Hwan;Jeong, Ru Bi;Lim, Kyoung Soo;Kim, Won;Ryoo, Seung Mok
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.11 no.1
    • /
    • pp.9-18
    • /
    • 2013
  • Purpose: Antidotes for toxicological emergencies can be life-saving. However, there is no nationwide stocking and delivery system for emergency antidotes in Korea. We report on a two-year experience of a nationwide stocking and delivery trial for emergency antidotes at emergency departments in Korea. Methods: An expert panel of clinical toxicologists reviewed and made a list of 15 stocked antidote. These antidotes were purchased or imported from other countries and delivered from 14 antidote stocking hospitals nationwide 24 hours per day, seven days per week. Results: From August 1, 2011 to April 30, 2013, 177 patients with acute poisoning, with a median age of 48.5 years, were administered emergency antidotes. The causes of poisoning were intentional in 52.0% and 88.0% were intentional as a suicide attempt. Regarding clinical severity, using the poisoning severity score, 40.7% of patients had severe to fatal poisoning and 39.0% had moderate poisoning according to clinical severity. The most frequent presenting symptom was neurologic deficit, such as altered mentality (62.7%). alerted mentality (62.7%). Emergency antidotes were administered as follows: methylene blue (49 cases), flumazenil (31), N-acetylcysteine (25), glucagon (17), 100% ethanol (15), cyanide antidote kit (12), anti-venin immunoglobulin (5), pyridoxine (4), hydroxocobalamine (2), and deferoxamine (1). The median time interval from antidote request to delivery at the patient's bedside was 95 minutes (interquartile range 58.8-125.8). Conclusion: Findings of this study demonstrated the possibility of successful operation of the nationwide system of emergency antidotes stocking and delivery in Korea.

  • PDF

MICROLEAKAGE OF POSTERIOR PACKABLE COMPOSITE RESIN hi THE GINGIVAL MARGINS OF CLASS II CAVITIES (제 2급 와동에서 구치부 복합레진의 미세변연누출에 관한 연구)

  • Choi, Su-Jin;Kim, Mi-Ja;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.249-256
    • /
    • 2002
  • The use of flowable composite resins as liners in class II packable composite restoration has been suggested by some manufacturers. However, the contributions of this technique are unproven. The purpose of this study was to compare the gingival microleakage in class II packable composite restorations with or without the use of flowable composite resins as liners. Slot cavities were prepared on both proximals of 80 extracted human molars and randomly assigned to 8 groups of 20 each. The gingival margins were located at 1mm above CEJ in 80 cavities (group1-4) and 1mm below CEJ in 80 cavities (group5-8). The prepared teeth were mounted in the customized tray with adjacent teeth to simulate clinical conditions and metallic matrix band (Sectional matrix) and wooden wedges were applied. After acid etching and application of Single Bond, each group was restored with the following materials using incremental placement technique: Group 1,5 (Filtek P60), group 2, 3, 4 and group 6, 7, 8 (AeliteFlo, TetricFlow, Revolution/ Filtek P60). All specimens were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 1 mimute dwell time, immersed 2% methylene blue dye for 24 hours and then rinsed with tab water. The specimens were embedded in clear resin and sectioned longitudinally through the center of restoration with a low speed diamond saw. Dye penetration at gingival margin was viewed at 20 magnification and analyzed on a scale of 0 to 4. Kruscal-Wallis One way analysis and Mann-Whitney Rank sum test were used to analyze the results. The results of this study were as follows. 1. The leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. On the enamel margin, packable composite resins with flowable liners showed lower leakage than those without flowable liners, but there were no significant differences among the four groups(P>0.05). 3. On the dentin margin, four groups demonstrated moderate to severe leakage, and there were no significant differences in leakage values(P>0.05).

COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE (Continuous wave of obturation technique에서 플러거의 다양한 적용 깊이에 따른 근단부 폐쇄효율 비교)

  • Lee, Sang-Jin;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.491-497
    • /
    • 2007
  • The purpose of this study was to compare apical sealing ability of continuous wave canal filling technique according to various heat source plugging depths. Eighty one extracted human premolars with straight root were cleaned and shaped to size 35 using .06 taper rotary NiTi file. After cleansing and shaping, the teeth were divided into 5 groups following the heat source probing depths from the apex; 3, 4, 5, 6 and 7 mm. All specimens were filled using E&Q plus with #35/.06 tapered gutta-percha cone. The positive control teeth were not filled. All teeth were coated with nail varnish except the apical 1 mm around the apical foramen. Negative control teeth were completely sealed include the apical foramen. All specimens were immersed in 1% methylene blue solution for 72 hours. Then the specimens were sectioned horizontally at 1, 2 and 3 mm from the root apex. Each sectioned surface was photographed using a digital camera attached to the stereomicroscope at $12.5{\times}2.5$ fold magnification. All points at 1, 2 and 3 mm were summed as final score of one specimen. Statistical analysis of the collected data was performed. Under the condition of this study. there was no significant difference between the heat source plugging depths of 3, 4, 5, 6 and 7 mm in apical sealing ability. All of apical heat source plugging depth from 3 to 7 mm including Buchanan's protocol -from 5 to 7 mm- seems to be acceptable in clinical application.