• 제목/요약/키워드: method of lines

검색결과 3,180건 처리시간 0.032초

특별고압 전선로에 대한 인체접근한계의 이론적연구 (A Study on the Theoretical Analysis of Human Body Approximation to Special High Voltage Eletric Lines)

  • 김상렬;김찬오;이재인
    • 한국안전학회지
    • /
    • 제5권3호
    • /
    • pp.44-50
    • /
    • 1990
  • This study is conducted to examine the theoretical background of characteristics for electric shock encountered in special high-voltage electric lines among the accidents of electric shock, and to calculate applied current to human body and field strength over the head by means of numerical anaysis through FEM(Finite Element Method), and to make clear the hazard level to the human body, and to establish the approach limit distance of human body to the electric lines, which could be applied to the safety standard while working in the vicinity of special high-voltage electric lines.

  • PDF

인삼 육성계통의 Fusarium sozani에 의한 근부병 저항성 비교 (Comparison of Resistance of Root Rot Caused by Fusarium solani in Ginseng Breeding Lines)

  • 천성룡;김홍진
    • Journal of Ginseng Research
    • /
    • 제14권1호
    • /
    • pp.50-56
    • /
    • 1990
  • Root-rot of ginseng caused by Fusarium solani is one of the most obstacles to ginseng cultivation. We evaluated some inoculating techniques of ginseng with Fusarium solani, for selection of disease resistant breeding lines. The most effective inoculating techniques evaluated were inserting toothpicks colonized by F. solani into the seedling roots in laboratory test and dusting seedlings with vermiculite after dipping in conidial sllspension and then replanting method in field test. The resistance to diseased by F. solani was lines of 82022 and 82066 in laboratory test. 82920-1 and 78093 in field test.

  • PDF

Partial Diallel Crosses Using Group Divisible Designs

  • Jong SeongGong Sun;Kim, Gong-Sun
    • Communications for Statistical Applications and Methods
    • /
    • 제8권2호
    • /
    • pp.367-374
    • /
    • 2001
  • In this paper, a method based on group divisible designs is presented for constructing some partial diallel crosses. We discuss in detail a particular inbred line, i.e., p lines divided into two groups with p$_1$ lines and p$_2$ lines. These designs are obtained by regarding the number of lines as treatments. In specially we study and compare the efficiency factors of the constructed partial diallel crosses with or without repeated blocks.

  • PDF

경계요소법을 이용한 압축성형다이 가열선의 최적위치 설계 (Optimal Positioning of Heating Lines in a Compression Molding Die Using the Boundary Element Method)

  • 이부윤;조종래
    • 대한기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.1478-1485
    • /
    • 1993
  • 본 연구에서는 압축 성형다이 가열선의 최적위치를 결정하는 문제를 다이의 형상 최적설계 문제로 정식화하고자 한다. 최적화 문제의 목적은 다이 내면의 온도를 지정된 온도로 균일하게 유지하는 것이다. 또한 Lee, Choi와 Kwak의 형상 설계 민감 도 해석을 위한 직접 미분 방법을 응용하여 가열선 위치변화에 관한 민감도 계산을 위한 경계 적분 방정식을 유도하고, 경계요소법으로 온도와 온도의 민감도를 해석하고 자 한다. 수치적 응용의 예로서, 넓은 평판의 성형을 위한 압축 성형다이의 가열선의 최적위치를 결정하는 문제를 다루고, 최적위치에서 가열선의 개수가 온도의 균일성에 미치는 영향을 검토한다.

신경회로망을 이용한 송전선 허용용량 예측기법 (Dynamic Line Rating Prediction in Overhead Transmission Lines Using Artificial Neural Network)

  • 노신의;김이관;임성훈;김일동
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.79-87
    • /
    • 2014
  • With the increase of demand for electricity power, new construction and expansion of transmission lines for transport have been required. However, it has been difficult to be realized by such opposition from environmental groups and residents. Therefore, the development of techniques for effective use of existing transmission lines is more needed. In this paper, the major variables to affect the allowable transmission capacity in an overhead transmission lines were selected and the dynamic line rating (DLR) method using artificial neural networks reflecting unique environment-heat properties was proposed. To prove the proposed method, the analyzed results using the artificial neural network were compared with the ones obtained from the existing method. The analyzed results using the proposed method showed an error of 0.9% within ${\pm}$, which was to be practicable.

Novel Calibration Method for the Multi-Camera Measurement System

  • Wang, Xinlei
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.746-752
    • /
    • 2014
  • In a multi-camera measurement system, the determination of the external parameters is one of the vital tasks, referred to as the calibration of the system. In this paper, a new geometrical calibration method, which is based on the theory of the vanishing line, is proposed. Using a planar target with three equally spaced parallel lines, the normal vector of the target plane can be confirmed easily in every camera coordinate system of the measurement system. By moving the target into more than two different positions, the rotation matrix can be determined from related theory, i.e., the expression of the same vector in different coordinate systems. Moreover, the translation matrix can be derived from the known distance between the adjacent parallel lines. In this paper, the main factors effecting the calibration are analyzed. Simulations show that the proposed method achieves robustness and accuracy. Experimental results show that the calibration can reach 1.25 mm with the range about 0.5m. Furthermore, this calibration method also can be used for auto-calibration of the multi-camera mefasurement system as the feature of parallels exists widely.

Open-Short 방식의 임피던스 측정에 의한 분포정수의 보정 (A LOSSY LINE DISTRIBUTED PARAMETERS CALCULATION USING DATA OF OPEN-SHORT IMPEDANCE MEASURING METHOD)

  • ;조기연;변영복;서정일;김은수;김태진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2553-2555
    • /
    • 1999
  • The paper contains design formulas and an execution algorithm for calculation of distributed parameters as well as wave and impedance parameters of a uniform transmission line using data of the line input impedance measurements by the OPEN-SHORT method. In difference from published before works on the OPEN-SHORT method application for line parameters determination, in which the lines with small losses are considered /1-3/, the obtained formulas allow to calculate parameters of transmission lines with arbitrary losses. It opens new possibilities of the OPEN-SHORT method utilization for development and application of the probe - type lossy dielectric media parameters meters based on transmission lines, including probe-type moisture material meters.

  • PDF

신드롬 테스트가 용이한 대규모 MOSPLA의 설계 (Syndrome Testable Design for Large MOSPLA's)

  • ;임인칠
    • 대한전자공학회논문지
    • /
    • 제24권3호
    • /
    • pp.527-534
    • /
    • 1987
  • This paper proposes a new syndrome-testable design method for large MOSPLA's. In the conventional syndrome test method, the testing array circuit for testability is added but it has the defect that the circuit gives effect on the normal operation of the basic PLA circuit. Therefore, by adding the shift registers to the product lines of the basic MOSPLA's this defect is eliminated and the number of test patterns is decreased. In order to reduce the number of fault free syndromes to be predetermined, also, one output line, which is connected to all product lines is added. Therefore the number of output lines be observed is decreased. And the analytical method to compute fault free syndromes is presented. By unsing this method, the time and the effort to compute the syndromes are decreased.

  • PDF

전송선의 전하 분포 및 등전위선 산출 (Charge Distributions and Equipotential lines in Multiconductor Transmission lines)

  • 정백호;박경희;김채영;송재원;김수중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.450-453
    • /
    • 1988
  • A numerical scheme is considered for computing charge distributions and drawing equipotential lines for multiconductor transmission lines with arbitrary cross sections. Two-dimensional integral equation superposed by the charges is numerically calculated by the method of moments. Here in Galerkin's method special pulses cut into halves chosen for expansion and testing functions facilitate the numerical computations in solving the integral equation. Numerical examples are given for some system of which the shell conductor is grounded as the reference zero of potential.

  • PDF

Higher Order Wall Boundary Conditions for Incompressible Flow Simulations

  • Nishida Hidetoshi
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.61-62
    • /
    • 2003
  • In this paper, the new higher order wall boundary conditions are proposed for solving the incompressible flows. The square driven cavity flows are simulated by using the variable order method of lines with the present wall boundary conditions. The variable order method of lines is constructed by the spatial discretization, i.e., the variable order proper convective scheme for convective terms and the modified differential quadrature method for diffusive terms, and time integration. The 2nd, 4th, and 6th order solutions are presented and these results show this higher order boundary conditions are very promising for the incompressible flow simulations.

  • PDF