A Study on the Compensation Method in the Measuring System for Chopped Lightning Impulse (충격전압 재단과 측정을 위한 보상회로에 관한 연구)

  • Kim, Ik-Soo;Kim, Young-Bae;Kim, Jin-Gi;Kim, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1895-1897
    • /
    • 1996
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard (IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Comparison tests of dividers for chopped lightning impulse measurement were rallied out by KERI. The 700kV shielded resisitive divider with and without compensation element were done comparison test with 300kV PTB divider which have the similar charateristics as that were circulated among the laboratories. This paper reports on the calculation results of response charateristics obtained by EMTP and the comparison test results with chopped lightning impulse voltages from 150kV to 250kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

A study on the comparative method of prescription using gunsinjwasa theory (군신좌사 개념을 도입한 방제 검색 및 비교 시스템에 관한 연구)

  • Park, Hansu;Lee, ByungWook;Lee, Boo-Kyun
    • Herbal Formula Science
    • /
    • v.22 no.2
    • /
    • pp.45-54
    • /
    • 2014
  • Objectives : The main objective of this study is to classify herbal components to 4 groups which are similar to Gunsinjwasa grades by using herbal composition ratio of prescription. Another objective is to design the searching system which compares prescriptions and improves efficiency with 4 groups like Gunsinjwasa grades. Methods : This study was proceeded with Acess 2007 on Microsoft Windows 7 and we created composition ratio based on weight by using prescriptions of Donguibogam, Uihagipmun and Banghakhabpyun. We could make comparison and searching method of prescriptions. Results : We could search using composition ratio degree of herbs which composes prescription. And the similarity comparison of prescription was possible with value from 0 to 10. Conclusions : We could increase the accuracy of the searching prescriptions and comparison with putting into the information about composition degree and composition ratio of herbs which compose a prescription.

Comparison of Current Control Method for Single-phase PFC converter with 1-switch Voltage Doubler Strategy (단일 스위치 배전압 방식의 단상 PFC 컨버터의 전류 제어기법 비교)

  • Ku, Dae-Kwan;Ji, Jun-Keun;Cha, Guee-Soo;Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • This paper describes the performance comparison results for current controller of a single-phase PFC converter with 1-switch voltage doubler strategy for single-phase double-conversion UPS(Uninterruptible Power Supply). A single-phase PFC converter with 1-switch voltage doubler strategy needs a diode bridge and one bidirectional active switch. Thus it is possible to reduce the material cost. However, the study results of current controller design and comparison of current control method has not been known after the converter circuit was proposed. For the performance comparison of current control, single-phase 3 kVA double-conversion UPS was tested. The performance of PI and PR current controller is experimentally confirmed with followings - input current reference tracking, input power factor correction and input current THD suppression.

A comparison of three performance-based seismic design methods for plane steel braced frames

  • Kalapodis, Nicos A.;Papagiannopoulos, George A.;Beskos, Dimitri E.
    • Earthquakes and Structures
    • /
    • v.18 no.1
    • /
    • pp.27-44
    • /
    • 2020
  • This work presents a comparison of three performance-based seismic design methods (PBSD) as applied to plane steel frames having eccentric braces (EBFs) and buckling restrained braces (BRBFs). The first method uses equivalent modal damping ratios (ξk), referring to an equivalent multi-degree-of-freedom (MDOF) linear system, which retains the mass, the elastic stiffness and responds in the same way as the original non-linear MDOF system. The second method employs modal strength reduction factors (${\bar{q}}_k$) resulting from the corresponding modal damping ratios. Contrary to the behavior factors of code based design methods, both ξk and ${\bar{q}}_k$ account for the first few modes of significance and incorporate target deformation metrics like inter-storey drift ratio (IDR) and local ductility as well as structural characteristics like structural natural period, and soil types. Explicit empirical expressions of ξk and ${\bar{q}}_k$, recently presented by the present authors elsewhere, are also provided here for reasons of completeness and easy reference. The third method, developed here by the authors, is based on a hybrid force/displacement (HFD) seismic design scheme, since it combines the force-base design (FBD) method with the displacement-based design (DBD) method. According to this method, seismic design is accomplished by using a behavior factor (qh), empirically expressed in terms of the global ductility of the frame, which takes into account both non-structural and structural deformation metrics. These expressions for qh are obtained through extensive parametric studies involving non-linear dynamic analysis (NLDA) of 98 frames, subjected to 100 far-fault ground motions that correspond to four soil types of Eurocode 8. Furthermore, these factors can be used in conjunction with an elastic acceleration design spectrum for seismic design purposes. Finally, a comparison among the above three seismic design methods and the Eurocode 8 method is conducted with the aid of non-linear dynamic analyses via representative numerical examples, involving plane steel EBFs and BRBFs.

Comparison of acridine orange and giemsa stains for malaria diagnosis (말라리아 진단을 위한 Acridine Orange 염색법과 Giemsa 염색법의 효율성 비교)

  • 공현희;정동일
    • Parasites, Hosts and Diseases
    • /
    • v.33 no.4
    • /
    • pp.391-394
    • /
    • 1995
  • Recently, the Acridine orange (AO) staining method has improved for identification of malaria parasites. Fixed and preserved blood smears of malaria patients were used for comparative analysis of AO and Giemsa stains. The AO staining method required less time and was more sensitive under lower magnification than the Giemsa staining method . The AO staining method provides an alternative to Giemsa for malaria diagnosis in the field and laboratory.

  • PDF

Automated Layout of PLA using CIF (GIF를 이용한 PLA의 Layout 자동화)

  • Jeong, Seung-Jeong;Yang, Yeong-Il;Gyeong, Jong-Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.1
    • /
    • pp.14-21
    • /
    • 1985
  • In this paper, a new pitch extraction method, the area comparison method, is proposed. By the speech production model, the area of the first peak on a pitch interval of speech signals is emphasized. By using the above characteristics, this method have more advantages than the others for pitch extraction. The defective decision caused by an impulsive noise is minimized and the pre-filtering is not necessary for this rr ethos, because the integration of signals takes place in the process.

  • PDF

EVALUATION OF PARAMETER ESTIMATION METHODS FOR NONLINEAR TIME SERIES REGRESSION MODELS

  • Kim, Tae-Soo;Ahn, Jung-Ho
    • Journal of applied mathematics & informatics
    • /
    • v.27 no.1_2
    • /
    • pp.315-326
    • /
    • 2009
  • The unknown parameters in regression models are usually estimated by using various existing methods. There are several existing methods, such as the least squares method, which is the most common one, the least absolute deviation method, the regression quantile method, and the asymmetric least squares method. For the nonlinear time series regression models, which do not satisfy the general conditions, we will compare them in two ways: 1) a theoretical comparison in the asymptotic sense and 2) an empirical comparison using Monte Carlo simulation for a small sample size.

  • PDF

Performance Comparison of Semi-active Control Algorithms for a Large-scale MR Damper using Real-time Hybrid Test Method (실시간 하이브리드 실험법을 이용한 대형 MR감쇠기의 준능동 제어알고리즘 성능 비교)

  • Park, Eun-Churn;Lee, Sung-Kyung;Lee, Heon-Jae;Choi, Kang-Min;Moon, Suk-Jun;Jung, Hyung-Jo;Chung, Hee-San;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.648-654
    • /
    • 2007
  • This paper presents the result of a comparison study to evaluate the performance of several semi-active control algorithms for use with large-scale MR damper applied to a building structure under seismic excitation using real-time hybrid test method. Recently, a variety of semi-active control algorithm studies are developed and generally evaluated the performance by using numerical analysis. In this paper real-time hybrid test method was applied to performance evaluating of semi-active control algorithms including a clipped optimal algorithm and the modulated homogeneous friction algorithm.

  • PDF

COMPARISON OF SIGNAL PROCESSING TECHNIQUES FOR UT-NDE ON NUCLEAR POWER PLANTS

  • Lee, Young-Seock;Kim, Se-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.359-364
    • /
    • 2004
  • This paper deals with the comparison of signal processing techniques of ultrasonic data. The goal of signal processing is the ultrasonic speckle suppression and the visibility enhancement of flaw-reflected ultrasonic echo. The performance of conventional SSP(split spectrum processing) method and the wavelet denoising method are compared and discussed for tested ultrasonic data. Tested ultrasonic data obtained from the weld area of centrifugal-casted stainless steel material and safe-ending material with holes and notch of variable depths are presented. In experimental results, the outputs of wavelet-based denoising method show the clear and sharp peaks at the positions of flaw-reflected echos comparing with those of SSP method.

  • PDF

Risk Analysis Method Applied to Train Control Systems for Safety Assurance (열차제어시스템 안전성 확보를 위한 위험도 분석 방법 적용)

  • Jo, Hyun-Jeong;Hwang, Jong-Gyu
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.5
    • /
    • pp.71-76
    • /
    • 2007
  • Failures of equipments for train control systems are linked directly to extensive damages of human lives or financial losses from the increasing uses of train control equipments utilizing computers. Then safety activities for assuring safety and reliability are needed during the system life-cycle. Risk analysis is important phase to increase safety from determining the risk presented by the identified hazard. In this paper, we investigated several methods for risk estimation of safety activities, and then we drew a comparison between original methods to suggest optimized one in the application to train control systems. In the result of the comparison, we had plan to propose the risk analysis method called Best-Practice(BP) risk method combining advantages of the qualitative and the quantitative analysis. In addition, we attempted to apply the BP-risk method to domestic train control systems handling in Korea.