Development of Water Meters for Frozen Inflation Pressure Absorption Based on Structural Analysis (구조해석 기반 동결팽창압 흡수용 수도미터 개발)

  • Kim, Kuk-il;An, Sang-byung;Lee, Byung-sun;Hong, Sung-taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.314-316
    • /
    • 2022
  • Instrumentation device to the amount of water used by the user is a water meter by measuring management stability is necessary. But with the onset of winter to meter water was ice inside the phase change and about 9 % and increase the volume of the meter is damaged. The existing protection bleed water meter freeze protection technology into three great bootong, supplying the heat insulation inside the external protection, water metering for water meter in the freeze protection will be divided into installing the device. Not see how far the structure for the commercialization of new technology-based products and aims to develop technologies that do not require an external power supply. Thus, freeze more vulnerable by internal pressure of the interpretation applied to a water meter in temperatures below zero internal pressure to confirm the area of preventing damage and freeze protection that can reduce the effect is superior to develop a water meter.

  • PDF

Fabrication of Level Meter for Liquid Nitrogen (액체 질소 액면계의 제작)

  • 김상보;김근홍;김종윤;이정민;김동락
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.182-184
    • /
    • 1999
  • Very simple continuous level meter with capacitive transducer for cryogenic liquid is fabricated and tested with liquid nitrogen. The principle of the level meter operation is presented.

  • PDF

Effects of Nozzle Diameter on Performance Characteristics for a Tangential Impeller-type Water Meter (접선류 임펠러형 수도미터의 노즐직경이 성능특성에 미치는 영향)

  • Suh, Sang-Ho;Lee, Byung-Ho;Cho, Min-Tae;Roh, Hyung-Woon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.59-66
    • /
    • 1999
  • In this study the effects of nozzle diameter on the performance characteristics for the tangential impeller-type water meter are studied experimentally. The nozzle is cut along the tangential direction of the inner case in the water meter. The nozzle shape is round and the number of nozzles used for the experimental study are 8. The performance characteristics are discussed for various nozzle diameters such as 3.1, 3.3, 3.5, 4.0, 4.5 and 5.0 mm. Among the tangential impeller-type water meters, the water meter with the nozzle diameter of 5.0 mm shows the least pressure loss and the instrumental error compared to the Korean Standards.

  • PDF

Air Flow Rate Measurement in Multi Point Injection Engine U sing Ultrasonic Sensors (초음파센서를 이용한 전자식 연료분사엔진의 흡기유량측정)

  • Park, K.S.;Kim, J.I.;Kauh, S.K.;Noh, S.T.;Lee, J.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.3
    • /
    • pp.58-65
    • /
    • 1995
  • In this study an air flow meter was developed for MPI engine using ultrasonic sensors. The major characteristcs of the ultrasonic flow meter are high speed response, flow direction recognition and linear output. The air flow rate measurements were conducted at upstream of the throttle and intake manifold. The characteristics of the ultrasonic flow meter are compared with those of the Bosch hot wire flow meter at both steady and unsteady engine conditions.

  • PDF

A Study for the Improvement of Performance of the Water-meter applying the Hydrodynamic Journal Bearing Theory (동압 유체 베어링 이론을 적용한 수도미터의 성능향상에 관한 연구)

  • Yoon, Joon-Yong;Sung, Nak-Won;Kim, Byung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.1 s.6
    • /
    • pp.5-9
    • /
    • 2000
  • A study to minimize the error in water-meter is considered in this work. It is presumed that the large amount of error at large flowrate is occurred due to the vibration of the impeller shalt. After a newly designed bushing applying hydrodynamic journal bearing theory is adopted, the error at large flow rate is decreased remarkably comparing with the classical water-meter. It is concluded that the effect of a bushing in water-meter stabilizes the rotator of the impeller shaft.

  • PDF

Development of cryogenic liquid-vapor separator and liquid-level meter operating under high pressure condition (고압 상황에서 작동되는 극저온 기액 분리기와 액체 계면 측정기의 개발)

  • Lee, Cheon-Kyu;Hwang, Gyu-Wan;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.51-55
    • /
    • 2011
  • In this study, the liquid-vapor (L-V) separator equipped with liquid-level meter is developed. In the developed L-V separator, the flange is designed to be attachable so that the separator can be flexibly applied under any cases where the volumetric of L-V separator is varied by the system requirement. The leak-tightness between the attachable flange and the chamber is experimentally confirmed with the use of double groove indium wire sealing even under the high pressure up to 20 bar. In addition, the liquid-level meter is designed and fabricated to figure out the inner state of L-V separator. It consists with 19 carbon composition resistors in series. All resistors are separately calibrated in the temperature range from 77 K to 200 K. The performance of the L-V separator and the liquid-level meter is investigated with experimental tests, and the result is presented in this paper.

Experimental Study of Cushioning Pneumatic Cylinder with Meter In/Meter Out Control System (메타인 및 메타아웃 제어에 의한 공기압 실린더의 쿠션특성에 관한 실험적 연구)

  • 김동수;이상천
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.2
    • /
    • pp.97-104
    • /
    • 2000
  • Pneumatic cylinder is widely used for mechanical handling systems. Often, the impact occurs at the both ends points of pneumatic cylinder and generates destructive shock with in the structural operating members of the machine or equipment. To reduce the damage of system, therefore, shock absorbing devices are required. Cushioning of pneumatic cylinders at one or both ends of piston stroke is used to reduce the shock and vibration. The cylinder body have to withstand under high velocity and load. In this research, the pneumatic cushioning cylinder moving tests have been conducted for different load mass and supply pressure. The velocity of pneumatic cylinder actuation system with multiple orifice cushion sleeve which is set vertically controled with meter-in/out system. This study examines the dynamic characteristics of pneumatic cylinder with cushion devices. It turns out that the cushion pressure is mainly a function of the external load rather than the supply pressure. The cushion region characteristics was also revealed in the meter-in system.

  • PDF

Structural Analysis of Hydraulic Valve Meter (밸브 수압측정기의 구조해석)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1447-1452
    • /
    • 2012
  • Existing hydraulic valve meter used in industrial fields precise pressure measurement gives inconvenience in precise measurement due to manually regulated pressures. In order to improve this inconvenience, the hydraulic valve meter was designed by using automatic design program CATIA and structural analysis of the designed hydraulic valve meter was conducted and internal water leaking, stress, strain and total deformation were obtained by applying three dimensional finite element code ANSYS. These results will be provided to develop new concepts of hydraulic valve meters as fundamental data.

Implementation of S1n91e-Phase SAMRT Meter using Programmable IC (Programmable IC를 이용한 다기능 전자식 단상 전력량계 기능 구현)

  • Park, Jong-Beom;Yoon, Gi-Gab;Woo, Sang-Mok;Park, In-Kwon;Kim, Hong;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.644-646
    • /
    • 2000
  • According to the deregulations of governments in the world. the power industries of United State and European nations are proceeding remote meter reading and remote load control. But the core technology of multifunctional electronic meter implemented by programmable one-chip IC, which can be the right answer of all the power industy's efforts is now still under development in the advanced countries. Implementation of smallest size, lowest price single-phase meter with features which enable distribution automation such as bidirectional communication, Remote load control, remote meter reading, remote credit assigment. Prepayment billing system.

  • PDF

A Study on the Design of Advanced Digital Kwh-Meter for the Remote Management of Distribution System (배전원격관리를 위한 차세대 디지털 적산전력계 설계)

  • Ko, Yun-Seok;Lim, Chul-Sy;Lee, Kwan-Ho;Yun, Sang-Moon;Seo, Seong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.238-240
    • /
    • 2002
  • This paper proposes an advanced digital kwh-meter, which records voltage management data, load management data as well as the existing kwh data. This meter supports the requests from DRMS (Distribution Remote Management System) which include kwh meter reading, voltage management data reading, and load management data reading request, it can enhance greatly the economics of the existing remote meter reading system. Also it can improve highly the quality of power supplied to the electric customer by minimizing the voltage management cost and by enhancing the efficiency of load management.

  • PDF