• 제목/요약/키워드: metallic ion

검색결과 225건 처리시간 0.022초

In-line Monitoring of an Oxide Ion in LiCI Molten Salt Using a YSZ Based Oxide Ion Selective Electrode

  • Cho, Young-Hwan;Jeon, Jong-Seon;Yeon, Jei-Won;Choi, In-Kyu;Kim, Won-Ho
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.415-419
    • /
    • 2004
  • The electrode potential characteristics of a YSZ based membrane metal oxide electrode have been studied in molten LiCL at $700^{\circ}C$ by the potentiometric method. The electrode exhibited a good potential response to log[$O^2$] and data reproducibility. The calibration plot (potential vs. log[$O^2$] was found to be linear, obeying the Nernst equation. The electrode potential showed a good reversibility corresponding to increase/decrease of the oxide ion present in the molten LiCl. The physical and chemical durability appeared to be sound after several repeated uses, resulting in reproducible results. However, "the proposed electrode" failed when metallic Li was present in the melt.

고 에너지 (1.5 MeV) Boron 이온 주입과 초기 산소농도 조건이 깊은 준위에 미치는 영향에 관한 연구 (The Effects of high Energy(1.5MeV) B+ ion Implantation and Initial Oxygen Concentration Upon Deep Level in CZ Silicon Wafer)

  • 송영민;문영희;김종오
    • 한국재료학회지
    • /
    • 제11권1호
    • /
    • pp.55-60
    • /
    • 2001
  • 고 에너지 (1.5 MeV) 이온 주입된 Boron의 농도와 silicon 기판의 초기 산소 농도의 변화에 따라 silicon기판에 형성된 결정 결함 및 금속 불순물의 Gettering 효율에 대하여 DLTS(Deep Level Transient Spectroscopy), SIMS(Secondary ion Mass Spectroscopy), BMD(Bulk Micro-Defect) analysis 및 TEM (Transmission Electron Microscopy)을 이용하여 연구하였다. 이온 주입 전후의 DLTS 결과를 확산로 및 RTA를 이용한 열처리 전후의 DLTS 결과와 비교할 때 이온 주입 전 시편에서 볼 수 있는 공공에 의한 깊은 준위는 열처리 온도의 증가에 따라 금속 불순물과 관련된 깊은 준위로 천이함을 알 수 있다. 또한 고온 열처리의 경우, 초기 산소 농도가 높을수록 깊은 준위의 농도가 감소함을 볼 때 초기 산소 농도가 높을 수록 gettering 효율 측면에서 유리한 것으로 사료된다

  • PDF

황산과 염산 합성용액에서 이온교환에 의한 니켈(II), 코발트(II), 망간(II) 및 실리케이트(IV)의 분리 (Separation of Ni(II), Co(II), Mn(II), and Si(IV) from Synthetic Sulfate and Chloride Solutions by Ion Exchange)

  • ;;이만승
    • 자원리싸이클링
    • /
    • 제31권3호
    • /
    • pp.73-80
    • /
    • 2022
  • 폐리튬이온전지를 고온에서 용융환원하면 금속혼합물을 얻을 수 있다. 금속혼합물을 황산이나 염산으로 침출한 다음 용매추출로 분리한 여액에는 니켈(II), 코발트(II), 망간(II)과 실리케이트(IV)가 함유되어 있다. 본 논문에서는 양이온교환수지인 Diphonix와 P204를 사용하여 황산과 염산 합성용액에 함유된 상기 이온들의 이온교환거동을 조사했다. 용액의 pH가 3인 황산용액에서 니켈(II), 코발트(II)와 망간(II)이 선택적으로 Diphonix에 흡착되었다. 용액의 pH가 6인 염산용액에서는 망간(II)이 P204수지에 선택적으로 흡착되어 분리가 가능했다. Diphonix와 P204에 흡착된 금속이온은 황산이나 염산용액으로 세출할 수 있었다.

금속 마이그레이션에 의한 화재 위험성 연구 (A Study on Fire Hazard by Metallic Migration)

  • 최경원;현병수;김선재;임규영;우승우;이동규;조영진;박종택;고재모;박남규
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.114-119
    • /
    • 2019
  • 우리는 LED등기구의 Printed circuit board (PCB)에서 화재의 원인으로 특정할 수 있는 금속 마이그레이션(Metallic migration) 현상을 발견하고, 본 연구를 진행하였다. 금속 마이그레이션 현상 가속화 실험인 물방울 시험을 소량의 물과 저전압(3 V)로 진행하고 절연되어있는 양극에서 직접적으로 금속 마이그레이션의 성장과 회로의 단락을 확인하였다. 그리고 전자주사현미경(SEM)을 통해 형태를 관찰하고 에너지 분산형 분광기(EDS)를 이용하여 성분을 분석한 결과, 절연된 부분에서 전극을 이루고 있는 구리의 성분을 검출하였다.

발전소용 이중보온용 강관의 홈부식(Grooving Corrosion)에 의한 파손 분석 (The Failure Analysis of Double Pipe for Insulation Used Power Plant by Grooving Corrosion)

  • 함종오;박기덕;박성진;선일식
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권3호
    • /
    • pp.197-206
    • /
    • 2015
  • Failure analysis of pre-insulated pipe (SPPS 380, 400A) transporting high temperature water ($95{\sim}110^{\circ}C$) for a plant was carried out. The damaged area (${\Phi}5mm$) of pre-insulated pipe was found only on welds. The chemical composition of damaged pipe meets specification of carbon steel pipes for pressure service (KS D 3562). As results of microstructure analysis, crack propagated from outer to inside after pitting corrosion occurred on the outside surface. The non-metallic inclusion existed on the end of crack. And the non-metallic inclusion continuously and linearly formed along with the bond line of welds. Based on SEM-EDS analysis, the nonmetallic inclusions have higher Manganese (Mn) and Oxygen (O) content but sulfur (S) was not detected. As results of water quality analysis, hydrogen ion concentration and minerals like Fe, Mg, Si were in low level. But the content of dissolved oxygen (11.2 ppm) was slightly higher than that of standard. It seems that the cause of damaged pipe is grooving corrosion due to MnO inclusion formed on bond line and corrosion took place nearby welds.

Removal of Metallic Cobalt Layers by Reactive Cold Plasma

  • Kim, Yong-Soo;Jeon, Sang-Hwan;Yim, Byung-Joo;Lee, Hyo-Cheol;Jung, Jong-Heon;Kim, Kye-Nam
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.32-42
    • /
    • 2004
  • Recently, plasma surface-cleaning or surface-etching techniques have been focused in respect of the decontamination of spent or used nuclear parts and equipment. In this study the removal rate of metallic cobalt surface is experimentally investigated via its surface etching rate with a $CF_4-o_2$mixed gas plasma. Experimental results reveal that a mixed etchant gas with about 80% $CF_4$-20% $O_2$ (molar) gives the highest reaction rate and the rate reaches 0.06 ${\mu}m$/min at $380^{\circ}C$ and ion-assisted etching dramatically enhances the surface reaction rate. With a negative 300 V DC bias voltage applied to the substrate, the surface reaction initiation temperature lowers and the rate increases about 20 times at $350^{\circ}C$ and up to 0.43 ${\mu}m$/min at $380^{\circ}C$, respectively. Surface morphology analysis confirms the etching rate measurements. Auger spectrum analysis clearly shows the adsorption of fluorine atoms on the reacted surface. From the current experimental findings and the results discussed in previous studies, mechanistic understanding of the surface reaction, fluorination and/or fluoro-carbonylation reaction, is provided.

  • PDF

Layered Nickel-Based Oxides on Partially Oxidized Metallic Copper Foils for Lithium Ion Batteries

  • Chung, Young-Hoon;Park, Sun-Ha;Kim, Hyun-Sik;Sung, Yung-Eun
    • Journal of Electrochemical Science and Technology
    • /
    • 제2권4호
    • /
    • pp.204-210
    • /
    • 2011
  • Thin film electrodes have been intensively studied for active materials and current collectors to enhance the electrochemical performance. Here, porous structures of nickel-based oxide films, consisting of nickel oxide and copper (II) oxide, which was derived from the copper substrate during the annealing process, were deposited on metallic copper foils. The half-cell tests revealed excellent capacity retention after $80^{th}$ charge/discharge cycles. Some films showed an excess of the theoretical capacity of nickel oxides, which mainly originate from partially oxidized copper substrates during annealing. These results exhibit that both a preparation method of an active materials and partially oxidized current collectors could be important roles to apply thin film electrodes.

우릉쉥이(Cynthia roretzi v. Drasche)의 소화효소에 대하여 (제2보) Proteinase의 효소적 성질 (Studies on the Digestive Enzyme of Cynthia roretzi V. Drasche. II. Some propeinic properties of Amylase.)

  • 서석수;양한석
    • 약학회지
    • /
    • 제5권1호
    • /
    • pp.51-55
    • /
    • 1960
  • Some enzymatic properties of Cynthia roretzi V. Drasche (Korean:U-Rung-Shei) was studied by author and obtained the following results; 1. The optimum pH of the digestive gland proteinase ws 7.4-7.6 2. Activity of metallic ion on the Proteinase showed following order; 10$^{-3}$ M. M $n^{++}$>1-$^{-3}$ M. $Co^{++}$>10$^{-4}$ M. $Mg^{++}$\ulcorner10$^{-2}$ M.S $r^{++}$. Inhibition of metallic ion on the Proteinase showed following order: 10$^{-3}$ M. A $g^{+}$>10$^{-3}$ M. c $d^{++}$>10$^{-3}$ M. P $b^{++}$>10$^{-3}$ M. Z $n^{++}$ 3. The digestive gland enzyme inactivated at 70.deg. C, but no influence at 50.deg. C. 4. When the enzyme concentration increase 2 times, and 3 times, the enzymatic activity also increase, but not proportionally 5. The digestive gland Proteinase showed remarkably higher enzymatic activity than the intestinal Proteinase. 6. The digestive gland amylase brom the ascidion showed remarkably higher enzymatic activity than the heptaponcreatic amylase from shell fish (Turbo (Batillus) Cornutus Solander).).er).).).er).).

  • PDF

초음파 처리 활용 실시간 투과전자현미경 관찰용 금속 시편 전사 방법에 관한 연구 (A Study on the Method of Transferring Metal Specimens for Real-time Transmission Electron Microscopy using Ultrasonic Treatment)

  • 김황선
    • 소성∙가공
    • /
    • 제33권2호
    • /
    • pp.118-122
    • /
    • 2024
  • Micro-electromechanical systems (MEMS) based in-situ heating holders have been developed to enable high resolution imaging of heat treatment analysis. However, unlike the standard 3 mm metal disk specimens used in the furnace-based heating holder and general transmission electron microscopy holder, the MEMS-based in-situ heating holder requires thin specimens that can be penetrated by electrons to be transferred onto the MEMS chip. Previously, focused ion beam milling was used to transfer metal specimens, but it has the disadvantage of being expensive and the risk of specimen damage due to gallium ions. Therefore, in this study, we devised a method of transferring metallic materials by ultrasonic treatment using a transmission electron microscopy specimen made by electro jet polishing. A 3mm electropolished metal disk was placed in an appropriate solution, ultrasonicated, and then drop casted. The transfer of the specimen was successful, but it was confirmed that dislocations were formed inside the specimen due to ultrasonic treatment. This study provides a novel method for transferring metallic materials onto MEMS chips, which is cost-effective and less gallium ion damaging to the specimen. The results of this study can be used to improve the efficiency of heat treatment analysis using MEMS-based in-situ heating holders.