• Title/Summary/Keyword: metal specimen

Search Result 790, Processing Time 0.028 seconds

A Study on the Promotion. of Mechanical Properties for 200 Grade Maraging Steel (200 Grade 마르에이징강의 기계적성질 향상을 위한 연구)

  • 장경천;국중민;이동길;최병기
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.60-66
    • /
    • 2004
  • Hardness value decreased about 3% for annealed specimens and increased about 60% for one hour aged specimens. But the values of the other specimens aged two hours or more showed almost the same. The yield strength was the highest about 1,800㎫ in 0.06%Nb specimen having twice as much as the base meta1 specimen. Also, the elongation was the highest in 0.03%Nb specimen showing the same as base metal specimen. The higher aging temperature and the longer aging time, the higher fatigue life. On the other hand, the 0.03%Nb specimen showed the highest fatigue life which increased about 12% more than base metal specime. 0.06%Nb specimen aged at 482$^{\circ}C$ for 8 hours simultaneously satisfied the 250 grade strength and 200 grade elongation having the most superior mechanical properties.

  • PDF

AC Impedance Characteristics of the Corroded Hydrogen-Charged Zircaloy-4 Alloy (수소가 장입된 Zircaloy-4 합금의 부식 후의 Ac Impedance 특성)

  • Kim, Seon-Jae;Kim, Gyeong-Ho;Baek, Jong-Hyeok;Choe, Byeong-Gwon;Jeong, Yong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.9 no.2
    • /
    • pp.205-210
    • /
    • 1999
  • The 250ppm hydrogen-charged Zircaloy-4 sheets, homogenized at $400^{\circ}C$ for 72hrs in vacuum, were corroded under the autoclave conditions of $350^{\circ}C$, 2350psi. The corrosion behavior of the Zircaloy-4 sheets was evaluated by measuring their weight gains with the exposure time. The electrical characteristics were investigated in the ranges of 5000~1x10\ulcornerHz using AC impedance technique in 1N $H_2$$SO_4$aqueous solution. The corrosion rate of the hydrogen charged specimen was more rapid than the normal specimen at the early stage of the corrosion. With a longer corrosion time, however, the normal specimen corroded faster than the hydrogen-charged specimen. At the same time the hydrogen pickup in the hydrogen-charged specimen was more suppressed compared with the normal specimen. Such appears to be occurred because the impedance for the movement of the hydrogen ion into the metal was higher in the hydrogen-charged specimen compared to normal specimen at the interface between the oxide layer and the uncorroded metal. Thus the corrosion rate of the hydrogen-charged specimen was likely to be decreased with a longer corrosion time.

  • PDF

Evaluation of Sliding Friction Properties of Laser Surface Texturing Dimple Pattern with DLC Coating under GaInSn Liquid Metal Lubricant (액체금속(GaInSn)윤활하에서 DLC(ta-C) 코팅된 레이저 표면 텍스쳐링 딤플패턴의 미끄럼 마찰특성평가)

  • Kwon, Gyubin;Jang, Youngjun;Chae, Younghun
    • Tribology and Lubricants
    • /
    • v.37 no.3
    • /
    • pp.106-111
    • /
    • 2021
  • There are several studies on reducing the friction that occurs on the relative sliding contact surface of moving parts under extreme environments. In particular, a solid lubricated bearing is studied to solve the tribological problem with friction reduction and durability parts using solid lubricants (lead or silver) in a vacuum atmosphere. Galinstan is mainly used as a liquid metal lubricant, but it is inevitable to have limited tribological applications owing to its high coefficient of friction. Many researchers work on surface texturing for surface modification and precision processing methods. To increase durability and low friction, DLC coating with hydrophobicity is applied on the contact surface texture. Therefore, using an untextured specimen, a dimple specimen, and a DLC-coated dimple specimen under liquid metal lubrication, this paper presents the following experimental sliding friction characteristics in the sliding friction test. 1) The average coefficient of friction of the DLC-coated dimple specimen and dimple specimen are lower compared to that of a non-patterned specimen. 2) In the DLC-coated dimple specimens, the average coefficient of friction changes according to the change in the dimple density. 3) DLC-coated dimple specimens with a density of 12.5 have the lowest average coefficient of friction under 41.6 N of normal load and 143.3 RPM.

A study on strength reinforcement of one-sided reinforced hybrid laminates made of 22MnB5 and carbon fiber reinforced plastics (22MnB5 / 탄소섬유 강화 플라스틱으로 제작된 단면 보강 하이브리드 적층판의 강도 보강에 관한 연구)

  • Lee, Hwan-Ju;Jeon, Young-Jun;Kim, Dong-Earn
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.1-6
    • /
    • 2022
  • As environmental regulations are strengthened, automobile manufacturers continuously research lightweight structures based on carbon fiber reinforced plastic (CFRP). However, it is difficult to see the effect of strength reinforcement when using a single CFRP material. To improve this, a hybrid laminate in which CFRP is mixed with the existing body structural steel was proposed. In this paper, CFRP patch reinforcement is applied to each compression/tensile action surface of a 22MnB5 metal sheet, and it was evaluated through a 3-point bending experiment. Progressive failure was observed in similar deflection on bending deformation to each one-sided reinforced specimen. After progressive failure, the tensile reinforced specimen was confirmed to separate the damaged CFRP patch and 22MnB5 sheet from the center of the flexure. The compression reinforced specimen didn't separate that CFRP patch and 22MnB5, and the strength reinforcement behavior was confirmed. In the compression reinforced specimen, damaged CFRP patches were observed at the center of flexure during bending deformation. As a result of checking the specimen of the compression reinforcement specimen with an optical microscope, It is confirmed that the damaged CFRP patch and the reinforced CFRP patch overlapped, resulting in a concentrated load. Through the experimental results, the 22MnB5 strength reinforcement characteristics according to the reinforcement position of the CFRP patch were confirmed.

Containing Heavy Metal Contaminants Using Soil-Cement Column Barrier (심층혼합기둥체 차수벽을 이용한 중금속 오염물질의 이동 제어)

  • 정문경;천찬란;이주형;김강석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.821-826
    • /
    • 2003
  • Laboratory experiments were peformed to understand physical properties of soil-cement column under the influence of acidic flow including metal contaminants and its retaining capacity against metal migration. The contaminant used in this study was nitric acid with Cu and Cd. The Permeability of soil-cement column decreased when pH of the column began to drop below 12. Decreases in pH led to significant reduction of compressive strength of clayey soil-cement specimen, while relatively marginal reduction for sandy soil-cement specimen. The metal contaminants did not leachate from soil-cement column until pH of soil-cement dropped below 7∼8 for Cu and 9∼10 for Cd. Metal contaminants were precipitated and trapped inside the soil-cement column at pHs higher than those mentioned as verified with metal analysis and visual inspection. This indicated that soil-cement column not only performs well as a cut-off wall, but also helps alleviating the level of contamination of the surrounding environment.

  • PDF

Characteristics of Bending Strength on Coating Condition of Metal Surface Polyurethan Coating Material (금속표면에 폴리우레탄코팅한 소재의 코팅조건 변화에 따른 굽힘강도 특성)

  • 이강길
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.124-129
    • /
    • 2001
  • The research on anticorrosive of valve for ship, waterworks, and drainage system is very important. The purpose of this paper is to develop the metal/polyurethan adhesive technique at insider of the value to prevent corrosion in the value. It is performed to the bending strength test by using metal /polyurethan in the metals (SB41, Al6061). It is investigated to the effects of bending strength on curing temperature, preheating time and curing time, and to the fracture mechanism of metal/polyurethan adhensived specimen. As a results, we find that the bending strength is the highest at curing temperature of 11$0^{\circ}C$ and the curing time is 60 minutes in metal/polyurethan adhesive specimen.

  • PDF

THE EFFECTS OF SURFACE TREATMENT OF FRACTURED METAL-CERAMIC CROWN ON BOND STRENGTH OF REPAIR RESIN (파절된 도재전장관의 표면처리 방법에 따른 수복레진의 접합강도에 관한 연구)

  • Jeong, Ae-Ri;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.117-127
    • /
    • 1991
  • The purpose of this study was to evaluate the effect of surface treatment of fractured metal-ceramic crown on bond strength of porcelain repair resin. The specimens were divided into two groups for metal specimens add five groups for porcelain specimens by surface treatment methods. the metal specimens were treated by 2 methods. : micro-sandblasting with $50{\mu}m$ aluminum oxide and grinding with diamond bur. The porcelain specimens were treated by 5 methods : micro-sandblasting with $50{\mu}m$ aluminum oxide, grinding with diamond bur, etching with porcelain etching agent, combination of micro-sandblasting and etching procedure, and combination of grinding and etching procedure. After surface treatment, each specimen was bonded with composite resin and the bond strength was measured and the surface texture was observed by scanning electromicroscope(SEM). The results were as follows : 1. There was significant difference in shear bond strength between metal specimen and prorcelain specimen. 2. Bood strength of metal specimens treated with diamond bur was higher than that treated with $50{\mu}m$ aluminum oxide sandblasting. 3. Bond strength of porcelain specimen treated with diamond bur was higher than that treated with $50{\mu}m$ aluminum oxide sandblasting and porcelain etching agent. 4. There was no significant difference in shear bond strength between the group treated with diamond bur and combined treatment groups respectively. 5. The large undercuts were observed in group treated with diamond bur by SEM.

  • PDF

Corrosive Characteristics of Metal Materials by a Sulfate-reducing Bacterium (황산염환원미생물에 의한 금속재료의 부식 특성)

  • Lee, Seung Yeop;Jeong, Jongtae
    • Journal of the Mineralogical Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.219-228
    • /
    • 2013
  • To understand characteristics of biogeochemical corrosion for the metal canisters that usually contain the radioactive wastes for a long-term period below the ground, some metal materials consisting of cast iron and copper were reacted for 3 months with D. desulfuricans, a sulfate-reducing bacterium, under a reducing condition. During the experiment, concentrations of dissolved metal ions were periodically measured, and then metal specimen and surface secondary products were examined using the electron microscopy to know the chemical and mineralogical changes of the original metal samples. The metal corrosion was not noticeable at the absence of D. desulfuricans, but it was relatively greater at the presence of the bacterium. In our experiment, darkish metal sulfides such as mackinawite and copper sulfide were the final products of biogeochemical metal corrosion, and they were easily scaled off the original specimen and suspended as colloids. For the copper specimen, in particular, there appeared an accelerated corrosion of copper in the presence of dissolved iron and bacteria in solution, probably due to a weakening of copper-copper binding caused by a growth of other phase, iron sulfide, on the copper surface.

A Study on a micro dynamic tester development for a micro property measurement of a micro metal specimen (마이크로 금속 박판의 동적 물성치 측정을 위한 마이크로 동적 시험 장치 개발에 관한 연구)

  • Lee, Jin-Pyo;Lee, Hye-Jin;Hwang, Jai-Hyuk;Lee, Nak-Kyu;Bae, Jae-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.163-168
    • /
    • 2006
  • In a micro-unit of electronic-machine, vibration can be excited by a small impact, and this vibration acts as a fatigue load. To measure the vibration effect on the micro unit, a micro dynamic tester is needed to test a micro specimen. In this paper, it has confirmed a movement of the PZT(piezo actuator) to use a sine signal. And, it has confirmed a fracture of specimens by using a tension-tension input signal in PZT. A metal-material property in the micro scale has been tested to compare with the macro scale. A fatigue test has been conducted by using PZT actuator to give a bending-tension effect.

  • PDF

Fatigue Properties of Friction Weld According to the Location of Small Artificial Defect (미소인공결함의 위치에 따른 마찰용접부의 피로특성)

  • 이상열;정재강
    • Journal of Welding and Joining
    • /
    • v.19 no.6
    • /
    • pp.608-613
    • /
    • 2001
  • In this study, the rotary bending fatigue test was carried out with two kinds of base metal, martensite stainless steel STR3 and austenite stainless steel STR35 and the dissimilar friction welded material with them. To compare the fatigue fifes according to the notch positions, the small circular defect was worked on the bonded line, 1.0mm and 0.5mm distance form the bonded line. The fatigue limits of the STR3 and STR35 base metal were 429.0MPa and 409.4MPa respectably. In comparison with fatigue life at the same notch positions, the STR35 specimens showed about 190% for base metal, 82% for 1.0mm distance notched specimens higher than that of the STR3. But the fatigue life of the 0.5mm distance notched STR35 specimen showed about 35% lower than that of the STR3 specimen. And the bonded line notched specimen was much lower fatigue life than the other specimens because of separation of the bonded line.

  • PDF