• Title/Summary/Keyword: metal discoloration

Search Result 33, Processing Time 0.027 seconds

A STUDY ON FRACTURE STRENGTH OF COLLARLESS METAL CERAMIC CROWN WITH DIFFERENT METAL COPING DESIGN (금속코핑 설계에 따른 Collarless Metal Ceramic Crown의 파절강도에 관한 연구)

  • Yun, Jong-Wook;Yang, Jae-Ho;Chang, Ik-Tae;Lee, Sun-Hyung;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.454-464
    • /
    • 1999
  • The metal ceramic crown is currently the most popular complete veneer restoration in dentistry, but in many cases, the metal cervical collar at the facial margin is unesthetic and unacceptable. Facial porcelain margin has been used in place of it. But this dose not solve the problems, such as dark gingival discoloration and cervical opaque reflection of porcelain veneer. Recently, metal copings which were designed to terminate its labio-cervical end on the axial walls coronal to the shoulder have been clinically used to solve the esthetic problem of metal ceramic crown. But in this design, porcelain veneer of labio-cervical area which is not supported by metal may not be able to resist the stress during cementation and mastication. The purpose of this study was to evaluate fracture strength and fractured appearance of crowns according to different coping designs. A resin maxillary left central incisor analogue was prepared for a metal ceramic crown, and metal dies were made with duplication mold. Metal copings were made and assigned to one of four groups based on facial framework designs: group 1, coping with 0.5mm metal collar; group 2, metal extended to the shoulder; group 3, metal extended to 1mm coronal tn the shoulder: group 4, metal extended to 2mm coronal to the shoulder. Copings and crowns were adjusted to be same size and thickness, and cemented to metal dies with zinc phosphate cement by finger pressure. Fracture strength was measured with Instron Universal Testing Machine. Metal dies were anchored in Three-way-vice at 3mm below finish line and at $130^{\circ}$ inclined to the long axis of the crown. Load was directed lingually at 2mm below midincisal edge. Load value at initial crack and at catastrophic fracture was recorded. The results obtained were as follows : 1. Fracture strength values at initial crack were higher in groups 1, 2 than in groups 3, 4 but this difference was not statistically significant(P<0.05). 2. Conventional metal collared crown had greater catastrophic fracture strength than any other collarless crowns. 3. The greater the labial metal coping reduction, the lower the catastrophic fracture strength of crowns but when more than 1mm of labial metal reduction was done, the difference in strengths was not statistically significant(p<0.05). 4. The strongest collarless coping design was group 2.

  • PDF

Study on Application of Urethane Materials for Hardening of Metal Artifacts (금속유물 강화처리를 위한 우레탄 수지의 적용성 연구)

  • Lee, Ho-Yeon;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.27 no.4
    • /
    • pp.415-420
    • /
    • 2011
  • Urethane coating agent was made up in order to prevent corrosion on metal relics. This urethane coating agent was designed to solve problems linked to gloss and discoloration caused by existing acrylic coating agent which is mainly applied to metal relics. For the purpose, the urethane coating agent was made up which has lower gloss and slight color change. This coating agent formed thinner coating layer with excellent adhesion compared to the existing agent and has outstanding resistance to the surface oxidization of metal relics and water repellent on the surface. In addition, the agent is considered a stable coating agent replacing current acrylic coating agent with showing easy dissolution in organic solvents such as acetone, toluene and xylene with excellent result in reversible reaction.

Influence of pH, Temperature, Ionic Strength and Metal Ions on the Degradation of an Iridoid Glucoside, Aucubin, in Buffered Aqueous Solutions (완충 수용액중 pH, 온도, 이온강도 및 금속이온이 Aucubin의 분해에 미치는 영향)

  • Chun, In-Koo;Cho, Young-Mee
    • Journal of Pharmaceutical Investigation
    • /
    • v.25 no.3
    • /
    • pp.239-247
    • /
    • 1995
  • The physico-chemical stability of aucubin, a hepatoprotective iridoid glucoside, in buffered aqueous solutions was studied using a stability-indicating reversed-phase high performance liquid chromatography. The degradation of aucubin followed the pseudo-first-order kinetics. In strong acidic regions, aucubin was rapidly degraded by the specific acid catalysis, forming dark brown precipitates. From the rate-pH profiles, it was found that aucubin was most stable at the pH of about 10. From the temperature dependence of degradation, activation energies for aucubin at pH 2.1 and 4.9 were calculated to be 22.0 and 24.3 kcal/mole, respectively. The shelf-life $(t_{90%})$ for aucubin at pH 9.07 and $20^{\circ}C$ was predicted to be about 603 days. A higher ionic strength accelerated the degradation of aucubin at pH 4.01. The effect of metal ions on the degradation rate of aucubin at pH 7.16 was in the rank order of $Cu^{2+}\;>\;Fe^{3+}\;>\;Co^{2+}\;>\;Fe^{2+}\;>\;Mg^{2+}$. On the other hand, $Mn^{2+}\;and\;Ba^{2+}$ slowed the degradation rate.

  • PDF

Effects of Wood Materials on Metal Corrosion - Oddy test - (나무재료가 금속부식(金屬腐蝕)에 미치는 영향(影向) - Oddy test -)

  • Lee, Sungeun;Roh, Hyunsook;Yi, Yonghee
    • Conservation Science in Museum
    • /
    • v.5
    • /
    • pp.31-36
    • /
    • 2004
  • The purpose of this experiment was to check the effects on metal corrosion of the 6 types of tree (Ash tree, Japanese cedar, black walnut, western hemlock, paulownia coreana and maple) which are currently being used, or the use of which is under study, by the Museum. As a method of test, an Oddy Test was conducted where the materials to be tested and the metal test piece are exposed to a specified temperature and humidity for a long period of time and the effects of materials on the test piece are observed. The results of the Oddy Test conducted on all 6 types of tree showed slight difference in the form of metal corrosion, and except for the blank, corrosion occurred on the entire surface of most iron (Fe) and lead (Pb) test pieces. Minor level of discoloration was noted in all test pieces of copper (Cu) even though different levels.

Stability of Naphthoquinone Pigments Isolated from the Roots of Lithospermum erythrorhizon by Various Temperatures and Metal Ions (자근(紫根)으로부터 분리한 Naphthoquinone류 색소의 온도 및 금속에 대한 안정성)

  • Chung, Mi-Sook;Lee, Mie-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.97-100
    • /
    • 1995
  • The pigments of acetylshikonin and isobutylshikonin isolated from the roots of Lithospermum erythrorhizon were determined over a period of storage for their stabilities influenced by temperatures and metal ions. In dark condition, both pigment solution were unstable at 488 and 560 nm; alcoholic solutions of acetylshikonin pigment were stable at $25^{\circ}C$ and $50^{\circ}C$ for 1 hour, but isobutylshikonin showed severe discoloration within 1 hour at $95^{\circ}C$ . Buffered solutions of acetylshikonin tended to be discolored with the addition of $Fe^{++}$, while those of isobutylshikonin with $Fe^{++}$ and $Cu^{++}$. These studies indicated that acetylshikonin and isobutylshikonin can be used in foods as the natural colorant under selected conditions in case of considering storage temperature and metal ions.

  • PDF

A Study on the Oxidation Behavior of Metal Materials Applicable to Oxidizer Rich Pre-Combustor (산화제 과잉 연소기에 활용 가능한 금속재료의 산화 거동에 관한 연구)

  • Shin, Donghae;Yu, Isang;Shin, Minku;Ko, Youngsung;So, Younseok;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.118-125
    • /
    • 2019
  • Metals exposed to high temperature/high pressure/oxidant excess environment of an oxygen excess pre-combustor may undergo rapid oxidation. In this study, the test facility to simulate the high temperature/high pressure/oxidant excess environment was constructed and the oxidation resistance evaluation was carried out for various metal materials. As a result, the discoloration of the metallic materials, the change in the surface roughness and the peeling of the metal surface were observed, and the weight change was also observed. The resulst showed that oxidation-resistant coating of a metal material of the combustor is indispensably required, and the use of XM-19, which has the highest content of Cr and Ni, is expected to provide more structural stability.

Deterioration Degree and Material Research of Metal Archival Objects (금속류 행정박물의 손상도 및 재질 연구)

  • Park, Hyung-Ho;Cho, Nam-Chul;Na, Mi-Sun
    • Journal of Conservation Science
    • /
    • v.26 no.1
    • /
    • pp.33-41
    • /
    • 2010
  • The archival objects are tangible evidence reflecting public work as forming archives which are administrative, historic, symbolic, cultural and artistic value. They are produced from the various countries so that they have different material and manufacture techniques. However there are difficulties in conservation and management because the material investigation and conservation management system are not established. Therefore this research presents fundamental data for the efficient conservation management by material investigation and condition check metal archival objects. Among the public official presents made of metal, 12 pieces which are discoloration, oxidation, loss or crack are chosen for this research. In order to examine extensive condition of metal archival objects, the condition check card used from the domestic museum and the national museum in Japan are collected and then the new check card is produced. X-ray is used to know the making technique, binding means between different material. Portable-XRF is also used for the chemical composition analysis of metal archival objects, and then classifying respectively according to their material. As a result of condition check, it is possible to investgate the appearance character, deteriorated parts and weak parts of structure. Also P-XRF could find out the composition of metal archival objects which is different from existing condition check card. Therefore the research results can be used as fundamental data for further conservation and management as well as long-term conservation.

The Stability Appraisement on Cultural Property Material with the Replacing Fumigation Gas of Methyl Bromide (Methyl Bromide를 대체하는 훈증 가스의 문화재 재질 안정성 평가)

  • Kang, Dai-Ill
    • Journal of Conservation Science
    • /
    • v.25 no.3
    • /
    • pp.283-291
    • /
    • 2009
  • Methyl Bromide that was used as fumigation gas turned out to be the substance of destroying the ozone layer. For that reason, at the Montreal Protocol in 1987 the use of methyl bromide was forbidden starting 2005 in the advanced country. Also according to the 2007 Bali Protocolly methyl bromide is expected to be forbidden and therefore the purpose of this study is to find out the effects of substitution fumigation gas (Ethylene Oxide+HFC 134a, Methyl Iodide, Cyanogen and Argon) on the metal(silver, copper and iron), wood(oregon pine), pigment(yellow, red, blue, white and black), textile(hemp, ramie, jute, silk1 and silk2 / indigo, safflower and cork) and paper. After the fumigation test, ethylene oxide+HFC 134a did not have changes in the weight and color of the material itself before and after the experiment. On exterior alteration, color change occurred partly on paper and metal. Also, in most materials color change extent was 0.5 to 1.5 on the average and showed scanty difference. The materials after the fumigation test with methyl iodide did not show weight changes after the test. However, color changes more than 1.0 was shown in most of the materials especially in dyed textile material. In blue pigment, the discoloration on the surface could be seen by naked eyes. Fumigation test with cyanogen gas did not show weight changes and discoloration is more than 1.5 before and after the test. The weight changes of test materials with the argon gas was decreased about 3 to 6%. It can be observed that discoloration on paper was generated. Color changes can be seen on jute dyed with safflower and cork for two weeks with argon gas and the extent was 6.3 and 6.0.

  • PDF

Study on Reusable Electrodes for Personal Electrocardiography

  • Kim, Jonghoon;Yoon, Gilwon
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.340-344
    • /
    • 2018
  • Electrodes are an important part of electrocardiography (ECG); disposable electrodes have been extensively used. However, personal ECG monitoring devices for Internet of Things applications require reusable electrodes. As there have been no systematic studies on the characteristics of reusable electrodes to date, we conducted this study to assess the performance and feasibility of electrodes with different materials. We built reusable electrodes using twelve different metallic materials, including commonly used copper, silver, zinc, plating materials, chemically inert titanium, stainless steel, and aluminum. Each electrode was fabricated to a size of $5{\times}10mm$. Their characteristics such as offset, baseline drift, stabilization time, and chemical inertness were compared. A personal ECG monitoring system was used to test the manufactured electrodes. The performances of the Ag, Cu, and Zn electrodes were better than the performances of other electrodes. However, these materials may not be used owing to the chemical changes that occur when the electrodes are in contact with the skin, such as discoloration and corrosion, which deteriorate their electrical characteristics. Titanium, stainless steel, and aluminum are chemically stable. The titanium electrode showed the best performance among the three, and it is our recommendation as a material for manufacturing reusable electrodes.

Corrosion of Dental Au-Ag-Cu-Pd Alloys in 0.9 % Sodium Chloride Solution

  • Chiba, Atsushi;Kusayanagi, Yukiharu
    • Corrosion Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.19-22
    • /
    • 2005
  • Two Au-Ag-Cu-Pd dental casting alloys (Au:12% and 20%) used. The test solutions used 0.9 % NaCl solution (isotonic sodium chloride solution), 0.9 % NaCl solution containing 1 % lactic acid, and 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_2S$. The surface of two samples in three sample solutions was not natural discoloration during one year. The alloy containing 12 % gold was easily alloyed and the composition was uniform comparing with the alloy containing 20 % gold. The rest potentials have not a little effect after three months. The kinds of metals could not definitely from the oxidation and reduction waves of metal on the cyclic voltammograms. The dissolutions of gold and palladium were 12 % Au sample in the 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_{2}S$. The pH of solution had an affect on dissolution of copper, and sulfur ion had an affect on dissolution of silver. The copper dissolved amount from 20 % gold sample was about 26 times comparing with that of 12 % gold sample in the 0.9 % solution containing 1 % lactic acid. Corrosion products were silver chloride and copper chloride in NaCl solution, and silver sulfide and copper sulfide in NaCl solution containing $Na_{2}S$.