• Title/Summary/Keyword: metal core

Search Result 622, Processing Time 0.028 seconds

Preparation of Composite Particles via Electroless Nickel Plating on Polystyrene Microspheres and Effect of Plating Conditions (무전해 니켈 도금된 폴리스티렌 복합 입자 제조 및 도금 조건의 영향)

  • Kim, Byung-Chul;Park, Jin-Hong;Lee, Seong-Jae
    • Polymer(Korea)
    • /
    • v.34 no.1
    • /
    • pp.25-31
    • /
    • 2010
  • Polymer core and metal shell composite particles have been prepared by the electroless nickel plating on the surface of monodisperse polystyrene microspheres. Various sizes of polystyrene particles with highly monodisperse state could be synthesized by controlling the dispersion medium in dispersion polymerization. Electroless nickel plating was performed on the polystyrene particle with diameter of $3.4\;{\mu}m$. The morphology of polystyrene/nickel composite particles was investigated to see the effect of the plating conditions, such as the $PdCl_2$ and glycine concentrations and the dropping rate of nickel plating solution, on nickel deposition. With $PdCl_2$ and glycine concentrations at more than 0.4 g/L and 1 M, respectively, more uniform nickel layer and less precipitated nickel aggregates were formed. At the given plating time of 2 h, the same amount of plating solution was introduced by varying the dropping rate. Though the effect of dropping rate on particle morphology was not noticeable, the dropping rate of 0.15 mL/min for 60 min showed rather uniform plating.

Immediate implant placement into extraction sites with periapical lesions in the esthetic zone: a case report (치근단 병소를 가진 치아의 발치 후 즉시 임플란트 식립 및 보철을 통한 심미성 회복)

  • Yi, Jae-Young;Kim, Jee-Hwan;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.191-197
    • /
    • 2012
  • Esthetics is important in restoring maxillary anterior area. Alveolar bone resorption and loss of interdental papilla may be minimized by immediate implantation. Previous studies showed successful results with the immediate implantation in healthy extraction socket, while many of these studies objected the immediate implantation into extraction sites with periapical lesions. Recent studies, however, reported successful results of the immediate implantation into extraction sites with periapical lesions with careful debridement of extraction sockets and general medication of antibiotics prior to implantation. A 73-year-old female visited the department of Prosthodontics in ${\bigcirc}{\bigcirc}$ University Dental Hospital with the chief complaint of fallen post-core and crown on left maxillary incisor. Although the incisor was with vertical root fracture and periapical lesion, the immediate implantation following the extraction of tooth was planned. Thorough socket debridement, irrigation with chlorhexidine, and tetracycline soaking were followed by immediate implantation. The general medication of antibiotics (Moxicle Tab.$^{(R)}$, 375 mg) was prescribed before and after the surgery. Immediate provisional restoration was delivered two days after the surgery, and the definitive metal-ceramic restoration was placed about six months later after reproducing the emergence profile from the provisional restoration. This case presents satisfying result esthetically and functionally upto two years after the placement of prosthesis with the harmonious gingival line and no loss of marginal bone.

Reconstruction of Changes in Eolian Particle Deposition Across the Mid-Pleistocene Transition in the Central Part of the North Pacific (중기 플라이스토세 전이기 전후 북태평양 중앙 해역 퇴적물에 기록된 풍성 퇴적물 입자 퇴적 양상 변화 복원)

  • Lee, Sojung;Seo, Inah;Hyeong, Kiseong
    • Ocean and Polar Research
    • /
    • v.41 no.4
    • /
    • pp.275-288
    • /
    • 2019
  • We investigated flux, grain size distribution, Nd-Sr isotope composition, mineral composition, and trace metal composition (REEs and Sc) of inorganic silicate fraction (ISF, mainly Asian dust with an unrestricted amount of volcanic materials) deposited during 600~1000 ka across the Mid-Pleistocene Transition at core NPGP 1401-2A (32°01'N, 178°59'E, 5205m) taken from the central part of the North Pacific. Our results reveal about a 2-fold increase in ISF flux after 800 ka, which is associated with an increase in La/Sc and a decrease in mean grain size. Asian dusts are finer than volcanic materials and La/Sc increases with the enhanced contribution of Asian dusts. Thus, increased flux after 800 ka can be explained by the increased contribution of Asian dusts relative to volcanic materials, likely due to an intensified Westerly Jet (WJ) and the drying of the Asian continent after the MPT. Mean grain size of ISF varies systematically in relation to glacial-interglacial cycles with a decrease during glacial stages, which is consistent with the previous results in the study area. Such a cyclical pattern is also attributed to the increase in the relative contribution of Asian dusts over volcanic components in glacial stages due to intensified WJ and drying of the Asian continent. Thus, it can be concluded that climate changes that had occurred across the MPT were similar to those of interglacial to glacial transitions at least in terms of the dust budget. Different from the Shatsky Rise, however, compositional changes associated with glacial-interglacial mean grain size fluctuations are not observed in Nd-Sr isotope ratios and trace element composition in our study of the Hess Rise. This may be attributed to the location of the study site far (> 4,000 km) from the volcanic sources. The volcanic component at the study site comprises less than 10% and varies within 3% over glacial-interglacial cycles. Such a small variation was not enough to imprint geochemical signals.

Benthic Fluxes of Ammonia and Lead in Lake Shihwa (시화호에서 암모니아와 납의 저층용출)

  • Han, Myong-Woo;Park, Yong-Chul;Huh, Sung-Hoi
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.2 no.2
    • /
    • pp.69-77
    • /
    • 1997
  • A 12-cm long sediment core was collected from a station in Lake Shihwa where high salinity-anoxic deep water is isolated from low salinity-oxic surface water by a strong halocline barrier. Unprecedented concentrations of porewater ammonia and lead are encountered: at 9 cm sediment depth ammonia builds up to 1420 ${\mu}M$ and at 3 cm lead to 1348 nM. As they are stable in anoxic condition, high concentrations of ammonia and lead suggest a development of notorious anoxic condition in the benthic environment of the lake. The degree of pollution of the deep water is likely to be directly proportional to the magnitude of benthic flux, because the deep water is isolated from the surface water by the halocline. Apparent coincidence of the ammonia residence time in the deep water with the elapsing time after the completion of the artificial lake construction, as about three years, suggests that the deep water pollution is being progressed entirely by benthic flux at least with respect to ammonia. The residence time for lead is such a short 20 days that it suggests a rapid return of the bottom water lead, which is originated from porewater by benthic flux, back to sediments probably as metal sulfide phases. The speculation on the return of lead as sulfide phases is likely to be supported by high concentration of hydrogen sulfide in the deep water and by high sinking rate of non-organic particles in Lake Shihwa.

  • PDF

Analysis of Frequency Response Curve for Conduction-Cooled Power Capacitors (전도 냉각 파워 커패시터의 주파수 응답 곡선 분석)

  • An, Gyeong Moon;Kim, Hiesik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.123-130
    • /
    • 2016
  • High-frequency induction heating equipment can heat the metal by applying a High-Frequency power to the resonant circuit. The resonance circuit is composed of the work coil and the conduction-cooled power capacitor, it influences the performance of the heat treatment equipment according to the characteristics of the capacitor. However, dependence on conduction-cooled power capacitor's import is high due to lack of core technology research and development. Minimizing the generation of internal heat transmitted inside during LC resonance, reduce the reactive power loss, there is a need for a capacitor within the voltage characteristic outstanding. To implement localization it is vital that prior study of the analysis on the frequency response characteristic for the finished capacitor advanced manufacturer be implemented. Studying the interpolation method to read the value at any point of the characteristic curve for a given log-log scale was applied to the analysis tool of the capacitor by my proposed algorithm. The simulation for reproducing frequency response curves was attempted by assuming a capacitor in a simplified series equivalent RC circuit to obtain the equivalent series resistance value. It was confirmed that the reproduction rate was the result value above 83% as compared to the simulation of the properties and characteristics on the actual reactive power for Peak value, and that the algorithm can be applicable when analyzing and predicting the characteristic curves of a simpled model capacitor.

Spatial distribution of heavy metals in soils and groundwater at the 2000 Olympic Games site, Sydney, Australia

  • Suh, Jeong-Yul
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.70-78
    • /
    • 2004
  • The current study was undertaken to evaluate the hydrogeochemical implications of heavy metals (Cr, Cu, Pb, Zn) in both soils and groundwater in reclaimed lands of Sydney's 2000 Olympic Games site at Homebush Bay in Port Jackson, Sydney. The Olympic Games site can be divided into three areas, i.e. 'reclaimed areas' were previously estuarine, and were filled with waste materials and are now above present high tide level, whereas 'landfill areas' are areas where deposition of waste materials occurred above sea level. No deposition of waste took place in 'non-infilled areas'. 4513 soil core samples and 101 groundwater samples were analyzed for Cr, Cu, Pb, Zn. The mean heavy metal (Cr, Cu, Pb, Zn) concentrations in soils of the study area revealed the order of reclaimed (greatest), landfill and non-infilled area (smallest), whereas in groundwater it is all shown the order of landfill, reclaimed and non-infilled area, except for Pb. Mean Pb concentration in soils derived from the three land types at the Olympic Games site revealed the order of reclaimed area(174 $\mu\textrm{g}$/g), landfill area (102 $\mu\textrm{g}$/g) and non-infilled area (48 $\mu\textrm{g}$/g). Results reveal that soils contaminated by Cr, Cu, Pb and Zn in reclaimed/landfill areas are associated with dumped materials. No relationship could be established between soil and groundwater concentrations of heavy metals (Cr, Cu, Pb, Zn) in the landfill, reclaimed and non-infilled areas of the Olympic site, probably due to the varied nature of the materials deposited at the Olympic site.

A Lab-Made Wound Maker for Analysis of Cell Migration in a 96-Well Plate (세포 이동능력 분석을 위한 96-Well Plate 전용 Lab-Made Wound Maker)

  • Lee, Tae Bok;Kim, Hwa Ryoung;Park, Seo Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.53-61
    • /
    • 2020
  • Cell migration is a central process for recovering from wounds triggered by physical distress besides embryogenesis and cancer metastasis. Wound healing assay is widely used as a fundamental research technique for investigation of two-dimensional cell migration in vitro. The most common approach for imitating physical wound in vitro is mechanical scratching on the surface of the confluent monolayer by using sharp materials. The iron metal pin with a suspension spring for fine adjustment of the orthogonal contact surface between the scratching point and the individual bottom of multi-well plate with planar curvatures were adopted for the creative invention of a 96-well plate wound maker. While classic tips drew diverse and zigzag scratching patterns on the confluent monolayer, our wound maker displayed synchronized linear wounds in the middle of each well of a 96-well plate that was seeded with several cell lines. Given that several types of multi-well plates commercially available are compatible with our lab-made wound maker for creating uniform scratches on the confluent monolayer for the collective cell migration in wound healing assay, it is certain that the application of this wound maker to the real-time wound healing assay in high content screening (HCS) is superior than utilization of typical polypropylene pipette tips.

Optimization of Conditions for the Preparation of W/O Emulsion Containing Eugenolchitosan (Eugenolchitosan 함유 유중수적형 유화 형성 조건 최적화)

  • Kim, Je-Jung;Chang, Pahn-Shick;Jung, Byung-Ok;Park, Dong-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.423-428
    • /
    • 2003
  • Stabilities of W/O emulsions containing eugenolchitosan (EuCs) prepared from chitosan and eugenol were compared to determine the optimal conditions for the ratio of water (core phase) to corn oil (continuous phase), the concentration of EuCs, storage temperature, and the extent of homo-mixing. The optimal ratio of water to corn oil was 2:3 (w/w). The effects of EuC concentrations, and singular vs. binary system of emulsifiers on the storage stability of the emulsion were investigated with EuCs and polyoxyethylene sorbitan monolaurate. The emulsion was stable, showing more than 95% emulsion stability index (ESI) value, when the concentration of EuCs was more than 0.18% (w/v). ESI value of binary emulsifier system was almost equal to that of singular emulsifier system at the concentration of 0.18% (w/v). At this singular emulsifier system, the W/O emulsion formed by EuCs had ESI value of 100%. The optimal concentration of EuCs was determined as 0.18% (w/v). The highest stability of the emulsion was obtained from the homo-mixing at 11,000 rpm for 10 sec and the storage temperature ranging $25{\sim}65^{\circ}C$. EuCs produced from this study was mutagenecity-negative on Ames test and contained no heavy metal ions.

Marginal Fidelity and Fracture Strength of OPTIMAL PRESSABLE CERAMIC Crown according to Margin Types (OPTIMAL PRESSABLE CERAMIC 금관의 변연형태에 따른 변연적합도와 파절강도에 관한 연구)

  • Lee, Ju-Seog;Kim, Ki-Suk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.13-25
    • /
    • 2000
  • Optimal Pressable Ceramic is one of the all-ceramic restorations with a shaded translucent pressed core and layering porcelains. The purpose of this study was to evaluate the marginal fidelity according to margin types and measurement sites, and to evaluate fracture strength according to margin types. Twenty seven OPC crowns made according to 3 types of cervical finishing lines were used in this study. Marginal gaps were measured before and after cementation. A Steromicroscope(SZ-ST(R), Olympus, Japan) was used to measure the space between the margin of OPC crown and the finishing line of metal model. Marginal gaps were measured at the labial, mesial, lingual and distal site, which were demonstrated in advance. Fracture strength testing was carried out using an Instron(Model M100EC, Mecmesin, England) at a cross head speed of 5 mm/min. All crowns were loaded until catastrophic failures occurred. The result were as follow: 1. In comparison according to variable margin before cementation, the marginal gap were increased in chamfer margin($47.50{\pm}18.39{\mu}m$), $120^{\circ}$shoulder margin ($55.21{\pm}14.4{\mu}m$) and $90^{\circ}$shoulder margin($71.18{\pm}13.30{\mu}m$) in ascending order, and there were significant differences between chamfer margin and $90^{\circ}$shoulder margin, $120^{\circ}$shoulder margin and between $120^{\circ}$shoulder margin and $90^{\circ}$shoulder margin respectively(p<0.05). 2. In comparison according to variable margin after cementation, the gap discrepancies were increased in chamfer margin($60.78{\pm}30.37{\mu}m$), $120^{\circ}$shoulder margin($66.67{\pm}11.18{\mu}m$) and $90^{\circ}$shoulder margin($85.78{\pm}17.23{\mu}m$) in ascending order, but there was significant difference only between chamfer margin and $90^{\circ}$shoulder margin(p<0.05). 3. Labio-lingual points showed a better marginal fidelity than that of proximal point(p<0.05). 4. Chamfer margin($48.76{\pm}8.45kgf$) showed higher fracture strength than $120^{\circ}$ shoulder margin($40.57{\pm}7.90kgf$) and $90^{\circ}$ shoulder margin(32.7.90kgf) (p<0.05), but there was significant difference only between chamfer margin and $90^{\circ}$ shoulder margin(p<0.05).

  • PDF

Effects of Curing Temperature on the Optical and Charge Trap Properties of InP Quantum Dot Thin Films

  • Mohapatra, Priyaranjan;Dung, Mai Xuan;Choi, Jin-Kyu;Jeong, So-Hee;Jeong, Hyun-Dam
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.263-272
    • /
    • 2011
  • Highly luminescent and monodisperse InP quantum dots (QDs) were prepared by a non-organometallic approach in a non-coordinating solvent. Fatty acids with well-defined chain lengths as the ligand, a non coordinating solvent, and a thorough degassing process are all important factors for the formation of high quality InP QDs. By varying the molar concentration of indium to ligand, QDs of different size were prepared and their absorption and emission behaviors studied. By spin-coating a colloidal solution of InP QD onto a silicon wafer, InP QD thin films were obtained. The thickness of the thin films cured at 60 and $200^{\circ}C$ were nearly identical (approximately 860 nm), whereas at $300^{\circ}C$, the thickness of the thin film was found to be 760 nm. Different contrast regions (A, B, C) were observed in the TEM images, which were found to be unreacted precursors, InP QDs, and indium-rich phases, respectively, through EDX analysis. The optical properties of the thin films were measured at three different curing temperatures (60, 200, $300^{\circ}C$), which showed a blue shift with an increase in temperature. It was proposed that this blue shift may be due to a decrease in the core diameter of the InP QD by oxidation, as confirmed by the XPS studies. Oxidation also passivates the QD surface by reducing the amount of P dangling bonds, thereby increasing luminescence intensity. The dielectric properties of the thin films were also investigated by capacitance-voltage (C-V) measurements in a metal-insulator-semiconductor (MIS) device. At 60 and $300^{\circ}C$, negative flat band shifts (${\Delta}V_{fb}$) were observed, which were explained by the presence of P dangling bonds on the InP QD surface. At $300^{\circ}C$, clockwise hysteresis was observed due to trapping and detrapping of positive charges on the thin film, which was explained by proposing the existence of deep energy levels due to the indium-rich phases.