• Title/Summary/Keyword: metal concentration

Search Result 2,782, Processing Time 0.03 seconds

Study on the Anode Electrode Reaction in the Metal-Air Cell (금속-공기전지의 Anode전극 반응에 관한 연구)

  • Kim, Yong-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.12
    • /
    • pp.1002-1006
    • /
    • 2010
  • In this study, magnesium (Mg), zinc (Zn) and aluminium (Al) as anode electrode and the solution of NaCl dissolved with 2~20 wt% as electrolytes were used for the metal-air cell. The open circuit voltage, short circuit current and I-V characteristics upon different kinds of anode electrode and electrolyte concentration were investigated. The open circuit voltage, initially about 1.45 V, rises to 1.6 V during the first 10 minutes indicating the necessity of an induction time to activate the catalyst on the air cathode. The short circuit current increases with an increased concentration of NaCl, causes an increase in the conductivity of the electrolyte solution, but the open circuit voltage did not under undergo influence of electrolyte. From NaCl 20 wt% electrolyte, the maximum output power of the magnesium electrode materials was measured with 177mW. It is found that the power characteristics of metal-air cell could be improved by using magnesium electrode materials in the NaCl electrolyte.

Removal of Cupper(II), Zinc(II) in Marine Environment by Heavy Metal Resistant Desulfovibrio desulfuricans (중금속 내성이 있는 Desulfovibrio desulfuricans를 이용한 해양 환경에서의 Cu(II), Zn(II) 제거)

  • Joo, Jeong Ock;Kim, In Hwa;Oh, Byung-Keun
    • KSBB Journal
    • /
    • v.29 no.3
    • /
    • pp.139-144
    • /
    • 2014
  • Microorganisms play a significant role in bioremediation of heavy metal contaminated seawater. In this study, we reported an effective removal of Cu and Zn in marine envionment by using Desulfovibrio desulfuricans (D. desulfuricans) which belong to sulfate reducing bacteria. D. desulfuricans showed stable growth characteristics in high salt concentration and had resistance to heavy metals. Cu and Zn was removed not only by physical adsorption on the surface of bacteria but also by precipitation reaction of microbial metabolism by D. desulfuricans in seawater. In case of different heavy metal concentration, Cu was effectively removed 85% at 25 ppm and 60% at 50 ppm and Zn was effectively removed 54% at 50 ppm and 46% at 200 ppm, respectively.

Removal of Heavy Metals from Aqueous Solution by Fly Ash

  • Cho, Hee-Chan;Oh, Dal-Young
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.494-499
    • /
    • 2001
  • The present work investigates the possible use of fly ash for the removal of heavy metal ions from aqueous solutions. Batch experiments were conducted and the influences of metal concentration, pH, and fly ash concentration were investigated. Heavy metals used in these studies were zinc, lead and cadmium. Adsorption studies were done over a range of pH values (3-10) at $25^{\circ}C$ and heavy metal concentrations of 10-400 mg/L using fly ash concentrations of 10, 20 and 40 g/L. Experiments were also conducted without fly ash to determine the extent of heavy metal removal by precipitation. Kinetic and equilibrium experiments were performed and adsorption data were correlated with both Langmuir and Freundlich adsorption models. The results indicate that fly ash can be used as an adsorbent for heavy metals in the aqueous solutions, yet the degree of removal depends on the pH.

  • PDF

A Study on Hydrogen Detection Characteristics of the Pt-MIS Capacitor Device (Pt-MIS Capacitor 소자의 수소가스 검지특성에 관한 연구)

  • Kwon, K.H.;Yi, S.H.;Kim, Y.H;Rhie, D.H.;Sung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.333-335
    • /
    • 1997
  • This paper was performed to investigate the characteristic of the Pt-MIS(Metal Insulator Semiconductor) capacitor composed of the LPCVD nitride on the oxide for the hydrogen gas detection. Pt was used as catalytic metal for detecting the hydrogen gas and the flat band voltage shift was measured at various hydrogen concentration and catalytic metal thickness. We found the flat band voltage shift was proportional to the hydrogen concentration and catalytic metal thickness was little effect to the response time.

  • PDF

Antioxidant Effect of Onion Skin Extract (양파껍질 추출물의 항산화 및 상승효과)

  • 손종연;손흥수;조원대
    • Korean journal of food and cookery science
    • /
    • v.14 no.1
    • /
    • pp.16-20
    • /
    • 1998
  • The antioxidant and synergistic effect of methanol extracts of onion skin were investigated by measuring peroxide value. The inhibitory effects of the extracts against metal catalyzed oxidation were also studied. The antioxidant activity of methanol extract (0.02%) of onion skin was stronger than that of mixed tocopherol or ascorbic acid (0.02%), but weaker than that of BHT (0.02%). However, the methanol extract at the concentration of 0.04% exhibited strong antioxidant effect, comparable to that of BHT (0.02%). The methanol extract showed very strong synergistic effect with the mixed tocopherol. The methanol extracts at the concentration of 0.03% and 0.04% acted as metal deactivator in the presence of FeC1$_3$. As a metal deactivator, methanol extract of onion skin appeared to be more effective than citric acid.

  • PDF

A Development of a Transient Hydrogen Generation Model for Metal-Water Interactions

  • Lee, Jin-Yong;Park, Goon-Cherl;Lee, Byung-Chul
    • Nuclear Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.549-558
    • /
    • 2000
  • A transient model for hydrogen generation in molten metal-water interactions was developed with separate models for two stages of coarse mixing and stratification. The model selves the mechanistic equations (heat and mass transfer correlation, heat conduction equation and the concentration diffusion equation) of each stage with non-zero boundary conditions. Using this model, numerical simulations were performed for single droplet experiments in the Argonne National Laboratory tests and for FITS tests that simulated dynamic fragmentation and stratification. The calculation results of hydrogen generation showed better agreement to the experiment data than those of previous works. It was found from the analyses that the steam concentration to be reached at the reaction front might be the main constraint to the extent of the metal droplet oxidized. Also, the hydrogen generation rate in the coarse mixing stage was the higher than that in the stratification stage. The particle size was the most important factor in the coarse mixing stage to predict the amount of hydrogen generation.

  • PDF

Electrical Properties of IMI-O Polymeric LB Films Using logic Concentration (이온농도에 의한 IMI-O고분자 LB막의 전기특성)

  • 정상범;유승엽;박재철;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.418-420
    • /
    • 1997
  • We synthesized the polymer that can have function group and improvement of mechnical strength and then confirmed the possibility of molecular device made by LB method. In this paper, the $\pi$-A isotherm has been investigated as to the kinds and various concentrations of the metal ions complexed with imidazole group. The experimental results for the electrical properties of MIM fabricated has been obtained as following. There is no change in limiting area as to the kinds of the metal ions, also the shift of conductivity as to the metal ions couldn't be observed, which was 10$\^$-14/[S/cm]. There are some changes in limiting area as to the concentration of the metal ions, the conductivity shift was increased with the occupied molecular area.

  • PDF

Removal study of As (V), Pb (II), and Cd (II) metal ions from aqueous solution by emulsion liquid membrane

  • Dohare, Rajeev K.;Agarwal, Vishal;Choudhary, Naresh K.;Imdad, Sameer;Singh, Kailash;Agarwal, Madhu
    • Membrane and Water Treatment
    • /
    • v.13 no.4
    • /
    • pp.201-208
    • /
    • 2022
  • Emulsion Liquid Membrane (ELM) is a prominent technique for the separation of heavy metal ions from wastewater due to the fast extraction and is a single-stage operation of stripping-extraction. The selection of the components (Surfactant and Carrier) of ELM is a very significant step for its preparation. In the ELM technique, the primary water- in-oil (W/O) emulsion is emulsified in water to produce water-in-oil-in-water (W/O/W) emulsion. The water in oil emulsion was prepared by mixing the membrane phase and internal phase. To prepare the membrane phase, the extractant D2EHPA (di-2-ethylhexylphosphoric acid) was used as a mobile carrier, Span-80 as a surfactant, and Paraffin as a diluent. Moreover, the internal (receiving) phase was prepared by dissolving sulphuric acid in water. Di-(2- ethylhexyl) phosphoric acid such as surfactant concentration, carrier concentration, sulphuric acid concentration in the receiving (internal) phase, agitation time (emulsion phase and feed phase), the volume ratio of the membrane phase to the receiving phase, the volume ratio of the external feed phase to the primary water-in-oil emulsion and pH of feed were studied on the percentage extraction of metal ions at 20℃. The results show that it is possible to remove 78% for As(V), 98% for Cd(II), and 99% for Pb(II). Emulsion Liquid Membrane (ELM) is a well-known technique for separating heavy metal ions from wastewater due to the fast extraction and is a single-stage operation of stripping-extraction. The selection of ELM components (Surfactant and Carrier) is a very significant step in its preparation. In the ELM technique, the primary water-in-oil (W/O) emulsion is emulsified to produce water-in-oil-in-water (W/O/W) emulsion. The water in the oil emulsion was prepared by mixing the membrane and internal phases. The extractant D2EHPA (di-2-ethylhexylphosphoric acid) was used as a mobile carrier, Span-80 as a surfactant, and Paraffin as a diluent. Moreover, the internal (receiving) phase was prepared by dissolving sulphuric acid in water. Di-(2-ethylhexyl) phosphoric acid such as surfactant concentration, carrier concentration, sulphuric acid concentration in the receiving (internal) phase, agitation time (emulsion phase and feed phase), the volume ratio of the membrane phase to the receiving phase, the volume ratio of the external feed phase to the primary water-in-oil emulsion and pH of feed were studied on the percentage extraction of metal ions at 20℃. The results show that it is possible to remove 78% for As(V), 98% for Cd(II), and 99% for Pb(II).

Selective Removal of Toxic Heavy Metals in Fe-Coagulants (철염 응집제 중 유독성 중금속의 선택적 제거)

  • 박상원
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.393-397
    • /
    • 1999
  • Among various reactions which metal sulfides can undergo in the reducing environment, the lattice exchange reaction was examined in a attempt to selectively remove heavy metal ions contained in the Fe-Coagulants acid solution. We have examined Zeta potential along with pHs to investigate surface characteristics of ${FeS}_{(s)}$. As a result of this experiment, zero point charge(ZPC) of FeS is pH 7 and zeta potential which resulted from solid solution reaction between Pb(II) and ${FeS}_{(s)}$ is similar to that of ${PbS}_{(s)}$. Solubility characteristics of ${FeS}_{(s)}$ is appeared to that dissolved Fe(II) concentration increased in less than pH 4, and also increased with increasing heavy metal concentration. Various heavy metal ions(Pb(II), Cu(II), Zn(II)) contained in Fe-coagulants acid solution were removed selectively more than ninety-five percent in the rang of pH 2.5~10 by ${FeS}_{(s)}$. From the above experiments, therefore, We could know that the products of reaction between heavy metal ions and $FeS_{(S)}$ are mental sulfide such as $PbS_{(S)}$, $CuS_{(S)}$ and $ZnS_{(S)}$.

  • PDF

An Assessment of the Heavy Metal Contamination of Sediment in Main Stream and Tributaries of the Han River in the Vicinity of Seoul (서울시 인근의 한강 본류 및 지류에 대한 하상 저질의 중금속오염 평가)

  • 노수미;이홍근
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.4
    • /
    • pp.17-35
    • /
    • 1994
  • This study was performed to investigate and assess the heavy metal contamination of sediment in main stream and tributaries of the Han-river in the vicinity of Seoul. Sediment were sampled at eight locations of main stream and eighteen locations of tributaries in the spring, summer, and fall in 1993. Six heavy metals of Cd, Cu, Pb, Zn, Cr, and Hg, were assessed. For an assessment of heavy metal contamination in sediment, the assessment method of Hakanson was modified to estimate for Han-river, then classification method of Muller in sediment quality was applied. For an assessment of contamination in each heavy metal, Contamination factor C$_f^i$ which was defined the ratio of concentration of i heavy metal in investigated location to background concentration of i heavy metal in uncontaminated upper area was used. The sediment quality in each heavymetal was classified as follows if C$_f^i$<1, Class I for Non contamination, if 1 < C$_f^i$ < 3, Class II for Low contamination, if 3< C$_f^i$ <6, Class III for Moderate contamination, if 6< C$_f^i$ <12, Class IV for Considerable contamination, and if C$_f^i$ > 12, Class V for High contamination.(abbreviation)

  • PDF