• Title/Summary/Keyword: mesh graft

Search Result 37, Processing Time 0.026 seconds

Use of the Full-thickness Free Skin Mesh Graft for Reconstruction of Wound in a Dog (개의 피부손상에 대한 전층망상식피술 증례)

  • Kim, Joo-Ho;Lee, Jong-Il;Lee, Hae-Beom;Heo, Su-Young;So, Kyoung-Min;Ko, Jae-Jin;Chon, Seung-Ki;Lee, Cheol-Ho;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.280-283
    • /
    • 2007
  • A 6-year-old male dog was referred to Animal Medical Center, Chonbuk National University with large distal extremity abrasion wound to the hind limb by automobile accident. The wound was reconstructed with an autogenous, full-thickness skin mesh graft. The graft was harvested from the ventrolateral abdominal wall and transplanted to the wound. The skin mesh graft survived successfully without any noticeable complications. Successful grafting requires asepsis, an adequately prepared recipient bed through the surgical debridement and lavage, proper harvesting and preparation of the graft. Full-thickness skin mesh graft has lesser skin contraction which prevents formation of scar. Meshing the graft provides more graft flexibility over uneven, convex and concave surfaces and allows adequate drainage. The full-thickness skin mesh graft can be successfully used for the treatment of large distal skin wounds in dogs.

Retrospective case series analysis of vestibuloplasty with free gingival graft and titanium mesh around dental implant

  • Ku, Jeong-Kui;Leem, Dae Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.6
    • /
    • pp.417-421
    • /
    • 2020
  • Objectives: The purpose of this paper is to introduce an effective technique to easily obtain adequate amounts of keratinized gingiva and vestibular depth. Materials and Methods: Free gingiva (vertical height 10 mm) was harvested on the palatal mucosa and a partial thickness flap was elevated on the recipient site with same width as the free gingiva graft. After a conventional suture, a titanium mesh covered the graft and was fixed with miniscrews. Titanium mesh was removed 4.1±2.5 weeks after surgery. The amount of keratinized gingiva and vestibular depth was measured at the final follow-up. Results: Nine patients (males 4, females 5; 53.9±14.1 years) who underwent bone graft surgery before vestibuloplasty were included. No free gingival graft failure or complications were encountered in any of the patients. The relapse rate for vestibular depth (23.3%) was lower than that for keratinized gingiva (48.3%) after 34.4±14.4 months (P=0.010). Conclusion: Vestibuloplasty with a free gingival graft using titanium mesh could be achieved with an acceptable amount of keratinized gingiva and an appropriate vestibular depth around dental implant.

Vestibuloplasty covering titanium mesh with grafted free gingiva on anterior mandible: technical report and rationale

  • Ku, Jeong-Kui;Leem, Dae Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.6
    • /
    • pp.369-373
    • /
    • 2019
  • This paper describes a patient with an insufficient vestibular depth for a removable partial denture who underwent vestibuloplasty with a free gingival graft using a titanium mesh in the anterior mandible. Free gingiva was harvested from the palatal mucosa, and a partial thickness flap was elevated at the recipient site. After minimal suturing for the graft, a titanium mesh was fixed over the graft. The mesh was removed four weeks after surgery. The patient obtained an adequate vestibular depth and keratinized gingiva eight weeks after surgery without any complications. In this case, an appropriate vestibular depth and keratinized gingiva were easily obtained by vestibuloplasty using a titanium mesh.

Reconstruction of Mandibular Bone Defect Using a Titanium Mesh with Autogenous Particulate Cortical Bone Graft by an Intraoral Approach: A Case Report (구강내 접근으로 자가 분쇄 피질골과 Titanium Mesh를 이용한 광범위한 하악골 골결손부 재건: 증례보고)

  • Choi, Seok-Tai;Leem, Dae-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.6
    • /
    • pp.466-472
    • /
    • 2012
  • The loss of mandibular continuity due to trauma, neoplasm, or infection results in major esthetic and biologic compromise. The reconstruction of the mandibular bone defect still poses a challenge to oral and maxillofacial surgeons. There have been a number of variety graft materials. Among them, free block bone graft with rigid fixation has been widely used. However, cases using free block bone grafts may lead to a marked invasion of the donor site, mal-union, and absorption of the block bone. In this respect, particulate cortical bone using a titanium mesh tray can be an effective alternative option in order to achieve a proper bone contour and good oral rehabilitation. We have developed an intraoral approach for the mandibular reconstruction method using a titanium mesh tray with autogenous particulate cortical bone graft.

Maxillary reconstruction using tunneling flap technique with 3D custom-made titanium mesh plate and particulate cancellous bone and marrow graft: a case report

  • Takano, Masayuki;Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Homma, Shinya;Abe, Shinichi;Katakura, Akira;Shibahara, Takahiko
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.43.1-43.5
    • /
    • 2019
  • Background: Reconstructive surgery is often required for tumors of the oral and maxillofacial region, irrespective of whether they are benign or malignant, the area involved, and the tumor size. Recently, three-dimensional (3D) models are increasingly used in reconstructive surgery. However, these models have rarely been adapted for the fabrication of custom-made reconstruction materials. In this report, we present a case of maxillary reconstruction using a laboratory-engineered, custom-made mesh plate from a 3D model. Case presentation: The patient was a 56-year-old female, who had undergone maxillary resection in 2011 for intraoral squamous cell carcinoma that presented as a swelling of the anterior maxillary gingiva. Five years later, there was no recurrence of the malignant tumor and a maxillary reconstruction was planned. Computed tomography (CT) revealed a large bony defect in the dental-alveolar area of the anterior maxilla. Using the CT data, a 3D model of the maxilla was prepared, and the site of reconstruction determined. A custom-made mesh plate was fabricated using the 3D model (Okada Medical Supply, Tokyo, Japan). We performed the reconstruction using the custom-made titanium mesh plate and the particulate cancellous bone and marrow graft from her iliac bone. We employed the tunneling flap technique without alveolar crest incision, to prevent surgical wound dehiscence, mesh exposure, and alveolar bone loss. Ten months later, three dental implants were inserted in the graft. Before the final crown setting, we performed a gingivoplasty with palate mucosal graft. The patient has expressed total satisfaction with both the functional and esthetic outcomes of the procedure. Conclusion: We have successfully performed a maxillary and dental reconstruction using a custom-made, pre-bent titanium mesh plate.

Esophageal Fistula Related to Anterior Cervical Spine Surgery after Severe Cervical Trauma (심한 경추부 외상후에 전방 경추부 수술후 발생한 식도의 누공)

  • Paeng, Sung Hwa
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.278-282
    • /
    • 2012
  • An esophageal perforation following anterior cervical fusion is rare. Early development of an esophageal perforation after anterior cervical fusion is usually due to iatrogenic injury from retraction, injury associated with the original traumatic incident, improperly placed instruments or a bone graft. A 31-year-old man had a cervical dislocation and spinal cord injury because of severe cervical trauma after a traffic accident. He was quadriplegic and had no feeling below T4 dermatome. Anterior decompression of the cervical spine and anterior fusion with mesh with autobone were performed. An esophagocutaneous fistula occurred 7 days after anterior cervical surgery. A second anterior surgery was done because of pus drainage. The mesh was changed with an iliac bone graft, and the esophagocutaneous fistula site was primary repaired, but pus continued to drain. Conservative treatment, which consisted of wound drainage and intravenous administration of antibiotics, was tried, but was unsuccessful. After all, we removed the plate and screws, but did not removed the iliac bone graft, We closed the esophageal fistula, and transposed the sternocleidomastoid muscle flap to the interspace between the esophagus and the cervical spine. The wound to the esophagus was well repaired. In conclusion, precautionary measures are needed to avoid the complication, and adequate treatment is necessary to resolve those complications when they occur.

Reconstruction of Triceps Tendon Avulsion Using Mesh Graft and Krackow Suture in a Border Collie

  • Hyeon-Jong Choi;Jong-Hoon Kim;Eunchae Yoon;Tae-Sung Hwang;Hee-Chun Lee;Dongbin Lee;Jae-Hoon Lee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.378-383
    • /
    • 2022
  • A 3-year-old, 24-kg intact female Border Collie was referred for a toe-touch weight-bearing stance, intermittent weight-bearing lameness, and moderate pain reaction of the right forelimb on physical examination and right humerus olecranon avulsion fracture on diagnostic imaging examination. Surgical repair was performed using tension band wiring to re-attach the triceps tendon and distal olecranon. Migration of the distal olecranon fragment was observed due to comminuted fracture of the fragment 5-days after surgery, and revision surgery was performed. The tension-relieving sutures were passed through the pre-drilled hole in the olecranon, and the polyester mesh was augmented to the suture region, covering the triceps tendon and olecranon drilling hole using the Krackow suture pattern. The elbow joint was immobilized using a type IA transarticular external fixator, which was removed 8 weeks after surgery. Fourteen weeks after surgery, no lameness was observed on gait evaluation. At follow-up after 7 months, the distal olecranon fragment had stabilized, and no lameness was observed.

Mandibular reconstruction with a ready-made type and a custom-made type titanium mesh after mandibular resection in patients with oral cancer

  • Lee, Won-bum;Choi, Won-hyuk;Lee, Hyeong-geun;Choi, Na-rae;Hwang, Dae-seok;Kim, Uk-kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.35.1-35.7
    • /
    • 2018
  • Background: After the resection at the mandibular site involving oral cancer, free vascularized fibular graft, a type of vascularized autograft, is often used for the mandibular reconstruction. Titanium mesh (T-mesh) and particulate cancellous bone and marrow (PCBM), however, a type of non-vascularized autograft, can also be used for the reconstruction. With the T-mesh applied even in the chin and angle areas, an aesthetic contour with adequate strength and stable fixation can be achieved, and the pores of the mesh will allow the rapid revascularization of the bone graft site. Especially, this technique does not require microvascular training; as such, the surgery time can be shortened. This advantage allows older patients to undergo the reconstructive surgery. Case presentation: Reported in this article are two cases of mandibular reconstruction using the ready-made type and custom-made type T-mesh, respectively, after mandibular resection. We had operated double blind peer-review process. A 79-year-old female patient visited the authors' clinic with gingival swelling and pain on the left mandibular region. After wide excision and segmental mandibulectomy, a pectoralis major myocutaneous flap was used to cover the intraoral defect. Fourteen months postoperatively, reconstruction using a ready-made type T-mesh (Striker-Leibinger, Freibrug, Germany) and iliac PCBM was done to repair the mandible left body defect. Another 62-year-old female patient visited the authors' clinic with pain on the right mandibular region. After wide excision and segmental mandibulectomy on the mandibular squamous cell carcinoma (SCC), reconstruction was done with a reconstruction plate and a right fibula free flap. Sixteen months postoperatively, reconstruction using a custom-made type T-mesh and iliac PCBM was done to repair the mandibular defect after the failure of the fibula free flap. The CAD-CAM T-mesh was made prior to the operation. Conclusions: In both cases, sufficient new-bone formation was observed in terms of volume and strength. In the CAD-CAM custom-made type T-mesh case, especially, it was much easier to fix screws onto the adjacent mandible, and after the removal of the mesh, the appearance of both patients improved, and the neo-mandibular body showed adequate bony volume for implant or prosthetic restoration.

THE RECONSTRUCTION OF THE MAXILLARY WALL DEFECT USING MICRO-TITANIUM MESH (Micro-titanium mesh를 이용한 상악골 결손부의 재건술에 관한 연구)

  • Kim, Seong-Gon;Choi, You-Sung;Choung, Pill-Hoon;Lee, Hee-Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.2
    • /
    • pp.197-203
    • /
    • 2000
  • Maxillary defect may be induced by trauma, inflammation, cyst, tumor and surgical procedure. In case of limited wall defect, free bone graft has been preferred. But it has some problems such as postoperative bone resorption and soft tissue inclusion to recipient site. And we can not use free bone in the case who has inflammation in the donor site. So we used the micro-titanium mesh as reconstructive material for the maxillary wall defect. We had operated 8 patients who were diagnosed as maxillary partial defects from June 1997 to September 1998 in the Chin-Hae military hospital. They were 1 case of antral wall defect, 1 case of palatal wall defect, 5 cases of infra-orbital wall defects and 1 case of oroantral fistula case. As a result, the micro-titanium mesh has shown the morphological stability and biocompatibility and it could be used in case who has infection. And mesh structure could prevent soft tissue ingrowth to bony defect area. Thus it can be used to the case of maxillary partial defect successfully.

  • PDF

A Case of Traumatic Ventral Hernia Repair with a Porcine Dermal Collagen Graft (Permacol) (외상성 복벽 탈장 환자에서 biologic mesh를 이용한 치료)

  • Yu, Byung Chul;Chung, Min
    • Journal of Trauma and Injury
    • /
    • v.25 no.2
    • /
    • pp.63-66
    • /
    • 2012
  • Resection of the bowel is necessary for the repair of a ventral hernia after recovery from trauma in some cases. In such instances, polyester or polypropylene meshcannot be used due to the possibility of infection; we had to use biological mesh instead. We report a case in which a traumatic hernia was repaired with Permacol (Covidien, Norwalk, CT, USA). A 42-year-old male patient had been injured by a factory machine seven months prior to admission. At that time, he had abdominal wall injury and small bowel perforation. His abdominal wall had been a defect after operation. A CT scan of the abdomen showed that the left abdominal wall, which is lateral to left rectus abdominis muscle had only one muscle layer, an external oblique muscle, and that a previous abdominal incision had a defect along the entire incision. During the exploration, 10 cm of small bowel was removed due to firm adhesion to the previous surgical scar. Permacol mesh was applied and fixed with transfascial fixations and tacks by using the intraperitoneal onlay mesh technique. There were no complications after the surgery and the patient was discharged without any problems.