DOI QR코드

DOI QR Code

Retrospective case series analysis of vestibuloplasty with free gingival graft and titanium mesh around dental implant

  • Ku, Jeong-Kui (Department of Oral and Maxillofacial Surgery, School of Dentistry and Institute of Oral Bioscience, Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Jeonbuk National University) ;
  • Leem, Dae Ho (Department of Oral and Maxillofacial Surgery, School of Dentistry and Institute of Oral Bioscience, Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Jeonbuk National University)
  • Received : 2020.02.03
  • Accepted : 2020.03.13
  • Published : 2020.12.31

Abstract

Objectives: The purpose of this paper is to introduce an effective technique to easily obtain adequate amounts of keratinized gingiva and vestibular depth. Materials and Methods: Free gingiva (vertical height 10 mm) was harvested on the palatal mucosa and a partial thickness flap was elevated on the recipient site with same width as the free gingiva graft. After a conventional suture, a titanium mesh covered the graft and was fixed with miniscrews. Titanium mesh was removed 4.1±2.5 weeks after surgery. The amount of keratinized gingiva and vestibular depth was measured at the final follow-up. Results: Nine patients (males 4, females 5; 53.9±14.1 years) who underwent bone graft surgery before vestibuloplasty were included. No free gingival graft failure or complications were encountered in any of the patients. The relapse rate for vestibular depth (23.3%) was lower than that for keratinized gingiva (48.3%) after 34.4±14.4 months (P=0.010). Conclusion: Vestibuloplasty with a free gingival graft using titanium mesh could be achieved with an acceptable amount of keratinized gingiva and an appropriate vestibular depth around dental implant.

Keywords

References

  1. Schwartz-Arad D, Chaushu G. Placement of implants into fresh extraction sites: 4 to 7 years retrospective evaluation of 95 immediate implants. J Periodontol 1997;68:1110-6. https://doi.org/10.1902/jop.1997.68.11.1110
  2. Halperin-Sternfeld M, Zigdon-Giladi H, Machtei EE. The association between shallow vestibular depth and peri-implant parameters: a retrospective 6 years longitudinal study. J Clin Periodontol 2016;43:305-10. https://doi.org/10.1111/jcpe.12504
  3. Schmitt CM, Tudor C, Kiener K, Wehrhan F, Schmitt J, Eitner S, et al. Vestibuloplasty: porcine collagen matrix versus free gingival graft: a clinical and histologic study. J Periodontol 2013;84:914-23. https://doi.org/10.1902/jop.2012.120084
  4. Bohannan HM. Studies in the alteration of vestibular depth I. Complete denudation. J Periodontol 1962;33:120-8. https://doi.org/10.1902/jop.1962.33.2.120
  5. Wang RR, Fenton A. Titanium for prosthodontic applications: a review of the literature. Quintessence Int 1996;27:401-8.
  6. Ku JK, Leem DH. Vestibuloplasty covering titanium mesh with grafted free gingiva on anterior mandible: technical report and rationale. J Korean Assoc Oral Maxillofac Surg 2019;45:369-73. https://doi.org/10.5125/jkaoms.2019.45.6.369
  7. Egli U, Vollmer WH, Rateitschak KH. Follow-up studies of free gingival grafts. J Clin Periodontol 1975;2:98-104. https://doi.org/10.1111/j.1600-051x.1975.tb01730.x
  8. Lim HC, An SC, Lee DW. A retrospective comparison of three modalities for vestibuloplasty in the posterior mandible: apically positioned flap only vs. free gingival graft vs. collagen matrix. Clin Oral Investig 2018;22:2121-8. https://doi.org/10.1007/s00784-017-2320-y
  9. Thoma DS, Benic GI, Zwahlen M, Hammerle CH, Jung RE. A systematic review assessing soft tissue augmentation techniques. Clin Oral Implants Res 2009;20 Suppl 4:146-65. https://doi.org/10.1111/j.1600-0501.2009.01784.x
  10. Elkhaweldi A, Rincon Soler C, Cayarga R, Suzuki T, Kaufman Z. Various techniques to increase keratinized tissue for implant supported overdentures: retrospective case series. Int J Dent 2015;2015:104903. https://doi.org/10.1155/2015/104903

Cited by

  1. The Vestibuloplasty Using Non-eugenol-based Non-zinc Oxide Oral Dressing Material vol.14, pp.1, 2020, https://doi.org/10.5856/jkds.2021.14.1.46