• Title/Summary/Keyword: membrane system

Search Result 2,409, Processing Time 0.028 seconds

Application of $ENVIS^{(R)}$ MEMBRANE SYSTEM (Sumerged flat Sheet MF Membrane) ($ENVIS^{(R)}$ MEMBRANE SYSTEM (평판형 정밀여과막)의 침지식 수처리 공정 적용에 관한 연구)

  • Lee, Young-Moo;Jang, Jae-Young
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.241-246
    • /
    • 2005
  • This study is investigated for the applications of MBR SYSTEM using $ENVIS^{(R)}$ which is a submerged flat membrane for treatment of sewage and wast water. The experiment was practiced on the scene of labor that are sewage facilities of factories $(10\;m^3/day)$ and wast water treatment plant $(30\;m^3/day)$ using equipments made by Pure-Envitech Co., LTD. SS, BOD and COD for the result of removal efficiency at the sewage facilities of factories were $99.7\%,\;97.6\%$, and $96.8\%$, rspectively. SS, BOD and COD for the result of removal efficiency at the waste water treatment plant were $99.6\%,\;95.6\%,\;and\;80.3\%$, respectively.

Recovery of Dissolved Volatile Fatty Acids from Liquid Sludge using Anaerobic Membrane-fermenter System (혐기성 분리막을 이용한 액상 슬러지로부터의 용해성 저급 지방산의 회수)

  • Kim, Jong-Oh;Kim, Seog-Ku;Kim, Ree-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.2
    • /
    • pp.183-189
    • /
    • 2004
  • The performance of a membrane-coupled anaerobic fermenter system for the recovery of volatile fatty acids (VFAs) from liquid organic sludge was experimentally investigated. Permeation flux was stably kept around $0.2(m^3/m^2/day)$ during operational period. The membrane-coupled fermenter showed 2.2 times higher VFAs concentration and higher VFAs forming rate than those of fermenter without membrane. The fermenter with membrane proved to be an effective system for the recovery of soluble organic materials from liquid sludge.

Production of Bacteriorhodopsin by Halobacterium halobium in the Internal Membrane Bioreactor (내부 필터 발효기에서 Halobacterium halobium의 배양에 의한 박테리오로돕신의 생산)

  • 엄영순;박준택;홍순호;이상엽;장호남
    • KSBB Journal
    • /
    • v.13 no.3
    • /
    • pp.268-271
    • /
    • 1998
  • Bacteriorhodopsin in the purple membrane (PM) of halobacteria has recently been attracting much attention to be used as a component of molecular electron device and optical computers. In order to increase the productivity of bacteriorhodopsin in high cell density cultures of Halobacterium halobium R1, an internal membrane cell-retention bioreactor system was employed. As a result, the production of cell mass at OD660 of 12 and of bacteriorhodopsin at 125-130 mg/L were obtained using the internal membrane bioreactor system at a dilution rate of 0.066 hr-1. The productivity achieved by the internal membrane system (0.7 mg/L$.$hr) was 3.5-fold higher than that obtained by the corresponding batch cultivations (0.2 mg/L$.$hr).

  • PDF

Development of Deburring System for Aircraft Components (Membrane 제거를 위한 전용 시스템 개발)

  • 최운집;정원재;성승학;이득우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1070-1073
    • /
    • 2004
  • This paper is on the development of a system for removing membranes which is designed exclusively for aircraft components. Membrane removal solution is a most critical issue in aerospace industries since a method of manufacturing the components tends to be changed from fabrication of many parts to cutting into one body. The cutting method inevitably produces a huge amount of chips and then membranes remain in the body. The membrane removal process, as a result, becomes an important issue since it is directly related to productivity. We tried to develop a new machine which will replace the conventional method that uses a handy tool. The machine has been designed for a cutting tool set to follow the unique shape of the slot in the body by a cam follower and cut the membrane automatically. The design has been checked by structural analysis: stress and vibration analysis. A prototype test has been finished. This paper summarizes a series of development process of the deburring machine and some design issues are discussed.

  • PDF

Watertightness Property Evaluation of Rain-Block System (개폐식 대공간 구조물에서 지붕 맞댐부 우수차단 시스템의 수밀성 평가에 관한 연구)

  • Kim, Yun-Ho;Baek, Ki-Youl;Kim, Jong-Su;Lee, Sun-Gyu;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.13-16
    • /
    • 2010
  • This study is an Investigation on the Watertightness Properties of Rain-Block System on the Sliding-Roof Joint of Large-Span Membrane Structures. In this experimental, we test the watertightness performance of joint part of sliding door in roof of large span membrane structure(for pilot project) under environment of rain and wind. A shape of rain water blocking systems of joint part in sliding door verifies the defects and effects of water leakage prevention in precipitation with the wind conditions. For obtaining watertightness of large span membrane structures, it is necessary quality of joints and performance, and quality of membrane material of a retractable roof as well as a closed roof. Also, for obtaining quality in joints, it is essential to make a watertightness guideline for design of large-span membrane.

  • PDF

Graphene Oxide (GO) Layered Structure Ion Exchange Membrane Application for Vanadium Redox Flow Battery (VRB) System Study (산화그라핀 (Graphene Oxide, GO)이 코팅된 양이온 교환막을 용한 바나듐 레독스 흐름 전지 (Vanadium Redox Flow attery, VRB) 시스템에 관한 연구)

  • Lee, Kwan Ju;Chu, Young Hwan
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.2
    • /
    • pp.94-102
    • /
    • 2014
  • Cation exchange membrane (Nafion) was modified to reduce the vanadium ion permeation through the membrane and to increase the vanadium redox flow battery (VRB) system performance by coating the graphene oxide (GO) which has nano-plate like morphology. Modified membrane properties were studied by measuring the ion exchange capacity (I.E.C), water uptake and proton conductivity. The thickness of the coated layer on the surface of the Nafion membrane was observed as $0.93{\mu}m$ by SEM. Proton conductivity and vanadium ion permeability of the modified membrane were decreased to 27% and 25% compared to that of the commercial Nafion membrane respectively. VRB single cell performance test was performed to compare the system performance of the VRB applied with commercial Nafion membrane and modified membrane. VRB system applied with modified membrane showed higher coulombic efficiency and energy efficiency than the VRB system applied with the commercial Nafion membrane due to the reduction of the vanadium ion permeation. From these result, we could suggest that the membrane modification by coating the GO on the surface of the Nafion membrane could be one of the promising strategies to reduce the vanadium ion permeation and to increase the VRB system performance effectively.

Determination of operating factor and characteristics of membrane fouling on hybrid coagulation pretreatment-UF system in drinking water treatment (정수처리 응집·한외여과 시스템의 연속운전을 통한 운전조건 결정 및 막오염 특성에 관한 연구)

  • Moon, Seong-Yong;Yun, Jong-Sub;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.267-274
    • /
    • 2008
  • This study is about efficiency of pretreatment process and operating factor to membrane process at continuous coagulation/ultrafiltration process in water treatment. The capacity of pilot plant was $0.06{\beta}(C)/d$. The raw water used was from Nakdong stream which was characteristized by high organic matter and high turbidity. The result of the test was that coagulation is good process as to high removal rate to organic matter and turbidity but It caused problem to membrane pore blocking. This paper is to determine the membrane fouling potential under different membrane flux, backwash pressure and linear velocity. Backwash pressure and flux is important parameter on operation of membrane system. Those are directly affected on membrane system. When backwash pressure increased from 150 kPa to 200 kPa, the result showed that fouling (pressure increase rate) changed from 3.69 kPa/h to 0.93 kPa/h and the recovery rate changed from 90.7 % to 82.0 %. Linear velocity had slightly effect on fouling. Linear velocity increased from 0.2 m/s to 0.5 m/s, the corresponding pressure rate changed from 0.93 kPa/d to 0.77 kPa/d.