Determination of operating factor and characteristics of membrane fouling on hybrid coagulation pretreatment-UF system in drinking water treatment

정수처리 응집·한외여과 시스템의 연속운전을 통한 운전조건 결정 및 막오염 특성에 관한 연구

  • 문성용 (엔바로테크(주) 나노응용연구소) ;
  • 윤종섭 (경남대학교 토목공학과) ;
  • 김승현 (경남대학교 토목공학과)
  • Received : 2008.02.11
  • Accepted : 2008.04.11
  • Published : 2008.04.15

Abstract

This study is about efficiency of pretreatment process and operating factor to membrane process at continuous coagulation/ultrafiltration process in water treatment. The capacity of pilot plant was $0.06{\beta}(C)/d$. The raw water used was from Nakdong stream which was characteristized by high organic matter and high turbidity. The result of the test was that coagulation is good process as to high removal rate to organic matter and turbidity but It caused problem to membrane pore blocking. This paper is to determine the membrane fouling potential under different membrane flux, backwash pressure and linear velocity. Backwash pressure and flux is important parameter on operation of membrane system. Those are directly affected on membrane system. When backwash pressure increased from 150 kPa to 200 kPa, the result showed that fouling (pressure increase rate) changed from 3.69 kPa/h to 0.93 kPa/h and the recovery rate changed from 90.7 % to 82.0 %. Linear velocity had slightly effect on fouling. Linear velocity increased from 0.2 m/s to 0.5 m/s, the corresponding pressure rate changed from 0.93 kPa/d to 0.77 kPa/d.

Keywords

References

  1. 권은미.유명진(2000) UF를 이용한 용존성 유기물질 제거시 운전조건이 파울링에 미치는 영향, 대한환경공학회지, 22(7), pp. 1183-1191
  2. 문성용.김승현(2002) 응집공정에 의한 자연유기물 제거 특성에 관한 연구, 수처리기술, 10(2), pp. 57-67
  3. APHA, AWWA, WPCF(1998) Standard Methods for the Examination of Water and Wastewater. 20th ed, Washington DC, USA
  4. AWWA, (1999) Water Quality & Treatment. 15th ed, McGraw-Hill
  5. Belfort, G., Davis, R.H. and Zydney, A.L. (1994), The Behavior of Suspension s and Macromelecular Solutions in Crossflow Microfiltration, Journal of Membrane Science, 96(1), pp. 1-58 https://doi.org/10.1016/0376-7388(94)00119-7
  6. Botes, J.P. and Jacobs, S.M., (1998) Long-term evaluation of UF pilot plant for potable water production, Desalination, 115, pp 229-238 https://doi.org/10.1016/S0011-9164(98)00042-3
  7. Chen, J.P., Kim, S.L. and Ting, Y.P. (2003) Optimization of Membrane Physical and Chemical Cleaning by a Statistically Designed Approach, Journal of membrane science, 219, pp. 27-45 https://doi.org/10.1016/S0376-7388(03)00174-1
  8. Fu, P., Ruiz, H., Lozier, J., Thompson, K. and Spangenberg, C. (1995) A Pilot study on groundwater natural organics removal by low-pressure membranes, Desalination, 102, pp. 47-56 https://doi.org/10.1016/S0011-9164(00)80246-5
  9. Jaeweon Cho, Amy, G. and Pellegrino, J. (2000) Membrane filtration of Natural organic matter: factors and mechanisms affecting rejection and flux decline with charged ultrafiltration(UF) membrane, Journal of Membrane Science, 164, pp 89-110 https://doi.org/10.1016/S0376-7388(99)00176-3
  10. Lipp, p., Baldauf, G., Schick, R., Elsenhans, K. and Stabel, H.H. (1998) Integration of ultrafiltration to conventional drinking water treatment for a better particle removal -efficiency and costs, Desalination, 119, pp. 133-142 https://doi.org/10.1016/S0011-9164(98)00133-7
  11. Lipp, P. and Baldauf, G. (2002) Application of out-in MF/UF-systems for drinking water treatment with air supported backwash-three case studies, Desalination, 147, pp. 63-68 https://doi.org/10.1016/S0011-9164(02)00577-5
  12. Mallevialle, J., Odendaal, P.E. and Wiesner, M.R., (1996) Water Treatment Membrane Processes, McGraw-Hill
  13. Mori, Y., Oota, T., Hashimoto, M., Takamura, M. and Fujii, Y. (1998) Ozone-microfiltration system, Desalination, 177, pp. 211-218
  14. Mulder, M.(1996) Basic Principles of Membrane Technology, KLUWER ACAD- EMIC PUBLISHERS
  15. Porter, M.C., (1988) Handbook of industrial membrane technology, NOYES PUBLICATIO -NS
  16. Teodosiu, C.C., Kennedy, M.D., Van Straten, H. A. and Schippers, J. C. (1999) Evaluation of Secondary Refinery Effluent Treatment Using Ultrafiltration Membrabe, Water Research, 33(9), pp. 2172-2180 https://doi.org/10.1016/S0043-1354(98)00433-3