• Title/Summary/Keyword: membrane system

Search Result 2,413, Processing Time 0.028 seconds

HOLLOW FIBER MEMBRANG을 이용한 역세형 M/F SYSTEM

  • 김건태;최광호;김재협;최기석
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.10a
    • /
    • pp.74-75
    • /
    • 1994
  • 부유물질을 함유한 용수$\cdot$폐수의 정밀여과시 FOULING 때문에 세정약품이 많이 들고 MEMRANE 수명이 단축되는 문제점을 해결하기 위해 HOLLOW FIBER TYPE MEMBRANE을 이용한 역세형정밀 여과시스템을 개발하여 TEST를 실시하고 역세조건에 따른 FLUX, 제거율 및 역세효율을 조사하였다.

  • PDF

Characterization of Membrane Fouling and It's Optimal Chemical Cleaning Method in MF Process using D dam water (D댐수를 이용한 정밀여과 공정에서 막오염 특성 및 최적 화학세정방법 조사)

  • Kim, Chung H.;Lim, Jae L.;Lee, Byung G.;Chae, Seon H.;Park, Min G.;Park, Sang H.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.559-569
    • /
    • 2007
  • The purposes of this study were to find the main foulant of membrane and the optimal chemical cleaning method for MF(microfiltration) drinking water treatment system using D dam water as water source. The MF pilot plant which can treat maximum $500m^3/d$ consisted of 3 racks and was operated for 10 months under various operation conditions. After 10 months operation, $1^{st}$ and $2^{nd}$ rack of membrane pilot plant system were cleaned chemically and the degree of the restoration of the fouled membrane in terms of the pure water flux was detemnined. Inorganic compounds which contained in chemical cleaning waste was analyzed by Inductively Coupled Plasma (ICP). One membrane module for 3rd rack was disjointed and membrane fouling materials, especially inorganic compounds were investigated by Electron Probe Microanlysis (EPMA) to elucidate the reason of TMP increase. And also, the various chemical reagents (1N HCl or $H_2SO_4$, oxalic acid as acid and 0.3% NaOCl as alkali) were tested by combination of acid and alkali to determine the optimal chemical cleaning method for the MF system using micro-modules manufactured using the disjointed module. It was verified that the inside and outside of membrane module was colorized with black. As a result of the quantitative and semi-qualitative analysis of membrane foulant by ICP, most of inorganic foulant was manganese which is hard to remove by inorganic acid such as HCI. Especially, it was observed by EPMA that Mn was attached more seriously in inside surface of membrane than in outside surface of that. It was supposed that Mn fouling in inside surface of membrane might be caused by the oxidation of soluble manganese (Mn(II)) to insoluble manganese ($MnO_2$) by chlorine containing in backwashing water. The optimal cleaning method for the removal of manganese fouling was consecutive cleaning with the mixture of 1N HCl and 1% of oxalic acid, 0.3% NaOCl, and 1N HCl showing 91% of the restoration of the fouled membrane.

Filtration Characteristics of Membrane-coupled Fermentor System for Dissolved Organics Recovery From Liquid Organic Sludge (액상유기성슬러지로부터 용존유기물의 회수를 위한 막결합형 발효 시스템의 여과 특성)

  • Jong Oh Kim
    • Membrane Journal
    • /
    • v.13 no.2
    • /
    • pp.65-72
    • /
    • 2003
  • This study was focused on the investigation of filtration characteristics of membrane-coupled fermentor system for dissolved organics recovery from liquid organic sludge. On the filterability of MF over the range of $0.1{\sim}5 {\mu}m,$ the magnitude of total membrane resistance ($R_t$) is ranged as follows in the order; $0.1 {\mu}m>0.2{\mu}m>0.5 >1{\mu}m>2{\mu}m>5{\mu}m$. The cake layer resistance ($R_c$) occupied about 68~88% of total resistance with fermented sludge. Permeation flux decline was mainly attributed to the $R_c$, which was formed by a strong deposition from physico-chemical interactions of solids on membrane surface. Higher suspended solids (SS) concentration of suspension caused lower permeation flux. However, there was not a proportion relation beyond a certain SS concentration. The cross-flow velocity on the membrane surface was faster, which resulted in the higher permeation flux and also more efficient with low trans membrane pressure (TMP) in viewpoint of energy efficiency. The appropriate pH of suspension was over the range of 5.0~6.0 for dissolved organics recovery as well as the permeation flux. It is possible f3r bacteria to be separated perfectly with $0.1{\mu}m\; and \;0.2{\mu}m$ membrane pore size. Based on experimental results, most appropriate membrane pore size for the recovery is believed to around $1{\mu}m$.

Pilot-Scale Simulation of Desalination Process Using Water Integrated Forward Osmosis System (물통합형 정삼투 시스템을 이용한 파일럿 스케일 담수 공정 모사)

  • Kim, Bongchul;Hong, Seungkwan;Choi, Juneseok
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.403-408
    • /
    • 2017
  • In these days, wastewater reclamation and seawater desalination play essential role in addressing the challenge of worldwide water scarcity. Particularly, reverse osmosis (RO) for seawater desalination process is commonly used due to less energy consumption than conventional thermodynamic systems. However, membrane fouling and electrical energy consumption during operation of RO system for seawater desalination haver continued to be a obstruction to its application. In this study, therefore, wastewater secondary effluent is used for osmotic dilution of seawater. Firstly, fouling behaviour of RO by simulating wastewater effluent in osmotic dilution process was measured and we calculated energy consumption of overall desalination process by theoretical equations and commercial program. Our results reveal that RO membrane fouling can be efficiently controlled by pre-treatment systems such as nano filtration (NF) or forward osmosis (FO) process. Especially FO system for osmotic dilution process is a non-pressurized membrane system and, therefore, the operating energy consumption of overall desalination system was the lowest. Moreover, fouling layer on FO membrane is comparatively weak and reversible enough to be disrupted by physical cleaning. Thus, RO system with low salinity feed water through FO process is possible as a less energy consuming desalination system with efficient membrane fouling control.

Comparition of Submerged / Pressurized Type Membrane System by DRF and Long-Term Results in MF Drinking Water Treatment (MF막여과 정수처리에서 장기운전 결과 및 DRF를 이용한 침지식 / 가압식 시스템의 비교 평가)

  • Ha, Keum Ryul;Kim, Kwan Yeop;Kim, Hyo-Sang;Lee, Yong Soo;Song, June Sup;Kim, Chung Hwan;Yeom, Ick Tae;Lee, Yong Hoon;Kim, Hyung Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.79-86
    • /
    • 2008
  • In Korea, most of the drinking water treatment relied upon the availability of the surface water, of which the raw water quality varied significantly by season and location. Therefore, the comparison of two operation modes (Pressurized type and Submerged type membrane system) must be estimated before the long-term establishment of two systems. In this study, two pilot-scale microfiltration systems with the capacity of $50m^3/day$ were installed and operated in two different modes, and the applicability of the system was determined based on the results such as the TMP (Trans-Membrane Pressure) and flux. For quantitatively comparing the two systems, a new concept, DRF (Differential Resistance Fraction) was introduced. The accumulated sum of the permeate after each cycle of chemical cleaning was also used as a tool for the system comparison.

A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System (인공지반녹화용 멤브레인 방수 및 방근재료의 방근성능 평가 방법 제안 연구)

  • Lee, Jung-Hoon;Seon, Yun-Suk;Kwak, Kyu Sung;Oh, Sang-Keu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.141-148
    • /
    • 2009
  • The purpose of this paper is to propose a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. Green roof system is considered to be an important subject in construction industry for green growth project. At the same time, we have to consider the counterplan for protection the damage of waterproofing layer and concrete substrate from the penetration of plant root. But many kinds of materials for protection from root penetration are using in construction field. But the performance of those materials is not clear, and there is not test methods for the evaluation of performance. So in this paper, based on the research results of 4 institutes during four years and foreign cases, we made a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. This test method deals with about environmental condition of laboratory, experimental facilities, kinds of plant, specimen of test, management methods, evaluation duration and documents, etc.

  • PDF

The BNR-MBR(Biological Nutrient Removal-Membrane Bioreactor) for nutrient removal from high-rise building in hot climate region

  • Ratanatamskul, C.;Glingeysorn, N.;Yamamoto, K.
    • Membrane and Water Treatment
    • /
    • v.3 no.2
    • /
    • pp.133-140
    • /
    • 2012
  • The overall performance of BNR-MBR, so-called Anoxic-Anaerobic-Aerobic Membrane Bioreactor ($A^3$-MBR), developed for nutrient removal was studied to determine the efficiencies and mechanisms under different solid retention time (SRT). The reactor was fed by synthetic high-rise building wastewater with a COD:N:P ratio of 100:10:2.5. The results showed that TKN, TN and phosphorus removal by the system was higher than 95%, 93% and 80%, respectively. Nitrogen removal in the system was related to the simultaneous nitrification-denitrification (SND) reaction which removed all nitrogen forms in aerobic condition. SND reaction in the system occurred because of the large floc size formation. Phosphorus removal in the system related to the high phosphorus content in bacterial cells and the little effects of nitrate nitrogen on phosphorus release in the anaerobic condition. Therefore, high quality of treated effluent could be achieved with the $A^3$-MBR system for various water reuse purposes.

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.

Feasibility of Pyrophyllite Ceramic Membrane for Wastewater Treatment and Membrane Fouling (국내산 납석기반 세라믹 멤브레인 수처리 적용 가능성 평가 및 파울링 현상관찰)

  • Park, Eunyoung;Jang, Hoseok;Choi, Nakcheol;Lee, Sungjae;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.26 no.3
    • /
    • pp.205-211
    • /
    • 2016
  • Performance of pyrophyllite-based ceramic membranes newly developed were investigated. Membrane fouling caused by microbial suspensions taken from a full-scaled MBR system at domestic wastewater treatment plant was observed at different airflow rate and distance between each membrane. For the pyrophyllite support, pore size was about $1.0{\mu}m$, but surface coating with $Al_2O_3$ solution decreased the pore size with the reduction of the pure water permeability. With the MLSS taken from the full-scaled MBR system (6 g/L), the fouling rate was decreased by increasing airflow rate under $20L/m^2{\cdot}hr$ of setpoint flux. However, the effectiveness of the airflow rate on the fouling control depends strongly upon the gap between each membrane. At fixed airflow rate, the fouling rate was decreased by increasing the gap between each pyrophyllite membrane. Nevertheless, further increasing the membrane distance from 3.5 to 5.4 cm resulted in higher fouling rate. Similar result was observed with the $Al_2O_3$ coated-pyrophyllite membrane. Nevertheless, the fouling rate was lower with the coated membrane than that observed with the uncoated pyrophyllite support. Regardless of surface coating, the suspended solids were removed almost completely and the surface coating on the pyrophyllite support improved organic rejection with PEG solution (MW : 8000 kDa) tested.

The Relationship Between the Permeation Rate and the Solubility Parameter for Polyethylene-n-Hexane-Benzene System in Pervaporation (폴리에틸렌-n-헥산-벤젠계에 대한 투과속도와 용해도 파라메타 사이의 관계)

  • Rhim, Ji-Won
    • Membrane Journal
    • /
    • v.3 no.3
    • /
    • pp.136-139
    • /
    • 1993
  • It is well known that the membrane permeation in pervaporation is governed by both the chemical nature of the membrane material and the physical structure of the membrane and also the separation can be achieved by differences in either solubility, size or shape. The solubility of the penerrant in the polymeric membrane can be described qualitively by applying the Hildebrand relation [1] which relates the energy of mixing of the penerrant and the polymer material. Froehling et al. have tried to predict the swelling behavior of polymers for the systems of polyvinylchloride(PVC)-toluene-methanol, PVC-trichloroethylene-nitromethane and PVC-n-butylacetate-nitromethane[2]. The former two systems which do not show the donor/acceptor interactions upon mixing showed the successful results[2]. In addition to this technique, there are several other possible approaches to predict the swelling behaviors of polymers, such as the surface thermodynamic approach[3, 4], the comparison of the membrane polarity with the solvent polarity in terms of Dimroth's solvent polarity value[5].

  • PDF