• Title/Summary/Keyword: membrane material

Search Result 1,085, Processing Time 0.026 seconds

Thermoelastic Behaviors of Fabric Membrane Structures

  • Roh, Jin-Ho;Lee, Han-Geol;Lee, In
    • Advanced Composite Materials
    • /
    • v.17 no.4
    • /
    • pp.319-332
    • /
    • 2008
  • The thermoelastic behaviors of an inflatable fabric membrane structure for use in a stratospheric airship envelope are experimentally and numerically investigated. Mechanical tensile properties of the membrane material at room, high, and low temperatures are measured using an $Instron^{(R)}$ universal testing machine and an $Instron^{(R)}$ thermal chamber. To characterize the nonlinear behavior of the inflated membrane structure due to wrinkling, the bending behavior of an inflated cylindrical boom made of a fabric membrane is observed at various pressure levels. Moreover, the envelope of a stratospheric airship is numerically modeled based on the thermoelastic properties of the fabric membrane obtained from experimental data, and the wrinkled deformed shape induced by a thermal load is analyzed.

Repair of an oroantral communication by a human amniotic membrane: a novel technique

  • Lakshmi, Subha;Bharani, Siva;Ambardar, Kalhan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.4
    • /
    • pp.194-197
    • /
    • 2015
  • The amniotic membrane is the innermost layer of fetal membrane and is attached to the chorion in the placenta. This membrane has been used for nearly a century in varied fields such as ophthalmology, reconstructive surgery, and burn treatment. In this case report, we used a human amniotic membrane to repair an iatrogenic oroantral communication that occurred during the extraction of the patient's right upper second molar. A splint was given after the perforation was covered with human amniotic membrane and healing was clinically evaluated at various intervals. The outcome of the study revealed that the human amniotic membrane was an efficient graft material for repairing the defect caused by an iatrogenic oroantral communication following tooth extraction.

Preparation of Titanium Microfiltration Membrane by Field-flow Fractionation Deposition

  • Wang, QiangBing;Tang, HuiPing;Zhang, QianCheng;Qiu, QunFeng;Wang, JianYong
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.312-313
    • /
    • 2006
  • The primary aim pursued by the preparation of separation membrane is the preparation of the membrane thin as well as with no defect. The field-flow fractionation deposition is a new molding technology which can overcome the traditional disadvantages such as multi-preparation to the preparation of great area of separation membrane with no defect. Therefor the mainly ingredients which influence the appearance and performance of titanium membrane layer are investigated by scanning electricity mirror (SEM) as well as porous material testing instrument: powder performance prepared and confected; selection of supporting body; sintering system such as temperature and time. It is shown that the membrane thickness can be controlled at $50{\mu}m$ or so; the filtration precision mainly rests with powder performance and selection of supporting body and little sintering system

  • PDF

Development of Mixed Conducting Ceramic Membrane for High Purity Hydrogen and Carbon Production from Methane Direct Cracking (복합전도성 세라믹 분리막의 탄화수소 직접분해에 의한 고순도 수소와 탄소 제조)

  • Kim, Ji-Ho;Choi, Duck-Kyun;Kim, Jin-Ho;Cho, Woo-Seok;Hwang, Kwang-Taek
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.5
    • /
    • pp.649-655
    • /
    • 2011
  • Methane direct cracking can be utilized to produce $CO_x$ and $NO_x$-free hydrogen for PEM fuel cells, oil refineries, ammonia and methanol production. We present the results of a systematic study of methane direct cracking using a mixed conducting oxide, Y-doped $BaZrO_3$ ($BaZr_{0.85}Y_{0.15}O_3$), membrane. In this paper, dense $BaZr_{0.85}Y_{0.15}O_3$ membrane with disk shape was successfully sintered at $1400^{\circ}C$ with a relative density of more 93% via addition of 1 wt% ZnO. The ($BaZr_{0.85}Y_{0.15}O_3$) membrane is covered with Pd as catalyst for methane decomposition with an DC magnetron sputtering method. Reaction temperature was $800^{\circ}C$ and high purity methane as reactant was employed to membrane side with 1.5 bar pressure. The $H_2$ produced by the reaction was transported through mixed conducting oxide membrane to the outer side. In addition, it was observed that the carbon, by-product, after methane direct cracking was deposited on the Pd/ZnO-$BaZr_{0.85}Y_{0.15}O_3$ membrane. The produced carbon has a shape of sphere and nanosheet, and a particle size of 80 to 100 nm.

Analysis of Physical Performance, Hygiene and Safety of Silicone-Laminated Stretch Material (실리콘이 라미네이팅된 신축성 소재의 위생 및 안전성과 역학적 성능)

  • Kwon, Myoung-Sook;Jung, Gi-Soo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.1 s.160
    • /
    • pp.77-84
    • /
    • 2007
  • The purpose of this study was to investigate and to compare the performances of silicone laminated materials sold for swimming cap in market, to get the basic data for product development. We selected 4 specimens and tested their air permeability, waterproofness and breathability. We also tested the physical and mechanical properties of the specimens using KES system. Silicone-laminated material was not bursted on high hydraulic pressure since silicone membrane gave waterproofness while PU/Polyester substrate gave elasticity. It didn't have air permeability and breathability at all. Any toxic materials such as Formaldehyde, Deldrin, PCP, Amin, TDBPP were not detected in silicone-laminated material and other materials. Silicone-laminated material had higher stretchability with the low force but it had lower elastic recovery and shape stability comparing to PU laminated material. It had lower flexibility than PU laminated material. It had lower unrecoverable amount in shearing direction. Friction coefficient was higher in silicone-laminated material than PU laminated material due to its surface stickiness. It was compressed easily and its compression resiliency was higher with compared to PU laminated material.

DEVEOPMENT OF MEASURING SYSTEM OF MEMBRANE STRESS FOR MEMBRANE STRUCTURE (막구조물의 막장력 측정장치 개발에 관한 연구)

  • Jung, Hwan-Mok;Woo, Jae-Won;Cho, Byung-Wook;Lee, Seong-Yeun
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.171-178
    • /
    • 2008
  • This paper is concerned with the development of a measurement system using field measuring device which will give the membrane stress of the membrane structures. Up to this point, several techniques on measurement of membrane stresses has been proposed and some have been used in the fields, but accuracy of the measured stresses to be far from reliable one. Such situation has not been changed until recent days, we do not have the measurement device on which we can depend. On top of that, due to the different properties in cross directions for material of the membrane, the stress in the warp direction is different from that in the fill one. A new method is proposed to measured membrane stresses in two different direction separately, where instead of membrane stresses directly, an external force perpendicular to the membrane to be applied. A portable device can measure the applied force and the displacement. A special testing bed to be fabricated to accommodate $50cm{\times}50$ manbrane specimen which can apply 5 ton load in two orthogonal direction. A special device using push-pull gage was developed. To measure the membrane stresses in warp and fill direction separately, a different length of the tips are used. The measuring device which can called tension meter, can be calibrated on the testing bed, and optimized the length and shape of tip.

  • PDF

Design, fabrication, and performance analysis of a twisted hollow fibre membrane module configuration

  • Palmarin, Matthew J.;Young, Stephanie;Lee, Tsun Ho
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.15-26
    • /
    • 2015
  • The compact structure and high-quality effluent of membrane bioreactors make them well-suited for decentralized greywater reclamation. However, the occurrence of membrane fouling continues to limit their effectiveness. To address this concern, a unique membrane module configuration was developed for use in a decentralized greywater treatment system. The module featured local aeration directly below a series of inclined membrane bundles, giving the overall module a twisted appearance compared to a module with vertically orientated fibres. The intent of this design was to increase the frequency and intensity of collisions between rising air bubbles and the membrane surface. Material related to the construction of custom-fit modules is rarely communicated. Therefore, detailed design and assembly procedures were provided in this paper. The twisted module was compared to two commercially available modules with diverse specifications in order to assess the relative performance and marketability of the twisted module with respect to existing products. Contaminant removal efficiencies were determined in terms of biochemical oxygen demand, chemical oxygen demand, ammonia, total nitrogen, total phosphorus, and turbidity for each module. Membrane fouling was monitored in terms of permeate flux, transmembrane pressure, and membrane resistance. Following 168 h of operation, the twisted module configuration demonstrated competitive performance, indicating good potential for further development and commercialization.

Development of Biodegradable Polymeric Membrane for Interventional Procedure: Preliminary Study (인터벤션 시술을 위한 생분해성 고분자막의 개발 : 예비연구)

  • Bang, Jung-Wan;Hyun, Chang-Yong;Kim, Tae-Hyung;So, Woon-Young;Kim, Jin-Tae;Kim, Sang-Sub;Jung, Hee Dong;Heo, Yeong Cheol
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • This study was to evaluate clinical feasibility of biodegradable polymeric membrane for interventional procedure in preliminary study. Bio-degradable polymetric membrane was produced into a solution by mixing hyaluronic acid powder with NaOH solution in a heating mantle. Three different concentrations of contrast media (10, 20, and 30 vol%) were added to the produced soluble powder, and vertical agitation was performed for 12 hours at a speed of 100 to 200 rpm at a room temperature. It was freeze dried for 24 hours at a temperature $80^{\circ}C$. Pressure on the freeze dried sample was exerted by a hydraulic press in order to form the freeze dried sample into a membrane. The membrane produced with varying contrast medium concentration was visually examined by a scanning electron microscope and radiographically inspected. Under the visual examination, the higher the concentration of contrast medium, the rougher the surface. Radiographic transparency was similar under all conditions of fluoroscopic radiography, simple radiography, and serial radiography. In conclusion, this preliminary study verified that bio-degradable membrane produced with hyaluronic acid was a material with clinical usability.

The Fine Structure of Collar Cell in Tentacles of Chinese Mystery Snail, Cipangopaludina chinensis malleata Reeve (논우렁이 촉수(觸手) 칼라세포(Collar Cell)의 미세구조(微細構造)에 관한 연구(硏究))

  • Song, Yong-Jik;Kim, Woo-Kap;Kim, Chang-Whan
    • Applied Microscopy
    • /
    • v.17 no.2
    • /
    • pp.23-30
    • /
    • 1987
  • There are groups of large monopolar cells containing numerous secretory inclusions in the muscular and connective tissue. These cells contain the electron-lucent vesicles in the size of $0.5{\sim}0.9{\mu}m$, which are secreted to the exterior of the tentacle through their cytoplasmic processes projected to the epithelial layer. Secretory material can be seen accumulating in swollen portions of the granular endoplasmic reticulum. It is postulated that this material is transported to the Golgi-complex and thus the limiting membrane of the inclusions is derived from the Golgi-membrane. An electron lucent material secreted from these cells seems to be similar to fibrous electron lucent material filled in the brush border of the epidermis.

  • PDF

Preparation and Characterization of Composite Membrane for Low Temperature Direct Methanol Fuel Cells

  • Huang Sheng-Jian;Lee Hoi-Kwan;Kang Won-Ho;Wu Qing
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.4 s.33
    • /
    • pp.69-73
    • /
    • 2004
  • A series of $H_3PO_4$-doped composite membranes based on poly(vinyl alcohol)(PVA) and silica have been prepared by sol-gel process. The proton conductivity, as well as properties of swelling, methanol permeation, was measured in this study. The proton conductivity increased with the molar ratio of $H_3PO_4$ to silica. With the silica content increasing, swelling degree decreased and methanol permeability showed a slight increase. It suggested that the former was mainly determined by hydrophilicity of the membrane, while the latter was dominated by the interconnectivity of matrix. According to the value of on, the optimal conformations of these composite membranes were 60, 70, 80 wt.$\%$ of PS-x in membranes, where x were 1.5, 1.0, and 0.5, respectively. These composite membranes were thermal stability up to $200^{\circ}C$.

  • PDF