• Title/Summary/Keyword: membrane filtration system

Search Result 197, Processing Time 0.026 seconds

A study on the treatment of water discharge from the water treatment plant using end-free submerged membrane - Causes and solution of membrane fouling - (자유 말단형 침지식 분리막을 이용한 정수장 배출수 처리 연구 - 막오염 발생 원인과 해결 방안 -)

  • Kim, Jun-Hyun;Jang, Jung-Woo;Kim, Jin-Ho;Park, Kwang-Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.93-104
    • /
    • 2020
  • As water resources are limited and legal regulations are strengthened, there is a growing need to reuse residuals in WTP(Water Treatment Plant). In this study, membrane filtration system was constructed and its operation method was studied for water quality stabilization and reuse of WTP residuals. The operation parameters were stable for 1 year and 6 months. Membrane fouling was identified as particulate pollution (activated carbon) and inorganic pollution (manganese). The membrane system was operated steadily with raw water of high concentration SS(Suspended solid) containing activated carbon because membrane fouling was reduced by the effect of End-Free type. In the case of inorganic contamination, dissolved manganese eluted by chemicals and acted as a membrane fouling source, and the operating conditions for minimizing membrane fouling. were confirmed by newly developing application methods and types of cleaning chemicals. Based on the results, design parameters for reducing manganese membrane fouling were derived.

Evaluation of operating performance of secondary effluents treatment membrane system adapted chemical backwashing (약품역세를 적용한 하수재이용 막여과 시스템의 운전성능 평가)

  • Kim, Young-Hoon;Lee, Chang-Ha;Jeon, Min-Jung;Lee, Yong-Soo;Lee, Eui-Jong;Nam, Jong-Woo;Kim, Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.335-342
    • /
    • 2011
  • Secondary effluent contains particle compounds which are comprised of microorganisms that occurs membrane fouling when the water is reused. This study evaluates the characteristics of membrane fouling of secondary effluent reuse. Effects of chemical backwashing are analyzed to reduce membrane fouling by regular chemical backwashing. As the result, major membrane foulants are verified EPS materials which include protein and polysaccharide that cause biofilm cake layer on the membrane. Also, sodium hypochlorite is applied to chemical backwashing. The backwashing improves recover rate when injected chemical concentration is increased and chemical backwashing cycle is amplified. Chemical backwashing cycle affects more than injected chemical concentration yet idle time does not noticeably influence on reducing membrane fouling.

Membrane-Coupled Sequencing Batch Reactor System for the Advanced Treatment of Rural Village Sewage (막결합 연속회분식 반응기를 이용한 농촌마을 하수의 고도처리)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.24 no.1
    • /
    • pp.20-30
    • /
    • 2014
  • A membrane-coupled sequencing batch reactor (MSBR) was used for the advanced treatment of rural village sewage which is very low C/N ratio. The effect of powdered activated carbon, aeration rate, and external organic material loadings on the treatment efficiency and filtration performance were investigated in sequencing batch reactor, in which a flat-sheet type microfiltration membrane with a pore size of $0.4{\mu}m$ was submerged. At the initial operation (within 54 days) MLSS concentration, and the removal efficiencies of COD, T-N, and T-P were increased with the increase of C/N ratio. After 89 days the removal efficiencies of COD, T-N, and T-P were 97.1%, 75.0%, and 48.3%, respectively. Suspended solid-free effluent was obtained by membrane filtration. The T-P removal was relatively low because of depending on the amount of excess sludge wasting. During the operation of MSBR with powdered activated carbon, the particle size of the sludge reduced by the increase of collision frequency and mixing intensity. In comparison with MSBR without powdered activated carbon, TMP of MSBR with that was significantly elevated.

A Study on the Semiconductor Wastewater Treatment and Recycling by VSEP system (진동막분리장치에 의한 반도체폐수처리와 재이용에 관한 연구)

  • Kang Gyung-Hwan
    • Journal of Environmental Science International
    • /
    • v.14 no.3
    • /
    • pp.335-343
    • /
    • 2005
  • The objective of this research is to evaluate a feasibility of wastewater reuse by membrane treatment with vibrating membrane separation equipment. Molecular weight of compounds in wastewater, permeability of membrane and retentate characterization after membrane filtration were investigated in order to determine appropriate membrane pore size and materials for wastewater treatment. Selected membrane was evaluated with vibration membrane separation equipment to optimize operating conditions. The following conclusion are drawn. 1. We got as following test results after the distribution of particles in the semiconductor wastewater, are made up of $1\~20{\mu}m$. Si, gold and Al in turn are contained in semiconductor wastewater. 2. Recovery rate is changeless under increasing recovery rate in operation. Though a value can be if pressure can be changed, the highest value of permeate rate is presented in 150 psi. 3. The AS-100(polysulpone) was selected as the most appropriate membranes for the treatment of semi-conductor wastewater to VSEP system. The fouling almost did not occur during this experiments. The analyses of treated water with VSEP system showed conductivity: 0.059,us/cm, TDS: 40mg/l, COD: 20mg/l, SS : 5mg/l, n-Hexane: 8.3mg/l. Comparing previous systems, operating expenses is decreased by more $50\%$.

A Study on the Potable Water Purification System with Pre-Ozone and Ultra Filtration Membrane of Hollow Fiber Type (전오존과 중공사형 한외여과막을 이용한 간이정수처리시스템에 관한 연구)

  • Kim, Min-Kuk;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.196-204
    • /
    • 2005
  • The objective of this study is to evaluate the possibility to apply pre-ozone and membrane system for drinking water. This system is improved in fouling control by pre-ozone system. It is composed of ultrafiltration hollow fiber type membrane and ozone reactor. The result of this study is that the flux is increased about 10.7% and decreased in TMP by the pre-ozone. Also, backwashing pressure decreased about 18%. The optimum concentration of residual ozone is 0.3~0.5 ppm. During the period, the recovery ratio of this system was turned out to be 90% as the flowrate of effluent is $67.1m^3/day$. When the TMP and backwashing pressure was $0.85kg/cm^2$ and $1.10kg/cm^2$, this system was stable without sudden fouling. Finally, the quality of effluent is satisfied the guidelines for potable water quality such as turbidity, color, E.coli, Mn, Al, Fe and so on.

Filtration Characteristics of Membrane-coupled Fermentor System for Dissolved Organics Recovery From Liquid Organic Sludge (액상유기성슬러지로부터 용존유기물의 회수를 위한 막결합형 발효 시스템의 여과 특성)

  • Jong Oh Kim
    • Membrane Journal
    • /
    • v.13 no.2
    • /
    • pp.65-72
    • /
    • 2003
  • This study was focused on the investigation of filtration characteristics of membrane-coupled fermentor system for dissolved organics recovery from liquid organic sludge. On the filterability of MF over the range of $0.1{\sim}5 {\mu}m,$ the magnitude of total membrane resistance ($R_t$) is ranged as follows in the order; $0.1 {\mu}m>0.2{\mu}m>0.5 >1{\mu}m>2{\mu}m>5{\mu}m$. The cake layer resistance ($R_c$) occupied about 68~88% of total resistance with fermented sludge. Permeation flux decline was mainly attributed to the $R_c$, which was formed by a strong deposition from physico-chemical interactions of solids on membrane surface. Higher suspended solids (SS) concentration of suspension caused lower permeation flux. However, there was not a proportion relation beyond a certain SS concentration. The cross-flow velocity on the membrane surface was faster, which resulted in the higher permeation flux and also more efficient with low trans membrane pressure (TMP) in viewpoint of energy efficiency. The appropriate pH of suspension was over the range of 5.0~6.0 for dissolved organics recovery as well as the permeation flux. It is possible f3r bacteria to be separated perfectly with $0.1{\mu}m\; and \;0.2{\mu}m$ membrane pore size. Based on experimental results, most appropriate membrane pore size for the recovery is believed to around $1{\mu}m$.

Long Term Evaluation of UF Membrane process using River-bed Water (복류수를 이용한 한외여과공정의 장기운전 평가)

  • Kim, Chung H.;Lim, Jae L.;Kang, Suk H.;Kim, Su H.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.429-436
    • /
    • 2008
  • Membrane system has been increasingly considered as a safe and cost-effective water treatment process especially in case of small scale water works. This research is a basis of membrane application in water works through a long period test with obtaining operation skills and evaluation of water quality and cost competitiveness. For the research, the UF membrane system was installed in small water treatment plant that uses river-bed water as raw water. The system was consisted of 2 stage membrane and operated in constant flow mode (Flux: 1.5, 1.0, 0.9, 0.6). In each different flux condition, TMP trends were showed better results at lower flux condition. And through the high flux condition test, it is certified that membrane system could deal with breakdown of one stage. Water quality of permeate was satisfied the water quality standards especially turbidity. To know what mainly causes fouling on membrane, the test by membrane with several cleaning agents and EDX analysis have done in lab. Through the tests, ferrous concentration in raw water, backwashing water and membrane surface etc. was high and it causes fouling inside and outside of membrane. So acid cleaning using organic acid such as oxalic acid is necessary in Chemical in Place (CIP). At the economical aspect the electrical cost of membrane system is higher than that of slow sand filtration but labor cost can be reduced by automation. However, the use of labor should be determined considering effectiveness and stability of operation. Because during the operation, there are several breakdown such as electrical shock by lightning, water drop in summer, etc.

Application of Membrane Processes to the Treatment of Wastewaters in Japan

  • Yamamoto, Kazuo
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.39-50
    • /
    • 1995
  • The membrane processes that are commonly uscd in water and wastewater treatment are reverse osmosis (Ro), ultrafiltration (UF) and microfiltration (MF), which utilize pressure differentials. There is also nano-filtration (NF), or low-pressure reverse osmosis, which is positioned midway between conventional reverse osmosis and ultrafiltration. Reverse osmosis membranes reject dissolved ions, while ultrafiltration can be used to reject relatively larger molecules, such as protein, polysacchalides and so on. Microfiltration is capable of eliminating particles at submicron level. This paper summarizes the characteristics of MSAS process first, as it is the main membrane process applied to wastewater treatment. Two successful examples of the applications, the cases of individual building reuse system and nightsoil treatment, are then shown. The latest trend of new membrane applications, i.e., immersed-type MSAS is also introduced.

  • PDF

Application of Membrane Technology in Japan

  • Minami, Katsuyoshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.58-73
    • /
    • 1995
  • Membrane filtration is a promising technology for efficient solid/liquid separation in water purification. In FY 1991, the Ministry of Health and Welfare, Japanese Government launched a comprehensive research project "MAC 21" for development of membrane technology and its application to public water supply. The project was conducted by the Water Purification Process Association (WPPA), under the supervision of the Institute of Public Health. By the research project from FY 1991 to FY 1993, we confirmed that microfiltration (MF)/ultrafiltration (UF) technology was applicable to water purification and MF/UF was a effective method for the removal of such contaminants as particulate matter and coliforms. The Guideline Committee organized under the Technical Committee prepared a the guidelines on application of membrane system to small-scale public water supplies, based on the results as written above. The guidelines has been published in Dec., 1994 by WPPA.4 by WPPA.

  • PDF

Forward osmosis membrane filtration for microalgae harvesting cultivated in sewage effluent

  • Kim, Su-Bin;Paudel, Sachin;Seo, Gyu Tae
    • Environmental Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.99-104
    • /
    • 2015
  • The purpose of this study is to evaluate the performance of forward osmosis (FO) system for harvesting microalgae cultivated in secondary sewage effluent. Microalgae species used in this study were chlorella sp. ADE4. The drawing agents used for forward osmosis system were seawater and concentrate of sea water reverse osmosis (SWRO) system. Chlorella sp. ADE4 cultured in secondary sewage effluent illustrated moderate efficiency in removal of total nitrogen (TN) (68%) and superior performance in total phosphorus (TP) removal (99%). Comparison of seawater and SWRO concentrate as drawing agent were made in FO membrane separation of the microalgae. The result from this study depicts that SWRO concentrate is strong drawing agent in FO membrane system providing an average dewatering rate of $4.8L/(m^2{\cdot}hr)$ compared to seawater with average dewatering of $2.9L/(m^2{\cdot}hr)$. Results obtained from this study indicated that FO system could be viable option for harvesting the microalgae for further biodiesel production. SWRO concentrate as a drawing agent could be very important finding in field of membrane technology for disposal of SWRO concentrate.