• Title/Summary/Keyword: membrane filtration system

Search Result 197, Processing Time 0.022 seconds

Understanding Alginate Fouling in Submerged Microfiltration Membrane System for Seawater Pretreatment (해수전처리를 위한 침지식 정밀여과 멤브레인 시스템에서 Alginate 파울링의 이해)

  • Jang, Hoseok;Kwon, Deaeun;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.55-61
    • /
    • 2016
  • Organic fouling observed in submerged membrane filtration as a pretreatment for seawater desalination increases energy consumption for membrane operation because of requiring frequent chemical cleaning and membrane replacement. In membrane pretreatment for seawater facing with algae blooms, membrane fouling was observed in submerged microfiltration using sodium alginate model compound which is one of the main components of extracellular polymeric substances. Without aeration, aglinate fouling increased with its concentration while aeration reduced the alginate fouling effectively regardless of its concentration tested. In the absence of aeration, alingate fouling tended to be decreased with increasing calcium concentration. However, this effectiveness was reduced by increasing sodium chloride concentration. At high concentration of sodium chloride and calcium similar to the seawater conditions, aeration reduced initial fouling. However, as time progressed, the effect of increased airflow rate on fouling reduction was not significant, implying that optimum airflow rate to control alginate fouling in submerged microfiltration can exist.

A basic study on the reuse of shipboard wastewater(II) -An advanced treatment of shipboard wastewater by Hollow fiber UF and MF filtration- (선박용수의 재사용에 관한 기초연구(II) -중공사모듈 UF MF 필터에 의한 선박폐수의 고도처리-)

  • 김인수;김억조;김동근;고성정;안종수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.4 no.1
    • /
    • pp.49-56
    • /
    • 1998
  • The Microfiltration and Ultrafiltration were used to treat effluent of secondary municipal wastewater treatment system(Sequencing Batch Reactor). The cross-flow hollow fiber, UF 500,000(NMWC) and MF 0.65$\mu$ membrane were selected as suitable membrane. Short term and long term fouling effect were measured as a factor of flux decrease and the fouling removal effect of mixing air bubble in the penetrant was studied. The removal of anionic sulfactants before and after formation of micelle with several kinds of oil were checked. The test results show that removal of TOC was 70~80%, TN 28% and TP 16%. The decrease of flux due to fouling were 85%(UF) and 90%(MF) after running of 100hrs. The removal of anionic sulfactants were 60~70% notwithstanding micelle or not.

  • PDF

Observations of Treatment Efficiency and Fouling in Submerged Membrane Filtration Treating High-Turbidity Source Water (고탁도 원수대응 침지식 멤브레인 여과에서 공기폭기 및 용액조성에 따른 파울링 및 처리효율 관찰)

  • Jang, Hoseok;Byun, Youngkwon;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.77-83
    • /
    • 2017
  • Transient behavior of fouling resistance was observed with a laboratory-scaled, submerged microfiltration membrane system treating high-turbidity source water consisting of inorganic silica particles and humic acid. Fouling mitigation efficiency with inorganic silica particles caused by aeration was reduced significantly as both humic acid and calcium ion existed together. Scanning electron microscopic observations showed that humic acid was adsorbed onto the surface of inorganic silica particles in the presence of calcium. Turbidity removal was achieved almost completely by submerged MF system regardless of feed compositions. However, the $UV_{254}$ removal of humic acid was improved in the presence of both calcium and inorganic silica particles. Additionally, increasing air-flow rate tended to increase $UV_{254}$ removal efficiency higher than 80%. This may be caused by back-transport of humic acid enhanced by inorganic silica particles providing surface for organic adsorption in the presence of calcium.

Succinate Transport in Rabbit Renal Basolateral Membrane Vesicles (가토 근위세뇨관 Basolateral Membrane Vesicle에서 Succinate 이동 특성)

  • Kim, Yong-Keun;Bae, Hae-Rahn;Rhim, Byung-Yong
    • The Korean Journal of Physiology
    • /
    • v.22 no.2
    • /
    • pp.307-318
    • /
    • 1988
  • Properties of succinate transport were examined in basolaterat membrane vesicles (BLMV) isolated from rabbit renal cortex. An inwardly directed $Na^+$ gradient stimulated succinate uptake and led to a transient overshoot. $K^+,{\;}Li^+,{\;}Rb^+$ and choline could not substitute for $Na^+$ in the uptake process. The dependence of the initial uptake rate of succinate on $Na^+$ concentration exhibited sigmoidal kinetics, indicating interaction of more than one $Na^+$ with transporter Hill coefficient for $Na^+$ was calculated to be 2.0. The $Na^+-dependent$ succinate uptake was electrogenic, resulting in the transfer of positive charge across the membrane. The succinate uptake into BLMV showed a pH optimum at external pH $7.5{\sim}8.0$, whereas succinate uptake into brush border membrane vesicles (BBMV) did not depend on external pH. Kinetic analysis showed that a Na-dependent succinate uptake in BLMV occurred via a single transport system, with an apparent Km of $15.5{\pm}0.94{\;}{\mu}M$ and Vmax of $16.22{\pm}0.25{\;}nmole/mg{\;}protein/min$. Succinate uptake was strongly inhibited by $4{\sim}5$ carbon dicarboxylates, whereas monocarboxylates and other organic anions showed a little or no effect. The succinate transport system preferred dicarboxylates in trans-configuration (furmarate) over cis-dicarboxylates (maleate). Succinate uptake was inhibited by the anion transport inhibitors DIDS, SITS and furosemide, and $Na^+-coupled$ transport inhibitor harmaline. These results indicate the existence of a $Na^+-dependent$ succinate transport system in BLMV that may be shared by the other Krebs cycle intemediates. This transport system seems to be very similar to the luminal transport system for dicarboxylates.

  • PDF

Effect of Media in Advanced Treatment of Sewage Using Submerged Membrane-Coupled Sequencing Batch Reactor (침지형 막결합 연속회분식 반응기를 사용한 하수의 고도처리에서 담체의 효과)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.26 no.6
    • /
    • pp.470-479
    • /
    • 2016
  • In the advanced treatment of sewage using the submerged membrane-coupled sequencing batch reactor (SMSBR) with media, the effect of media on the filtration performance and removal efficiency were investigated. Dosages of the media in the SMSBR were 10% based on working volume of reactor. As a control system, SMSBR without media and PAC, SMSBR with PAC (10 g/L) only, and SMSBR with media and PAC were also operated. The experimental results showed that there was no big difference observed in the removal efficiencies of COD, T-N, and T-P irrespective of the dosages of the media and PAC. But transmembrane pressure (TMP) of SMSBR with media increased slowly during the operation time, while that of SMSBR without media increased rapidly. Using SMSBR with media, it was possible to operate without the membrane cleaning during the 91 days. Using SMSBR with media only, after 80 days the average removal efficiencies of COD, T-N, and T-P were 95.0, 69.3%, and 51.4%, respectively.

Ultrafiltration Treatment for Car Washing Effluent (한외여과막을 이용한 자동차 세척배수의 처리)

  • 장규만
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.202-208
    • /
    • 1999
  • The car washing effluent containing various oils and detergent was treated by ultrafiltration membranes. Dead-end type stirred cell (Amicon 8050) with 10, 30 and lOOk dalton membranes was used to determine permeation and rejection characteristics for the car washing effluent. In case of low molecular weight cut-off membranes, the effect of membrane fouling was weak under the applied pressures. However, the permeation flux for YM100 membrane(look dalton) may be affected by oil layer formation on the membrane surface as well as oil particle plugging for a part of membrane pores due to compressible and deformable oil properties. Oil and particle rejections in the permeates were over 95%, but detergent was passed easily through the membranes. Hence, the permeates containing detergent can be recycled to the system, and may reduce water pollution. Also, the car washing effluent was treated continuously by a capillary type ultrafiltration membrane of MWCO 50k dalton. The experimental data were fitted suitably to the cake filtration model.

  • PDF

Tubular Alumina Microfiltration Membrane System with Periodic N2-back-flushing for Water Treatment

  • Park, Jin-Yong;Park, Seong-Jae;Kim, Geun-Su
    • Korean Membrane Journal
    • /
    • v.10 no.1
    • /
    • pp.26-32
    • /
    • 2008
  • The Gongji stream water of Chuncheon city was filtrated by 2 kinds of tubular alumina ceramic MF membranes with periodic $N_2$-back-flushing. $N_2$-back-flushing time (BT) was changed in $0{\sim}50$ sec at fixed filtration time (FT), or back-flushing period, of 4 min for NCMT-5231 membrane ($0.05\;{\mu}m$). Then, FT was changed in $0{\sim}32$ min at fixed BT of 40 sec for NCMT-7231 $0.1{\mu}m)$). In the viewpoints of total permeate volume ($V_T$), dimensionless permeate flux ($J/J_0$) and resistance of membrane fouling ($R_f$), the optimal $N_2$-BT was 50 sec, which was the longest BT, at 4 min FT for NCMT-5231. It means the longest BT was the most effective to minimize the membrane fouling, and we could acquire the most $V_T$. But the optimal FT for NCMT-7231 was 16 min in the viewpoint of $V_T$, and was 8 min in the viewpoints of $J/J_0$ and $R_f$ at fixed BT of 40 sec. The rejection rates were excellent as $80.6{\sim}96.6\;%$ for turbidity, $35.2{\sim}58.4%$ for $NH_3$-N, $16.3{\sim}45.2%$ for T-P and $16.3{\sim}45.2%$ for $COD_{Mn}$. However, the rejection rate of T-N was very low as $2.7{\sim}13.4%$ and it of TDS below 6.1%.

A Study on the Validity of the Metal Filter Application in MBR Process (MBR 시스템에서의 금속필터 적용타당성 연구)

  • Lee, Min Soo;Lee, Kang Hoon;Lee, Yong Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.32 no.1
    • /
    • pp.66-73
    • /
    • 2022
  • In this study, a method for stabilizing treated water was conducted while maintaining high flux using a metal flat membrane module made of stainless steel. This module had a pore size of 13 ㎛, so it was possible to operate at a high flux from 60 LMH to 100 LMH. However, although SS leaked about 30~50 ppm during initial operation, aggregation was possible because SS acted as aggregation nucleus. While polymer membrane permeate does not have aggregation nucleus, so coagulation is possible but not flocculation. Typically clay or bentonite, which is used as aggregation nucleus, is additionally administered. In this study, the total phosphorus treatment and the quality of the treated water were to promote stability because flocculation was achieved only with SS leakage without the need for such a aggregation nucleus. Finally, the feasibility of operating a metal membrane filter capable of high flux in stable treated water to be applied to the MBR system.

Subcellular Distribution of Heavy Metals in Organs of Bivalve Modiolus Modiolus Living Along a Metal Contamination Gradient

  • Podgurskaya, Olga V.;Kavun, Victor Ya.
    • Ocean Science Journal
    • /
    • v.41 no.1
    • /
    • pp.43-51
    • /
    • 2006
  • Concentration and distribution of Fe, Zn, Cu, Cd, Mn, Pb, Ni among subcellular fractions (cellular membrane structures and cytosol) and Zn, Cu, Cd among cytoplasmic proteins in the kidney and digestive gland of mussel Modiolus modiolus living along a polymetallic concentration gradient were studied. It was found in the kidney of M. modiolus from contaminated sites that the Fe percent increased in the "membrane" fraction, whereas Zn, Pb, Ni and Mn percent increased in the cytosol compared to the kidney of the control mussel. Note kidney cytosol of M. modiolus from clean and contaminated sites sequestered major parts of Cu and Cd. In the digestive gland of M. modiolus from contaminated sites Fe, Zn, Cd, Mn, Ni percent increased in the "membrane" fraction, whereas Cu, Pb percent increased in the cytosol compared to digestive gland of control mussel. Gel-filtration chromatography shows kidney of M. modiolus contains increased metallothionein-like protein levels irrespective of ambient dissolved metal concentrations. It was shown that the metal detoxification system in the kidney and digestive gland of M. modiolus was efficient under extremely high ambient metal levels. However, under complex environmental contamination in the kidney of M. modiolus, the metal detoxification capacity of metallothionein-like proteins was damaged.

Lignin fractionation from waste wood using organosolv treatment combined with membrane filtration

  • Cho, Hyun Uk;Lee, Minjeong;Shin, Jingyeong;Kim, Eun-Sik;Kim, Young Mo
    • Membrane and Water Treatment
    • /
    • v.11 no.1
    • /
    • pp.25-29
    • /
    • 2020
  • The purpose of this study was to investigate the characteristics of lignin fractionated from waste wood (WW) using a two-step process of ethanol organosolv pretreatment followed by ultrafiltration with membranes of different molecular weight cut-offs (1, 5 and 20 kDa). The different permeates obtained were characterized by fourier transform infrared spectroscopy (FT-IR), nuclear magnetic resonance (NMR), thermogravimetric analysis (TGA) and gel permeation chromatography (GPC). The analysis by FT-IR and NMR of these lignins showed that the lignin core was successfully separated from WW. TGA curves confirmed that the thermal properties of lignin fractionated by ultrafiltration were almost identical to each other. The results from GPC confirmed that fractionating of lignin was achieved by ultrafiltration. For the membrane fractionation process, values of molecular weight decreased as the cut-offs used to obtain the fractions became smaller. As a result, fractionating lignin by a two-step process allowed separating different fractions of lignin of different molecular weights yielded high purity without interference from existing pollutants in WW. The two-step process offers the possibility of using fractionated WW as an untapped source of lignin.