• Title/Summary/Keyword: membrane chemistry

Search Result 1,172, Processing Time 0.028 seconds

The Effect of Crosslinking on the Actuation of Electroactive IPMC Prepared with Fluoroalkyl Methacrylate/Acrylic Acid/HEMA Copolymer (Fluoroalkyl Methacrylate/Acrylic Acid/2-HEMA 공중합체로 제조한 IPMC의 구동 특성에 미치는 가교의 영향)

  • Jeong, Han-Mo;La, Young-Soo
    • Polymer(Korea)
    • /
    • v.29 no.5
    • /
    • pp.463-467
    • /
    • 2005
  • In order to enhance the actuation force of ionic polymer-metal composite (IPMC) made with the acrylic copolymer of fluoroalkyl methacryate, acrylic acie, and 2-hydroxyethyl methacrylate(HEMA), the hydroxy group of HEMA was corsslinked with 1,3-diethoxy-1,1,3,3-tetramethyldisiloxane. The water uptake was reduced and the mechanical strengths and the actuation force of the membrane was improved by crosslinking. However, current and deformation responses of IPMC were decreased by crosslinking.

Transdermal Permeation Characteristics of Anti Cholesterol Ointment using Nicotinic acid N-oxide (Nicotinic acid N-oxide를 이용한 항콜레스테롤 연고의 경피 투과 특성)

  • Jung, Duck-Chae;Kim, Kyu-Won
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2008
  • Transdermal therapeutic system(TTS) is often used as the method of drug dosage into the epidermic skin. Natural polymer were selected as ointment material of TTS. We investigated the permeation of natural polymer ointment containing drug in rat skin using horizontal membrane cell model. Permeation properties of materials were investigated for water-soluble drug such as Nicotinic acid N-oxide in vitro. These results showed that skin permeation rate of drug across the composite was mainly dependent on the property of ointment base and drug. Proper selection of the polymeric materials which resemble and enhance properties of the delivering drug was found to be important in controlling the skin permeation rate. This result suggests a possible use of natural polymer ointment base as TTS of antihyperlipoproteinemic agent.

The Transport Phenomena of Some Solutes through the Copolymer Membranes of 2-hydroxyethylmethacrylate (HEMA) with Selected Hydrophobic Monomers

  • Kim, Whan-Gun;Jhon, Mu-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.3
    • /
    • pp.128-131
    • /
    • 1985
  • A series of copolymer membranes of 2-hydroxyethylmethacrylate (HEMA) with selected hydrophobic monomers were prepared without crosslinking agents. The equilibrium water content, the partition coefficient, and the permeability of the solutes such as urea, methylurea, 1,3-di-methylurea, and acetamide via these membranes were measured. The partition coefficient data show that as the hydrophobicity of solutes increased, the partition of solutes were dictated by hydrophobic interaction between solute and polymer matrix. Diffusion coefficients obtained in these experiments decrease as the water content of polymer membrane decreases. This decrease is blunt as the excess heat capacities, ${\phi}C^0_p$ (excess) in aqueous solution at infinite dilution of solute increases. To investigate the relationship between water content and diffusion coefficient, the results of the diffusion experiments were examined in light of a free-volume model of diffusive transport. The remarkable increase of urea mobility in the polymer network containing relatively larger bulk water can be considered as water structure breaking effect.

Progress in the modification of reverse osmosis (RO) membranes for enhanced performance

  • Otitoju, T.A.;Saari, R.A.;Ahmada, A.L.
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.52-71
    • /
    • 2018
  • RO membranes, the core elements for RO process formed using polyamide, have found prominent space in membrane technology. RO membranes with better application perspective could be achieved by precise controlling the kinetics of IP reaction and surface modification strategy. Despite huge progresses, great challenges still exist in trade-off between flux, rejections and fouling. More works are necessary to enhance the performance and stability of RO membranes via surface modification. Further insights into the use of natural monomers are necessary. It is anticipated that this article can provide clues for further in-depth evaluation and research in exploring more advanced RO membranes.

Mechanism of action of ferroptosis and its role in liver diseases

  • Dong-Oh Moon
    • Journal of Applied Biological Chemistry
    • /
    • v.66
    • /
    • pp.159-164
    • /
    • 2023
  • Ferroptosis is a type of regulated cell death recently discovered, characterized by the accumulation of iron-dependent lipid peroxides in the cell membrane, and it involves a complex network of signaling pathways, including iron metabolism, lipid peroxidation, and redox regulation. The dysregulation of these pathways can lead to the induction of ferroptosis and the development of liver diseases, such as alcoholic liver disease, non-alcoholic fatty liver disease, viral hepatitis, and liver cancer. Studies have demonstrated that targeting key molecules involved in iron metabolism, lipid peroxidation, and redox regulation can reduce liver injury and improve liver function in different liver diseases by inhibiting ferroptosis. Thus, modulation of ferroptosis presents a promising therapeutic target for treating liver diseases. However, further research is required to gain a more comprehensive understanding of the mechanisms underlying the role of ferroptosis in liver diseases and to develop more effective and targeted treatments.

A Strip Sensor Based on PbO2/Carbon Paste Electrode to Determine Sweetener Contents in Fruits (이산화납/탄소 반죽 전극을 이용한 과당 농도 측정 스트립센서)

  • Lee, Jae Seon;Cho, Joo Young;Heo, Min;Lim, Woo-Jin;Lee, Sang Eun;Nam, Hakhyun;Cha, Geun Sig;Shin, Jae Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.2
    • /
    • pp.130-137
    • /
    • 2014
  • A strip sensor based on $PbO_2$/carbon paste electrode was prepared by a screen-printing method, and employed to electrochemically determine the concentration of fruit sweeteners(i.e. glucose, sucrose, and fructose). The $PbO_2$/carbon paste electrode could monitor electrocatalytic oxidation of organic compounds such as carbohydrates, and measure the levels of natural sweeteners without enzyme. Severe interference from ascorbic acid was effectively reduced by modifying the electrode surface with a Nafion membrane. The response level of the Nafion/$PbO_2$/carbon paste electrode increased in the order of fructose, sucrose, and glucose, which corresponds to the order of sweetness perceived by humans.

Macrocyclic Isomers with S2O-Donor Set as Silver(I) Ionophores

  • Park, Sung-Bae;Yoon, Il;Seo, Joo-beom;Kim, Hyun-Jee;Kim, Jae-Sang;Lee, Shim-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.713-717
    • /
    • 2006
  • $S_2O$-donor macrocyclic isomers incorporating a xylyl group in o- ($L^1$), m- ($L^2$) and p-positions ($L^3$) extract no metal ions except silver(I) from aqueous to chloroform phase. And the magnitudes of %Ex for silver(I) are in the order of $L^1$ > $L^2$ > $L^3$. Taking this result into account, $L^1$-$L^3$ were utilized as membrane active components to prepare potentiometric silver(I)-selective electrodes. The proposed macrocycles-based electrodes E1 ($L^1$), E2 ($L^2$) and E3 ($L^3$) exhibited comparable results which show considerable selectivity toward silver(I) over alkali, alkali earth and other transition metal ions. Comparative NMR study on $L^1$-$L^3$ and their complexes with silver(I) in solution was also accomplished. In addition, a unique sandwich-type complex $[Ag(L^1)_2]CIO_4$ was prepared from the assembly reaction of $L^1$ with $AgClO_4$ and structurally characterized by an X-ray diffraction analysis.

Laminin-1 Phosphorylation by Protein Kinase A: Effect on self assembly and heparin binding

  • Koliakos, George;Kouzi-Koliakos, Kokkona;Triantos, Athanasios;Trachana, Varvara;Kavoukopoulos, Evaggelos;Gaitatzi, Mary;Dimitriadou, Aphrodite
    • BMB Reports
    • /
    • v.33 no.5
    • /
    • pp.370-378
    • /
    • 2000
  • Incubation of purified laminin1-nidogen1 complexes with $[{\gamma}-^{32}P]-ATP$ in the presence of the catalytic subunit of the protein kinase A (cAMP-dependent protein kinase) resulted in the phosphorylation of the alpha chain of laminin-1 and of the nidogen-1 molecule. Aminoacid electrophoresis indicated that phosphate was incorporated on serine residues. The phosphorylation effect of laminin-1 on the process of self assembly was studied by turbidometry. In these experiments, the phosphorylated laminin-1 showed a reduced maximal aggregation capacity in comparison to the non-phosphorylated molecule. Examination of the laminin-1 network under the electron microscope showed that the phosphorylated sample formed mainly linear extended oligomers, in contrast to controls that formed large and dense multimeric aggregates. Heparin binding on phosphorylated laminin-1 in comparison to controls was also tested using solid-phase binding assays. The results indicated an enhanced heparin binding to the phosphorylated protein. The results of this study indicate that laminin1-nidogen1 is a substrate for protein kinase A in vitro. This phosphorylation had an obvious influence on the lamininl-nidogen1 network formation and the heparin binding capacity of this molecule. However, further studies are needed to investigate whether or not this phenomenon could play a role in the formation of the structure of basement membranes in vivo.

  • PDF

A high-effective method to separate nicotine from the tobacco-specific carcinogen 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) mixtures using electrodialysis

  • Ge, Shaolin;Li, Wei;Zhang, Zhao;Li, Chuanrun;Wang, Yaoming
    • Membrane and Water Treatment
    • /
    • v.8 no.3
    • /
    • pp.245-257
    • /
    • 2017
  • The separation of nicotine and tobacco-specific N-nitrosamines is a tough problem in tobacco industry. In this study, separation of nicotine from 4-(methylnitrosamino) -1-(3-pyridyl)-1-butanone (NNK) mixtures was investigated using electrodialysis by taking the principle of the protonation status difference between these two components. The results indicated that the solution pH has a dominant impact on the separation process. In a pH range of 5-7, nicotine molecules are existed as mono- and di-protonated ions and can be separated from the uncharged NNK molecules. The acidic electrolyte is conducive to the separation process from the point of flux and energy consumption; while the alkaline electrolyte has negative impact on the separation process. A current density of $10mA/cm^2$ is an appropriate value for the separation process. The lowest energy consumption of the separation process is 0.58 kWh/kg nicotine with the process cost to be estimated at only $0.208 /kg nicotine. Naturally, electrodialysis is a high-efficiency, cost-effective, and environmentally friendly process to separate and purify nicotine from tobacco juice.

Correcting Errors Associated with Blood Urea Measurements Employing Nonaction-Doped Ammonium-Selective Electrodes (암모늄선택성 전극을 이용한 요소센서의 오차보정에 관한 연구)

  • Kim, Young No;Shin, Doo Soon;Kim, Chang Yong;Shin, Jae Ho;Nam, Hakhyun;Cha, Geun Sig
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.12
    • /
    • pp.925-931
    • /
    • 1995
  • Urea sensors, prepared by immobilizing urease on ammonium-selective membrane electrodes doped with nonactin, can show interference from several ionic species present in blood samples (e.g., sodium, potassium, and endogenous ammonium ions). This interference problem does not arise from the immobilized biocatalytic reaction but rather from the innate response of the base transducer to ionic species in the sample. In this work, the use of calibrators containing adequate amounts of ionic species is examined to reduce errors caused by endogenous ionic interferences with blood urea measurements. Simultaneous measurements of the interfering species with additional sensors and subsequent substractions of these values from the urea electrode signals are also described. It is shown that the use of a potassium-selective electrode with an adequate calibrator system greatly enhances the accuracy of the urea sensor measurements.

  • PDF