• Title/Summary/Keyword: membrane PD

Search Result 131, Processing Time 0.03 seconds

Modelling and Simulation of H2 separation in Pd Membrane System with Co-current and Current-current Flow (병류와 향류 흐름에서 수소분리를 위한 Pd 분리막 시스템의 모델링 및 모사)

  • Yi, Yong;Noh, Seunghyo;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.598-602
    • /
    • 2010
  • In this paper, we carried out CFD modelling and simulation for the membrane system to separate H2 gas from the multi-component feed gas. The membrane system is of the annulus tubular type consisting of the external lumen side for the feed gas and the internal permeation side for the sweeping gas. The operating temperature and pressure of the lumen side inlet flow are $374^{\circ}C$ and 7 bar respectively and those of the sweeping gas are $374^{\circ}C$ and 3 bar, and considering these conditions, Pd membrane system was employed. CFD simulations were performed for the co-current flow and counter-current flow membrane system based on the flow directions between the feed and the sweeping gas. Comparisons and discussions were made for the H2 partial pressure, H2 mole fraction and H2 flux for both cases. Furthermore, we executed CFD simulations for the each case of the various inlet flow rates of the feed gas at the lumen side. Accordingly, we reviewed the effects of the flow rate and residence time on the performance of the membrane system.

Structural properties of Pd-barium zirconate dense membrane synthesized by dual sputtering method (동시 증착 스퍼터링 공정에 의해 증착된 Pd-barium zirconate membrane의 구조분석)

  • Byeon, Myeong-Seop;Kang, Eun-Tae;Cho, Woo-Seok;Kim, Jin-Ho;Hwang, Kwang-Taek
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.1
    • /
    • pp.19-24
    • /
    • 2012
  • Barium zirconate exhibits good thermo-chemical stability and proton conduction at high temperatures, but shows poor electron conductivity. Therefore, for high efficiency of hydrogen separation, a very thin and dense Pd-Barium zirconate membrane has to be coated on a porous substrate. A thin and dense Pd-Barium zirconate membrane was successfully synthesized on a porous substrate by means of dual sputtering method. The structural and chemical features of the $BaZr_{0.85}Y_{0.15}O_{3-{\delta}}$ membranes sputtered at $300^{\circ}C$ and $400^{\circ}C$ were investigated by X-ray diffractometry, and it was found that a well-crystallized membrane, Pm-3m space group of $BaZrO_3$, was synthesized. The surface and cross-sectional morphologies of membrane were assessed by SEM (scanning electron microscopy) and TEM(transmission electron microscopy) of the surface and of cross sections. The cross sectional observation of Pd-$BaZr_{0.85}Y_{0.15}O_{3-{\delta}}$ membrane by dual sputtering shows that the coating is quite dense with columnar structure.

Dense Ceramic-metal Composite Inorganic Membranes for Oxygen Separation (산소 분리를 위한 무공성 세라믹- 금속 복합 무기막)

  • 김진수
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2002.05a
    • /
    • pp.35-41
    • /
    • 2002
  • Dense oxygen ionic conducting materials can be used for oxygen separation membranes at high temperatures. However, they show relatively low permeation flux because of their large resistances. To reduce resistances and improve the oxygen permeation flux, thin dense yttria-stabilized-zirconia (YSZ)/Pd composite dual-phase membranes were fabricated by a new approach that combines the reservoir method and chemical vapor deposition (CVD). A thin porous YSZ layer was coated on a porous alumina support by dip-coating the YSZ suspension. A continuous Pd phase was formed inside pores of the YSZ layer by the reservoir method. The residual pores of the YSZ/Pd layer were plugged with yttria/zirconia by CVD to ensure the gas tightness of the membranes. The oxygen permeation fluxes through these composite membrane were 2.0$\times$10$^{-8}$ mol/cm$^2$.s and 4.8$\times$10$^{-8}$ mol/cm$^2$.s at 105$0^{\circ}C$ when air and oxygen were used as the permeate gases, respectively. These oxygen permeation values are about 1 order of magnitude higher than those of pure YSZ membranes prepared under similar conditions.

  • PDF

ISFET Glucose Sensor with Palladium Hydrogen Selective Membrane

  • Chung, Mi-Kyung;Kim, Seong-Wan;Lee, Sang-Sik;Park, Chong-Ook
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.90-95
    • /
    • 2012
  • This paper describes the development of a glucose biosensor based on ion sensitive field effect transistor(ISFET) with a palladium(Pd) modified ion sensing membrane. By adopting Pd as a hydrogen sensitive layer and integrating a screen-printed reference electrode, the sensitivity and stability were considerably improved due to the high permeability and selectivity of the Pd hydrogen selective membrane. This paper suggests a new approach for realizing portable and highly sensitive glucose sensors for diagnosing and treating diabetes mellitus.

Influence of the Mesophyll on the Change of electrical Potential Difference of Guard Cells Induced by Red-light and CO2 in Commelina communis L. and Tradescantia virginiana L. (닭의장풀과 자주달개비에서 적색광과 이산화탄소에 의해 유도된 공변세포의 전위차 변화에 미치는 엽육세포의 영향)

  • 이준상
    • Journal of Plant Biology
    • /
    • v.36 no.4
    • /
    • pp.383-389
    • /
    • 1993
  • The effects of light and $CO_2$ on the electrophysiological characteristics of guard cells in the intact leaf and in the detached epidermis have been investigated. Guard cells in intact leaves showed the membrane hyperpolarization in response to light. The biggest induced change of the membrane potential difference (PD) in the guard cells of the intact leaf was 13 m V by light and 42 mV by $CO_2$ in Commelina communis. Similar results were obtained with Tradescantia virginiana. However, there were no changes of membrane PD in detached epidermis. In order to determine the influence of the mesophyll on the changes of membrane PD, infiltration of the mesophyll cells with photosynthetic inhibitors was performed. In CCCP infiltrated leaf discs the guard cell membrane was depolarized slightly by red-light and hyperpolarized by $CO_2$, but in leaf discs infiltrated with DCCD and DCMU the guard cell membrane was hyperpolrized by both red-light and $CO_2$ as the control leaf discs. In azide infiltrated leaf discs the guard cell membrane showed no response to light and there was a much reduced membrane hyperpolarization by $CO_2$ compared to other responses. It was likely that azide caused leaf damage and the activity of cell metabolism was decreased greatly, resulting in small membrane PD changes by $CO_2$ and no changes by redlight. Therefore, it can be suggested that red light was sensed by the mesophyll and the light induced guard cell membrane hyperpolarization was related to energy produced by cyclic-photophosphorylation, but ${CO_2}-induced$ guard cell membrane hyperpolarization was not related to photosynthesis. Alkalisation of the vacuole was observed when the intact leaf was exposed to $CO_2$, indicating that membrane hyperpolarization was mainly the result of proton efflux.efflux.

  • PDF

Direct and Indirect Membrane Integrity Tests for Monitoring Microbial Removal by Microfiltration (정밀여과(MF)막 미생물 제거율 모니터링을 위한 막 완전성시험)

  • Hong, Seungkwan;Miller, Frank;Taylor, James
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.801-806
    • /
    • 2004
  • The pilot study was conducted to (i) investigate the ability of various membrane integrity monitoring methods to detect changes in membrane integrity during operation, and (ii) determine the impact of membrane damage on microbial removal by microfiltration. Two variations of air pressure hold tests were investigated for direct integrity monitoring: pressure decay (PD) and diffusive air flow (DAF) tests which are most commonly used integrity tests for microfiltration (MF) membranes. Both PD and DAF tests were sensitive enough to detect one damaged fiber out of 66,000 under field operaing conditions. Indirect integrity monitoring such as turbidity and particle counting, however, responded poorly to defects in membrane systems. Microbial challenge study was performed using both new and deliberately damaged membranes, as well as varying the state of fouling of the membrane. This study demonstrated that MF membrane with nominal pore size $0.2{\mu}m$ was capable of removing various pathogens including coliform, spore, and cryptosporidium, at the level required by drinking water regulations, even when high operating pressures were applied. A sharp decrease in average log reduction value (LRV) was observed when one fiber was damaged, emphasizing the importance of membrane integrity in control of microbial contamination.

Performance Enhancement by Adaptation of Long Term Chronoamperometry in Direct Formic Acid Fuel Cell using Palladium Anode Catalyst

  • Kwon, Yong-Chai;Baik, S.M.;Han, Jong-Hee;Kim, Jin-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.8
    • /
    • pp.2539-2545
    • /
    • 2012
  • In the present study, we suggest a new way to reactivate performance of direct formic acid fuel cell (DFAFC) and explain its mechanism by employing electrochemical analyses like chronoamperometry (CA) and cyclic voltammogram (CV). For the evaluation of DFAFC performance, palladium (Pd) and platinum (Pt) are used as anode and cathode catalysts, respectively, and are applied to a Nafion membrane by catalyst-coated membrane spraying. After long DFAFC operation performed at 0.2 and 0.4 V and then CV test, DFAFC performance is better than its initial performance. It is attributed to dissolution of anode Pd into $Pd^{2+}$. By characterizations like TEM, Z-potential, CV and electrochemical impedance spectroscopy, it is evaluated that such dissolved $Pd^{2+}$ ions lead to (1) increase in the electrochemically active surface by reduction in Pd particle size and its improved redistribution and (2) increment in the total oxidation charge by fast reaction rate of the Pd dissolution reaction.

Characteristics of Nafion Membranes with Pd Thin Films Deposited by DC Magnetron Sputtering Technique (DC마그네트론 스퍼터링으로 Pd박막 입힌 Nafion막의 특성)

  • Hwang, Gi-Ho;Cho, Won-Il;Cho, Byung-Won;Yoon, Sung-Ryul;Ha, Heung-Yong;Oh, In-Hwan;Kim, Kwang-Bum
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.2
    • /
    • pp.68-73
    • /
    • 2002
  • Modified polymer electrolyte membranes were fabricated by the applying dc magnetron sputter-deposited Pd thin layers on the surface of the $Nafion^{TM}$ membranes in argon atmosphere. The Pd thin films were characterized by investigating its morphology, methanol permeability, and protonic conductivity. The performance of a direct methanol fuel cell(DMFC) with the modifed polymer electrolyte membrane was also tested by the measurement of its currents and voltages under flowing methanol. The Pd thin film could be a barrier layer to methanol crossover, but the protonic conductivity of the modified polymer membrane was reduced. By using the modified polymer eletrolyte membranes, both the methanol permeability and the protonic conductivity were decreased with increasing the thickness of Pd thin film. However, the performances of DMFC were almost independent on the thickness of Pd thim films. The efffcts of methanol concentration in a feeding fuels on the protonic conductivity and the cell performance were also investigated.