• Title/Summary/Keyword: medical technologist

Search Result 196, Processing Time 0.023 seconds

Usefulness of 3D Rotational Angiography for Cerebral Vascular Diameter Measurement (뇌혈관 직경측정을 위한 3차원 회전 혈관조영술의 유용성)

  • Seung-Gi, Kim;Sang-Hyun, Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.9-14
    • /
    • 2023
  • When measuring cerebrovascular with 3D rotational angiography, the accuracy was verified by comparing the actual size and measurement size, respectively. It is intended to help select therapeutic materials and instruments during cerebrovascular intervention by comparing the average error rates for measured values in the 3DRA and CTA methods by examining with protocols such as brain CTA, which are always performed in emergency situations. The mean error rate between the groups of measurers was ±3.655% for radiation technologist and ±3.331% for university students, and the mean error rate of the student group was within tolerance (±10%), and the independent sample T-test result t =0.879, p=0.394 (p>0.05) showed no statistically difference between the two. In addition, the average error rate measured by both groups by 3DRA was measured below ±5% within the tolerance error rate (±10%), and most of CTA was measured within the tolerance range (±10%), but showed an average error rate of up to 5.65%, and the independent sample T-test result was statistically more accurate than 3DRA. Both the 3DRA method and the brain CTA method for measuring cerebrovascular size could be accurately measured within tolerance, but it would be better to measure cerebrovascular blood vessels using a more accurate 3DRA method during cerebrovascular intervention.

A Study on the Status of Medical Equipment and Radiological Technologists using Big Data for Health Care: Based on Data for 2020-2021 (보건의료 빅데이터를 활용한 의료장비 및 방사선사 인력 현황 연구 : 2020-2021년 자료를 기준으로)

  • Jang, Hyon-Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.667-673
    • /
    • 2021
  • As we enter the era of the 4th industrial revolution, it is judged that the scope of work of radiologists will be further expanded according to the innovation and advancement of radiation medical technology development. In this study, the current status of medical equipment and radiology technicians was identified, and basic data were provided for the plan for nurturing talents in the field of radiation medical technology in the era of the 4th industrial revolution, as well as career and employment counseling. Data from the second quarter of 2020 and the second quarter of 2021 were analyzed using health and medical big data. As a result of comparing the status of medical equipment by type in 2021 compared to 2020, C-Arm X-ray examination equipment increased by 5.83% to 6,638 units, followed by MRI examination equipment 1,811 units 5.29%, and angiography equipment 725 units 5.22% , general X-ray examination equipment 21,557 units increased 3.99%, CT examination equipment 2,136 units 3.03%, and breast examination equipment 3,425 units increased 3.00%. As a result of a comparison of the total number of radiologists in 2021 compared to 2020, the number was 29,038, an increase of 2.73%. As a result of comparing the status of radiographers by region, the increase was highest in the Gyeonggi region with 5.96%, followed by the Gangwon region with a 5.66% increase and the Chungnam region with a 3.81% increase. In a situation where the number of medical equipment and radiologist manpower is increasing, universities are developing specialized knowledge and practical competency through subject development related to the understanding and utilization of customized artificial intelligence and big data that can be applied in the medical radiation technology field in the era of the 4th industrial revolution. It is necessary to nurture qualified radiographers, and at the level of the association, it is thought that active policies are needed to create new jobs and improve employment.

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF

The Influences of Bowel Condition with Lumbar Spine BMD Measurement (요추부 골밀도 측정 시 장내 변화가 골밀도에 미치는 영향)

  • Yoon, Joon;Kim, Yun-Min;Lee, Hoo-Min;Lee, Jung Min;Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.273-278
    • /
    • 2014
  • Bone density measurement use of diagnosis of osteoporosis and it is an important indicator for treatment as well as prevention. But errors in degree of precision of BMD can be occurred by status of patient, bone densitometer and radiological technologist. Therefore the author evaluated that how BMD changes according to the condition of the patient. As Lumbar region, which could lead to substantial effects on bone density by diverse factors such as the water, food, intentional bowels. We recognized a change of bone mineral density in accordance with the height of the water tank and in the presence or absence of the gas using the Aluminum Spine Phantom. We also figured out the influence of bone mineral density by increasing the water and food into a target on the volunteers. Measured bone mineral density through Aluminum Spine Phantom had statistically significant difference accordance with increasing the height of water tank(p=0.026). There was no significant difference in BMD according to the existence of the bowl gas(p=0.587). There was no significant difference in a study of six people targeted volunteers in the presence or absence of the food(p=0.812). And also there was no significant difference according to the existence of water(p=0.618). If it is not difficult to recognize the surround of bone in measuring BMD of lumbar bone, it is not the factor which has the great effect on bone mineral density whether the test is after endoscopic examination of large intestine and patient's fast or not.

Changes in Compliance Rates of Evaluation Criteria After Healthcare Accreditation: Mainly on Radiologic Technologists working at University Hospitals in Daejeon Area (의료기관인증평가 전후 인증기준 준수율의 변화 : 대전지역 대학병원의 방사선사를 중심으로)

  • Ko, Eun-Ju;Lee, Jin-Yong;Bae, Seok-Hwan;Kim, Hyun-Joo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.281-290
    • /
    • 2013
  • This study aimed to assess whether the changes in compliance rates of evaluation criteria after healthcare accreditation among radiologic technologists working at four university hospitals which had acquired healthcare accreditation in Daejeon metropolitan area. In this study, the evaluation criteria of healthcare accreditation were reclassified and reevaluated to three areas which include patient safety, staff safety, and environmental safety. Each area has eight, three, and five questions, respectively. Each compliance rate was quantitatively measured on a scale of 0 to 10 before and after in this study. The result shows that the overall compliance rates were decreased on all areas compared to the time healthcare accreditation was obtained. The compliance rate of hand hygiene was drastically reduced. To maintain the compliance rates, not only individuals but healthcare organizations should simultaneously endeavor. In particular, healthcare organizations should make an effort to provide continuous education opportunity to their workers and supervise the compliance regularly.

Analysis of Survey of Interdisciplinary Unification of Biomedical Laboratory Science (임상병리학과 학제단일화에 대한 설문조사 분석)

  • Kim, Hong Sung;Kang, Ji-Hyuk;Yang, Man-Gil;Park, Chang-Eun;Shin, Kyung-A;Kwon, Pil Seung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.289-296
    • /
    • 2018
  • Opinions regarding interdisciplinary unification of medical laboratory science were analyzed by an online questionnaire distributed to 255 professors and 4,000 hospital practitioners in January of 2018. The recovery rate was 79 (30.9%) for professors and 1,368 (34.2%) for hospital practitioners. In the perception survey on the duality of interdisciplinary, both the professors and the hospital practitioners reported that they felt interdisciplinary integration is necessary. The prerequisite of four-year integration was the establishment of institute of accreditation and standardization of curriculum, and the requirements for the four-year integration were considered important for adjustment of student quota and standardization of curriculum. In the four-year integrated approach, the opinion that only universities that passed the accreditation evaluation should operate a four-year system was highest among professors and hospital practitioners. The optimum capacity of university students was less than 40 in cases of 4-year integration. In conclusion, the above results suggest that the professors and hospital practitioners realize 4-year interdisciplinary integration is necessary to produce a competent medical technologist, and the institute of accreditation, standardization of curriculum, and student quota adjustment should be presupposed for 4-year integration.

Infection Control of Computed Radiography Portable in Radiology (영상의학과 이동촬영장비의 감염 관리)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2017
  • The purpose of this study is to prevent infection in the hospital by computed radiography portable and to provide basic data on infection-related education by investigating bacterial contamination level of computed radiography portable equipment using IP cassette. The results suggest that IP cassette No. 1 is infected with CNS and VRE, no. 2 with CNS, No. 3 with CNS and Pseudomonas aeruginosa, No. 4 with CNS, No. 5 with CNS and Bacillus sp., and No. 6 with enterococcus faecium. Enterococcus faecium and bacillus sp. were detected from the IP reader and Acinetobacter baumannii was detected on the mobile handle; Bacillus sp. on the control buttons, CNS and Bacillus sp. from the irradiation control handle, Acinetobacter baumannii on the x-ray generation switch, and CNS on the barcode scanner. In addition, Bacillus sp. Acinetobacter baumannii was found on the IP cassette mobile table and CNS and bacillus sp. were found on the lead apron. Acinetobacter baumannii and CNS were detected from the medical gloves worn by a radiological technologist during radiography. This suggests that IP cassette should be sterilized after use as it can hand over bacteria to IP reader and IP mobile table. Medical gloves that are in direct contact with patients should also be replaced after using them once and other supplies such as x-ray generation switch and lead apron should thoroughly be sterilized to prevent infection due to radiography as they are in a lot of contact with patients.

Study on the Difference of Urine Sediment Preparation for Microscopic Examination (현미경검사를 위한 요침사 표본제작에 따른 차이 연구)

  • Lee, Hyeok-Jae;Park, Chul;Seo, Min-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.366-373
    • /
    • 2017
  • Urinalysis is considered to be easier and simpler than other tests. It has been known to cause no burden to patients, while offering important information on diagnosing, treating, and determining the prognoses of kidney and urinary tract diseases. Urinary sediments are usually performed by microscopic examination of centrifuged urine by technologist. The guidelines proposed by the Korean Association of External Quality Assessment Service are actually different from those actually practiced by medical institutions and taught to biomedical students in textbooks. Therefore, we verified whether different sediment preparation methods lead different test results. Specimens that tested positive from the occult blood and leukocyte esterase in the urine dipstick test were randomly selected for a microscopic examination. The differences in the urine sediment preparation affected the sediment concentrations, which influenced the cell grade and cell number per HPF. The first factor in determining the sediment concentration is the centrifugal force. Many medical institutions use 1,500 rpm as the centrifugal speed without considering the radius of the centrifuge; such a value may not be accurate for 400 G. Consequently, there were differences in urine concentrations, which influenced the results. The second factor is the amount of sediment in urine. Different amounts of the remaining supernatant led to different sediment concentration factors, again, causing different results. Furthermore, not only by using a pipette to obtain an accurate amount as stipulated, but also by roughly obtaining a drop, the microscopic examination using such a volume of sediment examined affected the results. Therefore, this study highlights the importance of standardization of urine sediment preparation procedures to promote consistency and accuracy across institutions.

The Analysis of Regional Stressor Level on Personal Factor and Reaction According of Radiological Technologist (방사선사의 개인요인과 반응에 따른 지역별 스트레스원 수준 분석)

  • Jung Hong-Ryang;Son Bu-Soon;Lim Cheong-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.266-279
    • /
    • 2005
  • The present study was conducted to analyze the causes of stress on the part of Korean radiological technologists depending on their working environments. For this purpose, 890 questionnaires were distributed to and collected from radiological technologists who were working at 44 general hospitals in 16 cities and provinces of Korea during the period from the mid July to the end of August 2003. The collected data were compared between regions, divided into the capital, metropolitan, medium and small cities, whose results are as follows: 1. As factors affecting working conditions, drinking was found to exert more influence on radiological technologists in small- and medium-sized cities, while loyalty to immediate seniors and organizations was the one producing greater influence on them in metropolitan cities than other cities. Overall, position, job satisfaction and physical condition seemed to have a great effect on them (p<0.001).2. In terms of factors related to their roles, job satisfaction and physical condition played in general a greater role for radiological technologists (p<0.001). Immediate seniors and behavioral conducts were also found to have a lot influence on them (p<0.01).3. As for job conflicts, the kind of medical institutions seemed to exercise a great deal of impact on radiological technologists (p<0.05), while colleagues, immediate seniors, job satisfaction and physical conditions also produced a lot of influence on them as a whole (p<0.001).4. Regarding job autonomy, radiological technologists were found to have been less influenced by position in metropolitan cities and by immediate seniors in the capital city (p<0.01). As a whole, however, age and job satisfaction acted as decisive factors of influence on them (p<0.001). 5. Among factors related to job burden, gender played a bigger role for radiological technologists in metropolitan cities as the kind of medical institutions did in small- and medium-sized cities. Centrally, job satisfaction and behavioral conducts exercised a great impact on them (p<0.001).6. Job stability seemed to be more immensely linked to gender and physical conditions in metropolitan cities whereas position did more in the capital city. In general, how ever, job satisfaction produced a far-reaching (p<0.001).