• Title/Summary/Keyword: medical monitoring

Search Result 1,611, Processing Time 0.025 seconds

Remote Patient Monitoring through the Internet (인터넷을 통한 원격환자 모니터링)

  • 박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.377-383
    • /
    • 2001
  • In this paper, we present an intensive patient monitoring service through the Internet, which enables medical doctors to watch their patients in a remote site, to monitor their vital signs and to give them some advices for first-aid treatment. The service consists of three service objects: Monitoring Information Service(MIS), Vital Sign Monitoring Service(VSMS) and Multimedia Consulting (MCS). Through the MIS, medical doctors can get information about the patients currently under monitoring, including their names, ages, genders, symptoms, current main complaints and current locations. The VSMS enables medical doctors to monitor in real-time patients' vital signs such as electrocardiogram (ECG), respiration, temperature, blood oxygen saturation (SpO$_{2}$), invasive blood pressure (IBP), and non-invasive blood pressure (NIBP). It also generates alarms when the patients are likely to be in a critical situation. The MCS provides a real-time multimedia desktop conferencing facility for watching patients and instructing attendants to administer some first-aid treatment. We carried out some experiments according to two different scenarios. The intensive patient monitoring service was functioning well in a 100Base-T Ethernet LAN environment.

  • PDF

Optimal Monitoring Intervals and MDA Requirements for Routine Individual Monitoring of Occupational Intakes Based on the ICRP OIR

  • Ha, Wi-Ho;Kwon, Tae-Eun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Background: The International Commission on Radiological Protection (ICRP) has recently published report series on the occupational intakes of radionuclides (OIR) for internal dosimetry of radiation workers. In this study, the optimized monitoring program including the monitoring interval and the minimum detectable activity (MDA) of major radionuclides was suggested to perform the routine individual monitoring of internal exposure based on the ICRP OIR. Materials and Methods: The derived recording levels and the critical monitoring quantities were reviewed from international standards or guidelines by the International Atomic Energy Agency (IAEA), the International Organization for Standardization (ISO), and the European Radiation Dosimetry Group (EURADOS). The OIR data viewer provided by ICRP was used to evaluate the monitoring intervals and the MDA, which are derived from the reference bioassay functions and the dose coefficients. Results and Discussion: The optimal monitoring intervals were determined taking account of two requirement conditions on the potential intake underestimation and the MDA values. The MDA requirement values of the selected radionuclides were calculated based on the committed effective dose from 0.1 mSv to 5 mSv. The optimized routine individual monitoring program was suggested including the optimal monitoring intervals and the MDA requirements. The optimal MDA values were evaluated based on the committed effective dose of 0.1 mSv. However, the MDA can be adjusted considering the practical operation of the routine individual monitoring program in the nuclear facilities. Conclusion: The monitoring intervals and the MDA as crucial factors for the routine monitoring were described to suggest the optimized routine individual monitoring program of the occupational intakes. Further study on the alpha/beta-emitting radionuclides as well as short lived gamma-emitting nuclides will be necessary in the future.

Development and Clinical Application of Central Fetal Monitoring System with Visual Maternal Monitoring function based on Personal Computer (산모 영상감시 겸용 중앙집중식 태아 전자감시 시스템의 개발 및 임상적 응용)

  • Jun, John-B.;Lee, H.C.;Yoon, H.J.;Yang, S.I.;Kim, Y.M.;Lee, I.S.;Kim, Y.T.;Kim, A.;Nam, J.H.;Mok, J.E.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.40-43
    • /
    • 1993
  • Electronic fetal monitoring system is an easier ar d usual method in various prenatal and labor period fetal surveilence methods currently in use. But there haven't been enough cases of using the central monitoring system despite the fact that the bedside fetal monitoring system have already been widely in use in Korea as an essential medical equipment item. We have developed more efficient central fetal monitoring system based on the personal computer with the visual maternal monotoring device using infrared camera which processes the signals from existing bedside fetal monitoring systems such as H/P's 8040 series. And we have performed the clinical application on 41 pregnant women and the results were satisfactory. In conclusion, more efficient and familial fetal monitoring is possible with our PC based central fetal monitoring system which provides the medical personnel with the view of a selected pregnant woman on the same screen where the electronic waveforms and data are displayed.

  • PDF

Implementation of Medical Device Integration Module for Integrated Patient Monitoring System

  • Park, Myeong-Chul;Jung, Hyon-Chel;Choi, Duk-Kyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.6
    • /
    • pp.79-86
    • /
    • 2017
  • In this paper, we implement a common module that can integrate multiple biometric information for integrated patient monitoring system. Conventional biomedical instruments have many devices attached to each patient, making it difficult to monitor abnormality signs of many patients in real time. In this paper, we propose a module for an integrated monitoring system that can perform centralized monitoring using a common module that integrates multiple measurement devices. A protocol for sending and receiving packets between the measuring device and the common module is designed, and the packets transmitted through the network are stored and managed through the integrated monitoring system and provide information to various users such as medical staff. The results of this study are expected to contribute to the management of patients and efficient medical services in hospitals.

A Study on the Cognizance of Hospital and oriental Hospital Workers for Medical Device Safety Information Monitoring (의료기기 안전성 정보 모니터링에 대한 한병병원 및 병원 종사자의 인지도 조사연구)

  • Kim, Ji Hyun;Nam, Ki Chang;Kim, Hojun;Nam, Yeon Gyo;Kim, You Jin;jo, Eun hye;Kwon, Bum Sun
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.86-93
    • /
    • 2021
  • Purpose: The purpose of this study is to find out the cognizance of medical device safety information (MDSI) monitoring in the hospital and oriental hospital workers, and the different aspect of MDSI between oriental medical devices and medical devices. Methods: The survey was performed both in the oriental medicine hospital and general hospital. The survey had 16 items; 2 items basic questions, 5 items in the awareness of MDSI, 5 items in the education of MDSI, 4 items in the necessity of defining oriental medical devices and differences between general and oriental medical devices. A total of 120 hospital worker were participated; 60 oriental medicine hospital workers and 60 general hospital workers. They had worked in the oriental medicine or general hospital associated with 'Medical Device Safety Monitoring Center, Dongguk University Ilsan Hospital' in 2019 and 2020. Results: The cognizance of MDSI was high both in oriental medicine hospital and general hospital workers and there were no significant differences between oriental medicine and general hospital workers. When we divided the hospital workers into the senior workers who had worked for over 3 years and junior workers for less than 3 years, the senior workers had higher awareness of MDSI than junior workers. However, the cognizance of education of MDSI was high which was not different between senior and junior workers. Both hospital workers thought that it was necessary to define oriental medicine device legally and the oriental medical device might have low risk and less side effect than medical device. Conclusion: The cognizance of MDSI was high and there was no significant differences between oriental medicine and general hospital workers. Because the senior hospital workers had higher recognition of MDSI, we need to provide the continuous education program for junior hospital workers. Although oriental medical device are thought to be safer than medical device, we need to have a legal definition.

Real-time monitoring of ultra-high dose rate electron beams using bremsstrahlung photons

  • Hyun Kim;Dong Hyeok Jeong;Sang Koo Kang;Manwoo Lee;Heuijin Lim;Sang Jin Lee;Kyoung Won Jang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3417-3422
    • /
    • 2023
  • Recently, as the clinically positive biological effects of ultra-high dose rate (UHDR) radiation beams have been revealed, interest in flash radiation therapy has increased. Generally, FLASH preclinical experiments are performed using UHDR electron beams generated by linear accelerators. Real-time monitoring of UHDR beams is required to deliver the correct dose to a sample. However, it is difficult to use typical transmission-type ionization chambers for primary beam monitoring because there is no suitable electrometer capable of reading high pulsed currents, and collection efficiency is drastically reduced in pulsed radiation beams with ultra-high doses. In this study, a monitoring method using bremsstrahlung photons generated by irradiation devices and a water phantom was proposed. Charges collected in an ionization chamber located at the back of a water phantom were analyzed using the bremsstrahlung tail on electron depth dose curves obtained using radiochromic films. The dose conversion factor for converting a monitored charge into a delivered dose was determined analytically for the Advanced Markus® chamber and compared with experimentally determined values. It is anticipated that the method proposed in this study can be useful for monitoring sample doses in UHDR electron beam irradiation.

Medical Information Event Monitoring System based on Sense and Respond (Sense and Respond 기반의 의료정보 이벤트 모니터링 시스템)

  • Kang, Un-Gu;Lee, Young-Ho;Kim, Si-Ra;Yoon, Young-Mi
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.8
    • /
    • pp.138-146
    • /
    • 2009
  • Recently big-sized hospitals showed their interest in medical information event monitoring system based on Sense and Respond in order to give patients in emergency a safer medical treatment. In this paper we implemented medical information event monitoring system based on Sense and Respond which stand on event and monitoring process. This system consists of event definition, event extraction, event delivery, and monitoring. It ensures real-time response by grasping and delivering medical information in real-time, and well-balanced understanding of information for hospital management by real-time tracking. Also early confrontation case by case by, event delivery make the safety of patients be secured, the efficiency of hospital can be maximized by early grasping the problems in hospital management problems.

Intraoperative Neurophysiologic Monitoring and Functional Outcome in Cerebellopontine Angle Tumor Surgery (소뇌-교각종양 수술시 수술 중 전기생리학적 신경감시에 따른 수술 후 기능적 결과)

  • Lee, Sang Koo;Park, Kwan;Park, Ik Seong;Seo, Dae Won;Uhm, Dong Ok;Nam, Do-Hyun;Lee, Jung-Il;Kim, Jong Soo;Hong, Seung Chyul;Shin, Hyung Jin;Eoh, Whan;Kim, Jong Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.6
    • /
    • pp.778-785
    • /
    • 2000
  • Objectives : Intraoperative neurophysiologic monitoring(INM) is a well known useful method to reduce intraoperative neurological complications during neurosurgical procedures. Furthermore, INM is required in most cerebellopontine angle(CPA) surgery because cranial nerves or brain stem injuries can result in serious complications. Object of this study is to the correlation between the changes of intraoperative monitoring modalities during cerebellopontine angle tumor surgery and post-operative functional outcomes in auditory and facial functions. Material and Methods : Fifty-seven patients who underwent intraoperative neurophysiologic monitoring during CPA tumor surgery were retrospectively reviewed. Their lesions were as follows ; vestibular schwannomas in 42, other cranial nerve schwannomas in seven, meningiomas in five and cysts in three cases. Pre- and postoperative audiologic examinations and facial nerve function tests were performed in all patients. Intraoperative neurophysiologic monitoring modalities includes brainstem auditory evoked potentials(BAEP) and facial electromyographies(EMG). We compared the events of INM during CPA tumor surgeries with the outcomes of auditory and facial nerve functions. Results : The subjects who had abnormal changes during CPA tumor surgery were twenty cases with BAEP changes and facial EMG changes in twenty one cases. The changes of intraoperative neurophysiologic monitoring did not always result in poor functional outcomes. However, most predictable intraoperative monitoring changes were wave III-V complex losses in BAEP and continuous neurotonic activities in facial EMG. Conclusion : These results indicate that intraoperative neurophysiologic monitoring in CPA tumor surgery usually provide predictive value for postoperative functional outcomes.

  • PDF

Development of a knowledge-based medical expert system to infer supportive treatment suggestions for pediatric patients

  • Ertugrul, Duygu Celik;Ulusoy, Ali Hakan
    • ETRI Journal
    • /
    • v.41 no.4
    • /
    • pp.515-527
    • /
    • 2019
  • This paper discusses the design, implementation, and potential use of an ontology-based mobile pediatric consultation and monitoring system, which is a smart healthcare expert system for pediatric patients. The proposed system provides remote consultation and monitoring of pediatric patients during their illness at places distant from medical service areas. The system not only shares instant medical data with a pediatrician but also examines the data as a smart medical assistant to detect any emergency situation. In addition, it uses an inference engine to infer instant suggestions for performing certain initial medical treatment steps when necessary. The applied methodologies and main technical contributions have three aspects: (a) pediatric consultation and monitoring ontology, (b) semantic Web rule knowledge base, and (c) inference engine. Two case studies with real pediatric patients are provided and discussed. The reported results of the applied case studies are promising, and they demonstrate the applicability, effectiveness, and efficiency of the proposed approach.

Basic Techniques of Intraoperative Neurophysiological Monitoring

  • Park, Sang-Ku;Hyun, Soon-Chul;Lim, Sung-Hyuk;Park, Chan-Woo;Park, Jin-Woo;Kim, Dong-Jun;Choi, Wan-Soo;Kim, Gi-Bong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.2
    • /
    • pp.77-85
    • /
    • 2013
  • Intraoperative Neurophysiological Monitoring (INM) is very useful in monitoring the motorsensory pathway and vascular circulation system during intraspinal, or intracranial neurosurgery. Brainstem Auditory Evoked Potentials (BAEPs) are for detecting the problems along the auditory pathways including, the eighth cranial nerve and brainstem. Motor Evoked Potentials (MEPs) is a useful adjunct to conventional monitoring of Somato-sensory Evoked Potentials (SEPs) during surgery. Visual Evoked Potentials (VEPs) has been regarded as having limited significance for the preservation of visual function during neurosurgical procedures. In this paper, we propose that the most appropriate averaging of the number of inspections in the inspection of each used in the operative field, is good and efficient, functionally.

  • PDF