• 제목/요약/키워드: medical images

검색결과 2,805건 처리시간 0.034초

An X-ray Image Panorama System Using Robust Feature Matching and Per ception-Based Image Enhancement

  • Wang, Weiwei;Gwun, Oubong
    • 한국멀티미디어학회논문지
    • /
    • 제15권5호
    • /
    • pp.569-576
    • /
    • 2012
  • This paper presents an x-ray medical image panorama system which can overcome the smallness of the images that exist on a source computer during remote medical processing. In the system, after the standard medical image format DICOM is converted to the PC standard image format, a MSR algorithm is used to enhance X-ray images of low quality. Then SURF and Multi-band blending are applied to generate a panoramic image. Also, this paper evaluates the proposed SURF based system through the average gray value error and image quality criterion with X-ray image data by comparing with a SIFT based system. The results show that the proposed system is superior to SIFT based system in image quality.

웨이블릿변환을 이용한 무손실에 가까운 의료영상압축 (Near Lossless Medical Image Compression using Wavelet Transform)

  • 윤기병;안창범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.113-116
    • /
    • 1995
  • Medical image compression using the wavelet transform has been tried. Due to the flexibility in representing nonstationary image signal in both time and frequency domains and its ability to adapt human visual characteristics, wavelet transform has unique advantage in images compression. In the proposed wavelet compression original image is decomposed into multi-scale bands. Different scale factors are employed in the quantization of wavelet decomposed images in different bands. For the lowest band, a predictor is designed and error signal is entropy coded. For high scale bands, runlength coding for toro run is used with Huffman coding. From simulation with magnetic resonance images($256\times256$ size, 256 graylevels) the proposed algorithm is superior to the JPEG by more than 2.5 dB in near lossless compression (CR = 8 - 10).

  • PDF

SNR and PSNR measurements and analysis of median filtering for the removal of impulse noise from CR imaging

  • Hong, Seong-Il;Dong, Kyung-Rae;Ryu, Young-Hwan
    • International Journal of Contents
    • /
    • 제5권4호
    • /
    • pp.7-12
    • /
    • 2009
  • In this paper, the authors showed that the removal of impulse noise in CR images was implemented using variety of median filters and SNR/PSNR measurements. They used three kinds of medical images-hand, skull, and knee- for experimental results. But the noise in CR image was only the impulse noise. In real medical image, the noise of an image would be very different type. Therefore. the lack of experimental results using different noise in CR images is one flaw.

웨이블렛 변환 기반의 특징 검출을 이용한 의료영상 검색 (Medical Image Retrieval Using Feature Extraction Based on Wavelet Transform)

  • 이흥석;마경윤;안영복
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.321-322
    • /
    • 1998
  • In this paper, a medical images retrieval method using feature extraction based on wavelet transform is proposed. We used energy of coefficients which is represented by wavelet transform. The proposed retrieval algorithm is comprised of the two retrieval. At first, we make a energy map for wavelet coefficient of a query image and then compare is to one of db image. And then we use an edge information of the query image to retrieve the images selected at the first retrieval once more. Consequently some retrieved images are displayed on screen.

  • PDF

CT 이미지로부터 3차원 모델 생성을 위한 contour 기반 알고리즘 (Contour based Algorithms for Generating 3D Models from CT Images)

  • 류재헌;김현수;이관행
    • 한국정밀공학회지
    • /
    • 제20권4호
    • /
    • pp.174-182
    • /
    • 2003
  • Recently, medical imaging has taken interest on CAD based solution for anatomical part fabrication or finite element analysis of human body. In principle, contours representing object boundary are obtained through image processing techniques. Surface models are then approximated by a skinning method. For this, various methods should be applied to medical images and contours. The major bottleneck of the reconstruction is to remove shape inconsistency between contours and to generate the branching surface. In order to solve these problems, bi-directional smoothing and the composite contour generation method are proposed. Bi-directional smoothing has advantage of removing the shape inconsistency between contours and minimizing shrinkage effect with a large number of iterations. The composite contour by the proposed method ensures smooth transition in branching region.

Perceptually Enhanced Matching을 사용한 삼차원 의학영상 Fractal Coding (Three Dimensional Fractal Coding of Medical Images with Perceptually Enhanced Matching)

  • 신흥식;안창범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.131-134
    • /
    • 1995
  • A three dimensional fractal coding with a perceptually enhanced matching is proposed. Since most of medical images (e.g. computed tomography or magnetic resonance image) have three dimensional character, the searching region is extended to adjacent slices. For perceptually enhanced matching, a high frequency booster filter is used for prefiltering of the original image, and the least mean square error matching is applied to this edge enhanced image rather than the original image. From the simulation with the magnetic resonance images ($255{\times}255$, 8bits/pixel). the proposed algorithm provides excellent image quality with compression rations higher than 10. Compared to existing fractal coding the algorithm also provides better subjective image quality with higher compression ratio.

  • PDF

Geometric calibration of a computed laminography system for high-magnification nondestructive test imaging

  • Chae, Seung-Hoon;Son, Kihong;Lee, Sooyeul
    • ETRI Journal
    • /
    • 제44권5호
    • /
    • pp.816-825
    • /
    • 2022
  • Nondestructive testing, which can monitor a product's interior without disassembly, is becoming increasingly essential for industrial inspection. Computed laminography (CL) is widely used in this application, as it can reconstruct a product, such as a printed circuit board, into a three-dimensional (3D) high-magnification image using X-rays. However, such high-magnification scanning environments can be affected by minute vibrations of the CL device, which can generate motion artifacts in the 3D reconstructed image. Since such vibrations are irregular, geometric corrections must be performed at every scan. In this paper, we propose a geometry calibration method that can correct the geometric information of CL scans based on the image without using geometry calibration phantoms. The proposed method compares the projection and digitally reconstructed radiography images to measure the geometric error. To validate the proposed method, we used both numerical phantom images at various magnifications and images obtained from real industrial CL equipment. The experiment results confirmed that sharpness and contrast-to-noise ratio (CNR) were improved.

Optimal Phase of Dynamic Computed Tomography for Reliable Size Measurement of Metastatic Neuroendocrine Tumors of the Liver: Comparison between Pre- and Post-Contrast Phases

  • Huh, Jimi;Park, Jisuk;Kim, Kyung Won;Kim, Hyoung Jung;Lee, Jong Seok;Lee, Jong Hwa;Jeong, Yoong Ki;Shinagare, Atul B.;Ramaiya, Nikhil H.
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1066-1076
    • /
    • 2018
  • Objective: The reliability of size measurements of liver metastases from neuroendocrine tumors (NETs) on contrast-enhanced computed tomography (CT) phases made by different readers may be hampered due to transient, variable rim enhancement in arterial phase (AP) or portal venous phase (PVP) images. We aimed to assess the reliability of tumor size measurements in pre- and post-contrast scans. Materials and Methods: The study coordinator selected target lesions according to Response Evaluation Criteria in Solid Tumors 1.1 guidelines in 44 consecutive patients with pathologically confirmed NET liver metastases. Two blinded readers measured the longest diameters of target lesions on pre-contrast, AP, and PVP images twice with a 4-week interval. Inter- and intra-observer agreements were evaluated using Bland-Altman plots and 95% limit of agreement (LOA) calculations. Results: Of the 79 target lesions (approximate mean size of 3 cm), 45 showed rim enhancement. Inter-observer agreement assessed based on LOA was highest in pre-contrast CT images (-6.1-5.7 mm), followed by PVP (-7.9-7.1 mm) and AP (-8.5-7.4 mm) images. Intra-observer agreement showed the same trend: -2.8-2.9 mm and -2.9-2.9 mm for readers 1 and 2, respectively, on pre-contrast CT, -2.8-2.9 mm and -3.0-3.2 mm, respectively, on PVP, and -3.2-4.2 mm and -3.4-3.2 mm, respectively, on AP images. Mean tumor diameters differed significantly among the phases in the following increasing order: pre-contrast CT, PVP, and AP images. Conclusion: There was better inter- and intra-observer agreement in size measurements of NET liver metastases on pre-contrast scans than on AP and PVP scans. Pre-contrast CT may be the optimal for measuring NET liver metastases if its accuracy is proven.

폐암 환자의 정위체부방사선치료 시 기준선 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질 및 유용성 평가 (Image quality and usefulness evaluaton of 3D-CBCT and Gated-CBCT according to baseline changes for SBRT of Lung Cancer)

  • 한국희;신충훈;이충환;유순미;박자람;김진수;윤인하
    • 대한방사선치료학회지
    • /
    • 제35권
    • /
    • pp.41-51
    • /
    • 2023
  • 목 적: 본 연구는 폐암 환자의 정위체부방사선치료 시(Stereotactic Body Radiation Therapy, SBRT) 기준선(Baseline) 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질(Image quality)을 비교 분석하여 호흡에 따른 움직임의 보정에 유용한 CBCT 촬영 방법을 찾고자 한다. 대상 및 방법: QUASARTM(Modus Medical Devices Inc, Canada) 팬텀에 지름이 3 cm인 고체 종양 물질(Solid Tumor)을 삽입하여 팬텀의 속도를 주기 3 sec, 최대 진폭 20 mm 로 4DCT(4-Dimentional Computed-Tomography)를 촬영하였다. 전산화 치료계획시스템 EclipseTM을 이용하여 고체 종양 물질에 육안적 종양용적(Gross Target Volume, GTV)을 윤곽 묘사하였다. Truebeam STxTM을 이용해 4DCT 촬영 시와 동일하게 설정한 후, 기준선 변화가 1 mm, 3 mm, 5 mm인 호흡 패턴을 팬텀에 입력하여 3D-CBCT(Spotlight, Full)와 Gated-CBCT(Spotlight, Full) 영상을 5회 반복하여 획득하였다. 획득된 영상을 4DCT 영상을 기준으로 신호대잡음비(Signal-to-Noise Ratio, SNR), 대조대잡음비(Contrast-to-Noise Ratio, CNR), 종양 체적 길이(Tumor Volume Length) 및 모션 블러링 비(Motion Blurring Ratio, MBR)를 측정하여 비교하였다. 결 과: Spotlight Gated-CBCT 영상이 기준선 변화에 따른 신호대잡음비가 평균 13.30±0.10%, 대조대잡음비가 평균 7.78±0.16%, 종양 체적 길이가 평균 3.55 ± 0.17%, 모션 블러링 비가 평균 1.18 ± 0.06%로 Spotlight 3D-CBCT보다 우수한 값을 보였다. 또한, Full Gated-CBCT 영상이 기준선 변화에 따른 신호대잡음비가 평균 12.80 ± 0.11%, 대조대잡음비가 평균 7.60 ± 0.11%, 종양 체적 길이가 평균 3.54 ± 0.16%, 모션 블러링 비가 평균 1.18 ± 0.05%로 Full 3D-CBCT보다 우수한 값을 보였다. 결 론: 3D-CBCT 촬영 영상과 비교하여 Gated-CBCT 촬영 영상이 기준선 변화에 따른 영상 품질이 우수한 값을 보였으며, 호흡으로 인한 모션 블러링 인공물(Motion Blurring Artifacts)의 영향이 적은 것을 확인했다. 따라서 단기간에 고선량을 전달하는 폐암의 정위체부방사선치료 시 불규칙한 호흡으로 인한 기준선 변화가 발생하는 경우 Gated-CBCT를 이용해 영상유도(Image Guide)를 하는 것이 유용하다고 판단된다.

  • PDF

공유 전자의무기록을 위한 MFER과 HL7 표준 적용 (Adoption of MFER and HL7 Standard for Shared Electronic Medical Record)

  • 김화선;박춘복;홍해숙;조훈
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.501-506
    • /
    • 2008
  • Medical environments incorporate complex and integrated data networks to transfer vast amounts of patient information, such as images, waveforms, and other digital data. To assure interoperability of images, waveforms and patient data, health level seven(HL7) was developed as an international standard to facilitate the communication and storage of medical data. We also adopted medical waveform description format encoding rule(MFER) standard for encoding waveform biosignal such as ECG, EEG and so on. And, the study converted a broad domain of clinical data on patients, including MFER, into a HL7 message, and saved them in a clinical database in hospital. According to results obtained in the test environment, it was possible to acquire the same HL7 message and biosignal data as ones acquired during transmission. Through this study, we might conclude that the proposed system can be a promising model for electronic medical record system in u-healthcare environment.