The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.

TENSILE STRENGTH OF LASER WELDED-TITANIUM AND GOLD ALLOYS (티타늄과 금합금의 레이저 용접부의 인장강도)

  • Song, Yun-Gwan;Ha, Il-Soo;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.200-213
    • /
    • 2000
  • Lasers have given dentistry a new rapid, economic, and accurate technique for metal joining. Although laser welding has been recommended as an accurate technique, there are some limitations with this technique. For example, the two joining surfaces must have a tight-fitting contact, which may be difficult to achieve in some situations. The tensile samples used for this study were made from a custom-made pure titanium and type III gold alloy plates. 27 of 33 specimens were sectioned perpendicular to their long axis with a carborundum disk and water coolant. Six specimens remained and served as the control group. A group of 6 specimens was posed as butt joints in custom parallel positioning device with a feeler gauge at each of three gaps : 0.00, 0.25. and 0.50mm. All specimens were then machined to produce a uniform cross-sectional dimension, none of the specimens was subjected to any subsequent form of heat treatment. Scanning electron microscopy was performed on representative tested specimens at fractured surfaces in both the parent metal and the weld. Vickers hardness was measured at the center of the welds with a micropenetrometer using a force of 300gm for 15 seconds. Measurement was made at approximately $200{\mu}m\;and\;500{\mu}m$ deep from each surface. One-way analysis of variance (ANOVA) and Scheffe's test was calculated to detect differences between groups. The purpose of this study is to compare the strength and properties of the joint achieved at various butt Joint gaps by the laser welding of type III gold alloy and pure titanium tensile specimens in an argon atmosphere. The results of this study were as follows : 1. When indexing and welding pure titanium, there was no decrease in ultimate tensile strength as compared with the unsectioned alloys for indexing gaps of 0.00 to 0.50mm, although with increasing gap size may come increased distortion (p>0.05). 2. When indexing and welding type III gold alloy, there were significant differences in ultimate tensile strength among groups with weld gaps of 0.00mm, 0.25 and 0.50mm, and the control group. Group with butt contact without weld gap demonstrated a significant higher ultimate tensile strength than groups with weld gaps of 0.25 and 0.50mm (p<0.05). 3. When indexing and welding the different metal combination of type III gold alloy and pure titanium, there were significant differences in ultimate tensile strength between groups with weld gaps of 0.00, 0.25, and 0.50mm. However, the mechanical properties of the welded joint would become too brittle to be acceptable clinically (p<0.05). 4. The presence of large pores in the laser welded joint appears to be the most important factor in controlling the tensile strength of the weld in both pure titanium and type III gold alloy.

  • PDF

Cognitive Perception of an Eco-friendly Public Transportation : Using Principal Component Analysis (친환경 대중교통 수단에 대한 인지적 특성 비교 분석 : 주성분분석을 활용하여)

  • Kwon, Yeongmin;Kim, Suji;Byun, Jihye
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.1
    • /
    • pp.71-82
    • /
    • 2020
  • The existing transportation system, which is based on internal combustion engines, is rapidly being converted to electrification. Thus, eco-friendly public transportation with high transportation efficiency will continue to spread throughout the market in the near future. The purpose of this study is to compare and analyze the cognitive characteristics of passengers redgarding the technical and social factors of various public transportation means to help a successful introduction of eco-friendly public transit. Through a survey questionnaire (N=485), seven factors of seven transportation modes were evaluated and analyzed using principal component analysis. As a result, it is confirmed that potential passengers have high expectations for the eco-friendliness and city image of the eco-friendly buses. Also, it is confirmed that eco-friendly buses are superior in cleanliness and ride comfort than diesel buses. Given the study's results, this study identifies the cognitive characteristics of passengers regarding eco-friendly public transportation. We hope that these results will be used as basic information for image positioning and improved service with the use of eco-friendly transportation.

MR Technology to 4T

  • Vaughan, Thomas
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.103-105
    • /
    • 2003
  • After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.

  • PDF

GPS L1, L2C Signal Acquisition Performance of GPS Software Receiver with respect to Pseudolite Pulsing Scheme (의사위성의 펄싱 방법에 대한 GPS L2C 신호획득 성 소능프분트석웨어 수신기의 L1, L2C 신호획득 성능분석)

  • Kwon, Keum-Cheol;Yand, Cheol-Kwan;Shim, Duk-Sun;Chung, Tae-Sang;Kee, Chand-Don
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.1
    • /
    • pp.16-26
    • /
    • 2012
  • Pseudolites are ground-based transmitters that can be configured to emit GPS-like signals for enhancing the GPS by providing increased accuracy, integrity, and availability. However, a pseudolite (PL) can interfere with GPS satellite signals while it is transmitting or cause saturation to automatic gain control circuit. To solve these problems pulsing scheme is used, which transmits PL signal during a short period of time. In this paper the effect of the number of PL and pulsing scheme on the software GPS L1 and L2C signal acquisition performance is studied for the three pulsing schemes such as static pulsing, sweep pulsing, and pseudo random pulsing. For GPS L1 signal, static pulsing shows the best signal acquisition and tracking performance with one PL, and random pulsing shows the best performance with more than or equal to two PLs. For GPS L2C signal, all three pulsing schemes show the similar signal acquisition and tracking performance, but static pulsing shows a little better performance. For GPS L1 and L2C signals, software GPS receivers can do positioning with up to three PLs.

An Image Management System of Frame Unit on a Hand-held Device Environments (휴대장치 환경을 위한 프레임 단위의 영상 데이터 관리 시스템)

  • Choi, Jun-Hyeog;Yoon, Kyung-Bae;Han, Seung-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.7
    • /
    • pp.29-36
    • /
    • 2008
  • This paper proposes algorithm for the system that can search for an image of a frame unit, and we implement it. A system already inserts in images after generating the cord that mechanical decoding and identification are possible. We are independent of an external noise in a frame unit, and a system to propose at these papers can search for an image recorded by search condition to include recording date, recording time, a recording place or filming course etc. This system is composed by image insertion wealth to insert data to an image to data image code generation wealth, a frame generating data image code you apply a code generation rule to be fixed in order to express to a price to have continued like data entry wealth, GPS locator values and direction price receiving an image signal, image decoding signals and an image search signal to include search condition, and to have continuity from users each of an image. Also, image decoding we decipher about the noise that was already added from the outsides in a telerecording process, a copy process or storage processes inserted in images by real time, and searching image information by search condition. Consequently we implement decoder, and provide the early system that you use, and we easily insert data code among images. and we can search. and maximization can get precision regarding an image search and use satisfaction as we use algorithm to propose at these papers.

  • PDF

Design of a Compact GPS/MEMS IMU Integrated Navigation Receiver Module for High Dynamic Environment (고기동 환경에 적용 가능한 소형 GPS/MEMS IMU 통합항법 수신모듈 설계)

  • Jeong, Koo-yong;Park, Dae-young;Kim, Seong-min;Lee, Jong-hyuk
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.1
    • /
    • pp.68-77
    • /
    • 2021
  • In this paper, a GPS/MEMS IMU integrated navigation receiver module capable of operating in a high dynamic environment is designed and fabricated, and the results is confirmed. The designed module is composed of RF receiver unit, inertial measurement unit, signal processing unit, correlator, and navigation S/W. The RF receiver performs the functions of low noise amplification, frequency conversion, filtering, and automatic gain control. The inertial measurement unit collects measurement data from a MEMS class IMU applied with a 3-axis gyroscope, accelerometer, and geomagnetic sensor. In addition, it provides an interface to transmit to the navigation S/W. The signal processing unit and the correlator is implemented with FPGA logic to perform filtering and corrrelation value calculation. Navigation S/W is implemented using the internal CPU of the FPGA. The size of the manufactured module is 95.0×85.0×.12.5mm, the weight is 110g, and the navigation accuracy performance within the specification is confirmed in an environment of 1200m/s and acceleration of 10g.

One-Dimensional Consolidation Simulation of Kaolinte using Geotechnical Online Testing Method (온라인 실험을 이용한 카올리나이트 점토의 일차원 압밀 시뮬레이션)

  • Kwon, Youngcheul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4C
    • /
    • pp.247-254
    • /
    • 2006
  • Online testing method is one of the numerical experiment methods using experimental information for a numerical analysis directly. The method has an advantage in that analysis can be conducted without using an idealized mechanical model, because mechanical properties are updated from element test for a numerical analysis in real time. The online testing method has mainly been used for the geotechnical seismic engineering, whose major target is sand. A testing method that may be applied to a consolidation problem has recently been developed and laboratory and field verifications have been tried. Although related research thus far has mainly used a method to update average reaction for a numerical analysis by positioning an element tests at the center of a consolidation layer, a weakness that accuracy of the analysis can be impaired as the thickness of the consolidation layer becomes more thicker has been pointed out regarding the method. To clarify the effectiveness and possible analysis scope of the online testing method in relation to the consolidation problem, we need to review the results by applying experiment conditions that may completely exclude such a factor. This research reviewed the results of the online consolidation test in terms of reproduction of the consolidation settlement and the dissipation of excess pore water pressure of a clay specimen by comparing the results of an online consolidation test and a separated-type consolidation test carried out under the same conditions. As a result, the online consolidation test reproduced the change of compressibility according effective stress of clay without a huge contradiction. In terms of the dissipation rate of excess pore water pressure, however, the online consolidation test was a little faster. In conclusion, experiment procedure needs to improve in a direction that hydraulic conductivity can be updated in real time so as to more precisely predict the dissipation of excess pore water pressure. Further research or improvement should be carried out with regard to the consolidation settlement after the end of the dissipation of excess pore water pressure.