• 제목/요약/키워드: mechanical performance test

검색결과 2,616건 처리시간 0.03초

반복 충격이 유리섬유 강화 폴리우레탄 폼의 기계적 성능에 미치는 영향 (Effect of Repetitive Impacts on the Mechanical Behavior of Glass Fiber-reinforced Polyurethane Foam)

  • 김명성;김정현;김슬기;이제명
    • 한국해양공학회지
    • /
    • 제33권1호
    • /
    • pp.85-91
    • /
    • 2019
  • In a cryogenic storage structure, the insulation system is in an environment in which fluid impact loads occur throughout the lifetime of the structure. In this study, we investigated the effect of repetitive impact loading on the mechanical performance of glass fiber-reinforced polyurethane foam. The repeated impact loading test was conducted in accordance with the required impact energy and the required number of repetitive impacts. The impact behavior of glass fiber-reinforced polyurethane foam was analyzed in terms of stress and displacement. After the impact test, the specimen was subjected to a compression test to evaluate its mechanical performance. We analyzed the critical impact energy that affected mechanical performance. For the impact conditions that were tested, the compressive strength and elastic modulus of the polyurethane foam can be degraded significantly.

배전용애자의 경년시험방법과 폴리머애자의 개발 동향 (The aging test method of insulator and development prospect of polymer insulator)

  • 송일근;김상준;김주용;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1791-1793
    • /
    • 1996
  • This paper describes Thermal-Mechanical performance and Ultimate Mechanical-Strength test for the purpose of aging analysis of suspension insulator. The temperature difference of insulator surface according to the aging of suspension insulator brought out about $2^{\circ}C$ to $7-8^{\circ}C$ difference comparing with the atmospheric temperature. Quality standard and Mechanical-Strength of used suspension insulator deteriorate more remarkably than that of new suspension insulator. It is required that Thermal-Mechanical performance test standard be revised in the future. And it is described about the development prospect of polymer insulators

  • PDF

열교환기에 대한 스케일 완화장치의 성능평가 (Performance Evaluation of Scale Mitigation Unit for Heat Exchangers)

  • 모정하;신상철;김경우
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1149-1156
    • /
    • 2001
  • The objective of the present study is to investigate the performance of electronic scale mitigation unit(ESMU), which reduces the amount of scale in a heat exchanger. The circular tube with diameter of 19mm and plate-and-frame heat exchangers with 20 thermal plates were used for the tests. In order to accelerate the rate of scale in a laboratory test, artificial hard water of 1000ppm(as CaCO$_3$) was recirculated at a flow rate of 5 lpm, 7 lpm, and 9 lpm throughout the tests. The effect of ESMU on the scale thickness and overall heat transfer coefficients was examined. The test results showed that the ESMU could reduce the scale deposits even in the acceleated test.

외산 154kV NGK 노후애자의 전기적 성능 평가 (A Study on the Electric Performance of NGK Porcelain Insulators for long period use in 154kV Transmission Line)

  • 최인혁;박현민;원경배;강동훈;신구용;김영홍;김민주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.426-428
    • /
    • 2015
  • The NGK suspension insulators are subjected in harsh environments in service above 40 years long time. The long term reliability of the insulators is required for both mechanical and electrical performances. This study describes some electrical performances according to KEPCO-standard. There was fail in electrical and mechanical performance test such as galvanizing, low-frequence wet flashover voltage, puncture and combine mechanical & electrical strength test. The NGK suspension insulators of 1968 were shown lower electrical and mechanical performance than those of 1979.

  • PDF

Development of Waterproof Jacket Materials for Power Cables

  • Han, Yong-Huei;Jung, Jong-Wook;Kwon, Tae-Ho;Song, Hyun-Seok;Koo, Kyo-Sun;Han, Byung-Sung
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권4호
    • /
    • pp.146-154
    • /
    • 2003
  • This paper describes various characteristics of the new compounds for cable jackets and model cables advanced in waterproof performance in order to essentially solve the problems of underground (URD) distribution class power cable failures. Several compounds were manufactured by the inclusion of additives to base resins available in Korea and tested for basic property, mechanical and electrical characteristics. Two model cables were created by using the compounds determined in the test as being the most appropriate for new structured model cable jacket material. The waterproof performance and mechanical strength of the new cable jackets were verified by applicable tests. As a result, MDPE and LLDPE compounds were superior as cable jackets in both mechanical and electrical characteristic aspects when compared with conventional PVC. In addition, the model cables composed of the new compounds based on MDPE showed good quality results in the water permeability test.

Long-term Mechanical Behavior of CFRP-strengthened Steel Members for a Truss Tower

  • Nakamoto, Daiki;Yoresta, Fengky Satria;Matsui, Takayoshi;Mieda, Genki;Matsuno, Kazunari;Matsumoto, Yukihiro
    • 국제초고층학회논문집
    • /
    • 제9권4호
    • /
    • pp.343-349
    • /
    • 2020
  • This research aimed to clarify the long-term mechanical performance of a steel truss member strengthened by a carbon fiber-reinforced polymer (CFRP) without protective coating through exposure testing. Strengthening and repair methods using CFRP have been developed in recent years; however, there is a lack of durability research for CFRP-strengthened members, especially mechanical performance investigation according to actual exposure testing. In this study, 10 CFRP-strengthening steel specimens were created in 2015, and elastic bending tests were conducted biannually. Eventually, although resin loss occurred due to environmental effects, the mechanical performance of CFRP-strengthened steel was not degraded, and we propose a calculation method of bending stiffness to evaluate the lower value of stiffness for design.

ATC Test Bench 개발 및 성능평가에 관한 연구 (A Study on the Development and Performance Evaluation of an ATC Test Bench)

  • 김재현;최준영;이춘만
    • 한국정밀공학회지
    • /
    • 제29권5호
    • /
    • pp.489-493
    • /
    • 2012
  • Automatic tool changers(ATCs) store tools used in a machining center to its magazine and changes the tools automatically. Tools of machine centers are changed and then precisely equipped to spindle system by the ATC. Therefore, the stability and reliability of the ATC is very important. But, there is lack of development and evaluation on basic performance and vibration of the ATCs. So, in this study, a BT40 ATC test bench was developed to verify stability and reliability of BT40 ATCs.

유연 기판과 전극 사이의 접합력이 전극의 내구성에 미치는 영향 (Effect of Adhesion Strength Between Flexible Substrates and Electrodes on the Durability of Electrodes)

  • 임도연;김병준;김건휘;안태창
    • 센서학회지
    • /
    • 제33권2호
    • /
    • pp.86-92
    • /
    • 2024
  • Flexible electronic devices are exposed to repeated mechanical deformation; therefore, electrode performance is an important element. Recently, a new technology has been developed to improve the adhesion strength between polymer substrates and metal thin films through the cross-linking reaction of bovine serum albumin (BSA) bioconjugation proteins; however, additional performance evaluation as an electrode is necessary. Therefore, in this study, we investigated the effect of adhesive strength between a flexible substrate and a metal thin film on the performance of a flexible electrode. Cracks and changes in the electrical resistance of the electrode surface were observed through outer bending fatigue tests and tensile tests. As a result of a bending fatigue test of 50,000 cycles and a tensile test at 10% strain, the change in the electrical resistance of the flexible electrode with a high adhesion strength was less than 40%, and only a few microcracks were formed on the surface; thus, the electrical performance did not significantly deteriorate. Through this study, the relationship between the adhesion strength and electrical performance was identified. This study will provide useful information for analyzing the performance of flexible electrodes in the commercialization of flexible electronic devices in the future.

동적기계분석장치를 이용한 탄소섬유/에폭시 복합재의 장기 성능 예측 (Long-Term Performance Prediction of Carbon Fiber Reinforced Composites Using Dynamic Mechanical Analyzer)

  • 차재호;윤성호
    • Composites Research
    • /
    • 제32권1호
    • /
    • pp.78-84
    • /
    • 2019
  • 본 연구에서는 동적기계분석장치(dynamic mechanical analysis, DMA)와 시간-온도 중첩법(time-temperature superposition, TTS)을 이용하여 탄소섬유/에폭시 복합재의 장기 성능을 예측하고자 하였다. 이를 위해 단일 진동수 시험, 다중 진동수 시험, 크리프 TTS 시험을 수행하였다. 단일 진동수(single-frequency) 시험과 다중 진동수(multi-frequency) 시험에서는 $-30^{\circ}C$에서 $240^{\circ}C$까지 $2^{\circ}C/min$로 온도를 상승시키면서 $20{\mu}m$ 진폭의 사인(sine) 파형의 하중을 가하였으며 다중 진동수 시험에 적용된 진동수는 0.316, 1, 3.16, 10, 31.6 Hz이다. 크리프 TTS 시험에서는 $-30^{\circ}C$에서 $230^{\circ}C$까지 $10^{\circ}C$마다 15 MPa의 응력을 10분 동안 가하였다. 단일 진동수 시험을 통해 유리전이온도를 구하였으며 다중 진동수 시험을 통해 진동수 별 유리전이온도에서 활성화 에너지와 온도 별 저장탄성계수 선도를 구하였다. 또한 아레니우스 식(Arrhenius equation)을 통해 얻은 이동 인자를 적용하여 기준 온도에 대한 마스터 선도를 얻었다. 또한 크리프 TTS 시험을 통해서는 크리프 컴플라이언스 선도를 구하고 직접 이동 기법을 이용하여 구한 이동 인자를 적용하여 기준 온도에 대한 마스터 선도도 얻었다. 이와 같은 과정을 통해 얻은 마스터 선도를 이용하면 주어진 환경 조건에 대한 탄소섬유강화 복합재의 장기 성능을 예측할 수 있다.

In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.