• 제목/요약/키워드: mechanical device

검색결과 2,854건 처리시간 0.041초

티타늄과 금합금의 레이저 용접부의 인장강도 (TENSILE STRENGTH OF LASER WELDED-TITANIUM AND GOLD ALLOYS)

  • 송윤관;송광엽;하일수
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.200-213
    • /
    • 2000
  • Lasers have given dentistry a new rapid, economic, and accurate technique for metal joining. Although laser welding has been recommended as an accurate technique, there are some limitations with this technique. For example, the two joining surfaces must have a tight-fitting contact, which may be difficult to achieve in some situations. The tensile samples used for this study were made from a custom-made pure titanium and type III gold alloy plates. 27 of 33 specimens were sectioned perpendicular to their long axis with a carborundum disk and water coolant. Six specimens remained and served as the control group. A group of 6 specimens was posed as butt joints in custom parallel positioning device with a feeler gauge at each of three gaps : 0.00, 0.25. and 0.50mm. All specimens were then machined to produce a uniform cross-sectional dimension, none of the specimens was subjected to any subsequent form of heat treatment. Scanning electron microscopy was performed on representative tested specimens at fractured surfaces in both the parent metal and the weld. Vickers hardness was measured at the center of the welds with a micropenetrometer using a force of 300gm for 15 seconds. Measurement was made at approximately $200{\mu}m\;and\;500{\mu}m$ deep from each surface. One-way analysis of variance (ANOVA) and Scheffe's test was calculated to detect differences between groups. The purpose of this study is to compare the strength and properties of the joint achieved at various butt Joint gaps by the laser welding of type III gold alloy and pure titanium tensile specimens in an argon atmosphere. The results of this study were as follows : 1. When indexing and welding pure titanium, there was no decrease in ultimate tensile strength as compared with the unsectioned alloys for indexing gaps of 0.00 to 0.50mm, although with increasing gap size may come increased distortion (p>0.05). 2. When indexing and welding type III gold alloy, there were significant differences in ultimate tensile strength among groups with weld gaps of 0.00mm, 0.25 and 0.50mm, and the control group. Group with butt contact without weld gap demonstrated a significant higher ultimate tensile strength than groups with weld gaps of 0.25 and 0.50mm (p<0.05). 3. When indexing and welding the different metal combination of type III gold alloy and pure titanium, there were significant differences in ultimate tensile strength between groups with weld gaps of 0.00, 0.25, and 0.50mm. However, the mechanical properties of the welded joint would become too brittle to be acceptable clinically (p<0.05). 4. The presence of large pores in the laser welded joint appears to be the most important factor in controlling the tensile strength of the weld in both pure titanium and type III gold alloy.

  • PDF

Dose Verification of Intensity Modulated Radiation Therapy with Beam Intensity Scanner System

  • Vahc, Young-Woo;Park, Kwangyl;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.248-251
    • /
    • 2002
  • The intensity modulated radiation therapy (IMRT) with a multileaf collimator (MLC) requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC during radiation treatment of patients. Patient dose verification is clinically one of the most important parts in the treatment delivery of the radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to the target helps to verify patient dose and to determine the physical characteristics of beams used in IMRT. A new method is presented for the pretreatment dosimetric verification of two dimensional distributions of photon intensity by means of Beam Intensity Scanner System (BISS) as a radiation detector with a custom-made software for dose calculation of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The BISS reproduces 3D- relative dose distribution from the digitized fluoroscopic signals obtained by digital video camera-based scintillator(DVCS) device in the IMRT. For the intensity modulated beams (IMBs), the calculations of absorbed dose are performed in absolute beam fluence profiles which are used for calculation of the patient dose distribution. The 3D-dose profiles of the IMBs with the BISS were demonstrated by relative measurements of photon beams and shown good agreement with radiographic film. The mechanical and dosimetric properties of the collimating of dynamic and/or step MLC system alter the generated intensity. This is mostly due to leaf transmission, leaf penumbra and geometry of leaves. The variations of output according to the multileaf opening during the irradiation need to be accounted for as well. These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

가토 정맥에서 CT 조영제의 혈관외유출 예방을 위한 EDA 시스템의 실험적 연구 (An Experimental Study for the Prevention of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit)

  • 권대철;정석희;양성환;조문선;장근조;김순근;유병규;이종석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.238-245
    • /
    • 2006
  • CT 검사에서 조영제 혈관외유출을 예방하기 위해 EDA 시스템을 개발하여 가토를 대상으로 실험적으로 혈관외유출의 검출 효율을 평가하였다. 7마리의 가토 IV 정맥 부위에 EDA 시스템의 스트레인게이지를 부착하여 조영제를 주입하면서 혈관외유출 검출 효율을 평가하였다. 조영제의 혈관외유출은 7건으로 혈관외유출 용량 $14{\sim}23ml$ (평균 18.86 ml), 혈관외유출 발생시간 평균 11.29초, 평균압력 109.71 psi, EDA 시스템에서 스트레인게이지의 분해능 평균 512.18, 진양성 7건, 진음성 19건, 위양성 2건이었고, 민감도 100%, 특이도 90%로 나타났다. 개발된 EDA 시스템을 가토에 실험적으로 적용하여 소량의 혈관외유출 조영제를 검출하는 효율이 있어 혈관외유출을 예방하는 효과가 있다.

  • PDF

집중 태양열에 의한 온도구배가 열전발전모듈의 출력 성능에 미치는 영향 (Influence of temperature gradient induced by concentrated solar thermal energy on the power generation performance of a thermoelectric module)

  • 최경후;안다훈;부준홍
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.777-784
    • /
    • 2017
  • 일반적으로 열전발전 소자를 사용하여 에너지 하베스팅을 하는 경우, 시스템의 작동환경에 의해 주어지는 온도구배를 활용하게 된다. 따라서 열전소자의 특성상 큰 온도구배를 기대하기 어려운 작동환경에서는 원하는 출력을 얻을 수 없으며, 작동 온도가 높을 때 얻어지게 되는 최적의 발전효율을 기대하기 힘들다. 자연환경에서 얻을 수 있는 태양에너지를 활용한 신재생 에너지의 활용은 그 동안 태양광발전이나 태양열발전에 국한되어 왔다. 태양광발전은 태양광의 일정 파장대만 사용하고 빛의 산란에 의해 발전효율이 낮아지는 단점이 있으며, 태양열발전은 일반적으로 대규모 설비를 갖춰야 하는 공간상의 제약이 있다. 본 연구에서는 태양열을 집광하여 열전소자에 조사함으로서 큰 온도구배를 형성하여 상용 열전소자의 출력을 향상시킬 수 있는 간단한 소형 발전시스템을 설계 및 제작하였다. 장시간 태양열 집중을 위해 태양 추적 장치를 설치하였으며, 열전소자 하부에 고온의 태양열이 전달되어 온도 편차가 줄어드는 현상을 막기 위해 액체 순환식 냉각기를 설치하여 큰 온도구배를 유지할 수 있도록 설계한 후, 일련의 실험으로 시험하여 그 유용성과 타당성을 검증하였다.

수상 태양광 발전을 위한 플라스틱 부유체 개발에 관한 연구 (A Study on the Development of Plastic Floater for Solar Power Plant on a Body of Water)

  • 정광수;정인준;신동길
    • 한국산학기술학회논문지
    • /
    • 제21권10호
    • /
    • pp.283-290
    • /
    • 2020
  • 본 연구에서는 수상 태양광 발전설비를 위한 부유체 개발에 대하여 연구하였다. 부유체는 단위 모듈로 이루어진 금속재질의 프레임과 상부의 태양광 패널들을 수상에서 부력을 이용하여 지지하는 부품이다. 단위 모듈화된 프레임의 구조와 태양광 패널의 설치 환경을 고려하여 부유체에 작용하는 하중을 산출하였다. 부유체의 형상은 수압과 부력을 고려하여 바깥쪽으로 둥근 형태를 가지도록 하였으며, 유한요소해석을 수행하여 부유체의 세부 형상과 두께를 설계하였다. 설계된 부유체는 선형저밀도폴리에틸렌 플라스틱을 사용하여 회전성형법으로 제작하였다. 부유체의 압축강성을 측정한 결과, 제작된 부유체는 최대하중 322.7 kgf의 4배 이상에서도 붕괴를 일으키지 않고 강성을 유지하는 것으로 나타났다. 부유체의 장기 압축 시험을 수행하기 위하여 중력을 이용한 무게추 방식의 장기 하중 인가 장치를 제작하였다. 부유체에 무게추를 올린 후 7일 간 부유체의 압축량을 측정한 결과, 작은 하중에서도 지속적인 압축 변형이 발생하였다. 그러나 상시 하중 100 kgf 에 대하여 10년 압축량을 예측한 결과 약 4.64 mm 의 작은 변형이 예측되었다. 이와 같이 개발된 부유체는 수상 태양광 발전시스템에 사용이 가능한 것으로 나타났다.

온도 측정을 통한 상용 쑥뜸의 자극효과에 대한 실험적 연구 -연소시간 및 연소온도를 중심으로- (Experimental Study on the Stimulating Effect of Commercial Moxa Combustion through the Measurement of Temperature -Focused on Combustion time and temperature-)

  • 이건목;양유선;이건휘
    • Journal of Acupuncture Research
    • /
    • 제19권2호
    • /
    • pp.114-127
    • /
    • 2002
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion objectively and to be used as the quantitative data for developing the new thermal stimulating treatment by observing the combustion time and temperature of commercial moxaes. Methods : We have selected two types(large-size moxa A(LMA), large-size moxa B (LMB)) among large moxaes used widely in the clinic. We examined combustion times, temperatures in each period during a combustion of moxa. Results : 1. The combustion time in the preheating period was about 30sec in both moxaes on the non-contact heated surface. 2. The combustion time in the heating period was about 345sec in LMA and about 1391 sec in LMB, about 4 times longer in LMB on the non-contact surface. 3. The maximum temperature in the heating period was $44.5^{\circ}C$ in LMA and $45.4^{\circ}C$ in LMB respectively, higher by $0.9^{\circ}C$ in LMB. The average temperature in the heating period was $35.5{\sim}37.6^{\circ}C$ in LMA and $36.0{\sim}39.8^{\circ}C$ in LMB, a little higher in LMB. 4. The combustion time in the retaining period in LMA was 45.4sec and 13% of that in the heating period, and in LMB 594.7sec and 43% of that in the heating period on the non-contact surface. 5. On the point(PH) measured maximum temperature, the average temperature during the retaining period was $44.0^{\circ}C$, $42.9^{\circ}C$ respectively and the temperature at an end of the retaining period was $43.0^{\circ}C$, $40.2^{\circ}C$ respectively. 6. The time at a beginning of the cooling period was about 418 sec from ignition in LMA and 2021sec in LMB, and the temperature at that time was $36.9{\sim}39.1^{\circ}C$ on the non-contact surface. Conclusion : It was thought that not only the figure of moxicombustion device, but also the form and size of moxa had influence on the combustion characteristics deciding the performance of stimulus seriously.

  • PDF

Hexagonal Boron Nitride Monolayer Growth without Aminoborane Nanoparticles by Chemical Vapor Deposition

  • Han, Jaehyu;Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.409-409
    • /
    • 2014
  • Recently hexagonal boron nitride (h-BN), III-V compound of boron and nitrogen with strong covalent $sp^2$ bond, is a 2 dimensional insulating material with a large direct band gap up to 6 eV. Its outstanding properties such as strong mechanical strength, high thermal conductivity, and chemical stability have been reported to be similar or superior to graphene. Because of these excellent properties, h-BN can potentially be used for variety of applications such as dielectric layer, deep UV optoelectronic device, and protective transparent substrate. Ultra flat and charge impurity-free surface of h-BN is also an ideal substrate to maintain electrical properties of 2 dimensional materials such as graphene. To synthesize a single or a few layered h-BN, chemical vapor deposition method (CVD) has been widely used by using an ammonia borane as a precursor. Ammonia borane decomposes into hydrogen (gas), monomeric aminoborane (solid), and borazine (gas) that is used for growing h-BN layer. However, very active monomeric aminoborane forms polymeric aminoborane nanoparticles that are white non-crystalline BN nanoparticles of 50~100 nm in diameter. The presence of these BN nanoparticles following the synthesis has been hampering the implementation of h-BN to various applications. Therefore, it is quite important to grow a clean and high quality h-BN layer free of BN particles without having to introduce complicated process steps. We have demonstrated a synthesis of a high quality h-BN monolayer free of BN nanoparticles in wafer-scale size of $7{\times}7cm^2$ by using CVD method incorporating a simple filter system. The measured results have shown that the filter can effectively remove BN nanoparticles by restricting them from reaching to Cu substrate. Layer thickness of about 0.48 nm measured by AFM, a Raman shift of $1,371{\sim}1,372cm^{-1}$ measured by micro Raman spectroscopy along with optical band gap of 6.06 eV estimated from UV-Vis Spectrophotometer confirm the formation of monolayer h-BN. Quantitative XPS analysis for the ratio of boron and nitrogen and CS-corrected HRTEM image of atomic resolution hexagonal lattices indicate a high quality stoichiometric h-BN. The method presented here provides a promising technique for the synthesis of high quality monolayer h-BN free of BN nanoparticles.

  • PDF

나노 실리카 및 실록산이 초소형 전자소재 접착제용 에폭시 복합재의 물성에 미치는 효과 (Effects of Nano Silica and Siloxane on Properties of Epoxy Composites for Adhesion of Micro Electronic Device)

  • 이동현;김대흠
    • Korean Chemical Engineering Research
    • /
    • 제47권3호
    • /
    • pp.332-336
    • /
    • 2009
  • 초소형 전자소재 접착용 고분자 소재 접착제는 접착소재와 칩 또는 기판 간의 열팽창계수 차이에 의한 박리, 크래킹과 접착력 부족 등의 문제점이 발생된다. 이러한 결점의 보완을 위하여 무기입자 및 첨가물을 통해 접착제의 열팽창계수를 낮추거나, 접착제의 유연성을 부여하는 방법 등이 사용되고 있다. 실록산/실리카/에폭시 나노복합재에서 실록산과 실리카의 첨가가 열적, 기계적 물성에 미치는 효과를 확인하기 위한 실험을 진행하였다. 3-glycidoxypropyltrimethoxysilane(GPTMS)로 처리하여 친수성의 나노실리카 입자를 소수성 입자로 변성시켜 고분자 매트릭스와의 상용성 문제를 해결하고자 하였다. 표면처리하지 않은 실리카인 $Aerosil^{(R)}$200을 첨가한 AMS/Aerosil/에폭시 나노복합재의 유리전이온도는 125에서 $118^{\circ}C$로 감소하였고, 모듈러스는 2,225에서 2,523 MPa까지 증가하였다. 표면처리한 M-silica를 첨가한 AMS/M-silica/에폭시 나노복합재 또한 비슷한 경향이었으며, 유리전이온도가 124에서 $120^{\circ}C$로 감소했고 모듈러스는 1,981에서 2,743 MPa까지 증가하였다. 실리카의 표면개질 유무에 상관없이 열팽창계수는 감소하는 추세를 보였다.

자동노출제어장치 센서적용을 위한 스크린 프린팅 제작방식의 고흡수율 광도전체 특성평가 (Evaluation of High Absorption Photoconductor for Application to Auto Exposure Control Sensor by Screen Printing Method)

  • 김대국;김교태;박정은;홍주연;김진선;오경민;남상희
    • 한국방사선학회논문지
    • /
    • 제9권2호
    • /
    • pp.67-72
    • /
    • 2015
  • 진단방사선 분야에서는 진단 최적화를 위하여 자동노출제어장치의 활용이 국제적으로 권고되고 있다. 하지만, 기존의 상용화된 광도전체 센서는 제작 공정의 복잡하고 장시간 방사선에 노출될 경우 다양한 성능 저하가 발생하는 문제점이 있다. 이에 본 연구에서는 X-ray 흡수율이 높으면서도 제작이 용이한 장점을 가진 광도전체 기반 센서의 AEC 적용 가능성을 평가하고자 한다. 실험결과, SNR 증가를 통하여 우수한 검출 효율을 가지는 센서의 제작가능성을 확인하였고, 정확한 턴-오프가 가능할 것으로 사료된다. 또한 잠상 영상 및 투과율 실험 결과, 광도전체에 의한 Ghost effect가 나타나지 않음을 확인하였으며, PbO를 제외한 광도전체의 경우 80% - 90%의 우수한 투과율을 확인하였다. 그러므로 상용화된 기존 상품에 대비하여 도핑농도 변화에 따른 성능 저하 및 기계적 안정성이 뛰어나며 제작이 용이한 광도전체 기반의 센서는 AEC 센서로 적용이 가능할 것으로 기대된다.

촬영 및 투시용 X선 장치의 기본안전과 필수 성능에 관한 개별 기준규격의 동향 (The Tendency of Medical Electrical Equipment - IEC 60601-2-54: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Radiography and Radioscopy)

  • 노영훈;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.331-336
    • /
    • 2015
  • 식품의약품안전처 고시 "의료기기의 전기 기계적 안전에 관한 공통기준규격"이 IEC 60601-1 [3판] 따라 개정되었고 IEC-60601-1의 개별규격인 IEC 60601-2-54 또한 촬영 및 투시용 X선 장치의 기본 안전과 필수 성능에 관한 개별 기준규격으로 고시화 될 예정이다. 따라서 개별 규격의 도입에 앞서 주요 요건을 소개하고자 이 기술보고서를 작성하였다. IEC 60601-2-54의 목적은 촬영 및 투시를 위한 의료용 전기기기(이하 ME 기기) 및 ME 시스템에 요구되는 기본 안전과 필수 성능 요구사항을 확보하려는 것이다. IEC 60601-2-54는 방사선 촬영 및 투시장치의 X선 고전압장치, X선 기계장치, 방사선 방어 등에 관한 내용이다. 의료기기의 전기 기계적 안전에 관한 공통기준규격, 의료기기의 전자파 안전에 관한 공통기준규격, 의료기기의 방사선안전에 관한 보조기준 규격이 본 규격에 적용되었다. IEC-60601-2-54가 고시화될 경우 촬영 및 투시용 X선 장치의 기본 안전과 필수 성능에 관한 이해를 넓히고 국내 의료기기 산업의 국제화에 일조할 것이라고 판단된다.