• Title/Summary/Keyword: mechanical components

Search Result 3,268, Processing Time 0.033 seconds

A Study on the Development of the Dynamic Photoelastic Hybrid Method for Two Dissimilar Isotropic Bi-Materials (두 상이한 등방성 이종재료용 동적 광탄성 하이브리드법 개발에 관한 연구)

  • Sin, Dong-Cheol;Hwang, Jae-Seok;Gwon, O-Seong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.434-442
    • /
    • 2001
  • When the interfacial crack of two dissimilar isotropic bi-materials is propagated with constant velocity along the interface, stress and displacement components are derived in this research. The dynamic photoelastic experimental hybrid method for bimaterial is introduced. It is assured that stress components and dynamic photoelastic hybrid method developed in this research are valid. Separating method of stress component is introduced from only dynamic photoelastic fringe patterns. Crack propagating velocity of interfacial crack is 80∼85% (in case of aluminum, 24.3∼25.9%) of Rayleigh wave velocity of epoxy resin. The near-field stress components of crack-tip are similar with those of pure isotropic material under static or dynamic loading, but very near-field stress components of crack-tip are different from those.

Comprehensive Residual Stress Distributions in a Range of Plate and Pipe Components

  • Lee Hyeong-Yeon;Kim Jong-Bum;Lee Jae-Han;Nikbin Kamran M.
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.335-344
    • /
    • 2006
  • A comprehensive review of through thickness transverse residual stress distributions in a range of as-welded and mechanically bent components made up of a range of steels has been carried out, and simplified generic transverse residual stress profiles for a plate and pipe components have been proposed. The geometries consisted of welded pipe butt joints, T-plate joints, tubular T-joints, tubular Y-joints and a pipe on plate joints as well as cold bent tubes and pipes. The collected data covered a range of engineering steels including ferritic, austenitic, C-Mn and Cr-Mo steels. Measured residual stress data, normalised with respect to the parent material yield stress, has shown a good linear correlation versus the normalised depth of the region containing the residual stress resulting from the welding or cold-bending process. The proposed simplified generic residual stress profiles based on the mean statistical linear fit of all the data provides a reasonably conservative prediction of the stress intensity factors. Whereas the profiles for the assessment procedures are fixed and case specific, the simple bilinear profiles for the residual stresses obtained by shifting the mean and bending stress from the mean regression line have been proposed and validated.

Mechanical Modeling of Rollable OLED Display Apparatus Considering Spring Component

  • Ma, Boo Soo;Jo, Woosung;Kim, Wansun;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.2
    • /
    • pp.19-26
    • /
    • 2020
  • Flexible displays have been evolved into curved, foldable, and rollable as the degree of bending increases. Due to the presence of brittle electrodes (e.g. indium-tin oxide (ITO)) that easily cracked and delaminated under severe bending deformation, lowering mechanical stress of the electrodes has been critical issue. Because of this, mechanical stress of brittle electrode in flexible displays has been analyzed mostly in terms of bending radius. On the other hand, in order to make rollable display, various mechanical components such as roller and spring are needed to roll-up or extend the screen for the rollable display apparatus. By these mechanical components, brittle electrode in the rollable display is subjected to the excessive tensile stress due to the retracting force as well as the bending stress by the roller. In this study, mechanical deformation of rollable OLED display was modeled considering boundary conditions of the apparatus. An analytical modeling based on the classical beam theory was introduced in order to investigate the mechanical behavior of the rollable display. In addition, finite element analysis (FEA) was used to analyze the effect of mechanical components in the apparatus on the brittle electrode. Furthermore, a strategy for improving the mechanical reliability of the rollable display was suggested through controlling the stiffness of adhesives in the display panel.

An application plan of NSWC-98/LE1 when predicting the reliability of mechanical components of design and development phase (체계 개발 단계별 기계 부품에 대한 신뢰도 예측 시 NSWC-98-LE1 적용 방안)

  • Kwon, Ki Sang;Park, Eun Sim;Cho, Cha Hyun;Lee, Dong Woo;Lee, Su Jung
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.35-43
    • /
    • 2008
  • Generally, in analysis of reliability of Design and Development Phase, reliability of electrical components is analyzed based on standards such as MIL-HDBK-217F, Bellcore Issue 4,5,6 by analyzing stress of architectural side (Power, Voltage, Current and quality level of components) of weapon system and stress of operational side (operational environment, operational temperature, Operational Profile). But the reliability of mechanical components is analyzed based on the data book of failure history of mechanical parts called NPRD-95(Nonelectronic Parts Reliability Data-95) without any analysis of above stress. However, even if it's the same mechanical parts, it might have different failure rate(fatigue, wear, corrosion) during operation depending on how weary(stress : pressure, vibration, temperature during operation) the parts are. Therefore, analyzing reliability using just data book can cause big difference in reliability instead of analyzing based upon stressfulness that parts might have, operational concept, and other various factors. Thus, This paper will guide the way of predicting reliability by organizing ways of predicting reliability for system organization and adopt ing NSWC-98/LE1(Naval Surface Warfare Center-98/LE1) for mechanical components.

  • PDF

Perceptual Fusion of Infrared and Visible Image through Variational Multiscale with Guide Filtering

  • Feng, Xin;Hu, Kaiqun
    • Journal of Information Processing Systems
    • /
    • v.15 no.6
    • /
    • pp.1296-1305
    • /
    • 2019
  • To solve the problem of poor noise suppression capability and frequent loss of edge contour and detailed information in current fusion methods, an infrared and visible light image fusion method based on variational multiscale decomposition is proposed. Firstly, the fused images are separately processed through variational multiscale decomposition to obtain texture components and structural components. The method of guided filter is used to carry out the fusion of the texture components of the fused image. In the structural component fusion, a method is proposed to measure the fused weights with phase consistency, sharpness, and brightness comprehensive information. Finally, the texture components of the two images are fused. The structure components are added to obtain the final fused image. The experimental results show that the proposed method displays very good noise robustness, and it also helps realize better fusion quality.

Application of Instantaneous Frequency Analysis(II) -Conditions of Existing Negative Frequency Components- (순간주파수 분석기법의 응용 (2) -주파수의 부호를 결정하는 조건-)

  • 김정태;임병덕
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.1057-1063
    • /
    • 1994
  • An instantaneous frequency analysis is a technique to examine a signature for the rotating machinery if the signal has several transitions within a cycle. This paper discusses the conditions of existing negative frequency components in the instantaneous frequency. By using a signal consisted of two frequency components, the instantaneous frequency analysis is conducted while the amplitude ratio between two frequency components has been changed. The analysis shows that, depending on the amplitude ratio, the instantaneous frequencies have averaged, zero-valued, or negative components. It turns out that the negative-valued instantaneous frequencies, which have been regarded as the noise effect, are the consequence of the calculation process for the multisignal components. The criteria of existing the negative values in instantaneous frequencies is given in terms of the relative amplitude ratio and the frequency difference. Especially when the amplitude ratio approaches to 1, the instantaneous frequency fluctuates ${\pm}\infty$ in theory, which implies that instantaneous frequency has unstable region around the amplitude ratio, 1.Also, as the frequency difference between major signal components is increased, the region of existing negative instantaneous becomes broader. In an instantaneous frequency analysis, therefore, a narrow band analysis is suggested, with extreme care if the amplitude ratio approaches to 1. In this paper, a vibration signal monitored from a rotating machinery is also examined as an application example in order to show the existence of negative instantaneous frequencies components.

Thermal Fatigue Test of an Annular Structure

  • Hwang Jeong-Ki;Suh Chang-Min;Kim Chae-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2006
  • A half-scaled large test model for the main components of the real annular structure was built and the thermal behaviors were experimented and obtained by thermal cyclic loads. The model design and the test conditions for the thermal loads were determined to take into consideration the thermal and mechanical loads acting on the real annular structure by finite element analyses. Temperature profiles and strains of the main components of the model were measured at an early stage of the test and periodically throughout the test in the given test conditions. After completion of the thermal cyclic tests, no evidence of crack initiation and propagation were identified by a dye penetration test. The measured strains at the critical parts were slightly increased proportionally with the increase in the number of the thermal cycles.

Development of the Hybrid Fault Current Limiter (복합형 한류기 개발)

  • Park, K.B.;Lee, G.H.;Bang, S.H.;Choi, W.J.;Sim, J.W.;Sin, Y.S.;Kim, Y.G.;Hyun, O.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.125-125
    • /
    • 2010
  • The Hybrid Fault current limit combined the semiconductor switching components, for example IGBT, with mechanical fast switch reduced mechanical and thermal stress on electrical machines, for example circuit breaker, transformer, and so on, in the electric network. We had focused on reducing the voltage stress of the semiconductor switching components by the mechanical fast switch. As a result, we could dramatically reduce amount of semiconductor switching components only using parallel arrangement of them, not series.

  • PDF

Design and Fabrication of 6-Component Forces and Moments Sensor Using a Column Structure (원기둥을 이용한 6축 힘/모멘트 센서의 설계 및 제작)

  • Shin, Hong-Ho;Kim, Jong-Ho;Park, Yon-Kyu;Joo, Jin-Won;Kang, Dae-Im
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1288-1295
    • /
    • 2002
  • The column-type sensing element in building and mechanical construction parts was designed as three forces and three moments sensor by attaching strain gages approximately. Compared to conventional multi-component sensor, the designed sensor has high stiffness and low cost. The radius of the column was designed analytically and compared with finite element analysis. The interference errors between components were minimized by using addition and subtraction procedure of signals. The fabricated sensor was tested by using a deadweight force standard machine and a six-component force calibration machine. The calibration results showed that the 6-component forces and moments sensor had interference error less than 7.3 % between $F_x$ and $M_x$ components, and 5.0 % in case of other components.

Friction Reduction Properties of Evaporation Coated Petroleum and Silicone Oil Lubricants (증발 코팅법으로 증착된 광유와 실리콘 오일 윤활제의 마찰 저감 특성)

  • Yoo, Shin Sung;Kim, Dae Eun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.8
    • /
    • pp.864-869
    • /
    • 2013
  • As the size of mechanical components decreases, capillary forces and surface tension become increasingly significant. A major problem in maintaining high reliability of these small components is that of large frictional forces due to capillary action and surface tension. Unlike the situation with macro-scale systems, liquid lubrication cannot be used to reduce friction of micro-scale components because of the excessive capillary and drag forces. In this work, the feasibility of using evaporation to coat a thin film of organic lubricant on a solid surface was investigated with the aim of reducing friction. Petroleum and silicone oils were used as lubricants to coat a silicon substrate. It was found that friction could be significantly reduced and, furthermore, that the effectiveness of this method was strongly dependent on the coating conditions.