• 제목/요약/키워드: measuring weight

검색결과 1,158건 처리시간 0.034초

Comparison Study of Sound Transmission Loss in High Speed Train

  • Kim, Tae-Min;Kim, Jeung-Tae
    • International Journal of Railway
    • /
    • 제4권1호
    • /
    • pp.19-27
    • /
    • 2011
  • Many studies for improving the railway vehicle's performance and comfort such as speed, weight and noise are currently in progress. Improving the structural characteristics of the vehicle for greater noise insulation is considered important for reducing disturbance due to noise, but measuring transmission loss entails large costs. This study explores an alternative method for estimating and measuring the railway vehicle's transmission loss that involves on applying the numerical analysis coupled with scaled reverberation chamber measurement. The transmission loss measurement using scaled reverberation chamber was performed after the compensation value was found through 1mm thickness(1t) specimen. For numerical analysis, a commercially available acoustics solver VA ONE was used. The proposed method is found to lead to transmission loss measurement comparable to the measurements based on large-scale reverberation chamber. Thus, it can be argued that a reliable method has been developed for measuring railway vehicle's transmission loss.

유비쿼터스 지향의 16채널 스트레인 게이지 계측 시스템 개발 (16 Channel Strain Gauge Measuring Ubiquitous System Development)

  • 장순석;김경석;원용일;김대곤
    • 제어로봇시스템학회논문지
    • /
    • 제12권9호
    • /
    • pp.912-917
    • /
    • 2006
  • A strain gauge weight measuring instrumentation system was designed with RF sensor network facilities. In the sensor module system data conversion and a series of signal processing were totally equipped. 16 strain gauges are incoming sensors and each output of the strain gauge was amplified and filtered for proper analog signal processing. Several measuring instrumentation OP amps and general purposed OP amps were used. 12 bits A/D converters converted analog signals to digital bits and a PIC microprocessor controlled the 16 channels of strain gauges. RF RS232 modules were used for wireless communication between the PIC microprocessor and an Ethernet host far a remote sensor monitoring system development.

Quantitative NMR Analysis of PTMEG compounds

  • Kim, Gilhoon;Won, Hoshik
    • 한국자기공명학회논문지
    • /
    • 제20권1호
    • /
    • pp.7-12
    • /
    • 2016
  • PTMEG(Polytetramethylene ether glycol) is a polymer compound widely used as a wide range of applications in the textile industry. PTMEG substance carrying various 1,800~2,000 molecular weight are mainly used as the raw material of the spandex production. Molecular weight and degree of polymerization value for 4 different PTMEG samples under pilot plant scale synthetic process were determined by a new quantitative NMR method. In NMR experiments, p-toluenesulfonic acid(TSOH) was used for external standard material of PTMEG quantitative analysis. were measuring The concentration of the primary standard TSOH was measured by UV/Vis spectroscopy. By using NMR peak assignments and the integral values of designated proton NMR peaks, We were able to measure the % composition of the synthetic PTMEG polymers, concentrations, molecular weight and the degree of polymerization that show the synthetic process of each manufacturing pilot plant. By utilizing a newly developed quantitative NMR method were able to obtain the molecular weight of PTMEG samples within 0.08 error % range.

$4{\sim}6$세 유아의 무게 측정전략 발달에 관한 연구 (Strategies Used by Young Children in Weight Measurement Tasks)

  • 이보영;김주영
    • 대한가정학회지
    • /
    • 제45권7호
    • /
    • pp.49-60
    • /
    • 2007
  • The purpose of this study was to analyze the weight measurement tasks according to children's ages and whether 4-to 6-year-old children use proper measurement equipment to measure weight. The study subjects were 105 preschool children: 37,38, and 30 4-, 5-, and 6-year-old children, respectively. The results showed that young children use 3 to 4 strategies. They used a strategy to estimate objects visually on the first step in measurement by direct comparison. On the second step, in measurement by nonstandard unit, they held up objects with one hand or two hands. That is, two strategies were shown in measuring objects with hands in this second step. On the third step, which is measured by standard unit, they used a strategy to choose the equal arm balance out of suggested measurement equipment.

The design and fabrication of management system for weight measuring food wastes for indoor

  • Seo, Chang Ok;Kim, Gye Kuk
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권10호
    • /
    • pp.35-40
    • /
    • 2017
  • A weight-rate disposal system for food waste has been implemented in all over the country. The food waste disposal system is a system paying service charge according to the volume of food waste, which means the more we produce waste, the more we have to pay as much.Since this policy was introduced, each of apartment, villa, etc and other buildings must install the food waste disposal system. We can say that there are strong points in this paper for us to install a weight monitor on the channel of the floor each, accumulate the fares automatically and collect the fares at the end of every month.

표준실험동에서 중량충격음의 방사 특성 (Radiation Characteristics of Heavy-weight Floor Impact Sounds in a Standard Test Building)

  • 유승엽;정영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.381-384
    • /
    • 2005
  • The purpose of this study is to develop a prediction model for evaluating heavy-weight floor impact sounds in a test building. Three rooms in the test building (slab thickness In and 240mm), which consist of frame concrete structures were tested and modeled. First, the SPL distribution in the receiving room was analyzed by measuring SPL at 90 positions using a bang machine. Then, a vibration model using finite element method is proposed considering the material properties and boundary conditions. In addition, the result of transient analysis was compared with field measurements using a standard heavy-weight impact source. Through a vibro-acoustic simulation program, an acoustic model evaluating the building elements (reflected wall, nor, window and door) was proposed. Finally, validation of the prediction model was conducted by vibro-acoustic analysis with field measurements of noise radiation characteristics in receiving rooms.

  • PDF

0.01d 폴리에스테르 초극세 섬유의 알칼리 감량과 물성 (Alkaline Weight Reduction and Physical Properties of 0.01d Polyester Ultramicro Fiber)

  • 박재민;정동석;노환권;이문철
    • 한국염색가공학회지
    • /
    • 제18권4호
    • /
    • pp.37-42
    • /
    • 2006
  • Two kinds of sea-island type polyester ultramicro fibers (fiber fineness : 0.01 and 0.05 denier) were treated with NaOH varying time and concentration. Surface morphology of the treated fibers with alkaline weight loss was observed by SEM. The treated effects were investigated by measuring density, melting temperature, and X-ray diffraction patterns. The surface morphology of the polyester ultramicro fiber was changed by NaOH concentration. Weight loss of 0.01d fiber was much larger than that of 0.05d fiber. Density and crystallinity were increased with weight loss of fiber. After the weight loss had finished, the density and crystallinity were decreased because of attack of island partition of the fiber. A melting temperature$(T_m)$ is $250^{circ}$ at untreated fiber on the whole and in 0.05d fiber the $(T_m)$ is $252^{circ}$ at untreated. In 0.01d fiber the $(T_m)$ was increased with weight loss of fiber.

0.01 mm 급 우량계 개발에 관한 연구 (A Study on the Development of Raingauge with 0.01 mm Resolution)

  • 이부용
    • 한국환경과학회지
    • /
    • 제13권7호
    • /
    • pp.637-643
    • /
    • 2004
  • A new method of automatic recording raingauge is developed to measure rainfall with 0.01mm resolution. This use two different signals to measure rainfall more accurately compare than other raingauges. One is weight of the tipping bucket with rainfall amount and the other is pulse from tipping bucket reverse. New method applied 1 mm tipping bucket mechanism and install loadcell under tipping bucket mechanism for measuring rainfall weight. Loadcell measure weight of rainfall until 1 mm with 0.01 mm resolution and more than 1 mm than bucket reverse and pulse signal generate, after that loadcell measure weight again. The validation of new instrument was examined in the room 65 mm/hour rainfall rate total 53 mm range. There is below than 1 % error of absolute rainfall amount and 0.01 mm resolution. The field test of instrument was carried out by comparing its measured values with values recorded by weight type and standard type on June 1 2003 at Terrestrial Environmental Research Center at Tsukuba University in Tsukuba of Japan, when it has recorded total amount of 40.58 mm rainfall by standard raingauge and new raingauge recorded 41.032 mm. Same rainfall intensity pattern observed in field observation with weight type raingauge. Rainfall intensity between weight type and Lee-A type raingauge reached 0.9947 correlation in 3 minute average.

추교환식 실하중 힘표준기의 개발 (Development of a Deadweight Force Standard Machine with Weight Change Mechanism)

  • 김갑순;송후근;강대임;이정태;박연규
    • 한국정밀공학회지
    • /
    • 제16권8호
    • /
    • pp.203-212
    • /
    • 1999
  • This paper describes a deadweight force standard machine with the weight change mechanism which can be used as a primary force standards at a national metrology institute. Since commercial deadweight force machine can generate forces by hanging weights to the weight supporter serially, force steps from deadweight force measuring devices of each having different capacity. In order to increase the force steps, we have specially designed a weight mechanism in which the machine can select the necessary weights and generate the load by hanging the selected weights to the weight supporter. The machine can generate 속 force of the range of 2 kN to 110 kN with force step of 1 kN. All weights have been accurately compensated and calibrated by a mass comparator and its standard uncertainty is less than 2.2 ${\times}\;10^{-6}$. The relative expanded uncertainty of the machine is 1.3 ${\times}\;10^{-5}$.

  • PDF

중주(中炷) 직접구(直接灸)의 연소특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Combustion in Middle Size-direct Moxibustion)

  • 최연성;김도호;이건휘;이건목
    • Journal of Acupuncture Research
    • /
    • 제26권1호
    • /
    • pp.111-119
    • /
    • 2009
  • Objectives : The purpose of this study is to investigate the mechanism and effect of moxa bucket moxibustion, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxa bucket moxibustion. Methods : We have selected the moxa bucket moxibustion. We have made a comparative study of the thermodynamic characteristics of moxa bucket moxibustion. We have examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa bucket moxibustion made by oak wood. Results : 1. We could design the moxa bucket moxibustion so that it has $57.6^{\circ}C$ maximum temperature with 7g weight and 10mm height, if we use more weight of moxa or lower height of moxa, we can observe relatively elevated maximum temperature. We observed the maximum temperature following the measuring position of moxa bucket and we could see higher temperature at the center of the moxa bucket and lower temperature at the side of the moxa bucket. 2. We could design the moxa bucket moxibustion with 5g moxa and 10mm height so that it has 0.12 $1^{\circ}C/sec$ of maximum temperature gradient, and it has relatively high temperature gradient at lower weight and height condition. 3. We could design the moxa bucket moxibustion with 7g moxa and 15mm height so that it has 4,135sec of the longest effective temperature combustion time. If we use more weight of moxa or higher height of moxa, we can observe relatively extended effective temperature combustion time. Conclusions : We observed the longest effective combustion time following the measuring position of moxa bucket. We can see a higher temperature at the center of the moxa bucket and a lower temperature at the side of the moxa bucket.

  • PDF