• Title/Summary/Keyword: measuring volume

Search Result 793, Processing Time 0.027 seconds

The Infuelence of Sodium Chloride on the Volume Resistivity Characteristics of Transformer Oils (변압기유의 체적고유저항특성에 미치는 염분의 영향)

  • 조경순;이정상;임창수;김석환;이충옥;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.203-206
    • /
    • 1996
  • In order to investigate the infulence of sodium chloride on the volume resistivity characteristics of transformer oils in temperature range of 20~100[$^{\circ}C$] were made researches. The geometrical capacitance of electrode with coaxial cylindrical shape for measuring the volume resistivity was 16[pF], and hoghmegaohm meter model VMG-1000 was used, the applying voltage were DC 100, 250, 500 and 1000[V]. The classification for the physical properties of specimen by FTIR Spectroscopy was carried out. AS a result of experiment, the value for volume resistivity is increased with sodium chloride contents.

  • PDF

Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom (간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증)

  • Kim, Jin-Sung;Cho, June-Sik;Shin, Kyung-Sook;Kim, Jin-Hwan;Jeon, Ho-Sang;Cho, Gyu-Seong
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

  • PDF

Image Processing Algorithm for Weight Estimation of Dairy Cattle (젖소 체중추정을 위한 영상처리 알고리즘)

  • Seo, Kwang-Wook;Kim, Hyeon-Tae;Lee, Dae-Weon;Yoon, Yong-Cheol;Choi, Dong-Yoon
    • Journal of Biosystems Engineering
    • /
    • v.36 no.1
    • /
    • pp.48-57
    • /
    • 2011
  • The computer vision system was designed and constructed to measure the weight of a dairy cattle. Its development involved the functions of image capture, image preprocessing, image algorithm, and control integrated into one program. The experiments were conducted with the model dairy cattle and the real dairy cattle by two ways. First experiment with the model dairy cattle was conducted by using the indoor vision experimental system, which was built to measure the model dairy cattle in the laboratory. Second experiment with real dairy cattle was conducted by using the outdoor vision experimental system, which was built for measuring 229 heads of cows in the cattle facilities. This vision system proved to a reliable system by conducting their performance test with 15 heads of real cow in the cattle facilities. Indirect weight measuring with four methods were conducted by using the image processing system, which was the same system for measuring of body parameters. Error value of transform equation using chest girth was 30%. This error was seen as the cause of accumulated error by manually measurement. So it was not appropriate to estimate cow weight by using the transform equation, which was calculated from pixel values of the chest girth. Measurement of cow weight by multiple regression equation from top and side view images has relatively less error value, 5%. When cow weight was measured indirectly by image surface area from the pixel of top and side view images, maximum error value was 11.7%. When measured cow weight by image volume, maximum error weight was 57 kg. Generally, weight error was within 30 kg but maximum error 10.7%. Volume transform method, out of 4 measuring weight methods, was minimum error weight 21.8 kg.

Volume Calculation for Filling Up of Rubbish Using Stereo Camera and Uniform Mesh (스테레오 카메라와 균일 매시를 이용한 매립지의 환경감시를 위한 체적 계산 알고리즘)

  • Lee, Young-Dae;Cho, Sung-Youn;Kim, Kyung;Lee, Dong-Gyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.3
    • /
    • pp.15-22
    • /
    • 2012
  • For the construction of safe and clear urban environment, it is necessary that we identify the rubbish waste volume and we know the accuracy volume. In this paper, we developed the algorithm which computes the waste volume using the stereo camera for enhancing the environment of waste repository. Using the stereo vision camera, we first computed the distortion parameters of stereo camera and then we obtained the points cloud of the object surface by measuring the target object. Regarding the points cloud as the input of the volume calculation algorithm, we obtained the waste volume of the target object. For this purpose, we suggested two volume calculation algorithm based on the uniform meshing method. The difference between the measured volume such as today's one and yesterday's one gives the reposit of waste volume. Using this approach, we can get the change of the waste volume repository by reading the volume reports weekly, monthly and yearly, so we can get quantitative statistics report of waste volume.

Monitoring System to Measure the Waste Volume of Landfill Facility using 3D Laser Scanner (3D 레이저 스캐너를 이용한 매립장의 체적 계측을 위한 모니터링시스템)

  • Cho, Sung-Youn;Lee, Young-Dae;Ryu, Seung-Ki
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.135-140
    • /
    • 2013
  • In this paper, we discussed about the volume monitoring system of a landfill facility. We proposed the waste volume calculation method using the point cloud of the surface of three dimensional object by measurement of the point cloud by the three dimensional scanner, which is based upon the robot technique. This computes not only the quantity of waste volume for continuos monitoring but also it helps not only to predict the evaluation factor of the usable age of a landfill. facility. Furthermore, the measuring system of waste volume was applied to the landfill facility in Ansung city.

Repeatability Study of a Pneumatic Dispensing System for Bio-Applications (바이오 응용을 위한 공압 디스펜싱 시스템의 반복 정밀도 연구)

  • Lee, Sang-Min;Choi, In-Ho;Kim, Joon-Won
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.53-58
    • /
    • 2012
  • Biological and chemical assays(e.g., clinical tests for medical diagnosis) are needed to handle small liquid volume with high accuracy and high reliability. Many micro-dispensing systems using various actuation methods have been developed and applied. In this research, we confirm repeatability of the cartridge-type dispensing system with various measuring methods for guarantee of an acceptable reliability. We systematically examine the dispensed volume variation and dispense rate during 500,000 shots of sequential actuation. Using the same method, we confirm the repeatability of dispensed volume while varying operating conditions and design parameter(i.e., outlet size) of the dispensing system. Also, we examine the consistency of the dispensed volume of droplet while varying the operating pressures. Furthermore, we repeatedly measure differences between an actual dispensed volume and a target volume. According to our results, it is expected that the stable and reliable performance of our dispensing system can effectively be used in various applications containing bio-solutions.

Quality Characteristics of Muffins Containing Bokbunja (Rubus coreus Miquel) Powder (복분자 분말을 첨가한 머핀의 품질특성)

  • Ko, Dae-Young;Hong, Ha-Young
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.6
    • /
    • pp.863-870
    • /
    • 2011
  • In this study, muffins containing Bokbunja, popularly known as a psychological activator and functional material, was made, and its preference levels and qualitative characteristics were evaluated. We measured the height and weight of muffins containing Bokbunja powder. Height decreased when the volume of Bokbunja powder increased (p<0.001). When weight was measured, there was no meaningful difference between the samples, although the Bokbunja powder-containing samples were heavier than the samples not containing Bokbunja powder. When we measured the weight and specific volume of the muffins containing Bokbunja powder, the specific volume decreased when the amount of Bokbunja powder increased (p<0.001). The moisture and pH levels of the muffins not containing Bokbunja powder were 17.04% and pH 8.59, respectively. As the volume of Bokbunja powder increased, the moisture level of Bokbunja muffin increased while the pH decreased, and there was a significant difference (p<0.001). As a result of measuring the colors of muffins, the brightness of the muffins containing Bokbunja powder decreased, and the muffins showed decreased yellowness index and increased redness. In measuring the texture of Bokbunja muffins, hardness decreased as the volume of Bokbunja power increased (p<0.001). Further, springness of the muffins decreased as the volume of Bokbunja powder increased, and there was a significant difference (p<0.001). The chewiness of the muffins not containing Bokbunja powder was higher than any other muffin sample, and there was a significant difference between the samples (p<0.001). Further, the cohesiveness of the decreased as the volume of Bokbunja powder increased (p<0.001). Bokbunja muffins showed a lower gumminess index than those not containing Bokbunja powder (p< 0.05). When the sensual qualities of the muffins were measured, the color, flavor, taste, and softness of all of the samples showed significant differences (p<0.001), and the muffins containing 8% Bokbunja powder showed the highest sensual quality indexes. When the general preference level for the muffins was measured, the muffins containing 8% Bokbunja powder showed the highest index, 7.03${\pm}$0.96. Based on this result, the ideal volume of Bokbunja powder when making muffins is 8%.

Study on the Measuring Method and Reliability of Top Clearance of Variable Swashplate Type Compressor (가변 사판식 압축기의 탑 클리어런스 측정 방법 및 신뢰성 확보에 관한 연구)

  • Kim, Young-Shin;Na, Seung-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.89-94
    • /
    • 2016
  • In this experimental study, the effects of top clearance on the performance of automotive a/c compressor were studied. Top clearance measuring device was also developed to ensure the reliability using vacuum conditions to secure constant control of top clearance without external environmental influence. Our results revealed that the improvements in compressor performance according to different top clearance values using the same compressor and same operator were about 4.12% at 800 rpm and about 7.8% at 2,000 rpm in 0.243~0.252 mm of top clearance compared to 0.431~0.456 mm of top clearance. To confirm the consistency in measuring top clearance affecting compressor performance, the top clearance measuring device was developed in this study using a vacuum pump. After performing reliable tests repeatedly, the distribution of measuring values under this device was within 0.99~1.83%, indicating that the constant test data in compressor performance was not affected by any other external environment.

The Effects of VMD Components on Consumers' Store Image and Preference - focused on interior color and product volume of clothing shop- (VMD 구성요소가 점포이미지와 선호도에 미치는 영향 -의류매장의 실내색상과 상품수량을 중심으로-)

  • Lee, Mi-Sook
    • Korean Journal of Human Ecology
    • /
    • v.18 no.1
    • /
    • pp.247-257
    • /
    • 2009
  • The purpose of this study was to examine the effects of interior color and product volume of clothing shop on consumer's store image and preference for a clothing shop. The research methodology was a survey questionnaire and the subjects were 516 university students in Daejeon, Korea. The measuring instruments were stimuli and self-administrated questionnaire. The stimuli were 7 pictures of clothing shop including interior color and product volume variables, and the self-administrated questionnaire consisted of semantic differential scales for store image, store preference, and subject's demographic attribution. The data were analyzed by t-test, ANOVA, MANOVA, Duncan's multiple range test, based on SPSS program The results were as follows: first, in clothing shop's interior colors affecting store image and preference for clothing shop, white color gave a casual, sophisticated, characteristic, and attractive image to the shops, and brown color gave an elegant, sophisticated image, while black color gave a sophisticated, uncomfortable image, and gray color gave a less positive image to them than other colors. Subjects preferred white, brown, and black color in the order. Second, clothing shop's products volume also affected consumers' store image and preference. Its small volume gave a more sophisticated, elegant image than other volume levels, and subjects preferred small and medium volume of clothing products to their large volume. Third, the effects of shop's interior color and clothes' product volume on store image were different depending on subject's sex. The results revealed that clothing shop's interior color and product volume are important VMD components affecting consumer's store image and preference, and consumer's sex has to be considered to understand the effects of VMD components on clothing shop image.

Development of the system for error evaluation in coordinate measuring machines (3차원 좌표 특정기의 오차 평가 시스템 개발)

  • ;M.Burdekin;G.Peggs
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.116-120
    • /
    • 1991
  • Technique of length measurement error is widely used in the accuracy assessment of CMMS(Coordinate measuring machines) and machine tools, as it is simple and direct measurement within the working volume of a machine. In this paper, a new method is proposed for the evaluation of the length measurement error in relation to the volumetric accuracy. lD, 2D, and 3D measuring lines are considered for recpective length measurement error: 1D, 2D, and 3D length measurement uncertainties are evaluated from volumetric accuracy. The relationship between the volumetric accuracy md length measurement error to is discussed. PC based system for length measurement error evaluation and simulation is developed.

  • PDF