• Title/Summary/Keyword: measuring volume

Search Result 795, Processing Time 0.027 seconds

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF

A Development of Floating Dock Control Simulator for Skid Launching System (Skid Launching System을 위한 Floating Dock Control Simulator의 개발)

  • Kim, Jee-Hun;Lee, Jang-Yong;Park, Sok-Chu
    • Journal of Navigation and Port Research
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • Since the shipbuilding industry is at its peak to assimilate the large volume of orders in recent years, the Floating Dock has been an alternative to the dry dock which takes a certain period of time to build. Hence the use of Floating Dock is steadily increasing. Since the Skid Launching System(SLS) is used in Floating Dock, the balancing of the ship while launching is important and achieved by adjusting the Ballast tank of the Floating Dock. In this paper a Floating Dock Control Simulator for SLS is developed through the on-line interface of VRC(Valve Remote Control), Tank Level & Draft Measuring System and Valve Control algorithm on Simulation Tank Plan.

Analysis of Differences in Indoor Environment and Fatigue Response According to Ventilation in Lecture Hall (대형강의실의 환기여부에 따른 실내환경과 피로감 반응의 차이분석)

  • Oh, Ye-Seul;Hwang, Jin-A;Choi, Yoon-Jung
    • Korean Journal of Human Ecology
    • /
    • v.19 no.2
    • /
    • pp.417-428
    • /
    • 2010
  • The purpose of this study was to analyze differences of the indoor environment and student's fatigue response according to ventilation in university lecture hall. The experiments consisted of measuring the indoor environmental parameters and a survey of student's responses. The experiments were in the lecture hall that the actual lecture was conducted in on the $25^{th}$ of May 2009 (not opening windows and door- A) and the $1^{st}$ of June 2009 (opening windows and door- B). The experimental variable was ventilation by opening the windows and door, and the controlled conditions were indoor temperature by air conditioner, volume of the microphone and VTR, lighting conditions and teaching method. The results are as follows: 1) The indoor temperature was maintained in controlling A, B but the $CO_2$ and relative humidity of A (average 3579ppm, 62.6%) was higher than B (average 1697ppm, 48.1%). 2) There were differences in the student's subjective responses and student's fatigue responses between A and B. 3) Therefore, it was found that ventilation by opening the windows and door was a valid way to improve the relative humidity and to reduce $CO_2$ in the lecture hall.

Simultaneous Determination of Gumiganghwal-tang and Its Anti-atherosclerotic Effect (구미강활탕의 성분 분석 및 LDL 산화억제 효능 연구)

  • Kim, Ohn Soon;Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.17 no.3
    • /
    • pp.165-176
    • /
    • 2013
  • Objective : The purpose of this study was to establish the simultaneous analysis for six compounds in Gumiganghwal-tang (GMGHT, Jiuweiqianghuo-tang) and to investigate the anti-atherosclerotic effects of GMGHT in vitro. Methods : The column for separation of six compounds was used Luna $C_{18}$ column and maintained at $40^{\circ}C$. The mobile phase for gradient elution consisted of two solvent systems, 1.0% acetic acid in water and 1.0% acetic acid in acetonitrile. The analysis was carried out at a flow rate of 1.0 mL/min with pothodiode array (PDA) detection at 254, 280, and 320 nm. The injection volume was 10 ${\mu}L$. The antioxidant activities of GMGHT were evaluated by measuring free radical scavenging activities on 2,2'-Azinobis-3-ethyl-benzothiazoline-6-sulfonic acid (ABTS) and 1-1-diphenyl-2-picrylhydrazyl (DPPH). The inhibitory effects on low-density lipoprotein (LDL) oxidation were evaluated by the formation of thiobarbituric acid relative substances (TBARS), relative electrophoretic mobility (REM), and fragmentation of apolipoprotein B (ApoB)-100. Results : Calibration curves were acquired with $r^2{\geq}0.9998$. The contents of liquiritin, ferulic acid, baicalin, baicalein, glycyrrhizin, and wogonin in GMGHT were 1.784, 1.693, 37.899, 0.258, 1.869, and 0.034 mg/g, respectively. The GMGHT showed the radical scavenging activity in a dose-dependent manner. The concentration required for 50% reduction ($RC_{50}$) against ABTS and DPPH radicals were 72.51 ${\mu}g/mL$ and 128.49 ${\mu}g/mL$. Furthermore, GMGHT reduced the oxidation properties of LDL induced by $CuSO_4$. Conclusion : HPLC-PDA is considered as an available and convenient method for quality control and standardization of GMGH and GMGHT has potentials on anti-atherosclerosis by anti-oxidative effect and suppressive effect on LDL oxidation.

A case study on the costume making process of stop motion animation characters (스톱모션 애니메이션 캐릭터 의상제작과정에 관한 사례 연구)

  • Kim, Ki Hoon;Suh, Ji Sung
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.5
    • /
    • pp.655-663
    • /
    • 2012
  • Due to increased interest in character costumes, the field of animation character costume design is gradually developing into a specialized domain. The costume-making process for animation characters presents many differences from the costume-making process for regular apparel. However, there remains insufficient research on the actual process of making the character costumes used in stop motion videos both in Korea and abroad. The purpose of this study is to establish a costume design process for animation characters. Furthermore, this study presents a case study on the costume planning and making process for 3D stop motion animation characters. The character costume-making process was segmentalized into the following stages: character analysis stage, character modeling stage, and character costume making stage. In the character analysis stage, the investigator analyzed the character's movements, designed the character images, and analyzed the movements and motions of the animation characters. After completing character modeling, this study proposed a method for making the character costume. The style of the character costume was designed, and the structural design reflected the position and size of joints as well as the angle of movements. The patterns of the character costume were produced through dimensional tailoring after measuring the body size of the character. Afterward, the costume was completed after passing through the fitting and revision stages. The clothing material was selected to fit the colors and feelings shown in the illustration. To complete the costume after comparing it with the initial illustration, it was revised based on the assessment of its volume and overall atmosphere.

Thyroid Function after Postoperative Radiation Therapy in Patients with Breast Cancer

  • Wolny-Rokicka, Edyta;Tukiendorf, Andrzej;Wydmanski, Jerzy;Roszkowska, Danuta;Staniul, Boguslaw;Zembron-Lacny, Agnieszka
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.10
    • /
    • pp.4577-4581
    • /
    • 2016
  • Objective: The aim of this study was to assess thyroid function in breast cancer patients exposed to therapeutic external beam radiation. The focus was on possible progressive changes and any relationships between the incidence of primary hypothyroidism, the time required to become hypothyroid, and factors such as chemotherapy, hormonotherapy and immunotherapy. Materials and Methods: Seventy females undergoing 3D conformal and IMRT radiation therapy for breast cancers were enrolled in a non-randomized prospective study. The patients was divided into two groups: those after mastectomy or breast conserving surgery (BCS) were irradiated to a scar of the chest wall/breast and the ipsilateral supraclavicular and the axillary areas (supraclavicular radiotherapy group - SC-RT group - 32 patients) and the control group receiving adjuvant chest wall/breast RT only (BCT group - 38 patients).The total doses were 50.0 to 70 Gy in 5 to 7 weeks. The median follow-up term was 24 months (range, 1-40 months). Thyroid function was evaluated by measuring thyroid stimulating hormone (TSH), free thyroxine (fT4), and free triiodothyronine (fT3) levels. The minimum, maximum and mean thyroid gland doses for 20 Gy (V20) were calculated for all patients. Results: Statistically significant results were obtained for the SC-RT group. Two yearsa fter the end of RT the chance of an event was increased in 6% of the population (p=0.009) in the SC-RT group. In the BCT group no significance was noted. No statistically significant differences were found for V20, chemio-, immunotherapy and hormonotherapy or Ki67 values (p=0.12). No significant results were obtained for development of hypothyroidism and clinical factors (age, thyroid volume, treatment modalities). Conclusion: Radiotherapy is associated with a higher incidence of thyroid toxicity in breast cancer patients. Routine thyroid function monitoring should be recommended in such cases.

Estimation of Transpiration Rate with a Metering Pump and its Application in Soilless Culture System (정량펌프를 이용한 무토양재배시스템의 증산량 추정 및 그 응용)

  • Son, Jung-Eek;Park, Jong-Seok
    • Horticultural Science & Technology
    • /
    • v.16 no.1
    • /
    • pp.25-26
    • /
    • 1998
  • Nutrient supplying by a metering pump often produces the inaccuracy in the rate of inflow than expected. In this study, we developed the transpiration estimation system using the metering pump to measure the continuous supplying rate as well as to estimate the accurate transpiration rate. The system showed the stable characteristics by eliminating the fluctuations in the head loss of nutrient tank. The direct proportionality between the supplying time and the supplied nutrient solution was obtained. The exact correlation between the integrated solar radiation and the transpiration rate using the system was calculated, and correlation coefficients between the two factors were 0.98 in the NFT system and 0.92 in the aggregate system. This results suggest that the integrated solar radiation was an important factor to directly decide the supplying volume of nutrient solution in soilless culture system. The deveolped system using the metering pump in the study was able to control the supply of the nutrient solution to the crops adjusting to the variation of solar radiation.

  • PDF

A Study on Surface Properties of Ablative Materials from 0.4MW Arc-Heated Wind Tunnel Test (0.4MW 아크 가열 풍동 시험을 통한 삭마 재료의 표면 특성 연구)

  • Kim, Nam Jo;Oh, Philyong;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.12
    • /
    • pp.1048-1053
    • /
    • 2015
  • Ablative materials in a thermal protection system for atmospheric re-entry suffers from the most severe heat fluxes and temperatures, which induces surface recession in the thickness direction. In this paper, a 0.4MW arc-heated wind tunnel is operated to test for ablative materials, and a non-contact three-dimensional surface measuring system is used to evaluate the different surface characteristics of them. In particular, by postprocessing the three-dimensional image data, the surface roughness and recession of ablative materials can be calculated before and after the wind tunnel test. Moreover, the surface properties are analyzed quantitatively by comparing volume and mass losses of the test specimens.

Perturbation of Dose Distributions for Air Cavities in Tissue by High Energy Electron (고(高) 에너지 전자선(電子線) 치료시(治療時) 체내(體內) 공동(空洞)으로 인(因)한 선량분포(線量分布)의 변동(變動))

  • Chu, S.S.;Lee, D.H.;Choi, B.S.
    • Journal of Radiation Protection and Research
    • /
    • v.1 no.1
    • /
    • pp.22-30
    • /
    • 1976
  • The perturbation of dose distribution adjacent to cavities in high energy electron has shown that the percentage of dose increase varies markedly as a function of the build-up layer, the length and thickness of the cavities, and the electron energy. The dose distribution showed that cavities similar in size to those encountered in the head and neck measured by industrial film dosimetry and corrected by ionization chambers. The most increased doses by measuring are resulted in a localized dose of up to 130% of that measured at the depth of maximum dose within a homogeneous tissue equivalent phantom. The measured values and correction factors of dose perturbation due to air cavities showed in diagrams and would be summarized as follows. 1. In $8{\sim}12MeV$ electron beams, the most marked dose is observed when the build-up layer thickness is 0.5cm and cavity volume is $2{\times}2{\times}2cm^3$. 2. The highest dose point is located under cavity when the energy is increased and cavity length is longer. 3. The cavity length at which the maximum percentage dose occurs decreases with increasing energy. 4. The highest percentage cavity doses are obtained when the energy is high, the build-up layer is thin, the thickness of the cavity is large, and the length of the cavity is approximately 1 to 3cm. 5. The doses of upper portion of cavity are less than the standard dose distribution as 5 to 10%. 6. The maximum range of electron beam are extended as much as thickness of cavity. 7. A cavity having a length of 5cm closely approximates a cavity of infinite length.

  • PDF

The Investigation Study of Compaction Density by Waste Composition Change in Landfill Site (매립장의 반입쓰레기 성상변화에 따른 다짐밀도 조사연구)

  • Jung, Byung-Gil;Choi, Young-Ik;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.397-403
    • /
    • 2008
  • The purpose of this study is to investigate weighted compaction density according to a leading density in truck, a compaction density of solid waste and composition ratios of solid waste fur calculation of a capacity of the landfill sites. The experiments for calculations of in-place density at landfill site have been conducted in S landfill site at B City. The size of vessel for measuring the compaction density was $1m^3(1m{\times}1m{\times}1m)$. The experiment tests have been carried out methods (1 time for bulldozer and 4 times for compactor) that do contain all of specification at the landfill site. Average of the loading density at the landfill site was $0.264\;ton/m^3$ ($0.113{\sim}0.487\;ton/m^3$). When the loading density for each compositions was compared, the composition of the highest average loading density ($0.474\;ton/m^3$) was miscellaneous wastes. The composition of the lowest average loading density ($0.120 ton/m^3$) was general solid waste. The reported results indicated that the compaction density at the landfill site was $0.538\;ton/m^3$, which was calculated with weighted incoming ratios of compositions. The ranges of the density for each composition were from $0.021\;ton/m^3$ to $0.221\;ton/m^3$. When the compaction density for each composition was compared, the composition with the highest average compaction density ($0.221\;ton/m^3$) was miscellaneous wastes. The composition with the lowest average compaction density ($0.021\;ton/m^3$) was general solid wastes.