• Title/Summary/Keyword: measuring volume

Search Result 795, Processing Time 0.03 seconds

Accuracy Validation of Urinary Flowmetry Technique Based on Pressure Measurement (수압 측정에 기반하는 요류검사의 정확도 검증)

  • Choi, Sung-Soo;Lee, In-Kwang;Kim, Kun-Jin;Kang, Seung-Bum;Park, Kyung-Soon;Lee, Tae-Soo;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.198-204
    • /
    • 2008
  • Uroflowmetry is a non-invasive clinical test useful for screening benign prostatic hyperplasia(BPH) common in the aged men. The current standard way to obtain the urinary flow rate is to continuously acquire the urine weight signal proportional to volume over time. The present study proposed an alternative technique measuring pressure to overcome noise problems present in the standard weight measuring technique. Experiments were performed to simultaneously acquire both weight and pressure changes during urination of 9 normal men. Noise components were separated from volume signals converted from both weight and pressure signals based on the polynomial signal model. Signal-to-noise ratio was defined as the ratio of the energies between signal and noise components of the measured volume changes, which was 8.5 times larger in the pressure measuring technique, implying that cleaner signal could be obtained, more immune to noisy environments. When four important diagnostic parameters were estimated, excellent correlation coefficients higher than 0.99 were resulted with mean relative errors less than 5%. Therefore, the present pressure measurement seemed valid as an alternative technique for uroflowmetry.

Study on the Improvement for Measuring Procedures of Volumetric Pressure Plate Extractor (체적압력판추출기의 측정법 개선에 관한 연구)

  • Yoo, Kun-Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4C
    • /
    • pp.185-191
    • /
    • 2010
  • Volumetric pressure plate extractor (VPPE) can be used for measurement of the soil-water characteristic curve in the laboratory using the axis-translation technique. The volume of extracted water from the soil specimen in VPPE can be measured continuously during the test without stoppage of air pressure for the measurements. However, the water volume measurement in VPPE using an air trap, a ballast tube, a burette, and a vacuum device so as to maintain a constant pore-water pressure in the soil specimen, is quite complicated and tedious. In order to improve the measuring problems of VPPE, a modified volumetric pressure plate extractor (MVPPE) was developed and tested on residual soil specimens. In addition, the modified apparatus can measure the volume of the extracted water using both Method A and Method B of ASTM D 6836-02 depending on the range of matric suction. Measuring principles and the improvements of MVPPE and typical results obtained from the tests are discussed in the paper.

Performance Evaluation for Coordinate Measuring Machine using Design of Experiments (실험계획법을 이용한 3차원 좌표 측정기의 성능 평가)

  • Lee, Seung-Pyo;Ha, Sung-Kyu
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.133-139
    • /
    • 2008
  • With the increasing demand for higher production quality and growing competition in the global market, coordinate measuring machine(CMM) has been widely used in industry to improve the efficiency and effectiveness of measurement. In this paper the performance evaluation of coordinate measuring machine is proposed using design of experiments. A factorial design is applied to carry out the performance test proposed by ISO 10360 with a length bar and to investigate CMM measurement errors associated to orientation and length in the work volume. The determination of the significance of effects in an experiment is made through the analysis of variance(ANOVA). The results show that the proposed method is suitable to analyze the factors which affect the CMM measurement performance.

제너 다이오드를 이용한 공기 유속계측 장치개발

  • 김영재;김희식;조흥근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.496-500
    • /
    • 1996
  • An air flow measurement device is proposed. The thermal characteristic of a semiconductor element is adopted as a cooling parameter of thermal convection rate. The difference between forced convection and natural convection of two Zener diodes results enough difference in temperature. Experiment at various air flow conditions shows the measuring capability of the air flow in a duct. This measuring device has some merits, such as a reliability n hard field condition, simple circuit for signal processing, small volume of the element, less air flow resistance, independance of various ai temperature. The experimental result shows that it is an exact and usefull air flow measurement device.

  • PDF

A development of traffic information detection using camera

  • 김양주;한민홍
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1995.04a
    • /
    • pp.316-323
    • /
    • 1995
  • This paper presents an image processing technique to get traffic information such as vehicle volume, velocity, and occupancy for measuring the traffic congestion rate. To obtain these information, two horizontal lines are previously set on the screen. A moving vehicle is detected using the gray level difference on each line, and also template matching method at night. Threshold values are determined by sampling pavement grey level, and updated dynamically to cope with the change of ambient light conditions. These technique is successfully used to calculate vehicle volume, occupancy, and velocity. This study can be applied to traffic signal control system for minimizing traffic congestion in urban areas.

  • PDF

The Utilization of Converter Slag as Aggregates for Concrete (콘크리트용 골재로서 전로슬래그의 활용)

  • 천승환;문한영;유정훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.379-382
    • /
    • 2000
  • In this paper, we evaluated the suitability of converter slag as concrete aggregate by measuring physical and chemical characteristics of converter slag. The converter slag mainly contains SiO₂and CaO as the chemical composition. The reaction with water and a little of free CaO in the slag causes slag's volume to expanse. Therefore, we used several aging method in order to decrease the characteristics of slag volume expansion. Then the compressive strength of concrete with the converter slag aggregate is measured.

  • PDF

A Study on the Classification of Brassiere Cups by Breast Volume Measurement Values on Women in their Twenties (20대 여성의 유방 부피 계측치에 따른 브래지어 컵의 분류)

  • Park, Yu-Sin;Kim, Seon-Mi;Kim, Eun-Ran
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.93-104
    • /
    • 2004
  • The research subjects of this study were 30 unmarried Korean women from 20 to 29 who had never had an operation on their breast. Measurement method using plaster breast mold was used for measuring their volume of breast. The correlation between their breast volume and the methods to set up brassiere cups with the existing method and with their circumference of breast was analyzed using KendalI's Coefficient. which was to figure out a method which had a bigger correlation with the volume of breast between the method to set up brassiere cups using the existing method and the method using the circumference of breast. The results analyzed showed that the coefficient of correlation between the existing method and the volume of breast was .12 and the significance level was .45. They didn't have any correlation. On the other hand. the coefficient of correlation between the circumference of breast and the volume of breast was .82. which was very high values and the significance level was very high .0001. Therefore. it turned out that it was difficult to set up brassiere cups by using the existing method and it was easier and more reliable to set up the cups by using the circumference of breast.

Case Study of Immersed Tunnel Instrumentation Management Using Wireless System (지중무선 시스템을 이용한 침매터널 구간 계측관리 사례연구)

  • Han, Sang-Wook;Kim, Byung-Hee;Han, Byung-Won;Lee, Gye-Chun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.768-773
    • /
    • 2009
  • Measuring method being applied for off-shore works is performed by using data logger or manual measuring instrument with wiring the cable connected from the sensor up to the position where measuring is allowed.(upper part of embankment or marine structure) Measuring management by using existing measuring method may be acceptable on the condition that the ground deformation volume(vertical, horizontal) is generally minimal and the site condition is good. But loss of measuring instrument, sensor cable failure or cutting is taken place frequently due to significant change of ground behavior caused by an external force change(embankment, excavation) under very soft ground condition(N value below 0-4). In case of the marine works, in particular, loss rate of measuring instrument is highly represented due to the factors of working barge anchoring, constructional interference and natural disaster. In order to solve these problems, measuring management was performed with employing underground wireless system at the immersed tunnel site. Measuring data was obtained freely under the marine environment by using underground wireless communication and cable cutting potential by ground behavior could be reduced. Measuring cost savings and its installation convenience were maximized by way of off-shore tower installation or cabling and by minimizing constructional interference of off-shore working barge. This case of measuring management was accomplished successfully.

  • PDF