• Title/Summary/Keyword: measuring volume

검색결과 795건 처리시간 0.045초

국토정책이 지역 간 인구이동에 미치는 영향에 대한 프로토타입 모형 개발 (Prototype Model Building Reflecting Impact of National Territorial Policies towards the Interregional Migration)

  • 최남희;안유정;이진희;김경미;송미경;이만형
    • 한국시스템다이내믹스연구
    • /
    • 제11권4호
    • /
    • pp.117-142
    • /
    • 2010
  • National territorial policies require a series of dynamic simulations, which would facilitate effectiveness measuring and forecasting works geared towards territorial policies under consideration or implementation. This paper aims at designing an integrated prototype for the proposed territorial policies. After the simulation exercises for the Ochang Industrial Complex(OIC) in Chungbuk Province, this study firstly finds meaningful mismatch phenomena between housing and population increases as the in-migration time lag seems inevitable even after the housing construction is in a mature state. Secondly, the OIC development exerts more significant impact on the number of employees than that of business units. Thirdly, in- and out-migration orders are different during the first and second stages of OIC development. That is, Chungbuk Province records the largest in terms of in-migration volume, followed by the Capital and Non-Capital Regions. Even though Chungbuk Province ranks the top position in the out-migration volume, the rank of the Capital and Non-Capital Regions is reversed: the our-migration volume towards the Non-Capital Region outruns that of the Capital Region.

  • PDF

지상과 수중에서 뇌졸중 환자의 호흡기능 변화 (Changes in the Respiratory Function of Stroke Patients on the Ground and Immersed under Water)

  • 김주승;박민철
    • PNF and Movement
    • /
    • 제16권3호
    • /
    • pp.389-395
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate whether the respiratory function of patients with stroke was different on the ground and under water. Methods: We recruited 14 adults who had experienced a stroke (12 male, 2 female) for our study. We measured forced vital capacity, forced expiratory volume at one second, maximum inspiratory pressure, and maximum expiratory pressure when the participants breathed on the ground and under water. On the ground, the participants were safely supported using a table and chair and were measured in a standing posture. For measuring under water, the participants were immersed in water in a standing position to clavicle height. The participants were measured while standing, and the assistant supported them when they needed help. The collected data were analyzed by a paired t-test. Results: Forced vital capacity and forced expiratory volume at one second were significantly lower in water than on the ground when breathing at maximum. Maximum inspiratory pressure was not significantly different when standing on the ground or in water, but maximum expiratory pressure was significantly higher in water than on the ground. Conclusion: It has been confirmed that the hydrostatic pressure affecting stroke patients immersed in water affects the forced expiratory volume at one second while reducing the forced vital capacity and increasing the maximum expiratory pressure.

Correlation between the Diaphragmatic Contraction Pressure and the Slow Vital Capacity

  • Lee, Jae-Seok;Han, Dong-Wook;Kang, Tae-Wook
    • 대한물리의학회지
    • /
    • 제14권3호
    • /
    • pp.47-53
    • /
    • 2019
  • PURPOSE: This study measured the external pressure on abdomen during maximal inspiration. The study determined the correlation between the diaphragmatic contraction pressure and the lung capacities to verify whether or not the measured pressure values can represent diaphragmatic contractility. METHODS: The study included 32 healthy subjects (16 males and 16 females). The researchers fabricated their own diaphragmatic pressure belt (DiP Belt) to measure DCP. DiP Belt device was fixed on the front of the abdomen and the diaphragmatic contractility was measured during maximal inspiration. The lung capacities were measured using a portable digital spirometer device (Pony Fx, COSMED, Italy). A digital spirometer is a device that is used to test the flow of air entering and exiting the lungs. RESULTS: DCP showed significant positive correlations with vital capacity (VC), inspiratory reserve volume (IRV) and inspiratory capacity (IC). Among values of lung capacities, IC showed especially strong positive correlations with the DCP (r =.714, p<.010). For the males, DCP showed significant positive correlations with IRV and IC, and DCP showed significant negative correlation with the expiratory reserve volume (ERV). For the females, DCP showed significant positive correlation with tidal volume (VT), but any significant correlation was not found with any of the other values of lung capacities. CONCLUSION: DCP showed high correlations with IRV and IC associated with inspiratory capacity. Therefore, The DiP Belt can be looked upon as a simple device that is very useful for measuring diaphragmatic contractility.

AMR 센서를 이용한 교통량 계측장치 개발 (Development of a Traffic Volume Measuring Device Using AMR Sensor)

  • 강문호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2385-2387
    • /
    • 2002
  • 종래 도로상의 차량검지기들은 기후변화 및 도로환경의 변화, 물리적인 변화에 영향을 받아 감지의 정확도가 떨어져 신뢰도 높은 교통정보를 생성하기가 어렵고, 제품의 가격이 고가이며, 설치 및 유지, 보수에 많은 비용과 인력이 요구된다. 본 연구에서는 종래의 차량 검지기가 지니는 문제점들을 해결하여 어떠한 환경하에서도 신뢰성 있는 차량 주행정보를 제공하며 동시에 유지, 보수 비용이 저렴한 검지기로서 AMR(Anisotropic Magneto-Resistive) 센서를 이용하여 도로상의 차량 이동에 따른 지구자기장(Earth Magnetic Field) 변화를 감지하고 차량의 이동상태를 파악하는 교통량 계측장치를 제시한다.

  • PDF

저압다심케이블에서 충진물(개재물)이 절연저항에 미치는 영향 분석 (The Analysis of change of insulation resistance by filler on low voltage multi core cables)

  • 고영훈;박의석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.71-72
    • /
    • 2007
  • The insulation is a important part of cable. In thisb paper, measured the insulation resistance for analysing of change of insulation resistance by filler on low voltage multicore cables. The insulation resistance is not effected by only insulation material, but also filler material. The insulation resistance is different with measuring before filling and after filling by filler. When develope the new filler or cable, the volume resistance of filler must be considered.

  • PDF

Measurement and Scale Effects of Digitized Virtual Human Head

  • Takakazu, Ishimatsu;Chan, Tony
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.89.1-89
    • /
    • 2001
  • Measurement of complex surfaces without touching is desirable in several fields. This arises mainly for measurement of complex surfaces including those surfaces that deform during touch. Our research presented in this paper describes the use of a 3D digitizer for scanning 3D objects. The use of such a device, in addition to proper calibration, requires proper scaling in all three dimensions. We propose measurement techniques to measure various aspects of the surface circumference, area and volume. We also present experiments from using a 3D Minolta digitizer for measuring 3D human heads.

  • PDF

3차원 재구성법을 이용한 수복물의 정량적 미세누출도 측정 (NEW QUANTITATIVE MEASURING TECHNIQUE FOR MICROLEAKAGE OF THE RESTORED TOOTH THROUGH 3D RECONSTRUCTION)

  • 하상윤;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.413-422
    • /
    • 2004
  • Established microleakage tests have their own disadvantages. In this study, 3D reconstruction method was tried to overcome these disadvantages. Four types of microleakage tests were used and relationships among them were estimated: penetrated dye volume: marginal adaptability: degree of dye penetration and relative penetrated length to cavity wall. Twenty-four Class V cavities were bulk filled with composite (Esthet X) following surface treatments: N group (no treatment): E group (etching only): T group (etching + Prime & Bond NT). 50% silver nitrate was used as a dye solution after thermocycling ($5^{\circ}C{\;}&{\;}55^{\circ}C$, 1.000 times). Teeth were serially ground with a thickness of 0.2 mm. Volume of dye penetration was estimated from a three-dimensionally reconstructed image with a software (3D-DOCTOR). Percentage of margin without gap was estimated from SEM and degree of dye penetration and the relative length of dye penetration to overall cavity wall were also estimated. ANOVA and Scheffe test for dye volume, Kruskal-Wallis and Mann-Whitney test for marginal quality, Spearman's rho test for checking of relationships among methods were used. The results were as follows: 1. Dye penetration could be seen from several directions, furthermore, its volumetric estimation was possible. 2. Reverse relationship was found between dye volume and marginal quality (r = -0.881/ p = 0.004). 3. Very low relationship was seen between dye volume and two-dimensional tests (degree of dye penetration and relative length). However, 2D evaluation methods showed high relationship (p = 0.002-0.054) each other. 4. Three times vertical section could be recommended as a 2D test.

기체용적계를 이용한 분동식 압력계용 기준분동의 새로운 부피측정 방법 (New Method of Volume Measurement for Reference Weights of a Pressure Balance Using a Gas Pycnometer)

  • 이용재;이우갑;모하메드;박연규;오재윤
    • 한국진공학회지
    • /
    • 제22권5호
    • /
    • pp.231-237
    • /
    • 2013
  • 본 연구에서는 분동식 기준압력계의 기준분동(reference weight)의 부피를 측정하는 새로운 측정방법인 기체용적계(gas pycnometer) 측정방법을 제안하였다. 제안된 측정방법에 의한 측정결과로서 기준분동 1 kg, 2 kg, 5 kg에 대한 부피 측정불확도는 신뢰수준 95%에서 0.2%를 나타내었다. 기체용적계의 주요 장치는 샘플용기와 팽창용기, 정밀압력계, 정밀온도계, 진공펌프로 구성되며, 측정 원리는 일정한 용기 내에 들어 있는 일정한 양의 기체의 압력과 부피는 서로 반비례한다는 보일(boyle's law)의 법칙을 용용하였다. 본 결과는 현재까지 문헌이나 제조사로부터 기준분동 재질에 대한 밀도값을 적용하여 오던 것을 기준분동의 부피를 직접 측정하여 밀도값을 적용함으로서 압력기준기의 압력 기준값에 대한 국가측정표준의 신뢰도 향상에 기여될 것이다.

Two-Stage Latissimus Dorsi Flap with Implant for Unilateral Breast Reconstruction: Getting the Size Right

  • Feng, Jiajun;Pardoe, Cleone I;Mota, Ashley Manuel;Chui, Christopher Hoe Kong;Tan, Bien-Keem
    • Archives of Plastic Surgery
    • /
    • 제43권2호
    • /
    • pp.197-203
    • /
    • 2016
  • Background The aim of unilateral breast reconstruction after mastectomy is to craft a natural-looking breast with symmetry. The latissimus dorsi (LD) flap with implant is an established technique for this purpose. However, it is challenging to obtain adequate volume and satisfactory aesthetic results using a one-stage operation when considering factors such as muscle atrophy, wound dehiscence and excessive scarring. The two-stage reconstruction addresses these difficulties by using a tissue expander to gradually enlarge the skin pocket which eventually holds an appropriately sized implant. Methods We analyzed nine patients who underwent unilateral two-stage LD reconstruction. In the first stage, an expander was placed along with the LD flap to reconstruct the mastectomy defect, followed by gradual tissue expansion to achieve overexpansion of the skin pocket. The final implant volume was determined by measuring the residual expander volume after aspirating the excess saline. Finally, the expander was replaced with the chosen implant. Results The average volume of tissue expansion was 460 mL. The resultant expansion allowed an implant ranging in volume from 255 to 420 mL to be placed alongside the LD muscle. Seven patients scored less than six on the relative breast retraction assessment formula for breast symmetry, indicating excellent breast symmetry. The remaining two patients scored between six and eight, indicating good symmetry. Conclusions This approach allows the size of the eventual implant to be estimated after the skin pocket has healed completely and the LD muscle has undergone natural atrophy. Optimal reconstruction results were achieved using this approach.