• Title/Summary/Keyword: measuring volume

Search Result 793, Processing Time 0.026 seconds

Measurement of Maxillary Sinus Volume Using Computed Tomography (전산화단층사진술을 이용한 상악동 체적의 측정)

  • Park Chang-Hee;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.63-70
    • /
    • 2000
  • Purpose: To propose a standard value for the maxillary sinus volume of a normal Korean adult by measuring the width and height of the sinus and analyzing their correlation and the difference of the sinus size respectively between sexes, and on the right and left sides. Materials and Methods: Fifty-two (95 maxillary sinuses) out of 20 years or over aged patients who had taken CT in the Department of Dental Radiology, Yonsei University, Dental Hospital, between February 1997 and July 1999 who were no specific symptom, prominent bony septa, pathosis, clinical asymmetry and history of surgery in the maxillary sinus were retrospectively analyzed. Results: The mean transverse width, antero-posterior width, height and volume of the normal Korean adult's maxillary sinuses were 28.33 mm, 39.69 mm, 46.60 mm and 21.90 cm³, respectively. There was a significant sex difference in the sinus volume (p>0.05). In the mean antero-posterior width, height and volume of the sinus, no significant difference was observed between both sides. All four measurements showed a significant correlation between both sides (p>0.0001). The widths and height of the sinus all showed a significant correlation with the sinus volume (p>0.0001). Conclusion : In the Korean normal adult's maxillary sinus, males tended to be larger than females. Except for the transverse width, all of the measurements showed no significant difference between the right and left side, but significant correlations in the four measurements between both sides were observed. Thus, the overgrowth or undergrowth in the unilateral maxillary sinus may suggest a certain pathosis or developmental abnormalities in the maxillary sinus.

  • PDF

The Development of the Components of the Length Measurement Concept in the Procedure of Measurement Using a Ruler

  • Antic, Milica D.;Dokic, Olivera J.
    • Research in Mathematical Education
    • /
    • v.22 no.4
    • /
    • pp.261-282
    • /
    • 2019
  • The research related to testing pupils' achievement in the field of Measurement and Measure in initial teaching of geometry points to an insufficient adoption of the basic components of the length measurement concept among pupils. In order to discover the cause, we looked at the basic components on which the procedure of measuring length using a ruler is based, highlighted the possibilities of introducing the procedure in measuring length, and determined pupils' achievement during the procedure of measuring length using a ruler. The research sample consisted of 145 pupils, out of which 72 were the 2nd grade pupils and 73 were the 4th grade pupils. A descriptive method was applied in the research. The technique we used was testing, and for the statistical data processing we used a χ2 test. The results of the research show that, when drawing a straight line of a given length using a ruler, there is no statistical difference in achievement between the 2nd and 4th grade pupils, nor in the pupils' knowledge regarding drawing a ruler independently, while drawing a straight line of a given length using a "broken" ruler 4th grade pupils are statistically better. The results of the research indicate that pupils' achievement is better in doing standard tasks than in non-standard ones, given that the latter require conceptual knowledge. The components of the concept of length measurement using ruler have not been sufficiently developed yet, and these include: zero-point, partitioning a measured object in a series of consecutive measurement units and their iteration. We shed more light on the critical stage in the procedure of length measurement - the transition from non-standard to standard units and the formation of the length measurement scale. For further research, we propose to look at the formation of the concept of length measurement using the ruler through all its components and their inclusion in the mathematics curriculum, as well as examining the correlation of pupils' achievement in the procedure of measuring length with their achievement in measuring area (and volume).

Accuracy Improvements of DAM-Reservoir Storage Volume Estimation based on GIS (GIS기반에서 댐 저수량 산정의 정확도 향상)

  • Jeong, InJu;Moon, DooYoul;Jung, BeomSeok
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.2
    • /
    • pp.136-144
    • /
    • 2005
  • GIS analyzes various topographic feature in three dimensions using triangulated irregular network (TIN). This paper proposed a method that can analyze topographic features effectively in three dimensions. Method developed in this study can calculate earth-volume, the inundation volume, storage volume etc, effectively. We could reduce error than existing volume calculation methods in computing volume in addition to water level's change about each. Also, the develop method can improve accuracy in measuring the storage of reservoirs. Main result of this paper id to develop a efficient calculation method using contour and elevation data on digital map.

  • PDF

The study of the effect of the diuretic herbal medicine in the Sasang Constitutional Medicine (사상체질별(四象體質別) 이소편(利小便) 약물(藥物)의 효능(效能)에 관한 연구(硏究))

  • Shin, Mee-Ran;Kim, Jung-Yul;Jeon, Jung-Won;Kim, Dal-Rae;Sim, Gyu-Heoun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.15 no.3
    • /
    • pp.187-196
    • /
    • 2003
  • The aim of this thesis is to examine the effect of the diuretics in the Sasang constitutional medicine those are not categorized to the diuretic in the established herbal medicine by the way of measuring the change of body edema and the quantity of body moisture through the inbody test, along with the urine volume taken for 24 hours 1. We medicated the diuretic suggested by the DongyiSuseBowon東醫壽世保元 into the tested group and measured the change of the urine volume, the quantity of body moisture and the degree of body edema. The results are the followings below. 1) Soeumin The change in the urine volume and body moisture showed no responsibility, but the degree of body edema decreased with the responsibility. 2) Soyangin All of the degree of body edema and the urine volume, and body moisture showed decrease. 3) Taeumin The urine volume and body moisture increased but showed no responsibility. Also the degree of body edema decreased within the normal limit which can not be accepted. 4) The medicine of the Sasang Constitutional Medicine can not be simply thought to be the diuretic, but it has the function that excretes the moisture which functions negatively in the body and causes edema, as well as the function of the adjustment of metabolism that preserves the normal amount of moisture. This is the good example which is the concept of the adjustment therapy suggested by The Sasang Constitutional Medicine 2. Through the results above, we can find that the diuretic suggested by The Sasang Constitutional Medicine functions in the way that is differently explained by the herbal medicine.

  • PDF

Research on the characteristics of noise exposure on worker wearing acoustic devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.808-813
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset Noise exposure measurements of 17 operators were performed in 7 call centers and Head and Torso Simulator method in compliance with the ISO Standard 11904-2 was used for the measurement of noise transmitted from the headset Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of Pearson Correlation Analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

  • PDF

플라즈마 디스플레이 패널(Plasma Display Panel) 텔레비전에서의 냉각 소음 저감

  • 김규영;최민구;이덕주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.719-724
    • /
    • 2003
  • The present experimental study deals with noise reduction and improvements in cooling performance in a plasma display panel(PDP) television (TV). To reduce the noise, the effects of installation parameters are studied. The experimental parameters under investigation are the distance between the fan and the rear case of a PDP TV, position of the strut on the fan, and the fan RPM. The variance of RPM is the most significant facto., and a 250 RPM decrease from 910 RPM causes about 4㏈(A) reduction in the system noise. To increase performance, flow characteristics are investigated by using a visualization technique and measuring the volume flow rate. The visualized results show that a radial direction flow due to large system resistance is significant, and an axial velocity oscillation is observed from the measurement of the volume flow rate. To prevent both a radial direction flow and an axial velocity oscillation, sponges are inserted in the space between f3n and the rear case. Inserted sponges improve the volume flow rate of cooling fans up to 32% since they convert a radial direction flow to an axial direction flow. Also an axial velocity oscillation with large amplitude and low RPM disappears. Increasing volume flow rate causes the PDP TV to improve its cooling performance. Additionally the same volume flow rate can be obtained with a decreased fan speed due to the inserted sponge. Noise reductions of 4.2 ㏈(A) at the rear and 1.1 ㏈(A) at the front of the TV are obtained by the decreased RPM. An increase of 10% of the volume flow rate is also achieved by inserting sponges.

  • PDF

Research on the Characteristics and Measures of Noise Exposure on Worker Wearing Acoustic Devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.7
    • /
    • pp.615-621
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset. Noise exposure measurements of 17 operators were performed in 7 call centers and head and Torso simulator method in compliance with the ISO standard 11904-2 was used for the measurement of noise transmitted from the headset. Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of pearson correlation analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

A Study on the Stimulation Transmit of PBDG (PBDG의 자격 전달에 관한 연구)

  • Kim, D.K.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1980-1982
    • /
    • 1999
  • Conductive Langmuir-Blodgett(LB) films have recently attracted much interest from the viewpoint of ultrathin film conductors at the molecular level. The result shows that the Maxwell-displacement-current (MDC) measuring technique is useful in the detection of phase-transitions over the entire range of molecule areas. In this parer, electrical properties of PBDG Langmuir(L) films were investigated using a displacement current measuring technique with pressure stimulation. Displacement current was generated When the Spread volume $150{\mu}{\ell}$ and compression velocity was about 30, 40, 50 mm/min. In the result, it is known that current is generated of higher current peek as compression velocity become faster.

  • PDF

Packing density and filling effect of limestone fines

  • Kwan, A.K.H.;McKinley, M.
    • Advances in concrete construction
    • /
    • v.2 no.3
    • /
    • pp.209-227
    • /
    • 2014
  • The use of limestone fines (LF) in mortar and concrete can in certain ways improve performance and thus has become more and more commonplace. However, although LF is generally regarded as a filler, it is up to now not clear how much filling effect it could have and how best the filling effect could be utilized. Herein, the packing density and filling effect of LF were studied by measuring the packing densities of LF, (LF + cement) blends and (LF + cement + fine aggregate) blends under dry and wet conditions, and measuring the performance of mortars made with various amounts of LF added. It was found that the addition of LF would not significantly increase the packing density of (LF + cement) blends but would fill into the paste to increase the paste volume and paste film thickness, and improve the flow spread and strength of mortar.

A Study on Stimulus Response Characteristic of PBLG and PBDG (PBLG와 PBDG의 자격 응답특성에 관한 연구)

  • Kim, Beyung-Geun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.47-50
    • /
    • 2002
  • The displacemant current measuring system used for detecting the dynamic behavior of monolayers at the air-water interface is described. It basically consists of a film balance, a pair of electrodes connected to each other through a sensitive ammeter. Here, one electrode is suspended in air and the other electrode is placed in the water. With Maxwell-displacement-current-measuring method, the phase transitons of $Poly-{\gamma}-benzyl_{L}$ -glutamate (PBLG) and $Poly-{\gamma}-benzyl_{D}$-glutamate(PBDG) on a water surface were detected. Measured surface pressure, displacement current and dipole moment of monolayers of PBLG and PBDG on the water surface. Also, we measured that compression velocity (30, 40, 50[mm/min]) when the sample spread volume was about 370[ul]-400[ul] and displacement current that occur when differed temperature. From the result, it is known that current is generated in the range of high surface pressures as compression velocity become faster and increase of temperature.

  • PDF