Sensory Characteristics of Green Tea Bread (녹차빵의 품질 특성)

  • 김정숙
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.6
    • /
    • pp.657-661
    • /
    • 1998
  • Green tea powder (3%, 6%, 9%) was added to green tea bread and physicochemical characteristics of green tea bread were investigated. As the result of measuring the pH of the dough, the pH of control was 5.6 and the pH of the investigated. As the result of measuring the pH of the dough, the pH of control was 5.6 and the pH of the samples were 5.34, 5.29 and 5.26 each. As it is seen above, there is no big difference in the pH of the three different dough. Therefore, it could be that the pH of the dough doesn't really affect on the volume of the bread. As the amount of the green powder was changed, the weight of bread, volume of bread, baking loss rate, the color of the surface, the tenderness of the crumb were affected. The 9% of the green powder gave the most distinguishable affect on these factors. As the amount of thee green tea green tea powder caused the change of color. The result of the sensory evaluation showed that the addition of the green tea powder affected significantly on the quality of the bread. Considering the result of the test, 3% of the green tea powder bread is the best for the production of the bread.

  • PDF

Effective Volume of the Korea Research Institute of Standards and Science Free Air Chamber L1 for Low-Energy X-Ray Measurement

  • Chul-Young Yi;Yun Ho Kim;Don Yeong Jeong
    • Progress in Medical Physics
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: To evaluate the effective volume of the Korea Research Institute of Standards and Science free air chamber (KRISS FAC) L1 used for the primary standard device of the low-energy X-ray air kerma. Methods: The mechanical dimensions were measured using a 3-dimensional coordinate measuring machine (3-d CMM, Model UMM 500, Carl Zeiss). The diameter of the diaphragm was measured by a ring gauge calibrator (Model KRISS-DM1, KRISS). The elongation of the collector length due to electric field distortion was determined from the capacitance measurement of the KRISS FAC considering the result of the finite element method (FEM) analysis using the code QuickField v6.4. Results: The measured length of the collector was 15.8003±0.0014 mm with a 68% confidence level (k=1). The aperture diameter of the diaphragm was 10.0021±0.0002 mm (k=1). The mechanical measurement volume of the KRISS FAC L1 was 1.2415±0.0006 cm3 (k=1). The elongated length of the collector due to the electric field distortion was 0.170±0.021 mm. Considering the elongated length, the effective measurement volume of the KRISS FAC L1 was 1.2548±0.0019 cm3(k=1). Conclusions: The effective volume of the KRISS FAC L1 was determined from the mechanically measured value by adding the elongated volume due to the electric field distortion in the FAC. The effective volume will replace the existing mechanically determined volume in establishing and maintaining the primary standard of the low-energy X-ray.

A Morphologic Study of Sasang Constitution (사상인(四象人)의 형태학적(形態學的) 특징(特徵)에 관(關)한 연구(硏究))

  • Lee, Eui-ju;Kho, Byung-hee;Song, Il-Byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.2
    • /
    • pp.181-220
    • /
    • 1998
  • 1. PURPOSE This is a quantitative analysis of Sasang Constitution by measuring human body except face. This study is carried out for the purpose of searching out the theory of Sa-cho and the morphologic theory of Sasang Constitution. 2. METHOD (1) SUBJECTS Subjects are 338 person came to Dept. of Sasang Constitutional Medicine (KyungHee Oriental Medical Center) and Oriental Medicine and Western Medicine Cooperative Health Examination Center (KyungHee Medical Center) from October 1997 to Jauary 1998. The mean age is $41.7{\pm}12.39$. (2) CLASSIFICATION OF SASANG CONSTITUTION QSCCII(Questionnaire for the Sasang Constitution Classification) is used for the Classification of Sasang Constitution. The distributions of Sasang Constitution Classification are Soeumin 83, Soyangin 98, and Taeumin 157. (3) MEASURING INSTRUMENT & ITEMS Length, Breadth, Circomferece, and Skinfold thickness of each body segment are measured by Martin's measuring instrument and Skinfold Caliper. Measured items of this study is based on Lohman's methods and is added new items. (4) DATA ANALYSIS The Volume, Weight, Rate, and Index of each group are calculated by using measuring items. The difference of each group is analyzed by SPSS 7.0 for Win. 3. RESULT (1) THE MORPHOLOGIC CHARACTERISTIC of TAEUMIN First of all, the Taeumin has a emormous morphology. His trunk is huge but head-neck and limbs is small. The volume and weight of head-neck is smaller than other body segments but the volume and weight of upper-abdomen is bigger than ones. (2) THE MORPHOLOGIC CHARACTERISTIC of SOEUMIN The Soeumin has a small morphology. His head-neck rate is bigger than Taeumin's but his trunk rate is smaller than Taeumin's. And his lower limbs rate is bigger than other constitution but it's not a significant difference. His neck is thinest and longgest than others. His chest is thin and narrow. His lower-abdomen rate is bigger than other constitution but it's difference is not significant. (3) THE MORPHOLOGIC CHARACTERISTIC of SOYANGIN Soyangin has a middle size at head-neck and chest part. But the rate of upper limb is higer than other constitution. And the rate of lower-abdomen part is lower than other constitution. but that's not significant.

  • PDF

Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss (유출수 및 유실토량 측정장치에 관한 수리시험)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.1
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF

Effect of Austempering Treatment on Damping Capacity and Mechanical Properties in Gray Cast Iron (회주철의 진동감쇠능과 기계적 성질에 미치는 오스템퍼링처리의 영향)

  • Han, D.W.;Kim, J.C.;Son, Y.C.;Baik, S.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.2
    • /
    • pp.108-116
    • /
    • 1999
  • Gray cast iron with a high damping capacity has been used for controlling the vibration and noise in various mechanical structures. Nevertheless, its usage has been often restricted due to its poor tensile strength. Therefore, it is necessary to improve tensile strength at the expense of a loss in damping capacity. This study is aimed at finding the best combination of tensile strength and damping capacity by varying austempering time and temperature range from $320^{\circ}C$ to $380^{\circ}C$ after austenization at $900^{\circ}C$ for 1hr. The effect of austempering condition on hardness and the volume fraction of retained austenite is investigated as well. The results obtained are summarized as follows : (1) With an increase in austempering temperature, both tensile strength and hardness decrease while damping capacity improves. (2) Austempering at $350^{\circ}C$, resulting in a mixture of upper and lower bainite with partially retained austenite, exhibits the optimum combination of tensile strength and damping capacity.

  • PDF

An Analysis of Elementary Students' Selection of Representable Value and Confident Method That Appear in Measuring Activities (측정과 관련된 실험 활동에서 보이는 초등학생의 대푯값 선정 및 신뢰 방법 분석)

  • Yang, Il-Ho;Lim, Sung-Man;Lim, Jae-Keun;Song, Jin-Lyoung
    • Journal of Korean Elementary Science Education
    • /
    • v.28 no.3
    • /
    • pp.263-276
    • /
    • 2009
  • The purpose of this study was to analyze the elementary students' selection of representable value and confident method that appear in measuring activities by using a microgenetic method. The participants were seven elementary students in the fourth grade. They performed the same measuring activities six times for the study period. Data were collected by interview and observation with their activity recording papers and video tape transcription. Their activities were recorded and documented for the analysis. Results were as follows. First, in the time measuring activity, elementary students developed desirably as their measuring experience increased, for example they selected a representable value in use of a repeated measurement and used a various method in the domain of a time measurement and they showed an increase of a quantitative observation in the volume domain except in the length domain. Second, in a confident method of a representable value, though they must rely upon a repeated measurement, they only measure repeatedly in the time domain. Also in the time domain, it doesn't get accomplished a exact confidence of a representable value at a shortage of skill about a measurement. Accordingly this study will be implications for teachers to teach a handling abilities of measuring instruments to elementary students and to be promote understanding a nature of measurement.

  • PDF

Assessment of Breast Volume Change after Transverse Rectus Abdominis Myocutaneous Flap

  • Park, Sang Uk;Shim, Jeong Su
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.631-635
    • /
    • 2012
  • Background The evaluation of a breast after breast reconstruction depends on a surgeon's subjective criteria. We used computed tomography (CT) scans to obtain an objective evaluation of the postoperative results by measuring the breast volume of patients who had undergone breast reconstruction using pedicled transverse rectus abdominis myocutaneous (TRAM) flaps. This research will help in the objective postoperative evaluation of reconstructed breasts, and also in the preoperative flap size designs. Methods A total of 27 patients underwent breast reconstruction using pedicled TRAM flaps after mastectomy from September 2007 to July 2010. Of these, 10 patients who were followed up and underwent CT scans 2 or more times during the follow-up period were included in this study. We evaluated the change in breast volume over time using CT scans, and the interval breast volume change between CT scans. Results All of the 10 patients' reconstructed breasts showed a volume decrease over time. The breast volume changes in the intervals between CT scans were as follows: 5.65% decrease between the first CT and second CT scan, 2.3% decrease between the second CT and third CT scan, (statistically significant) and 1.89% decrease between the third CT and forth CT scan. (not statistically significant). Conclusions This research shows the possibility of objectively evaluating the postoperative breast volume changes. The findings will be helpful in designing the size of TRAM flaps to use on defects after mastectomy. Based on these results, we should also closely observe the reconstructed breast volume for at least 2 years.

Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study

  • Lee, Woo Yeon;Kim, Min Jung;Lew, Dae Hyun;Song, Seung Yong;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.430-437
    • /
    • 2016
  • Background Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to confirm the validity of 3D-scanning technology for evaluating breast volume. Methods We reviewed the charts of 25 patients who underwent breast reconstruction surgery immediately after total mastectomy. Breast volumes using the Axis Three 3D scanner, water-displacement technique, and magnetic resonance imaging (MRI) were obtained bilaterally in the preoperative period. During the operation, the tissue removed during total mastectomy was weighed and the specimen volume was calculated from the weight. Then, we compared the volume obtained from 3D scanning with those obtained using the water-displacement technique, MRI, and the calculated volume of the tissue removed. Results The intraclass correlation coefficient (ICC) of breast volumes obtained from 3D scanning, as compared to the volumes obtained using the water-displacement technique and specimen weight, demonstrated excellent reliability. The ICC of breast volumes obtained using 3D scanning, as compared to those obtained by MRI, demonstrated substantial reliability. Passing-Bablok regression showed agreement between 3D scanning and the water-displacement technique, and showed a linear association of 3D scanning with MRI and specimen volume, respectively. Conclusions When compared with the classical water-displacement technique and MRI-based volumetry, 3D scanning showed significant reliability and a linear association with the other two methods.

Maxillary first molar wear: a longitudinal study of children

  • Kim, Won-Hee;Nam, Shin-Eun;Park, Young-Seok;Lee, Seung-Pyo
    • Anatomy and Cell Biology
    • /
    • v.51 no.4
    • /
    • pp.251-259
    • /
    • 2018
  • The aim of this study is to examine the correlation between tooth wear and age by quantitatively measuring maxillary first molar wear in children. A total of 150 maxillary dental models were analyzed in 30 subjects (male, 11; female, 19) with an age range of 6-14 years. Maxillary first molar wear were assessed based on area, volume and the shortest distance from the buccal occlusal plane to the central pit point (BCPH). The area and volume of the tooth cusps were measured at four different offset-plane heights (0.2, 0.4, 0.6, and 0.8 mm). Relationship between age and the amount of wear or BCPH were statistically analyzed. Correlation and regression analyses were also performed, and age estimation was obtained with linear regression analysis. Repeated measures analysis of variance (ANOVA) revealed significant differences between age and the amount of wear based on area, volume, and offset-plane height. Except age of 8 and 10, 12 and 14's 0.2-mm offset-plane-measured volume, all area and volume measurement of all ages and offset-plane height showed a significant amount of increase. Wear speeds were calculated using the BCPH. Among age and measurement variables, the correlation coefficient was strongest when the volume was measured from the 0.4-mm offset-plane. As age increases, the amount of wear, as quantified by area and volume measurements, also increases. According to this study, a regression equation that can be used for age estimation is follows: Age $(y)=0.16{\times}0.4V+0.85$ ($R^2=0.490$) using volume.

Actual Production Conditions of Fermented Soybean Products on the Level of Farmhouses (장류가공사업 농가의 장류 생산실태에 관한 연구)

  • 김은미;정금주;이승교;원향례
    • The Korean Journal of Community Living Science
    • /
    • v.14 no.3
    • /
    • pp.89-98
    • /
    • 2003
  • To assess the actual status of businesses selling fermented soybean products, this study surveyed 130 Farmhouse style small size soybean sauce processing sites supported by the Rural Development Administration nationwide. The sex composition of the businesses representatives of 2% male and 98% female showed that a farmhouse soybean processing business is generally operated by rural women as a non-filming business. The percentage of co-worked sites was 71.2 and that of sites with permits was 39.2. The main products were meju, doenjang, and kanjang. Total production volume was found to be 523 tons, 256 tons, and 135 k$\ell$s, respectively. The number of years of experience of the manufacturers of the kanjang and doenjang was found to be 25.7 on average which shows that long-experienced, skilled manufacturers are participating in this project. The traditional measuring unit differed greatly depending on the region. This difference in the measuring unit of soybeans resulted in a large difference in the volume of doenjang and kanjang produced Per Province. For one kg of raw soybeans, the weight of Doenjang produced also varied from 2.14 kg in the Gyeongbuk area to 1.62 kg in Jeju. In the aspect of salt use, 1.75 $\ell$ (translated by volumetric unit 0.704 due) of salt pet kg of meju, in Jeju, was the highest in Korea. Government supervision would be beneficial in the areas of raw material products, standardization of measuring units and production methods, organization and operation of a conference for the different groups of producers, and in construction of a nationwide database.

  • PDF