• Title/Summary/Keyword: measuring vessel

Search Result 157, Processing Time 0.022 seconds

The Simulation for the Organization of Fishing Vessel Control System in Fishing Ground (어장에 있어서의 어선관제시스템 구축을 위한 모의실험)

  • 배문기;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.175-185
    • /
    • 2000
  • This paper described on a basic study to organize fishing vessel control system in order to control efficiently fishing vessel in Korean offshore. It was digitalized ARPA image on the fishing processing of a fleet of purse seiner in conducting fishing operation at Cheju offshore in Korea as a digital camera and then simulated by used VTMS. Futhermore, it was investigated on the application of FVTMS which can control efficiently fishing vessels in fishing ground. The results obtained were as follows ; (1) It was taken 16 minutes and 35 minutes to casting and hauling net in fishing processing respectively. The length of rope pulled by scout boat was 200m, tactical diameter in casting net was 340.8m, turning speed was 6kts as well. (2) The processing of casting and hauling net was moved to SW, NE as results of simulation when the current direction and speed set into NE, 2kts and SW, 2kts respectively. Such as these results suggest that can predict to control the fishing vessel previously with information of fishing ground, fishery and ship's maneuvering, etc. (3) The control range of VTMS radar used in simulation was about 16 miles. Although converting from a radar of the control vessel to another one, it was continuously acquired for the vector and the target data. The optimum control position could be determined by measuring and analyzing to distance and direction between the control vessel and the fleet of fishing vessel. (4) The FVTMS(fishing vessel traffic management services) model was suggested that fishing vessels received fishing conditions and safety navigation information can operate safely and efficiently.

  • PDF

Adhesion of Ice Slurry in an Aqueous Solution Cooling with Stirring (수용액의 교반/냉각을 동반한 슬러리 얼음의 빙부착)

  • Kang, Chae-Dong;Son, Kwon;Baek, Jong-Hyun;Hong, Hee-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1071-1077
    • /
    • 2002
  • Ice adhesion on cooling wall is very important in continuous ice formation. The purpose of the present study is to investigate the possibilities of a three-component aqueous solution as a thermal storage material for the continuous ice formation. By freezing under stirring the solution of 300 mL in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, an ice slurry was formed experimentally with measuring the temperature and stirring load variation. From the experiment, the ice adhesion was suppressed when the supercooling degree decreased and the concentration of aqueous solution increased.

Adhesion of Ice Slurry in a Multi-component Aqueous Solution with Stirring and Cooling (다성분계 수용액의 교반/냉각에 의한 빙부착)

  • 강채동;강용태;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1063-1070
    • /
    • 2002
  • To resist ice adhesion on cooling wall is concerned to continuous ice formation in thermal storage system. In this study, ice slurries were formed with two ecological aqueous solution, one is ethanol+silanol and the other is propylene glycol+silanol. By freezing under stirring the solution of $300m\ell$ in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, the shape of ice slurry and the strength of ice adhesion on wall was observed with measuring the temperature and stirring load variation. As the concentration is smaller and the supercooling degree is larger, the ice adhesion is easy to occur. When the stirring load is larger than$ 2.1\times10^{-5}W$, the ice adhesion occurred.

Precise Measurement Method of Radial Artery Pulse Waveform using Robotic Applanation Tonometry Sensor (로보틱 토노메트리 센서를 이용한 요골 동맥 파형 정밀 측정 방법)

  • Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2017
  • In this paper, a novel measurement method of radial artery pulse waveform using robotic applanation tonometry (RAT) was present to reduce the errors by the pressing direction of the vessel. The RAT consisted of an array of pressure sensors and 2-axis tilt sensor, which was attached to the universal joint with a linear spring and five-DOF robotic manipulator with a one-axis force sensor. Using the RAT mechanism, the pulse sensor could be manipulated to perpendicularly pressurize the radial artery. A pilot experimental result showed that the proposed mechanism could find the optimal pressurization angles of the pulse sensor within ${\pm}3^{\circ}$standard deviations. Coefficient values of variation of maximum pulse peaks extracted from the pulse waveforms were 4.692, 6.994, and 11.039 % for three channels with the highest magnitudes. It is expected that the proposed method can be helpful to develop more precise tonometry system measuring the pulse waveform on the radial artery.

Study on the Subacute Toxicity of Complex of Pine Needle Oil and Korean Medicinal Herbs against Rats

  • Park, Kap Joo;Ahn, Ki Heung;Lee, Hyung Hoan
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.4
    • /
    • pp.513-518
    • /
    • 2004
  • Pine needle oil and Korean medicinal herbs (KMH) are known as effective therapeutic agents on various blood vessel disease. We have already reported the ameliorative effect of complex of pine needle oil and Korean medicinal herbs against hyperlipidemia. But safety and non - toxicity of pine needle oil and Korean medicinal herbs to normal animal cells have not been studied clearly. In this study, we investigated whether pine needle oil and Korean medicinal herbs show side effects on rat or not. These materials were administered to rats, and subacute toxicity was examined by measuring the hematological values, CBC differentiation, biochemical levels of blood (TP, total protein; albumin; ALP, alkaline phosphotase; AST, aspatate aminotrans- ferase; ALT, alanine aminotransferase; T-Chol., total cholesterol; T-Bil., total bilirubin) and urine analysis, suggesting that the sample have no side effects and cytotoxicity. These results indicate that the complex of pine needle oil and Korean medicinal herbs may effective non- toxic, safety therapeutic agents on hepatocytes and hyperlipidemia.

Autoignition of Urethane Foam to be Used as the Insulator of the Household Refrigerator

  • Choi, Jae Wook;Mok, Yun Soo
    • International Journal of Safety
    • /
    • v.1 no.1
    • /
    • pp.47-51
    • /
    • 2002
  • This study was performed by measuring the minimum ignition temperature of polyurethane form recovered from the recycling process of the end-of-life home appliances. The critical ignition temperature of polyurethane form was lower as the size of the sample vessel was increased, and that of polyurethane form using cyclopentane as the forming agent was relatively lower than the polyurethane form using CFC and the combustion of cyclopentane-polyurethane form occurred fiercely. It is considered that the recycling process of end-of-life home appliances using cyclopentane-polyurethane form as the insulator would require a special fire and dust explosion prevention measures since there exists a high potential hazard of fire and dust explosion during crushing and storage processes.

A Development of Portable Early Detector of Intravenous Infiltration based on Optical Sensor (광센서 기반 휴대형 침윤 조기 감지기 개발)

  • Lee, Sungjin;Shin, Bum Joo;Jeong, IhnSook
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.705-711
    • /
    • 2018
  • Intravenous(IV) therapy being in use for many patients may cause serious side effects such as infiltration, extravasation. To minimize such side effects, it is important to detect symptoms appearing when fluid escapes from blood vessel to tissue as soon as possible. This paper describes a device which has been developed to detect IV infiltration early using optical sensor. The device detects IV infiltration as measuring intensity of lights reflected from that lights after emitting lights in IV therapy site. The lights are consisted of 4 different waves which provide different reflection ratio depending the fluid used in IV therapy. The experimental results show that the device can be used to detect IV infiltration early.

Measurement of Leukocyte Motions in a Microvessel Using Spatiotemporal Image Analysis

  • Kim, Jin-Woo
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.315-319
    • /
    • 2008
  • This paper describes a method for recognizing and measuring the motion of each individual leukocyte in microvessel from a sequence of images. A spatiotemporal image is generated whose spatial axes are parallel and vertical to vessel region contours. In order to enhance and extract only leukocyte traces with a turned velocity range even under noisy background, we use a combination of a filtering process using Gabor filters with sharp orientation selectivity and a subsequent 3D spatiotemporal grouping process. The proposed method is shown to be effective by experiments using image sequences of two kinds of microcirculation, rat mesentery microvessels and human retinal capillaries.

A Study on the Response of Fishing Vessels in Seas according to various Tonnage (어선의 크기 변화에 따른 실선 응답특성에 관한 고찰)

  • 강일권;윤점동;조효제
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1996.04a
    • /
    • pp.5-20
    • /
    • 1996
  • It is important to investigate the hull response of a fishing vessel in waves to ensure the safety of it and to keep excellent sea-keeping qualities. For this purpose we measured the response of fishing vessels in waves using real sea experimental measuring system, We analyze the experimental data by statistical method and spectral analysis to get the characteristics of the response of vessels which have different tonnage. In this real sea experiment we use three stern trawlers which are the training ship in university. We know that the distribution of experimental response have Gauss distribution and Rayleigh distribution and smaller vessels have larger response.

  • PDF

Increments of Elastic Lad Carrying Capacity of Compound Cylinder by Using Modified-Shrink-Fit Method (修正죔맞춤 방법 을 이용한 複合圓통 의 彈性負荷能力 의 증대)

  • 정성종;홍창선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.3
    • /
    • pp.335-343
    • /
    • 1983
  • Modified-Shrink-Fit(MSF) method of compound cylinder is studied to increase elastic load carrying capacity (ELCC) of pressure vessel. The autofrettage and the shrink-fit processes are used to study the MSF process. Theoretical analyses based on the Tresca yield criterion, Hencky's total strain theory and elastic linearly strain-hardening material are carried out to derive closed form solutions. Experimental results are compared with theoretical results with various diameter ratios between outer (SM45C) and inner (SM20C) bloc cylinder. For various diameter ratios, increments of ELCC have errors in strains vs. internal loading pressures between experimental and theoretical results. But experimental results show good agreements with theoretical results in reyield pressurizing state. The increments of ELCC of compound cylinder manufactured by the MSF process is proved by measuring the residual stresses.