• Title/Summary/Keyword: measuring units

Search Result 269, Processing Time 0.03 seconds

A Study on the As-Built Leakage Diagnosis of Main Steam Drain Valves for Nuclear Power Plants by Multi-measuring Technique (다중계측기법을 이용한 원전 주증기배수밸브의 현상태 누설진단에 관한 연구)

  • Kim, Sung-Young;Kim, Young-Bum;Kim, Do-Hyeong;Lee, Sang-Gok
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2606-2611
    • /
    • 2008
  • The high energy fluid leakage from the high temperature and high differential pressure drop system of NPPs (Nuclear Power Plants) decreases efficiency and consequently leads to considerable economic loss due to less power production. Also, the leakage possibly damages critical parts of components such as valve and trim with the effect of cavitation, flashing, and erosion, etc. and deteriorates its performance. Thus, in this study, we diagnosed the as-is leakage for four (4) main steam drain valves and two (2) steam traps of Yonggwang 1,2 units during normal operation by using multi-measuring technique and observed the occurrence of fine leakage. In the course of measuring fluid leakage, the sign of fine leakage is estimated to be the leakage from orifice. By converting the leakage to energy loss, it is equivalent to the amount of several hundred thousand won per each unit, which supports the basis for the justification of fine leakage.

  • PDF

Analysis of Radiation Exposure Dose according to Location Change during Radiation Irradiation

  • Chang-Ho Cho;Jeong-Lae Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.2
    • /
    • pp.368-374
    • /
    • 2024
  • During an X-ray examination, the beam of radiation is dispersed in many directions. We believe that managing radiation dose is about providing transparency to users and patients in the accurate investigation and analysis of radiation dose. The purpose of measuring the radiation dose as a function of location is to ensure that medical personnel using the equipment or participating in the operating room are minimally harmed by the different radiation doses depending on their location. Four mobile diagnostic X-ray units were used to analyze the radiation dose depending on the spatial location. The image intensifier and the flat panel detector type that receives the image analyzed the dose by angle to measure the distribution of the exposure dose by location. The radiation equipment used was composed of four units, and measuring devices were installed according to the location. The X-ray (C-arm) was measured by varying the position from 0 to 360 degrees, and the highest dose was measured at the center position based on the abdominal position, and the highest dose was measured at the 90° position for the head position when using the image intensifier equipment. The operator or medical staff can see that the radiation dose varies depending on the position of the diagnostic radiation generator. In the image intensifier and flat panel detector type that accepts images, the dose by angle was analyzed for the distribution of exposed dose by position, and the measurement method should be changed according to the provision of dose information that is different from the dose output from the equipment according to the position.

Laboratory Evaluation of the Accuracy, Precision, and Inter-instrumental Variance of a Portable Photoionization Detector (휴대용 광이온화 검출기의 정확도, 정밀도 및 기기간 차이에 대한 실험실 평가)

  • Choi, Dongmin;Choi, Youngeun;Yoon, Chungsik;Rhie, Kwangwon;Lee, Yunkeun;Lee, Ikmo;Park, Jeongim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.200-208
    • /
    • 2012
  • Objectives: This study investigated the performance of three separate units of a portable photoionization detector (PID, ppb-RAE 3000) for measuring volatile organic compounds (VOCs) in a laboratory. Methods: A laboratory evaluation of the accuracy, precision, and inter-instrumental variance of three separate units of a portable PID (ppb-RAE 3000) was performed. The evaluation was based on the preparation of a test air sample of known toluene or ethylacetate concentration in a Tedlar$^{(R)}$ bag. The test air sample was monitored and data were logged consecutively by the three PIDs. A certified gas of 50 ppm toluene was also monitored during the test to ensure the reliability of the generated test air sample. Four different concentrations ranging from 0.1 to 2 TLV were used and a series of five measurements for each concentration level was performed. The accuracy was evaluated using National Institute for Occupational Safety and Health (NIOSH) criteria. Results: The results from the oldest ppb-RAE3000 unit among the three test units generally fell outside the NIOSH recommended accuracy criteria of ${\pm}25%$, whereas the other two units produced results which were acceptable at, or greater than, 25 ppm of toluene, or 0.5 TLV. These units also met the NIOSH criteria for some ethylacetate measurements but the results were not consistent. Conclusions: Considering the inconsistent performance of these ppb-RAE 3000 units, this device may not be appropriate for use as an alternative to the standard measurement methods. However, it can serve good survey instruments to identify exposure sources or concentration profiles. For all applications, the ppb-RAE 3000 should be used with frequent calibration checks, additional validation using a reference material, and careful maintenance.

Modified Transmission Line Protection Scheme in the Presence of SCC

  • Naeini, Ehsan Mostaghimi;Vaseghi, Behrouz;Mahdavian, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.533-540
    • /
    • 2017
  • Distance relay identifies the type and location of fault by measuring the transmission line impedance. However any other factors that cause miss calculating the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of the important factors which directly changes the measured impedance by the relay is series capacitive compensation (SCC). Another factor that changes the calculated impedance by distance relay is fault resistance. This paper provides a method based on the combination of distance and differential protection. At first, faulty transmission line is detected according to the current data of buses. After that the fault location is calculated using the proposed algorithm on the transmission line. This algorithm is based on active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. This method measures the voltage across SCC by phasor measurement units (PMUs) and transmits them to the relay location via communication channels. The transmitted signals are utilized to modify the voltage signal which is measured by the relay. Different operating modes of SCC and as well as different faults such as phase-to-phase and phase-to-ground faults are examined by simulations.

Retroperitoneal Hematoma as a Serious Complication of Endovascular Aneurysmal Coiling

  • Murai, Yasuo;Adachi, Koji;Yoshida, Yoichi;Takei, Mao;Teramoto, Akira
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.1
    • /
    • pp.88-90
    • /
    • 2010
  • Retroperitoneal hematoma (RH) due to radiologic intervention for an intracranial lesion is relatively rare, difficult to diagnose, and can be lifethreatening. We report a case of RH that developed in a patient on anticoagulant therapy following endovascular coiling of a ruptured anterior communicating artery (AcoA) aneurysm. An 82-year-old man presented with a 12-day history of headache. Computed tomography (CT) on admission demonstrated slight subarachnoid hemorrhage, and left carotid angiography revealed an AcoA aneurysm. The next day, the aneurysm was occluded with coils via the femoral approach under general anesthesia. The patient received a bolus of 5,000 units of heparin immediately following the procedure, and an infusion rate of 10,000 units/day was initiated. The patient gradually became hypotensive 25 hours after coiling. Abdominal CT showed a huge, high-density soft-tissue mass filling the right side of the retroperitoneum space. The patient eventually died of multiple organ failure five days after coiling. RH after interventional radiology for neurological disease is relatively rare and can be difficult to diagnose if consciousness is disturbed. This case demonstrates the importance of performing routine physical examinations, sequentially measuring the hematocrit and closely monitoring systemic blood pressures following interventional radiologic procedures in patients with abnormal mental status.

Measuring Nuclear Power Plant Negative Externalities through the Life Satisfaction Approach: The Case of Ulsan City

  • LEE, KYE WOO;YOO, SE JONG
    • KDI Journal of Economic Policy
    • /
    • v.40 no.1
    • /
    • pp.67-83
    • /
    • 2018
  • We have hypothesized that nuclear risk is significantly inversely related to the distance from residences to nuclear power plants and that the level of life satisfaction of residents therefore increases with the distance. We empirically explore the relationship between Ulsan citizens' life satisfaction levels and the distance between their residences and the Kori and Wolsong nuclear power plants (NPP) based on the life satisfaction approach (LSA). The dataset we used covers only Ulsan citizens from the biennial Ulsan Statistics on Citizen's Living Condition and Consciousness of 2014 and 2016. Controlling for micro-variables such as education, work satisfaction, gender, marital status, and expenditures, we found a statistically significant relationship between life satisfaction and the distance between the residences and the nuclear power plants. Nuclear negative externalities including (i) health and environmental impact, (ii) radioactive waste disposal, and (iii) the effect of severe accidents can be quantified in terms of LS units and monetary units. We were able to calculate the monetary value of NPP externalities at $277 per kilometer of distance for Kori and $280 per kilometer of distance for Wolsong at constant 2015 prices. These estimates are quite different from the traditional estimates made with the contingent valuation method, whereas they are similar to the findings of LSA studies abroad. Hence, the need to adopt the LSA in South Korea and policy implications are demonstrated.

3,6-Carbazole Incorporated into Polymer Effects on Solar Cells

  • Lee, Gang-Young;Cha, Hyojung;Park, Chan Eon;Park, Taiho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.481.2-481.2
    • /
    • 2014
  • Bulk hetero junction (BHJ) polymer solar cell (PSCs) is one of the most promising fields as alternative energy source. Especially, the development of new p-type conjugated polymer is one of the main issues to get core technology. In this study, we investigated the chemical doping effects of incorporating 3,6-carbazole units into conjugated polymers based on 2,7-carbazole. We assessed the structural effects of this chemical doping by measuring the photovoltaic device performance of the copolymers with and without annealing. Note that the use of nanostructures in the bulk heterojunction layer could be a major obstacle to commercialization because nano-morphologies are frequently unstable at high temperatures. Therefore, the development of thermally stable polymer:fullerene blends with optimized PCEs is an important goal in this area of research. We studied the morphologies of the copolymers incorporating 3,6-carbazole units resulting from thermal annealing to investigate the effects of the difference between the T g values of the 2,7-carbazole unit and the 3,6-carbazole unit.

  • PDF

Impact Analysis of Wind Power on Power System Reliability with Electric Vehicles (풍력발전과 전기자동차가 전력계통의 신뢰도에 미치는 영향 평가)

  • Kim, Dam;Park, Hyeongon;Kwon, Hungyu;Park, Jong-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.11
    • /
    • pp.1535-1542
    • /
    • 2015
  • An increasing number of electric vehicles (EVs) in power system affects its reliability in various aspects. Especially under high EV penetration level, new generating units are required to satisfy system's adequacy criterion. Wind power generation is expected to take the major portion of the new units due to environmental and economic issues. In this paper, the system reliability is analyzed using Loss of Load Expectation (LOLE) and Expected Energy Not Served (EENS) under each and both cases of increasing wind power generation and EVs. A probabilistic multi-state modeling method of wind turbine generator under various power output for adequate reliability evaluation is presented as well. EVs are modeled as loads under charging algorithm with Time-Of-Use (TOU) rates in order to incorporate EVs into hour-to-hour yearly load curve. With the expected load curve, the impact of EVs on the system adequacy is analyzed. Simulations show the reliability evaluation of increasing wind power capacity and number of EVs. With this method, system operator becomes capable of measuring appropriate wind power capacity to meet system reliability standard.

Factors Related to Workload of Intensive Care Unit Nurses: Systematic Review and Meta-Analysis (중환자실 간호사의 업무부담 관련 요인: 체계적 문헌고찰 및 메타분석)

  • Jeong, Ah In;Shin, Sujin;Hong, Eunmin
    • Journal of Korean Clinical Nursing Research
    • /
    • v.29 no.3
    • /
    • pp.296-311
    • /
    • 2023
  • Purpose: This study aimed to identify factors related to the workload of intensive care unit nurses through a systematic literature review and meta-analysis to provide basic data to explore the direction of development of nursing staffing standards. Methods: This study involved quantitative studies about nurses working in intensive care units related to nursing workload published in English or Korean since 2000. Search terms included 'intensive care unit', 'nursing workload', and their variations. Databases such as RISS, DBpia, MEDLINE(PubMed), CINAHL, PsycINFO, and Web of Science were utilized. Quality assessment was conducted using the Joanna Briggs Institute's Critical Appraisal Checklist for Analytical Cross-Sectional Studies. JAMOVI software facilitated the analysis of effect sizes, employing a meta-analysis approach for 7 studies with correlational or regression data. Results: From 16 studies on the workload of intensive care unit nurses, a total of 20 patient and nurse-related factors were identified. Patient-related factors included severity of illness, length of stay, and age. Meta-analysis was conducted for three patient-related factors: age, severity of illness measured by SAPS 3, and length of stay. Only severity of illness measured by SAPS 3 was significantly associated with nurse workload (Zr=0.16, p<.001, 95% CI=0.09-0.24). Conclusion: In previous studies, the characteristics of intensive care units and patients varied across studies, and a variety of scales for measuring workload and severity of illness were also used. Sustained research reflecting domestic intensive care unit work environments and assessing the workload of intensive care unit nurses should be imperative.

An Intra Prediction Hardware Architecture Design for Computational Complexity Reduction of HEVC Decoder (HEVC 복호기의 연산 복잡도 감소를 위한 화면내 예측 하드웨어 구조 설계)

  • Jung, Hongkyun;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1203-1212
    • /
    • 2013
  • In this paper, an intra prediction hardware architecture is proposed to reduce computational complexity of intra prediction in HEVC decoder. The architecture uses shared operation units and common operation units and adopts a fast smoothing decision algorithm and a fast algorithm to generate coefficients of a filter. The shared operation unit shares adders processing common equations to remove the computational redundancy. The unit computes an average value in DC mode for reducing the number of execution cycles in DC mode. In order to reduce operation units, the common operation unit uses one operation unit generating predicted pixels and filtered pixels in all prediction modes. In order to reduce processing time and operators, the decision algorithm uses only bit-comparators and the fast algorithm uses LUT instead of multiplication operators. The proposed architecture using four shared operation units and eight common operation units which can reduce execution cycles of intra prediction. The architecture is synthesized using TSMC 0.13um CMOS technology. The gate count and the maximum operating frequency are 40.5k and 164MHz, respectively. As the result of measuring the performance of the proposed architecture using the extracted data from HM 7.1, the execution cycle of the architecture is about 93.7% less than the previous design.