• Title/Summary/Keyword: measurements

Search Result 21,603, Processing Time 0.116 seconds

A Study on a Measurement Method for 2D Anthropometry using Digital Camera (디지털 카메라를 이용한 2D 인체계측법 연구)

  • 손희정;김효숙;최창석;손희순;김창우
    • The Research Journal of the Costume Culture
    • /
    • v.11 no.1
    • /
    • pp.11-19
    • /
    • 2003
  • This study suggests the new 2D anthropometric method using digital camera. It is used MK2001 program that can convert 2D measurements to 3D measurements. To improve that it is measured 100 college students with direct and indirect anthropometric method. The measurements were processed by the SPSS ver10 Statistical Package. The average, standard deviation, and t-test were calculated for each category. Most measurements by 2D measurements are higher than direct measurements but degree. The difference between direct and indirect measurements is less than 2cm. In the results of t-test, height measurements including other 16 measurements which is easy to measure have no meaningful difference within 1cm. The depth measurements are most high difference. The result of each measurement proves that MK2001 program (2D anthropometry method using digital camera) is available for measuring the human body.

  • PDF

A Study on the Body Measurements of Korean Female Adults Resident in China -With the Focus on their 20's, 40's, and 60's- (중국 조선족 성인 여성 신체 계측치 연구 -20대, 40대, 60대를 중심으로-)

  • Im Soon;Seok Hye-Jung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.9_10 s.146
    • /
    • pp.1241-1252
    • /
    • 2005
  • This study tried to compare and analyze the body measurements of female adults in China by various age groups. As for the study method, direct and anthropometric measurements were used on the 357 female subjects living in Yenbien and Harbin, China, consisting of 122 women in their 20's, 114 women in their 40's, and 121 women in their 60's. The results were as follows: 1. The comparison of major body measurements between Korean Chinese and Korean in land indicated that the former were shorter and plumper than the latter. Those groups in their 60's did not show any significant difference in height related measurements and revealed less differences in body measurements comparing to other age groups. 2 The comparison of Chinese anthropometric measurements among age groups of Korean Chinese indicated that, higher the age, shorter the height measurements, the leg length shorter, the upper-half body length longer, and the chest drooping due to the breast descent. 3. The comparison of indirect measurements among age groups of Koreans Chinese indicated that those in their 60's showed many items of big discrepancies in comparison with those in their 20's or 40's, with wide gap in discrepancies, thus resulting in large differences among individuals.

Application of the Measurements Control System to NATM Tunnel Constructed in Urban Area (도심지 NATM 터널에서의 계측관리시스템 적용 연구)

  • 장정범;김용일;김영근;정한중
    • Tunnel and Underground Space
    • /
    • v.5 no.3
    • /
    • pp.193-204
    • /
    • 1995
  • Since the significance of measurements during tunnel construction is not recognized, measurements have not been implemented except for a few very important construction site. As the tunnel construction by NATM increases, the importance of measurements is being emphasized. But, due to the lack of practical experiences and theoretical background in measurements techniques, systematic measurements control system has not yet been established. In this study a measurements control system, successfully used in the urban tunnel construction, is introduced.

  • PDF

POSTERO-ANTERIOR CEPHALOMETRIC STUDY OF CRANIO-FACIAL SKELETON ON KOREAN (한국인정모(韓國人正貌)에 관(關)한 두부(頭部) 방사선학적(放射線學的) 연구(硏究))

  • Kang, Dae Joon
    • The korean journal of orthodontics
    • /
    • v.9 no.1
    • /
    • pp.67-84
    • /
    • 1979
  • The author measured the right and left craniofacial skeleton using posteroanterior cephalography of 124 male and 97 female subjects of ages ranging 2-6 years, 7-13 years and adult group on Korean. Statstical parameters were calculated by computer from the data. The results of the study were as follows. 1. In the male and female group of deciduous dentition, the right side measurements were slightly greater than the left side measurements, and generally male measurements were greater than female measurements. 2. In the both sex group of mixed dentition, the right side measurements were greater than the left side measurements, and in comparision of sex, the female recognized more growth, and development than male, especially on the cranial base, lateral maxilla, lower maxilla and dental region. 3. In the permanent dentition group, regardless of sex, the right side measurements were greater than the left side measurements, and in the sex difference, male was conspicuously greater than female on both sides measurements. 4. In the permanent dentition group, the asymmetry of the face was striking than deciduous dentition and mixed dentition group.

  • PDF

A Robust Target Motion Analysis Algorithm for Discontinuous Frequency Measurements (불연속적인 다중 주파수 측정치에 강인한 표적기동분석 알고리즘)

  • Cheong, Myoung-Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.372-379
    • /
    • 2011
  • Estimating underwater target state variables(position, velocity, course, etc) is necessary to counteract threatening targets. In passive sonar systems, conventional target motion analysis(TMA) techniques using bearing and frequency measurements of an underwater target are widely introduced. However, it is not clear how conventional TMA techniques can be used if some of frequency measurements are unavailable during parts of the scenario, partially unavailable frequency measurements are common in the ocean with complicated acoustic conditions where frequency measurements often come and go. This paper proposes a new TMA algorithm, which is robust to partially unavailable frequency measurements, using the frequency measurements fusion method.

The accuracy of linear measurements of maxillary and mandibular edentulous sites in conebeam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

  • Ganguly, Rumpa;Ramesh, Aruna;Pagni, Sarah
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view ($13cm{\times}16cm$) and small field of view ($5cm{\times}8cm$) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

Comparison of Caliper and Ultrasound Measurement for the Estimation of Body Fat (체지방량 추정을 위한 초음파피지후계와 Caliper의 비교)

  • 정진욱
    • Journal of Nutrition and Health
    • /
    • v.28 no.4
    • /
    • pp.282-290
    • /
    • 1995
  • Subcutaneous fat thickness of 74 young male was measured at six sites(biceps, triceps, subscapula, suprailiac, abdomen, thigh). The present study compared caliper with ultrasound measurements for the estimation of body fat. Caliper measurements subcutaneous at six sites had higher coefficient variation than did the ultrasound measures. Caliper measurements subcutaneous at six sites had higher ratio (caliper/ultrasound) than did the ultrasound measures. Compared to other body sites, the correlations between caliper and ultrasound measurements were high for the subscapula(r=0.7327), abdomen(r=0.7355) and thigh (r=0.7207) sites. the correlations between caliper and ultrasound measurements were high for the suprailiac(r=0.6616) site by lean group. the correlations between caliper and ultrasound measurements were high for the abdomen(r=0.7636) site by normal group. The correlations between caliper and ultrasound measurements were high for the subscapula (r=0.8959) and abdomen(r=0.8237) sites by obese group. Ultrasound measurement of biceps(r=-0.4459), abdomen9r=-0.4469), thigh(r=-0.4348) had the highest correlation with body density. Caliper measurement of triceps(r=-0.4017), subscapula(r=-0.4454), abdomen(r=-0.4293) had the highest correlation with body density. Ultasound measurements subcutaneous fat at lean group, obese group had higher coefficients of correlation with body density than did the caliper measurement. Caliper measurements subcutaneous fat at normal group had higher coefficients of correlation with body density than did the ultrasound measures. Ultrasound showed to be superior to the caliper technique in measuring subcutaneous fat of obese persons.

  • PDF

Spatial and Temporal Assessment of Particulate Matter Using AOD Data from MODIS and Surface Measurements in the Ambient Air of Colombia

  • Luna, Marco Andres Guevara;Luna, Fredy Alejandro Guevara;Espinosa, Juan Felipe Mendez;Ceron, Luis Carlos Belalcazar
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.165-177
    • /
    • 2018
  • Particulate matter (PM) measurements are important in air quality, public health, epidemiological studies and decision making for short and long-term policies implementation. However, only few cities in the word have advance air quality-monitoring networks able to provide reliable information of PM leaves in the ambient air, trends and extent of the pollution. In Colombia, only major cities measure PM concentrations. Available measurements from Bogota, Medellin and Bucaramanga show that PM concentration are well above World Health Organization guidelines, but up to now levels and trends of PM in other cities and regions of the country are not well known. Satellite measurements serve as an alternative approach to study air quality in regions were surface measurements are not available. The aim of this study is to perform a spatial and temporal assessment of PM in the ambient air of Colombia. We used Aerosol optical depth (AOD) retrieved by the Moderate Resolution Imaging Spectroradiometer (MODIS) satellite of NASA and surface measurements from the air quality networks of Bogota, Medellin and Bucaramanga. In a first step, we estimated the correlation between MODIS-AOD and monthly average surface measurements (2000 to 2015) from these three cities, obtaining correlation coefficient R values over 0.4 for the cities under study. After, we used AOD and $PM_{10}$ measurements to study the temporal evolution of PM in different cities and regions. Finally, we used AOD measurements to identify cities and regions with the highest AOD levels in Colombia. All the methods presented in this paper may serve as an example for other countries or regions to identify and prioritize locations that require the implementation of more accurate air quality measurements.

Consideration of Human Factor of Wheelchair and Crutch for the Posteriority Handicapped (후천성 장애인을 위한 휠체어와 목발의 인간공학적 고찰)

  • 구본언;박근상
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.57
    • /
    • pp.77-85
    • /
    • 2000
  • The purpose of this study is to analyze problems of KS measurement of the wheelchair and a pair of crutches and to propose proper measurements of the wheelchair and a pair of crutches for the posteriori handicapped. Research method is as following ; First, it is compared that Anthropometry of Korean and Japanese adults relevance with design measurement of the wheelchair and a pair of crutches. Second, we compared measurements of KS wheelchairs with measurements of the wheelchair manufactured by the T aids company and the D aids company, and then compared and analyzed differences of measurements about each part of the wheelchair. Third, we compared measurements of a pair of crutches of an fixed and an elastic type with anthropometry and analysis. The result, measurements of KS wheelchair and KS a pair of crutches shows unsuitable to Korean adults. It may cause handicapped. We proposed measurements of the aids(the wheelchair and a pair of crutches) proper to the handicapped of Korean adults with improvement of these problems.

  • PDF

Measurements Preprocessing for Bearing and Frequency Target Motion Analysis (BFTMA를 위한 측정데이터 전처리 기법 연구)

  • Kim In-Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.2 s.17
    • /
    • pp.22-31
    • /
    • 2004
  • In this paper, the measurements preprocessing algorithm for the fading of bearing and frequency measurements is proposed, which can improve the performance of BFTMA(Bearing and Frequency Target Motion Analysis). The fading and detection relation between bearing and frequency are rigorously established for measurements preprocessing, and BFTMA can be carried out the estimation of target motion by using measurements preprocessing. Batch estimation with bearing and frequency using the proposed algorithm can be applied to estimate the initial target states despite of the fading of frequency measurement. Simulation results show that BFTMA using the proposed measurements preprocessing has superior estimation performance, compared with batch estimation using only bearing measurements.