• Title/Summary/Keyword: measurement variation

Search Result 1,954, Processing Time 0.027 seconds

Compensation of Resistance Variation due to Temperature in Voltage Measurement System (온도에 따른 저항 변화를 보상한 전압 측정 방법)

  • Min, Sang-Jun;Kim, Jin-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1174-1177
    • /
    • 2012
  • In voltage measurement by using voltage divider with series resistors, error is generated caused by the variation of resistance. In order to reduce these errors, the hardware cost tends to increase in the previous works. In the proposed method, three resistors are used for the voltage divider of which the organization is adjusted by using switches. Three voltages are measured and the ratio of resistance is calculated based on the measured voltages. Since the resistance ratio is calculated by measuring voltages and additional hardware cost is minimal, the voltage can be measured with high accuracy and low cost. Experimental results show that the mean absolute error is 12.1 mV when the input voltage ranges from 5 V to 50 V.

A General Procedure for Estimating the General Parameter Using Auxiliary Information in Presence of Measurement Errors

  • Singh, Housila P.;Karpe, Namrata
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.5
    • /
    • pp.821-840
    • /
    • 2009
  • This article addresses the problem of estimating a family of general population parameter ${\theta}_{({\alpha},{\beta})}$ using auxiliary information in the presence of measurement errors. The general results are then applied to estimate the coefficient of variation $C_Y$ of the study variable Y using the knowledge of the error variance ${\sigma}^2{_U}$ associated with the study variable Y, Based on large sample approximation, the optimal conditions are obtained and the situations are identified under which the proposed class of estimators would be better than conventional estimator. Application of the main result to bivariate normal population is illustrated.

Implementation of the portable brake judder measurement system by use of the Labview (LabView를 이용한 휴대형 브레이크 저더 측정 시스템 구현)

  • Shin, Dong-Uk;Kim, Sun-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.3
    • /
    • pp.569-574
    • /
    • 2008
  • In Because DTV comes to origin of car body shock or brake pedal flutter occurrence in car. This in development of measurement device that can examine this in driver protection dimension or at production early sending of goods visual point purpose of this study have. In this paper, I developed portable Brake Judder measurement system by use of the DTV.

Simplified Wind Turbine Modeling and Calculation of PCC Voltage Variation according to Grid Connection Conditions (간략화된 풍력발전기 모델링과 계통연계 조건에 따른 PCC 전압 변동량 계산)

  • Im, Jl-Hoon;Song, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2402-2409
    • /
    • 2009
  • This paper proposed a simple and helpful analysis model of voltage variation in order to predict the voltage variation at PCC (Point of Common Coupling), when a wind turbine is connected in an isolated grid. The PCC voltage flucuates when the wind turbine outputs active power to an isolated grid. This voltage variation is proportional to the product of the line impedance from the ideal generator to the PCC and the wind turbine output current. And It is different according as where wind turbine is connected. To solve the problem of voltage variation, this paper proposed the reactive power control. To verify the proposed analysis model, this paper utilized PSCAD/EMTDC Simulation and the field measurement data of the voltage variation during the wind power generation.

Measurement of End-to-End Forward/Backward Delay Variation (종단간 순방향/역방향 전송 지연 측정)

  • Hwang Soon-Han;Kim Eun-Gi
    • The KIPS Transactions:PartC
    • /
    • v.12C no.3 s.99
    • /
    • pp.437-442
    • /
    • 2005
  • The measurement of RTT (Round Trip Time) can be used for the analysis of Internet congestion. However, simple measuring of RTT which measures only hun around time of a packet can not infer a packet forward/backward delay variation. In this thesis, we present a new algorithm which can be used for the estimation of forward/backward delay variation of packets. These delay variations are implication of network congestion state. In this algorithm, the reference forward/backward delay can be determined based on the minimum RTT value. The delay variation of each packet can be calculated by comparing reference delay with the packet delay. We verified our proposed algorithm by NS-2 simulation and delay measuring in a real network.

Application of Normality Test and Classification of Process Capability Index (공정능력지수의 유형화 및 정규성 검정의 응용)

  • Choe, Seong-Un
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.551-556
    • /
    • 2011
  • This research presents an implementation strategy of Process Capability Index (PCI) according to the types of process characteristics. The types of process feature are classified as four perspectives of variation range, time period, error position, and process stage. The paper examines short-term or long-term PCI, within or between variation, position of precision or accuracy, and inclusion of measurement or calibration stage. Moreover, the study proposes normality test of unilateral PCI.

  • PDF

On-Machine Measurement of Sculptured Surfaces Based on CAD/CAM/CAI Integration : I. Measurement Error Modeling (CAD/CAM/CAI 통합에 기초한 자유곡면의 On-Machine Measurement : I. 측정오차 모델링)

  • Cho, Myeong-Woo;Lee, Se-Hee;Seo, Tae-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.172-181
    • /
    • 1999
  • The objective of this research is to develop a measurement error model for sculptured surfaces in On-Machine Measurement (OMM) process based on a closed-loop configuration. The geometric error model of each axis of a vertical CNC Machining center is derived using a 4${\times}$4 homogeneous transformation matrix. The ideal locations of a touch-type probe for the scupltured surface measurement are calculated from the parametric surface representation and X-, Y- directional geometric errors of the machine. Also, the actual coordinates of the probe are calculated by considering the pre-travel variation of a probe and Z-directional geometric errors. Then, the step-by-step measurement error analysis method is suggested based on a closed-loop configuration of the machining center including workpiece and probe errors. The simulation study shows the simplicity and effectiveness of the proposed error modeling strategy.

  • PDF

Analysis of Comparison Test and Measurement Error Factor for I - V Performance of Photovoltaic Module (PV모듈 발전성능 비교시험과 계측편차 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.70-75
    • /
    • 2009
  • In this experiment, we did sampling 6 kinds of photovoltaic modules and analyzed the discrepancy of measurement results between l laboratory and 4 PV makers to have performance repeatability at Standard Test Condition(STC) condition. From the KIER's results, Korea's standard test laboratory, other laboratory showed -10% measurement variation. The causes came from correction of reference cell, test condition and the state of skill. Form the comparison test, we analyzed the problems. But three PV maker reduced measurement variation, other one PV maker and one test laboratory didn't improve the problems of correction of reference cell, test condition and the state of skill. Also, High Efficiency Module had a big discrepancy of -10.0$\sim$-6.2% among 3 laboratories which have a less than 10msec light pulse duration time. This made low spectrum response speed so the Fill Factor decreased maximum output power under 10msec light pulse duration time

Formulation of the Sucrose-Free Simulant Human Tissue for SAR Measurement at CDMA Mobile Band

  • Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.2
    • /
    • pp.53-58
    • /
    • 2007
  • A general method to formulate the tissue-equivalent liquids for SAR measurement is proposed to make sucrose-free brain tissue applicable at 835 MHz as an example We suggest the tissue composition can be determined by measuring the dielectric constants and conductivities with the DI water and salt addition variation to the pre-manufactured auxiliary liquid of DGBE and TritonX-100 The manufactured liquid satisfies the specified electrical parameters of international standard at 835 MHz.

Design for Enhanced Precision in 300 mm Wafer Full-Field TTV Measurement (300 mm 웨이퍼의 전영역 TTV 측정 정밀도 향상을 위한 모듈 설계)

  • An-Mok Jeong;Hak-Jun Lee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.3
    • /
    • pp.88-93
    • /
    • 2023
  • As the demand for High Bandwidth Memory (HBM) increases and the handling capability of larger wafers expands, ensuring reliable Total Thickness Variation (TTV) measurement for stacked wafers becomes essential. This study presents the design of a measurement module capable of measuring TTV across the entire area of a 300mm wafer, along with estimating potential mechanical measurement errors. The module enables full-area measurement by utilizing a center chuck and lift pin for wafer support. Modal analysis verifies the structural stability of the module, confirming that both the driving and measuring parts were designed with stiffness exceeding 100 Hz. The mechanical measurement error of the designed module was estimated, resulting in a predicted measurement error of 1.34 nm when measuring the thickness of a bonding wafer with a thickness of 1,500 ㎛.