• Title/Summary/Keyword: measurement units

Search Result 479, Processing Time 0.028 seconds

Study on Optimized Dispensing of F-18 FDG Auto Dispenser (F-18 FDG 자동분주기의 분주 최적화에 관한 연구)

  • Ji, Bong-Geun;Lee, Sang-Hun;Kim, Jong-Eon;Kim, Won-Tae;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.377-384
    • /
    • 2016
  • This is a study on the optimized dispensing of the auto dispenser used for the purpose of reducing the exposure dose and accurate radiation dose of radioisotope with regard to the PET/CT practitioners. The research method was to find the optimized dispensing method through evaluating the results according to the syringe type, dispensing rate, and vial pressure and through the application of corrected values. As a result of this study, 9.38 mCi has been dispensed on average in the case of 5 ml syringe, and the reproducibility close to 10 mCi was shown at the dispense of 9.55 mCi in the case of 3 ml syringe. In the evaluation according to the dispensing rate, the quantity of radioisotope close to 10 mCi was dispensed at the rate of 5 mm/min when the measurement was carried out by increasing the rate by 5 mm/min units in the order of 5, 10, 15 and 20 mm/min. In the evaluation result according to the vial pressure before/after the use of Needle filter, it was measured to be 9.53 mCi before use and 9.84 mCi after use confirming that the dispensing after using Needle filter showed the optimal value. In addition, in the evaluation of radioactivity before/after the application of corrected values according to the increase in dispense frequency, it was measured 9.53 mCi before correction and 10.07 mCi after correction confirming that the value with correction applied was closer to the quantitative value. Thus, a good optimized method was confirmed to use a 3 ml syringe with dispensing rate of 5 mm/min, to use a Needle filter at dispensing, and to set the corrected value of [$y=0.097{\times}x$] according to the dispensing frequency of equipment.

Comparison of relative fitness between zirconia single coping and 3-unit fixed partial dentures (FPDs) manufactured by dental CAD/CAM system (치과 캐드/캠 시스템으로 제작된 지르코니아 single 코핑과 3-unit 구조물의 상대적 적합도 비교)

  • Lee, Wan-Sun;Park, Jong-Kyoung;Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2014
  • Purpose: The purpose of this study was to assess the marginal and mesial fitness of zirconia single copings and 3-unit fixed partial dentures (FPDs) manufactured with an identical model. Materials and Methods: An epoxy model in which the maxillary right 2nd premolar is lost and maxillary 1st premolar and 2nd molar are formed as abutments was manufactured and scanned by using a laser scanner. A ten units of zirconia single copings were manufactured for maxillary 1st premolar and 2nd molar, respectively and the same number of 3-unit FPDs were manufactured. For the measurements of fitness, the manufactured silicone replicas were divided into four parts and the fitness were measured by digital microscope at measurement points (P1, P2, P3, P4 and P5) of each plane. The measured gaps were classified into three categories: marginal gap (MG, P1), axial gap (AG, average of P2 and P3), occlusal gap (OG, average of P4 and P5). Results: The ranges of MG, AG and OG for single copings were 18.47 - 40.54 ${\mu}m$, 39.73 - 73.61 ${\mu}m$ and 116.90 - 134.69 ${\mu}m$, respectively. The ranges of MG, AG and OG for 3-unit FPDs were 45.95 - 87.44 ${\mu}m$, 23.78 - 57.00 ${\mu}m$ and 99.89 - 131.06 ${\mu}m$, respectively. Conclusion: The result of the study shows that the MGs for 3-unit FPDs were higher than those of single copings, though they are within the range of clinical acceptance, indicating that the use of more homogeneous zirconia block and modification of sintering processes are needed to ensure the prevention of increase of gap in 3-unit FPDs.

Lessons from Cross-Scale Studies of Water and Carbon Cycles in the Gwangneung Forest Catchment in a Complex Landscape of Monsoon Korea (몬순기후와 복잡지형의 특성을 갖는 광릉 산림유역의 물과 탄소순환에 대한 교차규모 연구로부터의 교훈)

  • Lee, Dong-Ho;Kim, Joon;Kim, Su-Jin;Moon, Sang-Ki;Lee, Jae-Seok;Lim, Jong-Hwan;Son, Yow-Han;Kang, Sin-Kyu;Kim, Sang-Hyun;Kim, Kyong-Ha;Woo, Nam-Chil;Lee, Bu-Yong;Kim, Sung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.2
    • /
    • pp.149-160
    • /
    • 2007
  • KoFlux Gwangneung Supersite comprises complex topography and diverse vegetation types (and structures), which necessitate complementary multi-disciplinary measurements to understand energy and matter exchange. Here, we report the results of this ongoing research with special focuses on carbon/water budgets in Gwangneung forest, implications of inter-dependency between water and carbon cycles, and the importance of hydrology in carbon cycling under monsoon climate. Comprehensive biometric and chamber measurements indicated the mean annual net ecosystem productivity (NEP) of this forest to be ${\sim}2.6\;t\;C\;ha^{-1}y^{-1}$. In conjunction with the tower flux measurement, the preliminary carbon budget suggests the Gwangneung forest to be an important sink for atmospheric $CO_2$. The catchment scale water budget indicated that $30\sim40%$ of annual precipitation was apportioned to evapotranspiration (ET). The growing season average of the water use efficiency (WUE), determined from leaf carbon isotope ratios of representative tree species, was about $12{\mu}mol\;CO_2/mmol\;H_2O$ with noticeable seasonal variations. Such information on ET and WUE can be used to constrain the catchment scale carbon uptake. Inter-annual variations in tree ring growth and soil respiration rates correlated with the magnitude and the pattern of precipitation during the growing season, which requires further investigation of the effect of a monsoon climate on the catchment carbon cycle. Additionally, we examine whether structural and functional units exist in this catchment by characterizing the spatial heterogeneity of the study site, which will provide the linkage between different spatial and temporal scale measurements.

A study on the Logical Reclassification of Parcel Service Tariffs (택배요금기준의 합리적 재설정에 관한 연구)

  • Cho, Yoon-Sung;Lee, Tae-Hwee
    • Journal of Distribution Science
    • /
    • v.10 no.5
    • /
    • pp.45-55
    • /
    • 2012
  • In Korea, the parcel delivery service was launched officially in 1992, and the market has grown to 13.2 billion units, or 3.5 trillion won, as of 2011. The service companies accept small packages under 30 kg and deliver them on the next day in most domestic areas. This service plays an important role in business and personal activities. The parcel service companies have themselves designed the tariff for the delivery service based on two criteria: weight and the sum of three side lengths. Further, the tariff is graded in steps of three or four rate structures based on size (small, medium, large, and extra-small). However, the basic freight rate is generally decided according to the cargo's weight or measurement size, and an extra rate is added according to some factors (handling, stowability, liability, and so on). The parcel service tariff adopted by the companies is illogically designed, and this study was carried out to assess the need for redesigning the tariff structure. The cargo volume cannot be logically reflected by three side lengths. For example, two parcels measuring 160 cm based on three side lengths may have different volumes, one measuring 0.152 cbm (53.33 cm × 53.33 cm × 53.34 cm) and the other 0.05 cbm (100 cm × 50 cm × 10 cm). A small package of less than120 cm (sum of three side lengths) may have a volume of as much as 0.064 cbm (40 cm × 40 cm × 40 cm). Sample comparison showed that 17% of medium-size parcels (based on the sum of three side lengths) are small-volume packages, 24% of large-size parcels are small- or medium-volume packages, and 40% of extra-big-size parcels are big- or under-size packages. Therefore, if parcel service companies rate their services for volume cargo based on the three side lengths standard, users may have to pay higher than normal rates, particularly because a large percentage of parcels are volume cargo. According to this study, the average weight per 1 cbm is less than 300 kg. Therefore, users face an increasing risk of paying higher than logical freight charges. Generally, transportation companies are called "public interest enterprises," and parcel service companies operate as postal services. Public interest enterprises must provide the delivery service to all customers without discrimination at a reasonable service level and logical service charges. Therefore, parcels service tariffs must be designed and adopted logically. In this study, freight theories and prior research findings were used to consider the importance of freight rates, and distortion of parcel service rates based on the three side lengths system was verified through regression analysis of a parcel sample and sample comparison. In conclusion, volume sizes based on three side lengths have a higher correlation to the rate level than does the sum of three side lengths. Further, compared to the sum of three side lengths, volume size has a higher correlation to cargo weight, which is the most basic factor determining transportation cost. Therefore, the existing parcel service tariff should be changed to weight- and volume-based rates, and the tariff must be graded in steps of 8 to 10 higher rate structures for a logical freight schedule based on service cost.

  • PDF

The Protective Effect of Inhaled Heparin, Cromolyn, Budesonide, and Furosemide on Exercise-induced Asthma (운동유발성 천식의 기관지 수축에 대한 Heparin, Cromolyn, Budesonide, Furosemide 흡입 치료의 효과)

  • Lee, Sin-Hyung;Shim, Jae-Jeong;Lee, Sang-Youb;Cho, Jae-Youn;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.6
    • /
    • pp.1188-1198
    • /
    • 1998
  • Background : The purpose of the present study was to determine the protective effect of antiasthmatic activity of inhaled heparin, cromolyn sodium, budesonide, furosemide in exercise-induced asthma(EIA). The other important considerable point of this study was the mechanism of bronchoconstriction on EIA. Methods : Eight subjects with a history of EIA were studied on 5 different experiment days. After obtaining baseline $FEV_1$ and FVC, subjects performed a standardized exercise challenge. EIA was assessed by measurement of $FEV_1$ before and after exercise. On experiment day 4, the exercise challenge was performed after the subjects inhaled either heparin (1,000 units/kg/day for 5 days), furosemide (1mg/kg for 5 days), cromolyn (4mg/day for 5 days), or budesonide ($400{\mu}g/day$ for 5 days). On experiment day 5, the methacholine bronchial provocation test was performed. On experiment day 3, activated partial thromboplastine time(aPTI) was checked. Results : Maximum decrements of $FEV_1$ (mean${\pm}$SE) among 0 to 120 minutes after exercise were as follows : heparin was $83.1{\pm}4.81%$ (p=0.010), furosemide was $80.5{\pm}6.87%$ (p=0.071), cromolyn was $86.8{\pm}6.53%$ (p=0.340), and budesonide was $79.4{\pm}7.31%$ (p=0.095). Above medications were compared to the control value ($72.5{\pm}18.2%$) by paired t-test. No medications had effect on $PD_{20}$ of methacholine bronchial provocation test The results were control $1.58{\pm}0.49{\mu}mol$), heparin ($4.17{\pm}1.96{\mu}mol$), furosemide ($1.85{\pm}0.86{\mu}mol$), cromolyn ($2.19{\pm}0.89{\mu}mol$), and budesonide ($3.38{\pm}1.77{\mu}mol$), respectively(p>0.05). The inhaled heparin had no effect of anticoagulation. Conclusion : These data demonstrate that inhaled heparin has a protective effect on EIA. The effect of inhaled cromolyn was statistically absent with manufacture's recommended dosage on EIA. So, the dosage of cromolyn should be carefully evaluated in future. Although inhalation of budesonide and furosemide have no statistical significance compared to control, these drugs also have some protective effects on EIA.

  • PDF

Evaluation of Dose Reduction of Cardiac Exposure Using Deep-inspiration Breath Hold Technique in Left-sided Breast Radiotherapy (좌측 유방암 방사선 치료에서 깊은 들숨 호흡법을 이용한 심장 선량 감소 평가)

  • Jung, Joo-Young;Kim, Min-Joo;Jung, Jae-Hong;Lee, Seu-Ran;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.278-283
    • /
    • 2013
  • Breast cancer is the leading cause of cancer death in women worldwide and the number of women breast cancer patient was increased continuously. Most of breast cancer patient has suffered from unnecessary radiation exposure to heart, lung. Low radiation dose to the heart could lead to the worsening of preexisting cardiovascular lesions caused by radiation induced pneumonitis. Also, several statistical reports demonstrated that left-sided breast cancer patient showed higher mortality than right-sided breast cancer patient because of heart disease. In radiation therapy, Deep Inspiration Breath Hold (DIBH) technique which the patient takes a deep inspiration and holds during treatment and could move the heart away from the chest wall and lung, has showed to lead to reduction in cardiac volume and to minimize the unnecessary radiation exposure to heart during treatment. In this study, we investigated the displacement of heart using DIBH CT data compared to free-breathing (FB) CT data and radiation exposure to heart. Treatment planning was performed on the computed tomography (CT) datasets of 10 patients who had received lumpectomy treatments. Heart, lung and both breasts were outlined. The prescribed dose was 50 Gy divided into 28 fractions. The dose distributions in all the plans were required to fulfill the International Commission on Radiation Units and Measurement specifications that include 100% coverage of the CTV with ${\geq}95%$ of the prescribed dose and that the volume inside the CTV receiving >107% of the prescribed dose should be minimized. Scar boost irradiation was not performed in this study. Displacement of heart was measured by calculating the distance between center of heart and left breast. For the evaluation of radiation dose to heart, minimum, maximum and mean dose to heart were calculated. The present study demonstrates that cardiac dose during left-sided breast radiotherapy can be reduced by applying DIBH breathing control technique.

A Study on Characteristics of Airborne Asbestos Concentrations at Demolition Sites and Surrounding Areas of Asbestos Containing Buildings in Seoul (서울시내 건축물 석면해체·제거 사업장 및 주변에서의 공기 중 석면농도 특성에 관한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jeongyeun;Kim, Jihui;Chung, Sooknye;Kim, Jina;Kim, Iksoo;Eo, Soomi;Jung, Kweon;Lee, Jinsook;Koo, Jayong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.434-441
    • /
    • 2014
  • This study is purposed to measure airborne asbestos concentrations at demolition sites and surrounding areas of asbestos containing buildings in Seoul and examine whether the measurement results correspond with allowable exhaust standard for asbestos of the Asbestos Safety Control Act. The airborne asbestos concentrations for 37 sites were below the detection limit ($7fiber/mm^2$) in 101 (35%) out of 288 samples. The whole average airborne asbestos concentration in 37 sites was $0.003{\pm}0.002f/cc$(max 0.0013 f/cc) and almost the whole airborne asbestos concentrations were satisfied with allowable exhaust standard for asbestos, 0.01 f/cc, of the Asbestos Safety Control Act. So possibility of asbestos exposure is not yet a major concern at current levels for sites demolished of asbestos containing buildings in Seoul. Looking at each sampling point, the average airborne asbestos concentrations in boundary line of site, entrance of sanitation, around the workplace (in), around the workplace (out), negative pressure units, storage area for waste, outlet for waste and residential area of residents were respectively $0.002{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.005{\pm}0.004f/cc$, $0.005{\pm}0.003f/cc$ and $0.003{\pm}0.002f/cc$. As a result, all sampling points of study were satisfied with allowable exhaust standard for asbestos, 0.01 f/cc, of the Asbestos Safety Control Act.

An Empirical Comparison and Verification Study on the Containerports Clustering Measurement Using K-Means and Hierarchical Clustering(Average Linkage Method Using Cross-Efficiency Metrics, and Ward Method) and Mixed Models (K-Means 군집모형과 계층적 군집(교차효율성 메트릭스에 의한 평균연결법, Ward법)모형 및 혼합모형을 이용한 컨테이너항만의 클러스터링 측정에 대한 실증적 비교 및 검증에 관한 연구)

  • Park, Ro-Kyung
    • Journal of Korea Port Economic Association
    • /
    • v.34 no.3
    • /
    • pp.17-52
    • /
    • 2018
  • The purpose of this paper is to measure the clustering change and analyze empirical results. Additionally, by using k-means, hierarchical, and mixed models on Asian container ports over the period 2006-2015, the study aims to form a cluster comprising Busan, Incheon, and Gwangyang ports. The models consider the number of cranes, depth, birth length, and total area as inputs and container twenty-foot equivalent units(TEU) as output. Following are the main empirical results. First, ranking order according to the increasing ratio during the 10 years analysis shows that the value for average linkage(AL), mixed ward, rule of thumb(RT)& elbow, ward, and mixed AL are 42.04% up, 35.01% up, 30.47%up, and 23.65% up, respectively. Second, according to the RT and elbow models, the three Korean ports can be clustered with Asian ports in the following manner: Busan Port(Hong Kong, Guangzhou, Qingdao, and Singapore), Incheon Port(Tokyo, Nagoya, Osaka, Manila, and Bangkok), and Gwangyang Port(Gungzhou, Ningbo, Qingdao, and Kasiung). Third, optimal clustering numbers are as follows: AL(6), Mixed Ward(5), RT&elbow(4), Ward(5), and Mixed AL(6). Fourth, empirical clustering results match with those of questionnaire-Busan Port(80%), Incheon Port(17%), and Gwangyang Port(50%). The policy implication is that related parties of Korean seaports should introduce port improvement plans like the benchmarking of clustered seaports.

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.