• Title/Summary/Keyword: measurement units

Search Result 479, Processing Time 0.027 seconds

Quantitative Analysis of Trace pp'-DDE in Corn Oil by Isotope Dilution Mass Spectrometry : Uncertainty Evaluations

  • 김병주;김달호;최종오;소헌영
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.8
    • /
    • pp.910-916
    • /
    • 1999
  • A current interest in chemistry concerns traceability of analytical measurements to the International System of Units (SI) and the proper estimation of their uncertainties in accordance with the internationally agreed guide provided by the International Organization for Standardization (ISO). Isotope dilution mass spectrometry (IDMS) is regarded as a primary method, which make the measurement results traceable to SI units without significant empirical correction factors. Our laboratory, as the national standards institute of Korea, participated in an intercomparison of environmental analysis, pp'-DDE in corn oil, which was organized by the CCQM under supervision of the CIPM to test feasibility of IDMS as a primary method for the trace analysis of organic compounds. In this report, we provide basic equations used for the calculation of the concentration of the analyte in a sample and a precise description of the processes for the evaluation of the uncertainties of the measurement results. Also, we report the experimental conditions adopted to improve the accuracy of the IDMS measurement. The principles contained in ??Guide to the Expression of Uncertainty in Measurement'' provided by ISO are followed for the uncertainty evaluation.

PLATFORM FOR PRIVACY CONTROL IN LOCATION BASED SERVICES

  • An, Kyoung-Hwan;Min, Kyoung-Wook;Kim, Ju-Wan
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.659-662
    • /
    • 2005
  • Recently, the need for LBS (Location Based Services) is increasing with the rapid growth of the location measurement units, mobile devices, and communication technologies. Especially, wireless carriers are concentrating on LBS since it is regarded as so-called 'killer application' among wireless data services. Although LBS give us convenience and useful information, its use also raises privacy issues. There are quite possibilities that the people's locations are tracked by location measurement units while people do not recognize the existence of the units. To protect a person's location information, lawful and technical aspects should be considered. In this paper, we explain issues, regulations, standards, and platforms related to the protection of the location information. Finally, we suggest the architecture of a platform complying with the regulations and standards. It considers various issues not covered in other studies.

  • PDF

Pain Perception of Nurses and Pain Expression of Patients in Critical Care Units (중환자실 내 간호시술에 대한 간호사의 통증인식과 환자의 통증반응)

  • Bae, Kyung Hee;Jeong, Ihn Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.4
    • /
    • pp.437-445
    • /
    • 2014
  • Purpose: This study was done to identify pain perception (P-PER) by nurses and pain expression (P-EXP) by patients in critical care units (ICUs) and degree of agreement between nurses' P-PER and patients' P-EXP. Methods: Nurses' P-PER was measured with a self-administered questionnaire completed by 99 nurses working in ICUs during May, 2013. Patients' P-EXP was measured with the Critical Care Non-Verbal Pain Scale through observations of 31 ICU patients during nine nursing procedures (NPs) performed between May and July, 2013. Results: Nurses' P-PER was from 4.49 points for nasogastric tube (NGT) insertion to 0.83 for blood pressure (BP) measurement based on a 9-point scale, Patients' P-EXP was 4.48 points for NGT to 0.18 for BP measurement based on a 10-point scale. Eight NPs except oral care showed higher scores for nurses' P-PER than for patients' P-EXP. Position change (p=.019), subcutaneous injection (p<.001), blood sugar test (p<.001), and BP measurement (p<.001) showed significant differences between nurses' P-PER and patients' P-EXP. Conclusion: Nasogastric tube (NGT) insertion was scored highest by both nurses and patients. Eight NPs except 'oral care' showed nurses' P-PER was higher or similar to patients' P-EXP, which indicates that nurses may overestimate procedural pain experienced by patients.

A Guide to Education on Unit Transformation in University Liberal Arts Education (대학 교양교육에서 단위변환에 대한 교육 방향 제시)

  • kyung a jeong;hye jeong kim
    • Journal of Integrative Natural Science
    • /
    • v.16 no.4
    • /
    • pp.133-138
    • /
    • 2023
  • After the SI system of units was adopted as an international system of units, Korea made a lot of efforts such as administrative and educational guidance on the traditional units that had been used so far. In addition, from July 1, 2007, the government has cracked down on the denotation of non-statutory units of measurement as standard units or auxiliary units in commercial transactions. However, non-statutory weighing units are still used in other forms. It is believed that this is because non-statutory units (= our traditional units) are permeated in our lives and are convenient to use. The general public still finds it difficult to use and mark the SI system of units correctly. This is not a problem unique to Korea. However, if you look at the books that are currently used as university physics textbooks, the SI system of units and the non-legal units of other countries are marked in such a way that they can be accurately converted. Only the traditional units of our country are disappearing under the pretext of unit unification. Accordingly, we propose that our units should not be neglected in university education, but should be labeled together. The purpose of this study is to raise the necessity of reorganizing the unit conversion between the SI unit system and the traditional life improvement unit, which continues to be the convenience of life, and applying it in university physics education to enable the conversion with our traditional unit, and to educate the importance of the meaning and function of our traditional unit.

Evaluation of the Spring Constant of a Micro Coil Spring (마이크로 코일 스프링의 스프링 상수 평가)

  • Lee J. K.;Jeon B. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.255-259
    • /
    • 2001
  • The spring constant of a micro coil spring was measured by uniaxial tensile test. The inner diameter of it is $35{\mu}m$ and the pitch size is about $23{\mu}m$. A suing constant measurement system was developed. It consists of control units, load cell units, linear stages and several specially designed jigs and fixtures. Load and displacement are measured using a commercial load cell of 1000g capacity and a magnetic scale of $0.5{\mu}m$ resolution. In this study, a method to measure the spring constant of micro coil spring is presented and the relationship between misalignment of specimen and measurement error is discussed.

  • PDF

Optimal Placement of Synchronized Phasor Measurement Units for the Robust Calculation of Power System State Vectors (견실한 전력계통 상태벡터 계산을 위한 동기 페이저 측정기 최적배치)

  • Cho, Ki-Seon;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.75-79
    • /
    • 2000
  • This paper proposes the optimal placement with minimum set of Phasor Measurement Units (PMU's) using tabu search and makes an alternative plan to secure the robustness of the network with PMU's. The optimal PMU Placement (OPP) problem is generally expressed as a combinatorial optimization problem subjected to the observability constraints. Thus, it is necessary to make a use of an efficient method in solving the OPP problem. In this paper, a tabu search based approach to solve efficiently this OPP problem proposed. The observability of the network with PMU's is fragile at any single PMU contingency. To overcome the fragility, an alternative scheme that makes efficient use of the existing measurement system in power system state estimation proposed. The performance of the proposed approach and the alternative scheme is evaluated with IEEE sample systems.

  • PDF

An Initial Placement Strategy for Optimal Placement of Phasor Measurement Units in Power Systems (페이저 측정기 치적배치를 위한 초기 배치 전략)

  • Cho, Ki-Seon;Shin, Joong-Rin;Park, Jong-Bae;Chae, Myung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.342-344
    • /
    • 2002
  • This paper presents a new strategy to find starting points for placing optimally Phasor Measurement Units(PMUs). The performance of the starting point, initial placement set of PMUs, affect critically the computational burden and/or time, because the Optimal PMU Placement (OPP) problem is formulated the combinatorial optimization. By analyzing the properties of OPP solutions on IEEE sample systems in detail, a new strategy for initial PMU placement, in this paper, is proposed. To verify the performance of the suggested strategy, the comparison with the existing strategy and the new one, on IEEE sample systems. is performed. By using the new strategy, the numbers of search spaces to solve the OPP problem is drastically decreased.

  • PDF

Hierarchically Associated Quality Performance Measurements in Quality Management (계층유대에 의한 품질경영 성과측정)

  • Shin, Wan-Seon
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.2
    • /
    • pp.163-182
    • /
    • 1999
  • Performance measurement is increasingly becoming a vital issue for promoting quality management within an organization. This research proposes a new performance measurement approach, called the Hierarchically Associated Performance Measurement, for the organizations which emphasize long term quality th겨st through a balanced interface between the quality efforts of various units. The proposed approach is unique in that it considers relationships between internal quality activities and national quality award criteria and that it identifies and utilizes the quality responsibilities of functional units in order to encompass organizational roles in the evaluation process. The approach is illustrated via a numerical evaluation of a fictitious organization.

  • PDF

Estimation Technique of Power Transmission Line Parameter by Phasor Measurement Units (송전선로 파라메터 정밀 예측을 위한 페이저 측정기의 응용)

  • Cho, Ki-Seon;Park, Jong-Bae;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.193-195
    • /
    • 2003
  • This paper presents an approach to estimate the power transmission line parameter by phasor measurement units(PMUs), which are synchronized to 1 pps signal of GPS. Existing approaches to estimate power transmission line parameter, are mainly off-line ones, based on faults or switching events on other neighboring lines. In this paper, to obtain static and dynamic properties of power transmission line parameter in service, the prototype of pmu-based Transmission Line Parameter Monitoring System (TLPMS) is proposed. Also, an technique to estimate parameters of transmission line described as 2-port network model and the soundness of estimated parameters are addressed.

  • PDF

Optimal Placement of the Phasor Measurement Units in Power System (전력계통의 페이저 측정기 최적배치)

  • Kim, Jae-Hun;Jo, Gi-Seon;Kim, Hoi-Chul;Shin, Jung-Rin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.313-322
    • /
    • 2000
  • This paper presents optimal placement of minimal set of Phasor Measurement Units (PMU's) and observability analysis of the network with PMU's. In order to find a observable system, a symbolic method which directly assigns an appropriate symbol for measurement or pseudo-measurement to every entry of node-branch incidence matrix is proposed. It is much simpler and easier to analyze the observability of the network with PMU's than the conventional ones. For the optimal PMU placement problem, two approaches which are based on a modified Simulated-Annealing (SA) method and a Direct Combination method are proposed. Some case studies with IEEE sample system are made to show the performance of the proposed methods are almost alike and more effective than the conventional simulated-annealing method. It is also shown that the Direct Combination method is more effective than the modified simulated-annealing one in the sense of computation burden. The results of this study showed also that the accuracy of power system estimation and system observability can be improved the proposed PMU placements.

  • PDF