• 제목/요약/키워드: measurement uncertainty

검색결과 918건 처리시간 0.021초

시험장비의 특성을 고려한 진동시험결과에 대한 측정불확도 추정 (Measurement Uncertainty of Vibration Testing Result with Including Uncertainty of Testing Facilities)

  • 문석준;정정훈
    • 한국소음진동공학회논문집
    • /
    • 제26권7호
    • /
    • pp.781-786
    • /
    • 2016
  • All measurements are subject to uncertainty and a measurement result is complete only when it is accompanied by a statement of the associated uncertainty. By international agreement, this uncertainty has a probabilistic basis and reflects incomplete knowledge of the quantity value. The "Guide to the Expression of Uncertainty in Measurement", commonly known as the GUM, is the definitive document on this subject. The requirements for estimation of measurement uncertainty apply to all results provided by calibration laboratories and results produced by testing laboratories under the optional circumstances. In this paper, a procedure for estimation of measurement uncertainty from vibration testing is proposed on KS F 2868:2003 as an example. Both Type A and Type B evaluation of uncertainty are considered to calculate the combined standard uncertainty and expanded uncertainty.

측정 불확도 모형 분류 및 평가 (Model Classification and Evaluation of Measurement Uncertainty)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제9권1호
    • /
    • pp.145-156
    • /
    • 2007
  • This paper is to propose model classification and evaluation of measurement uncertainty. In order to obtain type A and B uncertainty, variety of measurement mathematical models are illustrated by example. The four steps to evaluate expanded uncertainty are indicated as following; First, to get type A standard uncertainty, measurement mathematical models of single, double, multiple, design of experiment and serial autocorrelation are shown. Second, to solve type B standard uncertainty measurement mathematical models of empirical probability distributions and multivariate are presented. Third, type A and B combined uncertainty, considering sensitivity coefficient, linearity and correlation are discussed. Lastly, expanded uncertainty, considering degree of freedom for type A, B uncertainty and coverage factor are presented with uncertainty budget. SPC control chart to control expanded uncertainty is shown.

소닉노즐의 유량측정 불확도 평가 (Evaluation of Flow Measurement Uncertainty of Sonic Nozzle)

  • 최해만;박경암;최용문;오연균;윤병로
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.601-606
    • /
    • 2001
  • Measurement uncertainty should be evaluated according to ISO/IEC 17025. In Flow measurement area, uncertainty evaluation scheme was applied to the reference flow meter, sonic nozzle. Uncertainty was calculated by evaluating various uncertainty factors affected in flow measurement. The expanded uncertainty of the sonic nozzle was 0.21 % (confidence level of 95 %). This evaluation example will be useful in flow measurement uncertainty determination of other flow meters.

  • PDF

식이보충제로 사용되는 히알루론산의 분석법에 대한 불확도 산정 (Measurement Uncertainty for Analytical Method of Hyaluronic Acid Used as a Dietary Supplement)

  • 박상욱;김형범;김광준;이원재
    • KSBB Journal
    • /
    • 제32권1호
    • /
    • pp.54-62
    • /
    • 2017
  • This study aimed to estimate the measurement uncertainty related to determination of hyaluronic acid used as a dietary supplement by high-performance liquid chromatography. According to the guidelines of the Association of Official Analytical Chemists, the analytical processes for determination of hyaluronic acid were performed. And the measurement uncertainty obtained during the analytical processes were expressed in accordance with mathematical/ statistical guidances of GUM (Guide to the Expression of Uncertainty in Measurement) & EURACHEM (Focus for Analytical Chemistry in Europe) for the analytical operations. For the uncertainty in measurement produced based on this analytical method, the expanded uncertainty was calculated by using the relative standard uncertainty between analytical results and sources of uncertainty in measurement (sample weight, final volume, extraction volume, standard solution, matrix and instrument etc). In the results of 95% confidence interval, it was calculated that the uncertainty in measurement was $57.75{\pm}8.76{\mu}g/kg$ (k=2.0). Therefore, it showed that the measurement uncertainty obtained by this analytical method influences on 15.2% of the contents of hyaluronic acid as the analytical results.

공동주택 경량바닥충격음 측정불확도 추정에 관한 연구 (A Study on Estimation of Uncertainty in Measurement of Light Impact Sound Insulation of Floors)

  • 고종철;이종인;김현배;이철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1409-1416
    • /
    • 2006
  • In measuring, uncertainty in measurement is essential to improve measuring reliability. Currently, however, in measuring impact sound insulation of floors, there are no guidelines to estimate uncertainty in measurement. In addition, the concept of uncertainty in rating is required to recognize the relation between measuring and rating. Therefore, through this paper, the efforts have been made to establish uncertainty in measurement and rating of light impact insulation of floors. The result of estimating of uncertainty in measurement and rating in our laboratory is considered reliable, considering ${\pm}0.46{\sim}1.44dB$ of uncertainty in measurement and 1 dB of uncertainty in rating.

  • PDF

측정불확도의 개념과 GUM (The Concept of Measurement Uncertainty and the GUM)

  • 이종화
    • 대한화학회지
    • /
    • 제67권5호
    • /
    • pp.319-332
    • /
    • 2023
  • Guide to the Expression of Uncertainty in Measurement (GUM)가 발간된 1993년부터 측정불확도는 측정학의 핵심 개념으로 여겨져 왔으며 적절한 불확도 평가의 중요성은 꾸준히 높아지고 있다. 하지만 측정불확도의 개념과 GUM에 대해 충분히 정확하고 상세하게 설명하는 국문 자료는 거의 없는 실정이다. 본 총설은 측정불확도 개념과 GUM의 수학적, 역사적, 철학적 배경을 상세하게 설명하며 화학 분야 불확도 평가의 특수성을 논한다.

유량계 교정장치의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Flowmeter Calibrator)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석 (Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test)

  • 양인영
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

GUM 기반 측정불확도의 평가 및 적용에 의한 품질개선 (A Study on Quality Improvement by Evaluation and Application of GUM-based Measurement Uncertainty)

  • 최인수;허선
    • 품질경영학회지
    • /
    • 제51권3호
    • /
    • pp.419-434
    • /
    • 2023
  • Purpose: Measurement results obtained under non-ideal measurement environment conditions may contain uncertain factors. As a result, the reliability of measurement results may be deteriorated. In this study, we tried to find ways to improve quality by evaluating and applying measurement uncertainty based on GUM. Methods: In the flatness measurement of semiconductor parts, uncertainty factors that could occur under actual environmental conditions of workers were derived, and measurement uncertainties were calculated, and methods for minimizing the main factors affecting the measurement results were analyzed. Results: Depending on the part and the coordinate measuring machine, it was shown that the effect of dispersion caused by repeated measurements as type A uncertainty and the effect of the calibration results of equipment as type B uncertainty have the main influence. Conclusion: Depending on the uncertainty factors of type A and type B and the influence of the total expanded uncertainty, the central value and confidence interval of the initial measurement results showed fluctuations. It is considered that analysis and measures for the main uncertainty factors are needed as quality improvement in the industrial field.

측정 불확도 산정 및 표현 (Expression of Uncertainty in Measurement)

  • 최성운
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2005년도 추계학술대회
    • /
    • pp.401-404
    • /
    • 2005
  • The ISO 'Guide to the Expression of Uncertainty in Measurement (GUH) establishes a unified method for evaluating uncertainty in measurement worldwide. This paper discusses the concepts and procedures of uncertainty evaluation.

  • PDF