• Title/Summary/Keyword: measurement tool and analysis methods

Search Result 238, Processing Time 0.025 seconds

COEX-Seq: Convert a Variety of Measurements of Gene Expression in RNA-Seq

  • Kim, Sang Cheol;Yu, Donghyeon;Cho, Seong Beom
    • Genomics & Informatics
    • /
    • v.16 no.4
    • /
    • pp.36.1-36.3
    • /
    • 2018
  • Next generation sequencing (NGS), a high-throughput DNA sequencing technology, is widely used for molecular biological studies. In NGS, RNA-sequencing (RNA-Seq), which is a short-read massively parallel sequencing, is a major quantitative transcriptome tool for different transcriptome studies. To utilize the RNA-Seq data, various quantification and analysis methods have been developed to solve specific research goals, including identification of differentially expressed genes and detection of novel transcripts. Because of the accumulation of RNA-Seq data in the public databases, there is a demand for integrative analysis. However, the available RNA-Seq data are stored in different formats such as read count, transcripts per million, and fragments per kilobase million. This hinders the integrative analysis of the RNA-Seq data. To solve this problem, we have developed a web-based application using Shiny, COEX-seq (Convert a Variety of Measurements of Gene Expression in RNA-Seq) that easily converts data in a variety of measurement formats of gene expression used in most bioinformatic tools for RNA-Seq. It provides a workflow that includes loading data set, selecting measurement formats of gene expression, and identifying gene names. COEX-seq is freely available for academic purposes and can be run on Windows, Mac OS, and Linux operating systems. Source code, sample data sets, and supplementary documentation are available as well.

Correlation between Pediatric Balance Scale(PBS) and Gross Motor Function Measurement(GMFM) Scores in Children with Cerebral Palsy (뇌성마비 아동의 소아 균형검사(PBS)와 대동작기능평가(GMFM)와의 상관관계)

  • Ko, Myung-Sook;Chung, Jae-Hoon;Jeon, Hye-Seon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.2
    • /
    • pp.281-288
    • /
    • 2010
  • Purpose : The purpose of this study was to examine the correlation between Pediatric Balance Scale(PBS) and Gross Motor Function Measurement(GMFM) with cerebral palsy(CP) children. Methods : 31 ambulatory children with CP were recruited for this study. PBS is a modified version of the Berg’s Balance Scale to access the children with motor impairments. To access the motor functions that directly influence to the functional independence of the ambulatory CP children, total scores of standing category and walking/running/jumping category of GMFM were selectively compared with PBS score by Spearman correlation coefficient analysis. Results : The results revealed high correlation between PBS and GMFM scores both in standing and walking/running/jumping categories(r=.9). Conclusions : Therefore, this study indicates that PBS can be applied not only as a tool to access balance, but also as a measurement to predict and access the level of standing and ambulatory related functions of children with CP.

Thermal Expansion Coefficient Measurement of STS430 by Laser Speckle Interferometry (레이저 스페클간섭법에 의한 STS430의 열팽창계수 측정)

  • 김경석;이항서;정현철;양승필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.29-33
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,000$^{\circ}C$. Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 800$^{\circ}C$. There needs to measure the data up to 800$^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000$^{\circ}C$. In previous studies related to thermal strain analysis, the quantitative results are not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,000$^{\circ}C$and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow 600$^{\circ}C$ however, there is some difference up to 600$^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 800$^{\circ}C$. The reason is the phase transformation of STS430 probably begins at 800$^{\circ}C$.

  • PDF

Thermal Expansion Coefficient Measurement of STS430 at High Temperature by In-plane ESPI (In-plane ESPI를 이용한 고온에서 STS430의 열팽창계수 측정)

  • 김경석;강기수;장호섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.69-74
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,00$0^{\circ}C$ . Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 80$0^{\circ}C$ . There needs to measure the data up to 80$0^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000'E In previous studies related to thermal strain analysis, the quantitative results have not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,00$0^{\circ}C$ and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow $600^{\circ}C$ however, there is some difference up to $600^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 80$0^{\circ}C$ . The reason is the phase transformation of STS430 probably begins at 80$0^{\circ}C$

Design and Implementation of Bioluminescence Signal Analysis Tool

  • Jeong, Hye-Jin;Lee, Byeong-Il;Hwang, Hae-Gil;Song, Soo-Min;Min, Jung-Joon;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.12
    • /
    • pp.1580-1587
    • /
    • 2006
  • The term molecular imaging can be broadly defined as the in vivo characterization and measurement of biologic processes at the cellular and molecular level. Optical imaging that has highly reproducibility and repetition used in molecular imaging research. In the bioluminescence imaging, animals carrying the luciferase gene are imaged with a cooled CCD(Charge-Coupled Device) camera to pick up the small number of photons transmitted through tissues. Molecular imaging analysis will allow us to observe the incipience and progression of the disease. But hardware device for molecular imaging and software for molecular image analysis were dependent on imports. In this paper, we suggest image processing methods and designed software for bioluminescence signal analysis. And we demonstrated high correlation(r=0.99) between our software's photon counts and commercial software's photon counts. ROI function and processing functions were accomplished without error. This study have the importance of the development software for bioluminescence image processing and analysis. And this study built the foundations for creative development of analysis methods. We expected this study lead the development of image technology.

  • PDF

Reliability of Ultimate Settlement Prediction Methods (연약지반 장기 침하량 예측기법의 신뢰성 평가)

  • 우철웅;장병욱;송창섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.6
    • /
    • pp.35-41
    • /
    • 1996
  • The theory of consolidation has been achieved remarkable development in terms of theory such as finite consolidation theory, two dimensional Rendulic consolidation theory. Though those theories are well defined, the analysis is by no means straightforward, because associated properties are very difficult to determine in the laboratory, Therefore Terzaghi's one dimensional consolidation theory and Barron's cylindrical consolidation theory are still widely used in engineering practice. The theoretical shortcomings of those consolidation theories and uncertainties of associated properties make inevitably some discrepancy between theoretical and field settlements. Field settlement measurement by settlement plate is, therefore, widely used to overcome the discrepancy. Ultimate settlement is one of the most important factor of embankment construction on soft soils. Nowadays the ultimate settlement prediction methods using field settlement data are widely accepted as a helpful tool for field settlement analysis of embankment construction on soft soils. Among the various methods of ultimate settlement prediction, hyperbolic method and Asaoka's method are most commonly used because of their simplicity and ability to give a reasonable estimate of consolidation settlement. In this paper, the reliability of hyperbolic method and Asaoka's method has been examined using analytical methods. It is shown that both hyperbolic method and Asaoka's method are significantly affected by the direction of drainage.

  • PDF

Receiver operating characteristic curve analysis of the timed up and go test as a predictive tool for fall risk in persons with stroke: a retrospective study

  • Lim, Seung-yeop;Lee, Byung-jun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.2
    • /
    • pp.54-60
    • /
    • 2018
  • Objective: Persons with chronic stroke fall more often than healthy elderly individuals. The Timed Up and Go test (TUG) is used as a fall prediction tool, but only provides a result for the total measurement time. This study aimed to determine the optimal cut-off values for each of the 6 components of the TUG. Design: Retrospective study. Methods: Thirty persons with chronic stroke participated in the study. TUG evaluation was performed using a wearable miniaturized inertial sensor. Sensitivity, specificity, and predictive values were calculated using the Receiver Operating Characteristic (ROC) curve analysis for the measured values in each section. Optimal values for fall risk classification were determined. Logistic regression analysis was used to investigate the risk of future falls based on TUG. Results: The cut-off values of the 6 sections of the TUG were determined, as follows: sit-to-stand >2.00 seconds (p<0.05), forward gait >4.68 seconds (p<0.05), mid-turn >3.82 seconds (p<0.05), return gait >4.81 seconds (p<0.05), end-turn >2.95 seconds (p<0.05), and stand-to-sit >2.13 seconds (p<0.05). The risk of falling increased by 2.278 times when the mid-turn value was >3.82 seconds (p<0.05). Conclusions: The risk of falls increased by 2.28 times when the value of the mid-turn interval exceeded 3.82 seconds. Therefore, when interpreting TUG results, the predictive accuracy for falls will be higher when the measurement time for each section is analyzed, together with the total time for TUG.

An Analysis of Partial Discharge signal Using Wavelet Transforms (웨이블렛 변환을 이용한 부분 방전 신호 분석)

  • 박재준;장진강;임윤석;심종탁;김재환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.169-172
    • /
    • 1999
  • Recently, the wavelet transform has been a new and powerful tool for signal processing. It is more suitable specially for the feature extraction and detection of non-stationary signals than traditional methods such as, the Fourier Transform(FT), the Fast Fourier Transform(FFT) and the Least Square Method etc. because of the characteristic of the multi-scale analysis and time-frequency domain localization. The wavelet transform has been developed for the analysis of PD pulse signal to raise in the progress of insulation degradation. In this paper, the wavelet transform was applied to one foundational method for feature extraction. For the obtain experimental data, a computer-aided partial discharge measurement system with a single acoustic sensor was used. If we are applying to the neural network method the accumulated data through the extracted feature, it is expected that we can detect the PD pulse signal in the insulation materials on the on-line.

  • PDF

The Analysis on the Reliability and Validity of Korean-Version Balance Assessment Tools (한글화된 균형 평가도구들의 신뢰도와 타당도 분석)

  • Jang, Ho-Young;Lee, Jeong-Hoon;Lee, Suk-Min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.4
    • /
    • pp.139-146
    • /
    • 2017
  • PURPOSE: The purpose of this study was to systematically analyze the reliability and validity of the Korean-version of the balance assessment tools. METHODS: Two reviewers of this study independently evaluated the titles of articles and abstracts of studies published until December 2016 through electronic databases (RISS, NDSL, KISS, DBpia) using the keywords "Balance or posture or postural control or postural stability", "Test or assessment or measurement or outcome measure or assessment tool or measurement tool", "Korean version", "Reliability" and "Validity". Regarding the questions considered suitable for the purpose of this study, consensus was reached after reading the full text. Selecting journals suitable for the purpose of the study, they were analyzed as data. RESULTS: The reviewers selected nine papers suitable for the purpose of this study, and Korean-version of the balance assessment tools, included the Berg Balance Scale (BBS), Activities-specific Balance Confidence (ABC) scale, Postural Assessment Scale for Stroke (PASS), Motor Assessment Scale (MAS), Trunk Impairment Scale (TIS), Falls Efficacy Scale (FES), Tinetti-Balance scale, Fullerton Advanced Balance (FAB) scale, and Function In Sitting Test (FIST). Our study showed that the reliability and validity of the Korean-version of the balance assessment tools were high. CONCLUSION: The Korean-version of the balance assessment tools with high reliability and validity would enable physical therapists to make a more accurate evaluation of balance.

Development of the Burnout Scale for General Hospital Nurses (종합병원 간호사의 소진 측정도구 개발)

  • Lee, Sun-Mi;Shin, Hye Sook
    • Journal of East-West Nursing Research
    • /
    • v.29 no.2
    • /
    • pp.95-105
    • /
    • 2023
  • Purpose: The purpose of this study was to develop a measurement tool for burnout in general hospital nurses and verify its reliability and validity. Methods: Construct factors were extracted through an extensive literature review and in-depth interviews with nurses. Psychometric testing was conducted with 550 nurses in a general hospital. Data were analyzed using validity and reliability testing. Results: As a result of factor analysis, 4 factors and 26 items were selected. The burnout factors of general hospital nurses were professional quality of life, work environment excellence, job satisfaction, and negative emotions. The overall coefficient of determination was 46.38%. These factors were validated through convergent, discriminant and concurrent validity testing. The internal consistency reliability was acceptable (Cronbach's α=.91). Conclusions: The Burnout Scale for General Hospital Nurses is a valid and reliable tool that contributes to the assessment of burnout in general hospital nurses. This scale is expected to be used in burnout practice and research of general hospital nurses.