• Title/Summary/Keyword: measurement tool and analysis methods

Search Result 241, Processing Time 0.031 seconds

The effectiveness of nurse-led interventions on quality of life, medication adherence, anxiety, and depression in kidney transplant recipients: A systematic review and meta-analysis (간호사 주도의 중재가 신장이식 수혜자의 삶의 질, 약물 순응도, 불안 및 우울에 미치는 효과: 체계적 문헌고찰 및 메타분석)

  • Park, Seung Yeon;Kwak, Lee Hwa
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.30 no.3
    • /
    • pp.263-279
    • /
    • 2024
  • Purpose: This study was conducted to evaluate the effects of nurse-led interventions on quality of life, medication adherence, anxiety, and depression in kidney transplant recipients. Methods: A systematic literature review was conducted following Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines. Two researchers independently selected the final literature, and the quality assessment was performed using Cochrane's Risk of Bias tool. Additionally, a meta-analysis was conducted using the statistical software RevMan 5.4 to estimate effect sizes. Results: Among the reviewed 2,264 papers, 8 final papers, including 6 from the literature search and 2 from manual searches, were included in the analysis. The total number of participants included in the analysis was 477. Nurse-led interventions were found to be effective in improving quality of life (d=1.05) and reducing anxiety (d=-0.98) and depression (d=-1.25). Due to the heterogeneity of the measurement tools, the effect size for medication adherence could not be calculated. Despite this, nurse-led interventions were shown to improve medication adherence. In the cases of anxiety and depression, longer intervention periods showed a more significant reduction trend. Conclusion: The results of this study suggest that nurse-led interventions positively impact quality of life, medication adherence, anxiety, and depression in kidney transplant recipients. Therefore, it is important to recognize the crucial role of nurses and explore ways to provide continuous nursing interventions for kidney transplant recipients.

Evaluation Method of the Multi-axis Errors for Machining Centers (머시닝센터의 다축오차 평가 방법)

  • Hwang, Joo-Ho;Shim, Jong-Youp;Ko, Tae-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.8
    • /
    • pp.904-914
    • /
    • 2011
  • The volumetric errors of CNC machining centers are determined by 21 errors, including 3 linear errors, 6 straightness errors, 3 perpendicular errors, 9 angular errors and non-rigid body errors of the machine tool. It is very time consuming and hard to measure all of these errors in which laser interferometer and other parts are used directly. Hence, as many as 21 separate setups and measurements are needed for the linear, straightness, angular and perpendicular errors. In case of the 5-axis machining centers, two more rotary tables are used. It can make 35 error sources of the movement. Therefore, the measured errors of multi movements of the 5-axis tables are very complicated, even if the relative measured errors are measured. This paper describes the methods, those analyze the error sources of the machining centers. Those are based on shifted diagonal measurements method (SDM), R-test and Double ball bar. In case, the angular errors of machine are small enough comparing with others, twelve errors including three linear position errors, six straightness errors and three perpendicular errors can be calculated by using SDM. To confirm the proposed method, SDM was applied to measuring 3 axes of machine tools and compared with directly measurement of each errors. In addition, the methods for measuring relative errors of multi-axis analysis methods using R-test and Double Ball Bar are introduced in this paper.

Reproducibility of Trunk Control Assessment and the Clinical Utility of the Distinguishing Barthel Index in Chronic Stroke Patients (만성 뇌졸중 환자들의 체간 조절 평가의 재현성과 Barthel Index구분을 위한 임상 유용성)

  • Seung-Heon An;Dae-Sung Park
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.19 no.3
    • /
    • pp.55-63
    • /
    • 2024
  • PURPOSE: This study examined the test-retest reliability and clinical utility of the Modified Trunk Impairment Scale (mTIS), Trunk Control Test (TCT), and Postural Assessment Scale for Stroke - Trunk Control (PASS-TC) in patients with chronic stroke. METHODS: Thirty-eight stroke patients were reassessed using the mTIS, TCT, and PASS-TC with a seven-day interval between assessments. The test-retest reliability was evaluated using the intraclass correlation coefficient (ICC2,1), the standard error of measurement (SEM), the minimal detectable change (MDC), and MDC%, as well as Bland-Altman analysis. The relationship between the mTIS, TCT, PASS-TC scores, and the Barthel Index (BI) was also investigated. RESULTS: The test-retest reliability for the mTIS, TCT, and PASS-TC was high, with ICC values ranging from .91 to .94 (95% confidence interval: .83-.97). The MDCs for the mTIS and TCT were 2.35 and 13.9, respectively, while the MDC for the P ASS-TC was 2.54, all below 20% of the maximum possible score, indicating reliable measurement. The optimal mTIS cut-off score for distinguishing between mild (75-95 points) and severe (50-74 points) dependence on the BI was ≥ 9.5, with an accuracy of 79%. Patients with an mTIS score ≥ 9.5 (out of 15) showed an 18-fold higher likelihood of achieving a mild level of functional independence than those with a score < 9.5. CONCLUSION: The mTIS, TCT, and PASS-TC showed high test-retest reliability and no systematic errors in chronic stroke patients. The MDC values were reliable, indicating meaningful change. Among these, the mTIS is a sensitive and a useful tool for predicting functional independence in clinical practice and is straightforward to apply.

Reliability and validity of rasterstereography measurement for spinal alignment in healthy subjects

  • Yi, Yoon-Sil;Yoo, Seul-Ki;Lee, Da-Gam;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.1
    • /
    • pp.22-28
    • /
    • 2016
  • Objective: The Back Mapper is one type of Rasterstereography and it can be used in the clinic without radiation exposure. The purpose of our study was to prove the reliability and validity of the Back Mapper and to compare it with the Spinal Mouse, which is an assessment tool for spinal curvatures using a wheeled mouse, and the Cobb angle by X-ray. Design: Cross-sectional study. Methods: Twenty healthy adults participated in the test to investigate for the inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with assessment devices for scoliosis such as the Back Mapper, Spinal Mouse and Cobb's angle. Data was analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement for reliability and correlation analysis for validity. Results: Intra-rater reliability of the Back Mapper was good (Cronbach's ${\alpha}$=0.821-0.984, ICC=0.696-0.969) except for assessing the lordotic angle. Inter-rater reliability was good (Cronbach's ${\alpha}$=0.870-0.958, ICC=0.770-0.919) in assessment for trunk imbalance, rotation of scapulae, thoracic angle, lumbar angle, and kyphotic angle. The kyphotic angle in the Spinal Mouse had a significant correlation icompared with the Back Mapper (r=0.510, p<0.05), and the Cobb's angle from an X-ray had a significant correlation with trunk inclination (r=0.532, p<0.05). Conclusions: These findings provide good intra-reliability of the Back Mapper in healthy subjects, but the Back Mapper requires more experienced practice to have good inter-reliability. Also, the variables of the Back Mapper does not seem as appropriate compared with the Cobb angle by X-ray.

Healthcare Service Consumers' Perception of Patient Safety (환자안전에 대한 의료서비스 소비자의 인식 조사)

  • Kim, Jeong Eun;Lee, Nam Ju;Jang, Seon Mi;Kim, Young Mee
    • Perspectives in Nursing Science
    • /
    • v.10 no.2
    • /
    • pp.133-140
    • /
    • 2013
  • Purpose: This study aimed to investigate the perspective of consumers in healthcare services regarding patient safety. Methods: The study was a descriptive study using a self-reported questionnaire. The questionnaire was based on the Senior Empowerment and Advocacy in Patient Safety (SEAPS) questionnaire, which was designed to assess patient safety health beliefs. The survey was conducted online and a convenient sample of 302 adults participated in total. The reliability of the measurement (Cronbach's ${\alpha}$) was 0.758 in attitude (ATT), 0.546 in out-come efficacy (OE), 0.757 in self-efficacy (SE), and 0.703 in behaviors (BEH). Results: The average patient safety awareness score of the healthcare service consumers was 2.72 (ATT), 2.91 (OE), 2.87 (SE), and 2.27 (BEH). Our analysis indicated that there were no differences in ATT, BEH, or SE by gender, age, or education level. However, in OE and the total score of the four subscales, there were significant differences by age and gender. Correlations were identified between BEH and SE (r=0.409, p<.01), BEH and OE (r=0.202, p<.01), ATT and SE (r=0.358, p<.01), and OE and SE (r=0.241, p<.01). Conclusion: This study measured consumer perspectives concerning patient safety. The findings demonstrate the need for developing a measurement tool to assess consumer's perception of patient safety, considering Korean healthcare system and cultural context.

  • PDF

Development of an Evaluation Method for Flow Rate Performance of Particulate Sampling Pump using Three-pieces Cassette Holder Containing Filters (여과지가 장착된 3단 카세트를 이용한 입자상물질 채취용 펌프의 유량성능 평가방법)

  • Song, Ho-June;Kim, Nam-Hee;Kim, Ki-Youn;Ma, Hye-Lan;Lee, Kwang-Young;Jeong, Jee-Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.348-355
    • /
    • 2013
  • Objectives: In working environment measurement, sampling is an important stage for obtaining reliable result as analysis. A personal air sampling pump is one of the most fundamental and important element in the work environment measurement, but it remains at the level of calibrating the flow rate of the pump before and after sampling. There is no checking whether the flow rate set at the initial stage would be hold during sampling. The purpose of this study was to develop a method to evaluate the flow rate performance of particulate sampling pump with three-pieces cassette holder containing filters commonly used to sample particulate. Materials and methods: We tested back pressure of particulate sampling pumps commonly used in Korea with three-pieces cassette holder containing various filters, and tried to find out the combination conditions of filters in accordance with back pressure required by ISO standard 13137. Results: We found out the matrix of sampling media such as three-pieces cassette holder containing filters applicable to the pressure drop required by the ISO standard for evaluating the flow rate stability under increasing pressure drop and long term(8 hour) performance. Conclusions: This evaluation method using sampling media matrix for checking flow rate stability proposed by this study could be very useful tool to find out good performance pumps before sampling.

Quantitative Evaluation of Median Nerve Motor Function in Carpal Tunnel Syndrome Using Load Cell : Correlation with Clinical, Electrodiagnostic, and Ultrasonographic Findings

  • Kim, Dong Hwan;Park, Sung Bae;Lee, Sang Hyung;Son, Young-Je;Chung, Gih Sung;Yang, Hee-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.232-235
    • /
    • 2013
  • Objective : Major complaints of carpal tunnel syndrome (CTS) are sensory components. However, motor deficit also impedes functional status of hand. Contrary to evaluation of sensory function, the objective, quantitative evaluation of median nerve motor function is not easy. The motor function of median was evaluated quantitatively using load cell and its correlation with findings of electrodiagnostic study (EDS) was evaluated. Methods : Objective motor function of median nerve was evaluated by load cell and personal computer-based measurement system. All of the measurement was done in patients diagnosed as having idiopathic CTS by clinical features and EDS findings. The strength of thumb abduction and index finger flexion was measured in each hand three times, and the average value was used to calculate thumb index ratio (TIR). The correlation of TIR with clinical, EDS, and ultrasonographic findings were evaluated. Results : The TIR was evaluated in 67 patients (119 hands). There were 14 males and 53 females, mean age were 57.6 years (range 28 to 81). The higher preoperative nerve conductive studies grade of the patients, the lower TIR was observed [p<0.001, analysis of variance (ANOVA)]. TIR of cases with thenar atrophy were significantly lower than those without (p<0.001, t-test). TIR were significantly lower in patients with severe median nerve swelling in ultrasonography (p=0.042, ANOVA). Conclusion : Measurements of median nerve motor function using load cell is a valuable evaluation tool in CTS. It might be helpful in detecting subclinical motor dysfunction before muscle atrophy develops.

Developing the Service Quality Scale of Business Center: A New B2B Service Retailing Format (신 서비스유통포맷으로서의 비즈니스센터의 서비스품질 평가척도 개발)

  • Kim, Seung-Sub;Yoo, Dong-Keun;Lee, Phil-Soo
    • Journal of Distribution Science
    • /
    • v.12 no.11
    • /
    • pp.101-111
    • /
    • 2014
  • Purpose - This study aims to verify the construct of the service quality suitable to the characteristics of the business center, to develop the scale that can measure the service quality objectively, compare the diverse business centers in Korea, and present desirable methods of business center management and operation. Research design, data, and methodology - In the first stage, literature research and focus group interviews with current users and actual business experts of business centers were conducted. In addition, 69 early stage scale items were derived. In the second stage, a Delphi survey was conducted on the experts of business and academic circles. The measurement items in the early stage were supplemented and revised. The content validity rate (CVR) of 69 measures was computed and then the experts' opinions were used. As a result, the business center service quality scale, made up of 9 organizing factors and 36 measurement items, was constructed. In the third stage, a survey was conducted on the occupants who were currently using the business center. It was to confirm if the developed business center service quality scale could be actually utilized. The data of 435 samples collected were used. To refine the scale items, the exploratory factor analysis (EFA) was conducted repeatedly. Results - The business center service quality scale, made up of 8 factors and 33 items, was developed again. The 8 factors are reliability, speed, kindness, specialty, responsibility, appearance, convenience, and public interest. The reliability coefficient (Cronbach's Alpha) of each factor is greater than .7. Thus, it was confirmed that there was reliability in the measurement items. Further, the model suitability was verified using the confirmatory factor analysis (CFA), and the convergent validity and the discriminant validity were verified. This proved the construct validity. Through this process, the Korea Business Center Service Quality Scale was developed. Based on factor analysis, the developed business center service quality (BCSQ) scale consists of 4 aspects, 8 factors, and 33 items, comprising the "process quality" aspect: reliability (3 items), speediness (4 items), kindness (3 items) factors, the outcome quality aspect: expertise (3 items), responsibility (5 items) factors, the environment quality aspect: appearance (5 items), convenience (3 items) factors, and the public interest aspect: public interest (7 items) factor. However, according to CFA, the BCSQ scale consists of a total of 4 aspects, 8 factors, and 33 items, comprising the "process quality" aspect: reliability (3 items), speediness (3 items), kindness (3 items) factors, the outcome quality aspect: expertise (2 items), responsibility (4 items) factors, the environment quality aspect: appearance (3 items), convenience (2 items) factors, and the public interest aspect: public interest (3 items) factor. Conclusions - The BCSQ scale could serve as a diagnostic tool that will allow business center managers to determine service areas that are weak and in need of attention, and to improve the service quality of the business center.

Three-dimensional kinematic motion analysis of door handling task in people with mild and moderate stroke

  • Lee, Jung Ah;Kim, Eun Joo;Hwang, Pil Woo;Park, Han Ram;Bae, Jae Hyuk;Kim, Jae Nam
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.143-148
    • /
    • 2016
  • Objective: This study aimed to quantify one of the useful upper extremity movements to evaluate motor control abilities between the groups of people with mild and moderate arm impairments performing a door handling task. Design: Cross-sectional study. Methods: Twenty-one healthy participants and twenty-one persons with chronic stroke (9 mild stroke and 12 moderate stroke) were recruited for this study. Stroke participants were divided into 2 groups based on Fugle-Meyer Assessment scores of 58-65 (mild arm) and 38-57 (moderate arm). All they performed door handling task including the pronation and supination phases 3 times. We measured some movement factors which were reaction time, movement time, hand of peak velocity, hand of movement units to perform door handling task using the three-dimensional motion analysis. Results: The majority of kinematic variables showed significant differences among study groups (p<0.05). The reaction time, total and phase of movement time, hand of peak velocity, the number of movement units discriminated between healthy participants and persons with moderate upper limb stroke (p<0.05). In addition, reaction time, total and phase of movement time, the number of movement units discriminated between those with moderate and mild upper limbs of stroke patients (p<0.05). Conclusions: Three-dimensional kinematic motion analysis in this study was a useful tool for assessing the upper extremity function in different subgroups of people with stroke during the door handling task. These kinematic variables may help clinicians understand the arm movements in door handling task and consist of discriminative therapeutic interventions for stroke patients on upper extremity rehabilitation.

Real-time TVOC Monitoring System and Measurement Analysis in Workplaces of Root Industry (뿌리산업 작업장내 총휘발성유기화합물류(TVOC) 실시간 노출감시체계 구축과 농도 분석)

  • Jong-Hyeok, Park;Beom-Su, Kim;Ji-Wook, Kang;Soo-Hee, Han;Kyung-Jun, Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.425-434
    • /
    • 2022
  • Objectives: This study analyzes TVOC concentrations in root industry workplaces in order to prevent probable occupational disease among workers. Root industry includes all the infrastructure of manufacturing, such as casting and molding. Methods: Real-time TVOC sensors were deployed in three root industry workplaces. We measured TVOC concentrations with these sensors and analyzed the results using a data-analysis tool developed with Python 3.9. Results: During the study period, the mean of the TVOC concentrations remained in an acceptable range, 0.30, 2.15, and 1.63 ppm across three workplaces. However, TVOC concentrations increased significantly at specific times, with respective maximum values of 4.98, 28.35, and 26.65 ppm for the three workplaces. Moreover, the analysis of hourly TVOC concentrations showed that during working hours or night shifts TVOC concentrations increased significantly to higher than twice the daily mean values. These results were scrutinized through classical decomposition results and autocorrelation indices, where seasonal graphs of the corresponding classical decomposition results showed that TVOC concentrations increased at a specific time. Trend graphs showed that TVOC concentrations vary by day. Conclusions: Deploying a real-time TVOC sensor should be considered to reflect irregularly high TVOC concentrations in workplaces in the root industry. It is expected that the real-time TVOC sensor with the presented data analysis methodology can eradicate probable occupational diseases caused by detrimental gases.