• Title/Summary/Keyword: measurement point

Search Result 3,257, Processing Time 0.034 seconds

Analysis of the Dead Layer Thickness effect and HPGe Detector by Penelope Simulation (Penelope Simulation에 의한 불감층 두께 효과 및 HPGe 검출기 분석)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.801-806
    • /
    • 2018
  • Germanium crystals have a dead layer that causes efficiency deterioration because the layer is not useful for detection but strongly weakens the photons. Thus, when the data provided by the manufacturer is used in the detector simulation model, there is a slight difference between the calculated efficiency and the measured efficiency.The shape and dimensions of the high purity germanium (HPGe) detector were determined by CT scans to accurately characterize the shape for the Monte Carlo roll simulation. It is found that the adjustment of the dead layer is a good match with the relative deviation of ${\pm}3%$ between the measurement efficiency and the simulation efficiency at the energy range of 50 - 1500 keV. Simulation data were compared by varying the thickness of the dead layer. The new Monte Carlo simulations were compared with the experimental results to obtain new blank layer thicknesses. The difference in dead layer results for the 1.5 mm thick end cap simulation model in 1.4 and 1.6 mm thick End Cap simulation models was a systematic error due to the accuracy of the end cap dimensions. After considering all errors including statistical errors and systematic errors, the thickness of the detector was calculated as $1.02{\pm}0.14mm$. Therefore, it was confirmed that the increase in the thickness of the dead layer causes the effect to be effected on the efficiency reduction.

CFD Analysis on the Internal Reaction in the SNCR System (SNCR 시스템 내부의 물질 반응에 관한 전산해석적 연구)

  • Koo, Seongmo;Yoo, Kyung-Seun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.63-73
    • /
    • 2019
  • Numerical analysis was done to evaluate the chemical reaction and the reduction rate inside of selective non-catalytic reduction to denitrification in combustion process. The $NO_X$ reduction in selective non-catalytic reduction is converted to not only nitrogen but also nitrous oxide. Simultaneous $NO_X$ reduction and nitrous oxide generation suppressing is required in selective non-catalytic reduction because nitrous oxide influences the global warming as a greenhouse gas. The current study was performed compare the computational analysis in the same temperature and amount of NaOH, and in comparison with the previous research experiments and confirmed the reliability of the computational fluid dynamics. Additionally, controlling the addition amount of NaOH to predict the $NO_X$ reduction efficiency and nitrous oxide production. Numerical analysis was done to check the mass fraction of each material in the measurement point at the end of selective non-catalytic reduction. Experimental Value and simulation value by numerical analysis showed an error of up to 18.9% was confirmed that a generally well predicted. and it was confirmed that the widened temperature range of more than 70% $NO_X$ removal rate is increased when the addition amount of NaOH. So, large and frequent changes of the reaction temperature waste incineration facilities are expected to be effective.

The Longitudinal Interrelationships of Multidimensional Social Exclusion among Married Immigrant Women in Korea (결혼이주여성이 경험하는 다차원적 사회적 배제 영역간의 종단적 상호관계)

  • Park, Hyun-Sun;Jeong, Su Jeong
    • Korean Journal of Family Social Work
    • /
    • no.56
    • /
    • pp.197-224
    • /
    • 2017
  • The purpose of this study was to examine how various dimensions of social exclusion experienced by married immigrant women are affected longitudinally. Autoregressive cross-lagged analysis between sub-dimensions of social exclusion of married immigrant women was conducted to investigate the direction of interrelationships. The data were collected each year through a three-wave longitudinal survey from 2011 to 2013. The results showed that statically significant autoregressive effects appeared among economic exclusion, community exclusion, educational exclusion, and ethnic exclusion. The cross-lagged effects of the sub-dimensions of social exclusion showed that married immigrant women with higher levels of the economic exclusion tend to experience higher levels of the educational exclusion, and ethnic exclusion at the later measurement point, even when controlling for their previous level of social exclusion. It was found that economic exclusion as a more fundamental precedent factor positively predicted other dimensions of social exclusion. The results suggested that financial support and job-related services should be strengthened for active social inclusion of married immigrant women, and early intervention to prevent chronicization of social exclusion should be needed.

Non-contact Stress Measurement in Steel Member of PSC Box Bridge Using Raman Spectroscopy (라만 형광 분광법을 이용한 PSC 박스교 인장케이블 응력측정방법 연구)

  • Kim, Jongwoo;Kim, Namgyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.130-134
    • /
    • 2019
  • In this paper, a laser-based non-contact load cell is newly developed for measuring forces in prestressed concrete tendons. First, alumina particles have been sprayed onto an empty load cell which has no strain gauges on it, and the layer has been used as a passive stress sensor. Then, the spectral shifts in fluorescence spectroscopy have been measured using a laser-based spectroscopic system under various force levels, and it has been found that the relation of applied force and spectral shift is linear in a lab-scale test. To validate the field applicability of the customized load cell, a full-scale prestressed concrete specimen has been constructed in a yard. During the field test, it was, however, found that the coating surface has irregular stress distribution. Therefore, the location of a probe has to be fixed onto the customized load cell for using the coating layer as a passive stress sensor. So, a prototype customized load cell has been manufactured, which consists of a probe mount on its casing. Then, by performing lab-scale uniaxial compression tests with the prototype load cell, a linear relation between compression stress and spectrum shift at a specific point where laser light had been illuminated has been detected. Thus, it has a high possibility to use the prototype load cell as a force sensor of prestressed concrete tendons.

Study on Affecting Factors for the Segmental Joint Behavior of Spliced Girder Bridges (분절교량 접합부 거동의 영향인자에 대한 연구)

  • Nam, Jin-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.9-16
    • /
    • 2019
  • Recently, precast PSC girder bridges have been widely applied for short and middle span bridges. The construction of the spliced girder bridges has been increasing to overcome the length limit of girder and transportation restrictions. In case of the spliced girder, the integrity of the segmental joints is very important to secure the structural soundness of bridge because the discontinuity on the segmental joints between adjacent segments could be vulnerable point. The study of segmental joint behavior with different influence factors of joint type, shear key installation, confining force is very important. In this research, finite element analysis and scaled model test with different shear key shapes and confining forces were carried out and the comparative study was performed to evaluate the segmental joint behavior of precast spliced PSC girder bridge. It was confirmed that the installation of shear key with height and depth ratio of 1/2~1/3 and applying of confining force of 1/2 of the concrete strength at the joint was effective in improving the integrity of segmental joint. In addition, the field loading test for existed precast spliced PSC girder bridge was performed and the measurement of the difference of deflection between adjacent segments at segmental joint was proposed as the assessment solution of the integrity of segmental joint.

A Study on the Estimation of the Minimum Buoyancy for the Respiration of a Drowning Person (익수자의 호흡이 가능한 최소 부력 추정에 관한 연구)

  • Yim, Jeong-Bin;Park, Deuk-Jin;Kang, Yu Mi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.7
    • /
    • pp.820-828
    • /
    • 2017
  • Tools and equipment that can provide buoyancy for a drowning person are important for saving lives. The purpose of this study was to estimate the minimum amount of gas needed and the buoyancy value in newton units required to generate the minimum buoyancy determined to be sufficient for keeping the head of a drowning person above the water's surface to allow for respiration for at least 1 minute. A buoyancy experiment was carried out with a long rubber balloon injected with carbon dioxide gas, and a buoyancy measurement experiment was performed on six college students. The degree of buoyancy was measured using a 5-point scale, and the statistical value of the measured data was analyzed to estimate minimum buoyancy. As a result, 8 grams of carbon dioxide were determined to satisfy minimum buoyancy conditions with a confidence level of 72%, and buoyancy was calculated to be 44.66 newtons. 12 grams of carbon dioxide met the minimum buoyancy conditions with a confidence level of 100%, and buoyancy was calculated to be 66.99 newtons. This study is expected to contribute to the development of low cost, easy-to-carry minimum buoyancy aids.

Relationship between Breathing Pattern Disorder and Joint Position Sense in Patients with Chronic Low Back Pain (만성요통환자의 호흡패턴이상과 관절위치감각의 관계)

  • Cho, Byungyun;Yoon, Junggyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.2
    • /
    • pp.1-10
    • /
    • 2019
  • Purpose : To investigate the relationship between breathing pattern disorder and joint position error (JPE) in patients with chronic low back pain (CLBP). Methods : Thirty nine patients with CLBP participated. End-tidal $CO_2$ and respiration rate (RR) were measured using a capnography. Breathing-hold time (BHT) and Nijmegen Questionnaire (NQ) were investigated. Thoracic excursion was measured with a cloth tape measurement technique. Joint position error were measured using a small laser point mounted on a lightweight headband. they were asked to relocate the head, after the neck movement on the horizontal plane. Pearson 's test was used for correlation analysis between respiratory variables and JPE in patients with CLBP. Independent t-test was used to verify the difference between thoracic and diaphragm breathing pattern in patients with CLBP. The significance level was set at 0.05. Results : There was a significant correlation between JPE (LR) and JPE (RR, EX) (r=.639, r=.813) (p<.001) and a low negative correlation with end-tidal $CO_2$ (r=-.357) (p<.05). There was a significant correlation between RR and JPE (EX) (r=.750) (p<.001). There was a low correlation between JPE (EX) and NQ (r=.333) (p<.05). There was a somewhat high negative correlation between NQ and thoracic excursion (r=-.528) (p<.001). There was a somewhat high negative correlation between thoracic excursion and JPE (LR, RR, EX) (r=-.470, r=-.484, r=-.602) (p<.001). There were no significant differences in the RR, BHT, NQ, and thoracic excursion between the thoracic and diaphragmatic breathing (p>.05). There was a significant difference in the JPE (EX), end - tidal $CO_2$, and VAS values between the thoracic and diaphragm breathing (p<.05). Conclusion : There was a correlation between JPE (EX) and NQ in patients with CLBP, and correlation between thoracic excursion and JPE (LR, RR, EX) and NQ. There was a significant difference in the JPE (EX), end-tidal $CO_2$ level, and VAS value in the comparison of thoracic breathing and diaphragm breathing. The results showed that breathing patterns and JPE were related to each other.

MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil (지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가)

  • Lee, Jun-Ho;Kim, Bong-Gi;Lee, Dong Myung;Byun, Jong-In
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • The detection performances of the NaI(Tl), $LaBr_3$(Ce) and $CeBr_3$ scintillation detectors, which can be used to rapidly evaluate the major artificial radionuclides deposited on the soil surface in a nuclear accident or radiological emergency, were compared. Detection performance was assessed by calculating the minimum detectable activity (MDA). The detection efficiency of each detector for artificial radionuclides was semi-empirically determined using mathematical modelling and point-like sources having certified radioactivity. The background gamma-ray energy spectrum for MDA evaluation was obtained from relatively wide and flat grassland, and the MDA values of each detector for the major artificial radionuclides that could be released in nuclear accidents were calculated. As a result, the relative MDA values of each detector regarding surface deposition distribution at normal environmental radiation level were evaluated as high in the order of the NaI(Tl), $LaBr_3$(Ce), and $CeBr_3$ detectors. These results were compared based on each detector's intrinsic and measurement environment background, detection efficiency, and energy resolution for the gamma-ray energy region of the radionuclide of interest.

Design of Miniaturization Terminal Antenna for 2.4 GHz WiFi Band with MZR (MZR을 이용한 2.4 GHz WiFi 대역 소형 단말기 안테나 설계)

  • Lee, Young-Hun
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.14-21
    • /
    • 2019
  • In this paper, we implemented an on-board miniaturization antenna operating 2.4 GHz using MZR(Mu Zero Resonator). It is must be operating under the constraint that the size of the small terminal PCB should be $78{\times}38{\times}0.8mm^3$ and the size of the system should be $63{\times}38{\times}0.8mm^3$ and the size of the radiating part should be $15{\times}38{\times}0.8mm^3$. The feeding structure uses a CPW structure for stable feeding and a feeding point at the upper left of the system board. A magnetic field coupling structure is used for coupling the feeding part and the antenna. The resonance frequency of the MZR is determined by the series inductance and capacitance of the cell, so the gap between the cells, the length of the cell, the length of the interdigital capacitor, and the spacing between the radiation part and the ground plane are analyzed. The antenna was designed and fabricated using the results. The total size of the antenna including the feed structure is $20.8{\times}9.0{\times}0.8mm^3$, and the electrical length is $0.1664{\lambda}_0{\times}0.072{\lambda}_0{\times}0.0064{\lambda}_0$. The measurement result for 10 dB bandwidth, gain and directivity are 440 MHz(18.3%), 0.4405 dB, and 2.722 dB respectively. It is confirmed that the radiation pattern has omnidirectional characteristics and it can be applied to ultra small terminal antenna.

Studies on the synthesis and characteristics of calcium sulfonate complex grease (칼슘 술폰산염 컴플렉스 그리스 합성과 특성 연구)

  • Woo, Jaegu;Lee, Dongkyu;Ha, KiRyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.8-15
    • /
    • 2019
  • In this study, we synthesized a calcium sulfonate complex grease and a lithium complex grease to investigate their physical, rheological and tribological properties. The thermal stability of the calcium sulfonate was higher than $300^{\circ}C$ and the lithium complex grease was $245^{\circ}C$ in the dropping point test. In the grease viscosity measurement, the calcium sulfonate complex grease was measured as $7.0Pa{\cdot}s$ and the lithium complex grease was as $4.5Pa{\cdot}s$. Therefore, it was confirmed that the calcium sulfonate complex grease is superior to the lithium complex grease in terms of thermal stability and cohesiveness. In the 4-ball wear test, the calcium sulfonate complex grease was measured to be 0.43 mm and the lithium complex grease to 0.85 mm. In the 4-ball extreme pressure test, calcium sulfonate complex grease was measured as 620 kgf and the lithium complex grease was as 125 kgf. Therefore, it was confirmed that the calcium sulfonate complex grease is superior to the lithium complex grease in abrasion resistance and load-bearing property. It was found that the calcium sulfonate complex grease is more effective than the lithium complex grease in the lubrication at high temperature and high load.