• Title/Summary/Keyword: measurement point

Search Result 3,227, Processing Time 0.029 seconds

The Determination of Curie Point of Bulk Gadolinium (Bulk Gadolinium의 Curie점 결정)

  • Lee, Il-Su;Lee, Ui-Wan;Lee, Sang-Yun
    • Korean Journal of Materials Research
    • /
    • v.3 no.4
    • /
    • pp.422-423
    • /
    • 1993
  • In this short note, we report the result of measurement for the ferro- to paramagnetic phase transition temperature, that is Curie point of bulk gadolinium. This note is written to give the solid validity for the previous measurement of Curie point shift of gadolinium film (1. Rhee, E. Lee and S. Lee, Kor. J. of Mat. Research,3, 3, 1993). The Curie point of bulk gadolinium is determined by measuring the resistance of sample as function of temperatures. At Curie point, we can observe the resistivity anomaly which arises due to the heat capacity difference between below and above Curie point. Finally, the curie point of bulk gadolinium is found to be 19.2${\pm}$0.$3^{\circ}C$.

  • PDF

A Study on the Acupuncture Point Resistance Characteristics(II) (경혈 저항특성에 관한 연구(II))

  • Kim, E.S.;Han, S.C.;Choi, T.J.;Kim, J.K.;Hur, Woong;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.69-72
    • /
    • 2001
  • In this paper, we study about a acupuncture point and a non-acupuncture point resistance characteristics for acupuncture research. For this study, we devised resistance variation measurement system. This system is consist of 4-channel skin resistance measuring parts, filters, 12bit A/D convertor, 8051 micro-controller, and personal computer The developed system insert a low current to skin and obtains voltages from standard resistor that is convected to measurement circuit in series. The obtained voltage is converted to 12bit digital signal. Therefore the converted signal is changed to skin resistance by calculation in the personal computer. As the results of experiment, the resistance of acupuncture point and non-acupuncture point are different from each other. The acupuncture point has very fast current flows than the other non- acupuncture point.

  • PDF

An Empirical Study on the Measurement of Size for Web-Page (웹페이지를 위한 규모측정에 관한 연구)

  • Kim, In-Suk;Lee, Nam-Yong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.52-54
    • /
    • 2003
  • Measurement is used to improve software process and to help calculating software quality. It makes software project to be control and help producing software. Measuring software scale becomes important target in software development. LOC is used to measure the size intentioned aspect and function point is used to measure the function intentioned aspect. This paper discusses measurement method using function point, which fullows proposed rule, and degree of GUI (Graphical User Interface) accesses achieved by applying this measurement to web page. Applying proposed rules to web pages (specially that use much GUI such as shopping mall or auction site), there is advantage that calculate site changes on numerical value by measuring GUI degree when do site administration or update.

  • PDF

A Study on Measurement of SERVQUAL and SERVPERF Measurement - A Sightsee- ing quality of Service to the centers - (SERVQUAL 측정과 SERVPERF 측정 이론 연구 -관광 서비스 품질을 중심으로-)

  • Kim, Chul-Jung
    • The Journal of Information Technology
    • /
    • v.9 no.3
    • /
    • pp.33-47
    • /
    • 2006
  • We will can do quality of measurement of service that thing is quite abstract concept. Generally, we speak Service of quality that property of a product, usability of use, social quality requirement to a quality of service by wide meaning. A purpose of this study was comparison regarding a way to measure of service quality, and in the insufficient section there was anything, and progress of model study of service left no matter how much focus to it. There is comparative study a few progress of literature of a PZB, SERVQUAL, SERVPERF, model. Desarbo, Huff, Rolandelli, & Choi, (1994: 125-131) proposed that to solve the above model contradiction point, and Presentation called a plan based on to Conjoint analysis. There is Critical point to decide on priority order of proposed model of service measurement. This study has a lot of the pieces which are short by absence of empirical study, but will make a supplementation in next term study.

  • PDF

The plastic design of dart location from the viewpoint of visual-spatial division (시각적 공간분할로 본 Dart 위치의 조형적 설계)

  • 정옥임
    • Journal of the Ergonomics Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.33-40
    • /
    • 1987
  • To study the body trunk basic to Clothing construction, and study the peculiarities of visual spatial division, necessary items are measured indirectly from 216 unmarried women from 19 to 24 years old by a photographic net-work method. In so doing, the problem of Fashion Design in establishing the location of Darts for Basic Dress is not considered. The following results are obtained. 1) Indirect measuring method, is obtained approximate to actual size, with an error of .+-. 2.8cm. 2) In the modeling plan of Dart location viewed from the visual-spatial division in Basic Dress, it is concluded that Darts are to be placed at the point of 1/3k+1/5k form the waist. From the aesthetic point of wiew, it is more appealling for darts to be placed at the point of 6cm .+-. 0.6cm right or left of center. 3) From direct measurement dart location can be set based on bust point width, and from indirect measurement, dart location can be set based on waist width.

  • PDF

The estimation of camera's position and orientation using Hough Transform and Vanishing Point in the road Image (도로영상에서 허프변환과 무한원점을 이용한 카메라 위치 및 자세 추정 알고리즘)

  • Chae, Jung-Soo;Choi, Seong-Gu;Rho, Do-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.511-513
    • /
    • 2004
  • Camera Calibration should certain)y be achieved to take an accurate measurement using image system. Calibration is to prove the relation between an measurement object and camera and to estimate twelve internal and external parameters. In this paper, we suggest that an algorithm should estimate the external parameters from the road image and use a vanishing point's character from parallel straight lines in a space. also, we use Hough Transform to estimate an accurate vanishing point. Hough Transform has one of the advantages which is an application for each road environment. we assume a variety of environments to prove the usability of a suggested algorithm and show simulation results with a computer.

  • PDF

The Error Source Analysis of Measuring Data of OMM System (OMM 시스템의 측정오차 원인분석 및 대책)

  • 이상준;김선호;김옥현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.73-77
    • /
    • 1997
  • This paper describes the analysis of measuring error of on the machine measuring(OMM) system which can directly measure the three dimensional machined free surface dimension using scanning probe on milling machine. 21 inch TV shadow mask mould was measured using PTP(point to point)measurement algorithm at pallet clamped and unclamped state on OMM system, and using coordinate measuring machine(CMM) one after another. The OMM system was evaluated probe error, stylus contact error, center shift error, repeatability and so on. Consequencely, the conclusion derived that elastic displacement of pallet had effect on measuring error mainly, and pallet design and setup method would be important.

  • PDF

Development of longitudinal acceleration wave decomposition method with single point measurement (단일 위치에서의 측정을 이용한 가속도 종파 분리 방법의 개발)

  • Jung, B.;Park, Y.;Park, Youn-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.629-633
    • /
    • 2006
  • We investigated a new longitudinal acceleration wave decomposition method in time domain. The proposed method separates up- and down-stream waves with an axial strain and axial acceleration measured at a single point on the transmission path. The advantages such as low computation load and easy implementation would be possible by developing time domain under the following assumptions; low frequency range, uniform cross sectional area and elastic wave propagation. We confirmed the feasibility and performance of the method through experiment using Split Hopkinson Pressure Bar (SHPB). The method can be effective in several applications, including active vibration control with wave view point, where real time wave decomposition is necessary.

  • PDF

Displacement Measurement of Multi-point Using a Pattern Recognition from Video Signal (영상 신호에서 패턴인식을 이용한 다중 포인트 변위측정)

  • Jeon, Hyeong-Seop;Choi, Young-Chul;Park, Jong-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1256-1261
    • /
    • 2008
  • This paper proposes a way to measure the displacement of a multi-point by using a pattern recognition from video signal. Generally in measuring displacement, gab sensor, which is a displacement sensor, is used. However, it is difficult to measure displacement by using a common sensor in places where it is unsuitable to attach a sensor, such as high-temperature areas or radioactive places. In this kind of places, non-contact methods should be used to measure displacement and in this study, images of CCD camera were used. When multi-point is measure by using a pattern recognition, it is possible to measure displacement with a non-contact method. It is simple to install and multi-point displacement measuring device so that it is advantageous to solve problems of spatial constraints.