• Title/Summary/Keyword: measurement of permeability

Search Result 256, Processing Time 0.055 seconds

Permeability Measurement of the Braided Preform in Resin Transfer Molding (고분자 수지 이송 성형에서 브레이드 프리폼의 투과율 계수 측정)

  • Y. K. Cho;Y. S. Song;J. R. Youn
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.65-67
    • /
    • 2002
  • Resin Transfer Molding(RTM) is increasingly used for producing fiber reinforced polymer composites, the resin has to flow a long distance to impregnate the dry fibers. The measure for the resistance of the fiber preform to the resin flow is the permeability of the fiber preform. Permeability is a key issue in the design of molds and processes and in flow modeling. In this study, permeability measurement for braided preform is presented and compared with the permeability calculated numerically. Experimental techniques being used to measure the permeability are also discussed. Measurement is conducted in radial flow test under constant pressure.

  • PDF

Rock Permeability Estimation from Hydraulic Injection Tests in a Sealed Borehole Interval

  • Quach, Nghiep Q.;Jo, Yeonguk;Chang, Chandong
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • We propose a borehole test technique to estimate permeability of rocks in borehole. The borehole tests are hydraulic injection tests such as leak-off test and hydraulic fracturing tests, which are originally conducted for stress or casing integrity assessment and not for permeability measurement. We use one-dimensional radial diffusion equation to interpret fluid injection test results in terms of permeability. We apply this technique to a leak-off test conducted at a depth of 700 m in a wellbore, where rock formation is mudstone. The estimated permeability is at an order of $10^{-16}m^2$, which is somewhat high but within the range reported for mudstones previously. Quantitative rick assessment suggests that an accurate measurement of open hole section length is important to improve reliability of results. More data may be needed to ensure the reliability of this technique. If validated, however, this technique can provide cost-effective estimation of in situ permeability without conducting independent permeability tests in borehole.

Comparison of Gastrointestinal Permeability of Caffeine, Propranolol, Atenolol, Ofloxacin, and Quinidine Measured Using Ussing Chamber System and Caco-2 Cell Monolayer

  • Song, Im-Sook;Choi, Young A;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.34-38
    • /
    • 2017
  • The purpose of this study was to develop a cocktail approach for the measurement of the permeability of marker compounds, caffeine and propranolol (high permeability), ofloxacin (intermediate), atenolol (low), and quinidine (P-glycoprotein substrate), simultaneously. Then we compared the permeability in Caco-2 cells with that in rat intestinal segments. The difference between individual measurement and cocktail approach was less than 20 %, and the permeabilities of these compounds were similar to those previously reported, suggesting that the cocktail transport study and simultaneous drug analysis were successfully developed and validated in this study. Additionally, in the application of this cocktail method, the permeability of five drugs in rat jejunum was similar to that in ileum but different from that in colon, which was measured using the Ussing chamber system. Moreover, permeability in jejunum and ileum was similar to that in Caco-2 cells. In conclusion, the permeability in Caco-2 cells was equivalent to the permeability in rat jejunum and ileum determined with the Ussing system. Therefore, this newly developed cocktail assay and its application to the Ussing system can be a useful tool for robust and rapid screening for site-specific permeability in rat intestine, thus accelerating the prediction of absorption of new chemical entities.

The Study of Improvement of Measurement Precision on Bulk Density, Soil Hardness and Air Permeability in Upland Soils

  • Ok, Jung-hun;Han, Kyung-hwa;Cho, Hee-rae;Zhang, Yong-seon;Seo, Young-ho;Jung, Kang-ho;Lee, Hyub-sung;Kim, Gi-sun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.5
    • /
    • pp.482-488
    • /
    • 2017
  • The measurement based on reliable standard operating procedures (SOPs) is important for consistent information. The objective of this study is to investigate reliable SOPs of soil physical methods, including core method for bulk density, Yamanaka hardness, and air permeameter method for air permeability. The coefficients of variation in bulk density (core method), Yamanaka hardness, and air permeability were ranged of 1~6%, 8~13%, and 10~84%, respectively. The variation in situ measurement such as bulk density, hardness, and air permeability due to spatial variability at measuring site was larger due to the number of replicates, organic matter content, and soil texture. Nevertheless, air permeability had different values as different number of replicates, and thus, it is thought that more replicates can result in higher reliability. It suggested that investigation of soil physical properties for the target sites should required to consider about soil texture, organic matter content, and number of replications before measurement. In conclusion, core sampling for bulk density measurement in upland soil recommended to perform in 3 repetitions with 2 inch core, and 3 inch core sampling for higher organic matter content.

Measurement of Permeability of Food Packaging Polymer Films to Organic Vapors

  • Kim, Jong-Kyoung;Lee, Jun-Ho;Ha, Young-Sun
    • Preventive Nutrition and Food Science
    • /
    • v.6 no.4
    • /
    • pp.247-252
    • /
    • 2001
  • The need to determine the permeability of organic vapors to polymeric films such as aromas, flavors, etc. has significantly increased in the food industry because of preservation and safety issues along with migration problems. However, due to the complex nature of the permeation process, there have been few investigations compared to nonorganic compounds. In this paper, we review the history of permeability studies and typical methods of permeability measurement such as the isostatic method and quasi-isostatic method for organic vapors. New instrumental developments and significant findings are also introduced and discussed.

  • PDF

A study on in-process measurement of hardening depth for LASER surface hardening process control (강재의 레이저 표면경화 공정제어를 위한 경화층깊이의 실시간 측정에 관한 연구)

  • 우현구;박영준;조형석;한유희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.252-257
    • /
    • 1991
  • This paper proposed that the eddy-current measurement method can be used a means of in-process measuring the hardening depth in Laser surface treatment process. Also, this paper deal with the numerical analysis of magnetic flux distribution and experimental result of measurement. In Laser heat treatment process of steels, a thin layer of the substrate is rapidly heated to austenitizing temperature and subsequently cooled at a very fast rate due to the self-quenching by heat conduction into the bulk body, to produce a martensite structure which have low magnetic permeability. The eddy-current measurement method depends on the properties of material to be measured such as electric conductivity, magnetic permeability and geometry. In this paper, the hardening depth was measured by detecting relevant magnetic permeability changes caused by heat treatment of steels.

  • PDF

A Study on the Apparatus for Measuring Oxygen-Permeability of Membranes with a Multi-Electrode Oxygen Sensor (다전극 산소 센서를 이용한 고분자 막의 산소 투과도 측정 장치 연구)

  • Jeong, Il-Son;Jung, Jae-Chil;Kim, Tai-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.229-234
    • /
    • 2012
  • The existing permeability measurements based on pressure differential between the polymer membrane that is permeable to measure the amount of oxygen used, but these methods must be kept in a vacuum, and the measurement of the membrane with low permeability in the membrane is too time consuming. In recent years by using electrochemical method polymer membrane currents caused by the amount of oxygen is a measure of how much is used. In this study, apparatus consisting of one anode and six cathodes for multi-oxygen permeability tester used the same number of membranes produced by electrochemical oxygen permeation characteristics. In this study, one silver/silver chloride anode electrochemical method with a hexagonal sensor to put various kinds of polymer membranes with the six oxygen permeability for simultaneous measurement in real-time systems. Six cathodes (Pt), and one of the coil-shaped anode (Ag/AgCl) to form a hexagonal one of the polarographic oxygen sensor in a single measurement system by six sensors. Each sensor for making hexagonal specificity of the sensor to compensate for the conditions obtained in a pure nitrogen gas and pure oxygen gas conditions. With this study, self-developed hexagonal sensor capable of measuring sensors and oxygen permeability tester, for a multi-six different oxygen permeability characteristics of the membrane measured at the same time.

Measurement of Complex Permittivity and Permeability for Powder-type Materials (분말재료의 복소 유전율 및 투자율 측정)

  • Park, Sang-Bok;Lee, Jang-Soo;Chong, Young-Seek;Cheon, Chang-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2196-2201
    • /
    • 2007
  • Materials used at microwave are usually used as a dielectric with a manufacturing purpose of printed circuit boards, etc. Complex permittivity of them can be measured from attenuation constant or propagation constant of a transmission line using a microstrip line with bulk type. But as the technique recently which can manufacture to have complex permittivity and permeability demanded using nonferrous metals for powder-type grows up, we need sensors and methods which can measure characteristics of powder-type materials. So far measuring methods of permittivity and permeability with waveguide or coaxial cable are used but they have faults which have a complex measurement method and are difficult to simultaneously measure permittivity and permeability. In this paper, a simultaneous measuring method of permittivity and permeability with 2-port coaxial cable and a new proposed calculation. The proposed 2-port coaxial cable is designed to be easy to insert materials and to have a wideband. We measure permittivity and permeability of magnetic powder(Ni-Fe-Mo, Ni-Fe) which reveal its characteristic at $0.3{\sim}1.3GHz$ to identify the proposed sensor.

The Measurement System and Physical Property of Unconsolidated Sample under Trinxial Pressure (삼축압력하에서의 미고결 시료의 물성측정을 위한 측정 장치와 물성 연구)

  • Bae, Wi-Sup;Chung, Tae-Moon;Kwon, Young-Ihn;Kim, Hyun-Tae
    • Journal of the Korean earth science society
    • /
    • v.28 no.7
    • /
    • pp.838-846
    • /
    • 2007
  • A measurement system of tri-axial pressure was designed and constructed to measure permeability and resistivity under changing confining pressure. The system was designed to measure the permeability and resistivity of a core simultaneously, consisting of tri-axial supporting device and sets of dual-flow measurement. In this measurement system the permeability and resistivity of a sample can be directly measured and porosity can be obtained using Archie's laws. As for physical properties, artificial core samples are made from mixtures of standard commercial sand and mud of illite. In-situ sediment cores were sampled at the water-depth of 1,800m in the Ulleung Basin East Sea. In order to investigate the effects of confining pressure changes on physical properties, permeability and resistivity changes were monitored with increasing confining pressure. In this study, it was found that with the increase of confining pressure, permeability and porosity tend to decrease and resistivity tend to increase exponentially.

Out-of-Permeability Measurement of the Braided Preform in Resin Transfer Molding (고분자 수지 이송 성형에서 브레이드 프리폼의 두께방향 투과율 계수 측정)

  • Suk, Chae-Hui;Seok, Song-Yeong;Ryun, Yun-Jae
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.87-90
    • /
    • 2003
  • In Resin transfer molding (RTM), composite parts are produced by impregnation of a dry reinforcement with liquid matrix resin. Permeability is a key issue in this process. For thin parts, the resin flow in the thickness direction can be neglected. Therefore thin parts are considered as two-dimensional composites. However the resin flow through the thickness is important to thicker parts and we have to consider out-of-plane permeability. This work discusses a method to measure out-of-plane permeability. The flow rate and pressure drop across the porous media were measured. Also one dimensional form of Darcy's law is applied to calculate the out-of-plane permeability of various preforms. The flow is injected uniformly into layers of the preform. And a circular fiber mat with 6cm diameter was cut and flattened from cylindrical mandrel.

  • PDF